FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Launch Tech Co., Ltd./
  3. XUJES200

XUJES200New Energy Insulation Tester

Launch Tech Co., Ltd.
New Energy Insulation Tester - FCC ID XUJES200 - Launch Tech Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 11, 2023
Application Purpose
Original Equipment
Date of Application
Apr 11, 2023
Equipment Note
New Energy Insulation Tester
Frequency Range
2402.00000000 - 2480.00000000
Company
Launch Tech Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Version: V1.00.000 Revi sed Time: 12 -06 -2022 LAUNCH ES 200 Insulation Resistance Tester User Manual I Safety Precautions The design, manufacturing and detection of this instrument meet the IEC61010 safety standard (safety requirements for electronic measuring products). This manual includes warnings and safety regulations that must be observed by users to ensure the safe use of the instrument and the safe state of the instrument. Please read the following operating instructions carefully before use. Warning • Please carefully read and understand this instruction before using the instru- ment. • The requirements of this manual must be observed at any time, and the manual shall be kept for reference at any time. • During instrument test, wrong operations will lead to accidents and instrument damage. Conventions The following conventions are used in this manual. Danger In order to avoid serious or fatal damage that may be caused under certain conditions and operations. • Do not measure circuits with AC/DC voltage above 600V. • Do not test in flammable places because sparks may cause explosion. • Do not operate the instrument if the surface of the instrument is wet or the operator’s hand is wet. • Do no t touch the conductive part of the test pen during measurement. • When the test line is short circuited to the instrument, do not press the [TEST] button. • When performing insulation measurement, do not touch the line to be tested. LAUNCH ES 200 Insulation Resistance Tester User Manual II Warning It means avoiding the risk of electric shock. • If the instrument is damaged or exposed, please stop using it. • After the high resistance measurement, the charge storage in the circuit to be tested must be released. • Ensure that all test wires are firmly connected to the test ports of the instrument. • The instrument is a sealed device, and there are no parts that can be repaired by the end user. Do not attempt to disassemble it by yourself. All internal maintenance must be carried out by authorized maintenance organizations or technicians. Attempting to disassemble or modify the device will void the warranty. Precautions Helpful information for avoiding damage to the instrument and for accurate measurement • Before measuring the resistance, the circuit to be tested must be completely discharged and completely isolated from the power supply circuit. • If the test line or power adaptor is damaged and needs to be replaced, the test line or power adaptor of the same model or electrical specification must be replaced. • Do not use the instrument if the battery indicator shows that the battery is exhausted. • Do not store or use this instrument in high temperature, high humidity, flammable, explosive or strong electromagnetic field environment. • Please use a wet cloth or cleaner to clean the instrument housing. Do not use friction or solvent. • When the instrument is wet, please dry it before storing it. LAUNCH ES 200 Insulation Resistance Tester User Manual III FCC Statement Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device (FCC ID: XUJES200) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment .This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. LAUNCH ES 200 Insulation Resistance Tester User Manual IV Table of Contents 1. Product Introduction ....................................................................................... 1 1.1 Brief Introduction .................................................................................. 1 1.2 Ac cessory Included .............................................................................. 1 1.3 Components & Controls ....................................................................... 2 1.4 Technical Specifications........................................................................ 6 2. Operation Instructions .................................................................................... 9 2.1 Charging & Power On/Off ..................................................................... 9 2.2 LCD Display ....................................................................................... 10 2.3 Measurement ......................................................................................11 2.3.1 AC/DC Voltage Measurement ...................................................11 2.3.2 Insulation Resistance (IR) Measurement .................................. 13 2.3.3 On-board Res…

Text truncated - open the document above for the full version.

Attestation Statements

ATTESTATION STATEMENT Applicant: Launch Tech Co., Ltd. Address: Launch Industrial Park, North of Wuhe Rd., Banxuegang, Longgang Shenzhen, China. Tel.: 0755-84528007 E-mail: [email protected] Date: 2023-02-21 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §Part 2.911(d)(5)(i), (ii) Filing FCC ID: XUJES200 Launch Tech Co., Ltd., (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. And Launch Tech Co., Ltd., (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signed by (printed name): Ivy Zhong Title: Manager Signature:

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2023-02-23 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: XUJES200 Launch Tech Co., Ltd. (“the Applicant”) certifies that, as of the date of the filing of the application, Launch Tech (USA) Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. Launch Tech Co., Ltd. (“the Applicant”)accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Launch Tech (USA) Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Launch Tech (USA) Inc. FRN: 0027512607 Address: 1820 S.Milliken Ave, Ontario, CA 91761 Tel.: (1)562-4631 580 Email: [email protected] Signed by (printed name): Eric Wang Signature: Address: Launch Industrial Park, North of Wuhe Rd., Banxuegang, Longgang Shenzhen, China. Tel.: 0755-84528007 E-mail: [email protected] Name: Ivy Zhong Title: Manager Signature:

Cover Letter(s)

Launch Tech Co., Ltd. Address: Launch Industrial Park, North of Wuhe Rd., Banxuegang, Longgang Shenzhen, China. Tel.: 0755-84528007 E-mail: [email protected] QA-FR-170-B FCC Authorization Date: 2023-02-24 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Launch Tech Co., Ltd. hereby authorize Shenzhen Accurate Technology Co., Ltd. to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Shenzhen Accurate Technology Co., Ltd. on our behalf shall have the same effect as our own action. We, Launch Tech Co., Ltd. the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature Name: Ivy Zhong Title: Manager

Cover Letter(s)

Launch Tech Co., Ltd. Address: Launch Industrial Park, North of Wuhe Rd., Banxuegang, Longgang Shenzhen, China. Tel.: 0755-84528007 E-mail: [email protected] FCC Confidential Authorization Date: 2023-02-24 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: XUJES200 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Launch Tech Co., Ltd. hereby requests long-term confidential treatment of information accompanying this application as outlined below: Block Diagram Schematics Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature Name: Ivy Zhong Title: Manager

External Photos

Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02718E-RF External Photos Page 1 of 5 External Photos Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02718E-RF External Photos Page 2 of 5 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02718E-RF External Photos Page 3 of 5 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02718E-RF External Photos Page 4 of 5 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02718E-RF External Photos Page 5 of 5

ID Label/Location Info

Shenzhen Accurate Technology Co., Ltd. Report No.: RA230117-02718E-RF EXHIBITA-FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the time purchase (Labeling requirements per 2.295)

Internal Photos

Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02718E-RF Internal Photos Page 1 of 4 Internal Photos Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02718E-RF Internal Photos Page 2 of 4 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02718E-RF Internal Photos Page 3 of 4 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02718E-RF Internal Photos Page 4 of 4 ANT

RF Exposure Info

Shenzhen Accurate Technology Co., Ltd. Report No.: RA230117-02718E-RF Version 11: 2021-11-09 Page 13 of 41 FCC-BLE FCC §1.1307 (b) & §2.1093 – RF EXPOSURE Applicable Standard According to FCC §2.1093 and §1.1307(b), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D04 Interim General RF Exposure Guidance v01, clause 2.1.2 – 1- mW test Exemption: Per § 1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption. Test Result For worst case: Mode Frequency Maximum Tune-up Conducted Power 1-mW test Exemption (MHz) (dBm) (mW) BLE 2402-2480 -3.5 0.45 Yes Result: Compliant.

Test Report

ShenzhenAi-ThinkerTechnology Co.,Ltd -1- SPECIFIC ATIONFORAPPROVAL CUSTOMER:Shenzhen Ai-Thinker Technology Co., Ltd CUS PART NO:PB-02 PART NAME:BT Antenna Edition:1.0 410,BlockC,HuafengSmartInnovationPort.Gushu2nd Road,GushuCommunity,XixiangStreet,Baoan District,Shenzhen,China ShenzhenAi-ThinkerTechnology Co.,Ltd -2- Directory 1 、 Product picture ..............................................................3 2、 Performance parameter ......................................................3 3 、 VSWR ..........................................................................4 4、 Passive test data ...........................................................5 5、 Radiation pattern ............................................................5 ShenzhenAi-ThinkerTechnology Co.,Ltd -3- Productspecification 1、 Product picture 2、Performance parameter NameBT Antenna Model TypePCB Print Antenna ELECTRICAL SPECTFICATIONS Frenquency Range2400-2500MHz Band Width100MHz Impedance50Ω ShenzhenAi-ThinkerTechnology Co.,Ltd -4- VSWR< 2.0 Max Gain1.71dBi PolarizationVertical/Horizontal RadiationOmnidirectional Power50 W MECHANICAL SPECTFICATIONS ConnectorWelding type Working Temperature-40°C - + 85°C Limit Temperature-40°C - + 125°C 3、VSWR ShenzhenAi-ThinkerTechnology Co.,Ltd -5- 4、Passive test data: Frequency (MHz)24002410242024302440245024602470248024902500 Gain (dBi)1.241.341.531.481.601.711.541.441.421.111.06 Efficiency (%)39.9741.1543.0942.5343.5244.8643.8444.0544.8642.3142.69 5、Ra diation pattern

Test Report

Note: This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. Shenzhen Accurate Technology Co., Ltd. is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. Shenzhen Accurate Technology Co., Ltd. 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China Tel: +86 755-26503290 Fax: +86 755-26503396 Web: www.atc-lab.com Version 11: 2021-11-09 Page 1 of 41 FCC-BLE TEST REPORT Applicant Name : Launch Tech Co., Ltd. Address : Launch Industrial Park, North of Wuhe Rd., Banxuegang, Longgang, Shenzhen, China. Report Number : RA230117-02718E-RF FCC ID: XUJES200 Test Standard (s) FCC PART 15.247 Sample Description Product Type: New Energy Insulation Tester Model No.: ES 200 Trade Name: LAUNCH Date Received: 2023-01-17 Date of Test: 2023-02-06 to 2023-02-07 Report Date: 2023-02-09 Test Result: Pass* * In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Roger.Ling Candy Li EMC Engineer EMC Engineer Shenzhen Accurate Technology Co., Ltd. Report No.: RA230117-02718E-RF Version 11: 2021-11-09 Page 2 of 41 FCC-BLE TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 3 GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 TEST METHODOLOGY .................................................................................................................................................. 4 MEASUREMENT UNCERTAINTY .................................................................................................................................... 5 TEST FACILITY ............................................................................................................................................................. 5 SYSTEM TEST CONFIGURATION .......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 6 EUT EXERCISE SOFTWARE .......................................................................................................................................... 6 SPECIAL ACCESSORIES ................................................................................................................................................. 6 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 6 DUTY CYCLE ............................................................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................. 10 BLOCK DIAGRAM OF TEST SETUP .............................................................................................................................. 10 SUMMARY OF TEST RESULTS ............................................................................................................................. 11 TEST EQUIPMENT LIST ......................................................................................................................................... 12 FCC §1.1307 (b) & §2.1093 – RF EXPOSURE ......................................................................................................... 13 TEST RESULT ............................................................................................................................................................. 13 FCC §15.203 – ANTENNA REQUIREMENT .......................................................................................................... 14 APPLICABLE STANDARD ............................................................................................................................................ 14 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 14 FCC §15.205, §15.209 & §15.247(d) – RADIATED EMISSIONS ........................................................................... 15 APPLICABLE STANDARD ............................................................................................................................................ 15 EUT SETUP ................................................................................................................................................................ 15 EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP .............................................................................................. 16 TEST PROCEDURE ......................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02718E-RF Page 1 of 2 Photo of Radiated Emission Measurement Below 1GHz Photo of Radiated Emission Measurement Above 1GHz Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02718E-RF Page 2 of 2

Contact Information

Applicant

Ivy Zhong(Manager)
[email protected](86)755-84528007Fax: (86) 755-84528889

Test Firm

Shenzhen Accurate Technology Co., Ltd.Lisa Zhang
[email protected]+86-755-26503290

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz400.00 µW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted.

Other Applications from Launch Tech Co., Ltd.

Automotive Diagnostic Tool - FCC ID XUJOADDPD1303A - Launch Tech Co., Ltd.
XUJOADDPD1303A

Automotive Diagnostic Tool

Sep 17, 2026

Equipment Class

DTS - Digital Transmission System
Remote Diagnosis Interface - FCC ID XUJS4006 - Launch Tech Co., Ltd.
XUJS4006

Remote Diagnosis Interface

Sep 04, 2026

Equipment Class

DTS - Digital Transmission System
XUJEVT511S

Battery Pack Airtightness Tester (High Voltage)

Jul 09, 2026

Equipment Class

DTS - Digital Transmission System
Car Sense Vision - FCC ID XUJG5201 - Launch Tech Co., Ltd.
XUJG5201

Car Sense Vision

Jun 26, 2026

Equipment Class

PCB - PCS Licensed Transmitter
Automotive Diagnostic Tool - FCC ID XUJOADDPD1005A - Launch Tech Co., Ltd.
XUJOADDPD1005A

Automotive Diagnostic Tool

Jun 05, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX