Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
BOOMERANG PAGING SYSTEM (RCL‐T800) Manual RCL Korea A. EASY INSTALLATION INSTRUCTION StepX Lock the antenna to the right corner of the Boomerang RCL‐T800 Transmitter. (Fit over plug and twist left to lock antenna in place) StepY Plug the Boomerang RCL‐T800 Transmitter A/C adaptor into the Boomerang RCL‐T800 Transmitter and then into a standard outlet. A surge protector is recommended. Step Z RCL‐T800 Transmitter will be fully charged in 4 hours. B. SYSTEM SETTING To enter programming mode, press the “SETUP” button and enter the password “ * * 8 # # ” followed by “ENTER”. If the password is accepted, the display will show “Menu Option F1:Up F2:Down” Use the “F1” or “F2” key to scroll through the several menu options or press “CANCEL” key to exit the system setting menu. 1. Set Time Display With this feature, you can setup current time into the Boomerang transmitter. z At the “Set Time” menu, set the hour using Number key and then press “ENTER” key. z Then enter the minutes and press “ENTER” key. z Press “# 1” key to select “AM”, “# 2” is to select “PM”. After selection of it, then press “ENTER” key z After the correct time is set, press the “ENTER” 2. Set Alerts Type With this feature, you can have the option of changing your pagers alert type. To change the alert type of your pagers, follow the below instructions: z At the “Set Alerts” menu, press the “ENTER” key z If the “Change?” menu appears, press “# 1” key to select “Yes”, “#2”key is to select “NO”, then press “ENTER” key ( press “CANCEL” key, and return to the main menu ) z Select one of 1~7 Alert modes, then press “ENTER” key. 1) Vibration 2) LED 3) Beep 4) Beep/Vib/LED 5) Vibe/LED 6) Beep/Vib 7) Beep/LED ( Use the “F1” key to scroll through these 7 alert modes ) z The pagers will now respond with your new selected alert type. ※ you could change alert type with boomerang transmitter Select your desired alert type from the table below. Type of Alert Transmitter Code Vibrate only #*001 LED lights only #*002 Beep only #*003 Vibrate, LED light, and Beep #*004 Vibrate and LED light #*005 Beep and Vibrate #*006 Beep and LED light #*007 Sleep mode #*016 After all of the charging racks in your system are unplugged, return to the transmitter and follow the following procedure: 1. Select your desired alert type combination from the table above: 2. At the “PAGER # :” prompt, enter the code 7288 on the keypad. 3. Press the blue “SETUP” key above the large red CANCEL key. 4. Your transmitter should then show “MESSAGE : ” 5. Enter the Transmitter Code that corresponds to the alert combination you would like the Customer pager to tone. The * and the # buttons will look like [] on the display. This is normal. 6. Press the large orange “ENTER” button. At this point, all of the pagers in your system should tone with the alert that you selected. To reset the pagers and stop the tones, plug the Charging Racks back into the power. 3. Set Alert Time With this feature, you can set the alert time, how long the pager alerts, when the pager receive the signal from the transmitter. To change the Alert time mode of your pagers, follow these instructions: z At the “Set Alert Time” menu, press “Enter” key. z If the “Change?” menu appears, press “# 1” key to select “Yes” or “# 2” key to select “#”. Then press “ENTER” key. ( Press “CANCEL” key to exit, and return to the main menu ) z Select one of 1∼8 Alert time modes as below, then press “ENTER” key 1) 05 SEC 2) 15 SEC 3) 30 SEC 4) 60 SEC 5) 90 SEC 6) 120 SEC 7) 180 SEC 8) Continuance (Use the “F1” key to scroll through the 8 alert time modes) Also, you could change alert time with boomerang transmitter Select your desired alert time from the table below. Time of Alert Transmitter Code 5 seconds #*010 15 seconds #*012 30 seconds #*013 60 seconds #*014 120 seconds #*015 After all of the charging racks in your system are unplugged, return to the transmitter and follow the following procedure: 1. Select your desired tone length from the table above: 2. At the “PAGER # :” prompt, enter the code 7288 on the keypad. 3. Press the blue “SETUP” key above the large red CANCEL key. 4. Your transmitter should then show “MESSAGE: ” 5. Enter the Transmitter Code that corresponds to the length of time you would like the Customer pager to tone. The * and the # buttons will look like [] on the display. This is normal. 6. Press the large orange “ENTER” button. At this point, all of the pagers in your system should tone for the amount of time that you selected. To reset the pagers and stop the tones, plug the Charging Racks back into the power. 4. Out of Range With this feature, the pagers will play a melody when taken out of range from the transmitter to inform the guest that they are located “Out of Range” and will miss their page. The melody will only stop, when they return back within range. To turn the Out of Range “USE” or “NOT” z At the “Out of Rng” menu, press “Enter” key. z Press “#1” key, then “ENTER” key to turn the Out of Range “USE” (“#2” key is to select “NOT”) z Return all the pagers to the charger base or plug the power supply. The pagers are ready to receive the page with its new message mode. 5. Auto MSG With this feature, you can choose if you will send some designated messages. z At the “Auto MSG” menu, press “ENTER” key z Then press “#1” key, then “ENTER” key to select “USE.” (“#2” key is to select “NOT”) z Return all the pagers to the charger base or plug the power supply. The pagers are ready to receive the page with its new message mode 6. Prog Pager # (ID WRITER PORT) With this feature, you can change a pager number. <Writing Mode> z At “prog pager # ” menu, press the “Enter” Key z If the “Pager # Change?” is displayed, press “#1” key to select “Yes” or “#2” key to select “NOT” Then press “ENTER” key. ( Press “CANCEL” key to exit, and return to the main menu ) z Connect the pin programmer jig to the pager programming holes. z If the LED is blinking, write the digits to program a pager number. z Then press…
Text truncated - open the document above for the full version.
RCL KOREA E-Mail : [email protected] Tel. : 82-32-324-9838 October 07, 2010 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: XTZRCL-T800 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Part List CONF APPENDIX – RCL-T800- Part List.PDF Schematics Diagram(s) CONF APPENDIX - RCL-T800– Schemetics.PDF Block diagram CONF APPENDIX - RCL-T800– Block diagram.PDF The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, RCL KOREA Hyo-Soun, Jeoung / President
www.kes.co.kr EUT External Photographs
Model Name : RCL-T800 Trade Name : Boomerang Transmitter Voltage : DC12V 3.5A + FCC ID : XTZRCL-T800 This device com plies with Part 90 of the FCC Rules MADE IN KOREA FCC Label Position (FCC marking place)
www.kes.co.kr EUT Internal Photographs www.kes.co.kr www.kes.co.kr www.kes.co.kr
Operating Description *Model : RCL-T800 *Product : Boomerang Transmitter 1. SPECIFICATION z Pocsag Code z Frequency Range : 450.0000 ~ 470.00MHz z FM modulation & FSK (frequency shift keying) z Deviation : 4.5 KHz z FM Accuracy : +/-5% 4.275 < 4.5 < 4.725 z Date Rate : 1200BPS, 600Hz +/-5Hz z Output power : 32.5.0dBm z Message : Numeric - Max. 16 digits Alpha – Max. 128 characters z Address Range : 0001 to 1249 z Dimension : W(165) X D(95) X H(35) 2. CIRCUIT DESCRIPTION RCL-T700 uses 12V 2.5A DC Power Supply as its Power supply. If the power is supplied into the DC Jack, it supplies the power to CPU and LCD by U5(7805) which converts the power to +5V, and it also supplies the power to RF(2SK3079) by U14(7810) which converts the power to +10V. Input message by use of Keypad and press ENTER, and then CPU(RD0-RD5 / RE4-RE7) sends the data. With sending a data, it makes the TX On S/W work and supplies the power to RF module. Max. 16 digits numeric numbers are able to be entered and 0000 up to 1249 are available with this system in the address range. If push the Enter button after inputting, CPU(microcontroller) will interface to CC1070 via the 4 wires serial configuration interface(PDI, PDO, PCLK and PSEL). Optionally, the microcontroller can do data encoding and the microcontroller can monitor the LOCK pin for frequency lock status or other status information. This frequency is filtered by way of BPF (L1, L2, L3) and then amplified by Q4, Q5, Q6, Q7, Q8 and then filtered by LPF(L10, L11, L12, L13) and then amplified by FET Q9(2SK3079) and then filtered by LPF(L18, L17, L16) and transmitted to BNC connector. USB port Only use PC program using CP2102(serial to USB chip)
The procedure in this chapter allows the verification of the electrical performance of transmitter. These tests do not require access to the interior of the instrument. Recommended test equipment 1. Frequency Accuracy Frequency : 457.5750MHz Stavility : Same as reference oscillator accuracy. Internal 1ppm 0 to 50degC 1.Test Setup (Connect Boomerang BNC Jack without antenna) 20db att 2. HP-8902A : auto tuning, frequency display 3. Boomerang TRANSMITTER 1) Connect 20dB Attenuators 2) Power On 3) Setup key, enter, password 2386 key enter, Use # key to select " SYNC OFF, RF ON Actual Boomerang TRANSMITTER TUNE UP PROCEDURE DescriptionMinimum specificationModel Power meter Spectrum analyzer Measuring receiver Oscilloscope + / - 0.2dB, - 60 to -20dBm. 100 KHz to 1GHz 100KHz to 12GHz, up to -120 dBm 0.2 to 1300MHz, 0 to -125dBm, Freq Counter DC to 100MHz, 5mV to 1V/div, Rise Time capavility HP-436A/8481D HP-8591E HP-8902A TEK TDS360 HP-53181A Tescom 99910 Frequency Counter Attenuator + / - 0.1ppm, 10Hz ~ 1GHz, 9digit 10W, 20dB Att, DC to 1GHz Upper LimitRemarksTC-1950A FREQ Lower Limit PERFORMANCE TEST HP-8902A Carrier frequency accuracy test 457.5750MHz457.5748457.5752 2. RF Output Level Accuracy RF level : 30dBm Accuracy : +/-1dB 1.Test Setup (Connect Boomerang BNC Jack without antenna) 2.HP-8902A : Auto-tuning, RF Power 3.Boomerang TRANSMITTER 1) Connect 20dB Attenuators 2) Power On 3) Setup key, enter, password 2386 key enter, Use # key to select " SYNC OFF, RF ON 3. Spectral Purity 3.1. Residual FM Noise RMS Noise : <10Hz Typ, 300Hz ~ 3KHz <70Hz Typ, 50Hz ~ 3KHz 1. Test Setup. 20db att (Connect Boomerang BNC Jack without antenna) 2. HP 8902A : FM, RMS, Filter BW 300Hz ~ 3KHz 3. Boomerang TRANSMITTER: 1) Connect 20dB Attenuators 2) Power On 3) Setup key, enter, password 2386 key enter, Use # key to select " SYNC OFF, RF ON HP-8902A HP-8902A TC-1950A Signal Generator Residual FM HPF LPF 300Hz 3KHz10Hz 50Hz 3KHz70Hz 3.2. Harmonic Spurious : Harmonic Level at 2xFOUT : <-60dBc 1. Test Setup. RF OUT input 50 20db att (Connect Boomerang BNC Jack without antenna) 2. HP 8591E : Span = 500KHz, RBW = 10KHz, VBW = 30KHz. 3. Boomerang TRANSMITTER: 1) Connect 20dB Attenuators 2) Power On 3) Setup key, enter, password 2386 key enter, Use # key to select " SYNC OFF, RF ON Level(dBm )Fout-2*Fout Limit 60dbc 4. Modulation 4.1. FM(RECT) (Internal FSK Test Patterns) Deviation Accuracy Deviation : 4.5KHz, Accuracy : +/-5% (4.275 < FM < 4.725)@4.5KHz 1.Test Setup OSCILLOSCOPE Audio input 20db att Boomerang TRANSMITTER Harmonic Spurious Fout(MHz) 457.575 Spurious(MHz) 915.15 Remark 8902 Filter BW ActualLimit (Hz)Remark Harmonice test HP-8591E FSK Deviation and Noise Test (Connect Boomerang BNC Jack without antenna) 2.Equipment HP-8902A : FM, AVG, HPF=OFF, LPF=15KHz TDS360 : 250us/div, 500mV/div Average : 16 3.Boomerang TRANSMITTER: 1) Connect 20dB Attenuators 2) Power On 3) Setup key, enter, password 2386 key enter, Use # key to select " SYNC OFF, RF ON 4. Read FM Deviation in RMS. DEV(Boomerang )Limit 4.5KHz4.5KHz + - 5% Lower Actual Upper 4.2754.725 Table : FSK Deviation Accuracy ItemRemark Deviation (AVG)
RF exposure exhibit FCC RF Exposure Requirements General information : FCCID: XTZRCL-T800 Modulation: Device category: Mobile per Part 2.1091 Environment: General Population/Uncontrolled Exposure Otherwise, compliance with the power density limits of 1.1310 is required. Antenna: The device has a portable antenna to be used for the purpose of reading tags Configuration Antenna p/n Type Max. Gain (dBi) Indoor None Whip 0.33 Operating configuration and exposure conditions: The conducted output power is 1.92W MPE Calculation : The minimum separation distance is calculated as follows: The limit for general population/uncontrolled exposure environment is 0.305 mW/cm2* for a Channel Frequency: 469.965 MHz (A) Antenna Gain (dBi) Separation Distance 0.33 Power Conducted (W) Duty Cycle (%) (in) (cm) 1.92 100 12.84 - - - - Conclusion: The device complies with the MPE requirements by providing a safe separation distance of 20 cm between the antenna, including any radiating structure, and any persons when normally operated . *
www.kes.co.kr Te s t Re p o r t N o. : TK-FR10039 Model No: RCL-T800 Page 1 of 28 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. TEST REPORT For FCC Test Report No. : TK-FR10039 Date of Issue : 10/15/2010 FCC ID : XTZRCL-T800 Description of Product : Boomerang Transmitter Model No. : RCL-T800 Applicant : RCL KOREA 1566 Joong San-dong Ilsang dong-gu, Goyang City Gyeonggi-do Korea Manufacturer : RCL KOREA 1566 Joong San-dong Ilsang dong-gu, Goyang City Gyeonggi-do Korea Standards : FCC Part90 Test Date : 10/07/2010 – 10/15/2010 Test Results : PASS FAIL The test results relate only to the items tested. Tested by: Reviewed by: Kyu-Chul Shin KT Kang Test Engineer Technical Manager Date:10/15/2010 Date: 10/15/2010 THRU-KES CO.,LTD. 477-6, Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do,469-803, Korea Tel: +82-31-425-6200 / Fax: +82-31-424-0450 www.kes.co.kr Te s t Re p o r t N o. : TK-FR10039 Model No: RCL-T800 Page 2 of 28 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. TABLE OF CONTENTS 1.0 General Product Description ...............................................................................3 1.1 Tested Frequency .............................................................................................3 1.2 Power Input into the Final Amplifier.....................................................................3 1.3 Model Differences .............................................................................................4 1.4 Device Modifications .........................................................................................4 1.5 Peripheral Devices ............................................................................................4 1.6 Calibration Details of Equipment Used for Measurement .........................................5 1.7 Test Facility......................................................................................................5 1.8 Laboratory Accreditations and Listings .................................................................5 2.0 Summary of tests .............................................................................................6 2.1 Technical Characteristic Test...............................................................................7 2.1.1 Power Limit................................................................................................7 2.1.2 Type of Emission....................................................................................... 10 2.1.3 Banddwidth Limitation ............................................................................... 11 2.1.4 Emissions Mask ........................................................................................ 13 2.1.5 Transmitter Spurious Conducted Emission .................................................... 16 2.1.6 Frequency Stability ................................................................................... 19 2.1.7 TRANSIENT FREQUENCY BEHAVIOR ............................................................ 21 2.1.8 Field Strength of Surious Radiation.............................................................. 24 APPENDIX A – Test Equipment Used For Tests ................................................................ 26 Test Setup Photo and Configurationb-(Part 90) ............................................................... 27 www.kes.co.kr Te s t Re p o r t N o. : TK-FR10039 Model No: RCL-T800 Page 3 of 28 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. 1.0 General Product Description EUT Type : Boomerang TX FCC Rule Part(s) : §2; §15; §90 Model name : RCL-T800 Serial number : Identical prototype Tx Freq. Range : 450.0250 ~ 469.965 MHz Channel Space Bandwidth 12.5kHz Type of Modulation : 10K2F1D Frequency Tolerance: : ± 0.00025 % (2.5ppm) Maximum Output Power : Conducted: 1.92W Power Source : 12 Vdc Antenna type : Whip antenna Gain: 0.33dBi 1.1 Tested Frequency LOW MID HIGH Frequency (MHz) 450.025 457.575 469.965 1.2 Power Input into the Final Amplifier DC Voltages and currents info the final amplifier : Vce : 12 volts www.kes.co.kr Te s t Re p o r t N o. : TK-FR10039 Model No: RCL-T800 Page 4 of 28 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. 1.3 Model Differences None 1.4 Device Modifications The following modifications were necessary for compliance: Not applicable 1.5 Peripheral Devices Device Manufacturer Model No. Serial No. EUT RCL KOREA RCL-T800 - www.kes.co.kr Te s t Re p o r t N o. : TK-FR10039 Model No: RCL-T800 Page 5 of 28 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. 1.6 Calibration Details of Equipment Used for Measurement Test equipment and test accessories are calibrated on regular basis. The maximum time between calibrations is one year or what is recommended by the manufacturer, whichever is less. All test equipment calibrations are traceable to RRA & HCT, therefore, all test data recorded in this report is traceable to RRA & HCT. 1.7 Test Facility The measurement facility is located at 477-6, Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi- Do,469-803, Korea. Tel: +82-31-883-5092/Fax: +82-31-883-5169. The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR Publication 22. 1.8 Laboratory Accreditations and Listings Country Agency Scope of Accreditation Logo USA FCC 3 & 10 meter Open Area Test Sites and one conducted site to perform FCC Part 15/18 measurements. 343818 KOREA KCC EMI (10 meter Open Area Test Site and two conducted sites) Radio(3 & 10 meter Open Area Test Sites and one conducted site) KR100 Canada IC 3 & 10 meter Open Area Test Sites and one conducted site 4769B-1 www.kes.co.kr Te s t Re p o r t N o. : TK-FR10039 Model No: RCL-T800 Page 6 of 28 This Report shall not be reproduced except in full without the wri…
Text truncated - open the document above for the full version.
www.kes.co.kr Te s t Re p o r t N o. : TK-FR10039 Model No: RCL-T800 Page 27 of 28 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. Test Setup Photo and Configurationb-(Part 90)
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 90 | 450.025 MHz - 469.965 MHz | 1.92 W | 10K2F1D | 2.5000000000 ppm |

BOOMERANG WAITERCALL TX
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter