FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Grand Dragon International Enterprise Limited/
  3. XWE-CS9133

XWE-CS9133QUAD BAND GSM MOBILE PHONE WITH BLUETOOTH

Grand Dragon International Enterprise Limited
QUAD BAND GSM MOBILE PHONE WITH BLUETOOTH - FCC ID XWE-CS9133 - Grand Dragon International Enterprise Limited
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Jan 17, 2010
Application Purpose
Original Equipment
Date of Application
Jan 14, 2010
Equipment Note
QUAD BAND GSM MOBILE PHONE WITH BLUETOOTH
Frequency Range
1850.20000000 - 1909.80000000
Company
Grand Dragon International Enterprise Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Table of Contents 1. Important Safety Guideline ........................................................................................2 2. Phone Overview ........................................................................................................3 3. Starting Up.................................................................................................................5 3.1 Installing SIM card .......................................................................................5 3.2 Installing battery ...............................................................................................5 3.3 Charging battery ...............................................................................................6 3.4 Switching on/off phone...............................................................................6 3.5 LCD display symbols........................................................................................6 4. Making Phone Call......................................................................................................8 4.1 Answering a call................................................................................................8 4.2 Making a call....................................................................................................8 4.3 Making a call with Speed Dial button...............................................................8 4.4 Redialing........................................................................................................... 9 4.5 Making emergency call......................................................................................9 4.6 Adjusting volume...........................................................................................10 4.7 Adjusting tone level response...................................................................... ..10 5. Menu Tree.............................................................................................................. ..10 6. Setting Phonebook....................................................................................................12 7. Message.....................................................................................................................13 8. Call Log.....................................................................................................................14 9. Care...........................................................................................................................14 9.1 Speed Dial ...............................................................................................14 9.2 Emergency Call .......................................................................................15 9.3 Fall Detection-SOS service.....................................................................16 9.3.1 Enabling Fall Detection-SOS Service...............................................16 9.3.2 Disabling Fall Detection SOS service...............................................17 9.4 Medical Alert..............................................................................................17 9.4.1 Doctor Appointment..........................................................................17 9.4.2 Medicine Refill..................................................................................18 9.4.3 Taking Medicine................................................................................19 10. Organizer.................................................................................................................20 11. FM Radio.................................................................................................................21 12. Settings....................................................................................................................21 12.1 User profile.......................................................................................................21 12.2 Bluetooth...........................................................................................................21 12.3 Phone setup................................................................................................... ...23 12.4 Network setup..................................................................................................23 12.5 Security setup...................................................................................................23 12.6 Restore factory settings....................................................................................25 12.7 Call setting........................................................................................................25 13. Content Table................................................................................27 1 1. Important Safety Guideline Important: please read this user manual carefully before you begin using the phone and keep this user manual for future use. If you pass the device to a third party, be sure to pass this manual too. Non-observance of this manual can result in serious injury or damage to the device. Warning: These warning notices must be observed in order to prevent any injury to the user or to third parties. -Different countries may apply different regulations to the use of mobile phones(eg when driving, hospitals, at petrol stations, in aircraft).Please check the laws on the use of a mobile phone in your country and switch off the phone when usage is not permitted, or when dangerous situations or interference could occur. - Only use the phone in accordance with its purpose and at locations where telephoning poses no dangers. - Only use the manufacturer's charger and battery. Inserting an unsuitable battery or inserting the battery incorrectly can result in danger of explosion.The battery must not be opened or exposed to a flame. - The operation of medical devices might be affected. The manufacturers of pacemakers recommend a minimum distance of 20cm between the dev…

Text truncated - open the document above for the full version.

External Photos

External Photos 1. Front View of EUT 2. Back View of EUT 3. Side View of EUT

ID Label/Location Info

Model: CS9133 FCC ID: XWE-CS9133 Made in China IMEI: 359140030000000 MFG Date: 12 / 2009 S/N: 09129000005 0700 CS9133 Handset Label 2 8 m m 32.4mm CS9133 Handset Label Position Scale:1:1 Model: CS9133 FCC ID: XWE-CS9133 Made in China IMEI: 359140030000000 MFG Date: 12 / 2009 S/N: 09129000005 0700 ConnectEasy ConnectEasy

ID Label/Location Info

Grand Dragon International Enterprise Limited 08 Dec, 2010 Equipment Authorization Division Office of Engineering and Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Ref: FCC ID: XWE-CS9133 Dear Sirs: Grand Dragon International Enterprise Limited requests acceptance of the labeling proposal described below for cell phone bearing FCC identifier XWE-CS9133. The subject cell phone are compact handheld models as shown in figure 1, authorized under 47CFR Part 22&24 for GSM mobile services. Figure 1. Because the majority of the cell phone housing is composed of display, speaker, operating controls and a removable battery pack, there is extremely limited space available to attach the required label carrying the FCC identifier. Attaching the label to the battery pack is not acceptable because the battery pack is a removable item. For this reason, Grand Dragon International Enterprise Limited proposes placing the label carrying the FCC identifier inside the battery compartment as shown in figure 2. Grand Dragon International Enterprise Limited Figure 2. The consumer packaging for these models includes the battery pack as a separate item, NOT installed on the radio. As such, the FCC identifier will be readily visible to the user before the battery pack is installed and whenever the battery pack is removed or replaced. In this location, the label will also be protected from physical abuse and remain readable for the anticipated life of the device. The consumer packaging for these models is a "gift box" which does not allow the transceiver to be seen at time of purchase. In order to meet the requirements of 47CFR Part 2.925 (d), Grand Dragon International Enterprise Limited will add the FCC identifier " XWE-CS9133" to the outside of the consumer "gift box" packaging. Thank you for your attention to this matter. Yours Sincerely,

Internal Photos

Internal Photos

RF Exposure Info

Ref: CR-280-18-08-SATB-A COMOHAC E-Field probe Calibration Report Page: 1/7 Issue: A Date: 2009/10/05 1 COMOHAC E-FIELD PROBE CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: HAC TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-18-08-SATB-A COMOHAC E-Field probe Calibration Report Page: 2/7 Issue: A Date: 2009/10/05 2 COMOHAC E-FIELD PROBE CALIBRATION REPORT DATE: 14/11/2009 REFERENCE: SN 41/08 EPH17 OBJECT: COMOHAC E-FIELD PROBE MANUFACTURER: SATIMO SERIAL NUMBER: SN 41/08 EPH17 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 24/09/200 9 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-18-08-SATB-A COMOHAC E-Field probe Calibration Report Page: 3/7 Issue: A Date: 2009/10/05 3 PRODUCT DESCRIPTION Frequency Range 100 MHz - 3 GHz Probe length 330 mm Length of one dipole 3.3 mm Maximum external diameter 8 mm Probe extremity diameter 6 mm Distance between dipoles/probe extremity 3 mm Resistance of the three dipole (at the connector) Dipole 1: R1=2.1807 MΩ Dipole 2: R2=2.0612 MΩ Dipole 3: R3=2.1892 MΩ Connector (HIROSE series SR30) 6 wire male (Hirose SR30series) The probe could be checked by measuring the resistance of the three dipoles. CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION Calibration bench SATIMO AIR CALIBRATION SOFTWARE Multimeter Keithley 2000 Ref: CR-280-18-08-SATB-A COMOHAC E-Field probe Calibration Report Page: 4/7 Issue: A Date: 2009/10/05 4 MEASUREMENT PROCEDURE Probe calibration is realized by using the waveguide method. The probe was inserted in a waveguide loading by a 50 load. By controlling the input power in the waveguide, we are able to create a know E- Field value in the waveguide. , Keithley configuration: Rate = Medium; Filter =ON; RDGS=10; FILTER TYPE =MOVING AVERAGE; RANGE AUTO PROBE UNCERTAINTIES Ref: CR-280-18-08-SATB-A COMOHAC E-Field probe Calibration Report Page: 5/7 Issue: A Date: 2009/10/05 5 A. Calibration parameters 800-2450 MHz. Temperature 21°C Cable loss 0.00 dB Coupler loss 20.30 dB Low limit detection 1.91 V/m Calibration curves ei=f(V) (i=1,2,3) allow to obtain E-field value using the formula: E=(e1*e1+e2*e2+e3*e3)pow(1/2) Calibration curves 0 100 200 300 400 500 600 700 -0,5-0,4-0,3-0,2-0,10 Voltage (V) E-Field (V/m) Dipole 1 Dipole 2 Dipole 3 The following tables represent the calibration curves linearization by curve segment in CW signal. Ref: CR-280-18-08-SATB-A COMOHAC E-Field probe Calibration Report Page: 6/7 Issue: A Date: 2009/10/05 6 Calibration coefficients for the three dipoles in CW: v1 e1 v2 e2 v3 e3 -0,391059 583,917909 -0,354339 583,917909 -0,306717 583,917909 -0,378181 571,371919 -0,346227 571,371919 -0,300527 571,371919 -0,357013 551,074564 -0,330481 551,074564 -0,289309 551,074564 -0,331842 526,648093 -0,310342 526,648093 -0,275382 526,648093 -0,30612 498,442358 -0,288505 498,442358 -0,259231 498,442358 -0,279772 465,543452 -0,263918 465,543452 -0,239942 465,543452 -0,253089 428,936208 -0,237544 428,936208 -0,218233 428,936208 -0,226841 392,389511 -0,213691 392,389511 -0,196671 392,389511 -0,200327 353,811786 -0,188228 353,811786 -0,173755 353,811786 -0,175179 316,614131 -0,163997 316,614131 -0,151754 316,614131 -0,152236 282,250491 -0,141951 282,250491 -0,131536 282,250491 -0,131655 251,273729 -0,122246 251,273729 -0,113368 251,273729 -0,114288 225,321775 -0,106239 225,321775 -0,098262 225,321775 -0,098166 200,556749 -0,09081 200,556749 -0,084047 200,556749 -0,083761 178,106966 -0,076961 178,106966 -0,071298 178,106966 -0,071086 158,100238 -0,064944 158,100238 -0,060184 158,100238 -0,059706 139,817731 -0,054276 139,817731 -0,050265 139,817731 -0,050587 125,051541 -0,045935 125,051541 -0,042367 125,051541 -0,042039 110,684861 -0,037963 110,684861 -0,035009 110,684861 -0,034878 98,193414 -0,031308 98,193414 -0,028847 98,193414 -0,028753 86,981497 -0,025682 86,981497 -0,023631 86,981497 -0,023561 77,117391 -0,020891 77,117391 -0,019237 77,117391 -0,019292 68,625926 -0,01709 68,625926 -0,015679 68,625926 -0,01569 60,891251 -0,013801 60,891251 -0,012687 60,891251 -0,012702 54,088086 -0,011137 54,088086 -0,01022 54,088086 -0,010229 47,945649 -0,008932 47,945649 -0,008192 47,945649 -0,008235 42,632657 -0,007168 42,632657 -0,006573 42,632657 -0,00665 38,021403 -0,005791 38,021403 -0,005295 38,021403 -0,005333 33,81729 -0,004629 33,81729 -0,004243 33,81729 -0,004257 30,037008 -0,003689 30,037008 -0,003378 30,037008 -0,003404 26,719225 -0,00295 26,719225 -0,002696 26,719225 -0,002717 23,778972 -0,002353 23,778972 -0,002165 23,778972 -0,002177 21,206988 -0,001894 21,206988 -0,001727 21,206988 -0,001752 18,888081 -0,001512 18,888081 -0,001387 18,888081 -0,001393 16,823167 -0,001207 16,823167 -0,001108 16,823167 -0,001118 14,986399 -0,000967 14,986399 -0,000886 14,986399 -0,00089 13,328016 -0,000771 13,328016 -0,000717 13,328016 -0,000718 11,923626 -0,000629 11,923626 -0,000574 11,923626 -0,00059 10,624355 -0,0005 10,624355 -0,000465 10,624355 -0,000466 9,444142 -0,000408 9,444142 -0,000374 9,444142 -0,000…

Text truncated - open the document above for the full version.

RF Exposure Info

Ref: CR-280-19-08-SATB-A COMOHAC H-Field probe Calibration Report Page: 1/10 Issue: A Date: 2009/10/05 1 COMOHAC H-FIELD PROBE CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: HAC TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-19-08-SATB-A COMOHAC H-Field probe Calibration Report Page: 2/10 Issue: A Date: 2009/10/05 2 COMOHAC H-FIELD PROBE CALIBRATION REPORT DATE: 14/11/2009 REFERENCE: SN 41/08 HPH18 OBJECT: COMOHAC H-FIELD PROBE MANUFACTURER: SATIMO SERIAL NUMBER: SN 41/08 HPH18 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 24/09/200 9 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-19-08-SATB-A COMOHAC H-Field probe Calibration Report Page: 3/10 Issue: A Date: 2009/10/05 3 PRODUCT DESCRIPTION Frequency Range 100 MHz - 30 GHz Probe length 330 mm Dimension of one loop 3.3 mm Maximum external diameter 8 mm Probe extremity diameter 6 mm Distance between dipoles/probe extremity 3 mm Resistance of the three dipole (at the connector) Dipole 1: R1=2.1650 MΩ Dipole 2: R2=2.2176 MΩ Dipole 3: R3=2.4084 MΩ Connector (HIROSE series SR30) 6 wire male (Hirose SR30series) The probe could be checked by measuring the resistance of the three ways. CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION Calibration bench SATIMO AIR CALIBRATION SOFTWARE Multimeter Keithley 2000 MEASUREMENT PROCEDURE Probe calibration is realized by using the waveguide method. The probe was inserted in a waveguide loading by a 50 load. By controlling the input power in the waveguide, we are able to create a know H- Field value in the waveguide. Keithley configuration: Rate = Medium; Filter =ON; RDGS=10; FILTER TYPE =MOVING AVERAGE; RANGE AUTO Ref: CR-280-19-08-SATB-A COMOHAC H-Field probe Calibration Report Page: 4/10 Issue: A Date: 2009/10/05 4 PROBE UNCERTAINTIES Ref: CR-280-19-08-SATB-A COMOHAC H-Field probe Calibration Report Page: 5/10 Issue: A Date: 2009/10/05 5 A. Calibration parameters 800-1000 MHz. Temperature 21°C Cable loss 0.00 dB Coupler loss 20.30 dB Low limit detection 0.009 A/m Calibration curves hi=f(V) (i=1,2,3) allow to obtain H-field value using the formula: H=(h1*h1+h2*h2+h3*h3)pow(1/2) Calibration curves 0 0,5 1 1,5 2 2,5 3 3,5 -1,5-1-0,50 Voltage (V) E-Field (V/m) Dipole 1 Dipole 2 Dipole 3 The following tables represent the calibration curves linearization by curve segment in CW signal. Ref: CR-280-19-08-SATB-A COMOHAC H-Field probe Calibration Report Page: 6/10 Issue: A Date: 2009/10/05 6 Calibration coefficients for the three loops in CW: v1 h1 v2 h2 v3 h3 -0,386758 3,3612 -1,228248 3,3868 -0,613324 3,4576 -0,346668 2,9412 -1,106784 2,9704 -0,547987 3,0332 -0,307706 2,6008 -0,989555 2,6228 -0,485971 2,6816 -0,271061 2,308 -0,879874 2,32 -0,428227 2,3712 -0,238197 2,0344 -0,779503 2,0608 -0,37642 2,1012 -0,210244 1,8296 -0,694408 1,8528 -0,332852 1,888 -0,183745 1,6224 -0,612353 1,6424 -0,291397 1,6792 -0,160391 1,4424 -0,539657 1,462 -0,254668 1,4936 -0,139165 1,28 -0,4729 1,2952 -0,221251 1,3212 -0,120617 1,1308 -0,414229 1,1484 -0,191893 1,1696 -0,105005 1,0092 -0,364351 1,0264 -0,16732 1,0456 -0,090243 0,8988 -0,317641 0,9156 -0,144273 0,9288 -0,077376 0,7988 -0,276292 0,808 -0,123869 0,8256 -0,065792 0,7084 -0,238578 0,7168 -0,105684 0,7328 -0,05574 0,6296 -0,206008 0,6372 -0,09006 0,652 -0,047389 0,5628 -0,178282 0,5688 -0,076968 0,582 -0,039605 0,5 -0,152755 0,5048 -0,06484 0,5168 -0,032977 0,4436 -0,130295 0,4492 -0,054283 0,4588 -0,02731 0,394 -0,111077 0,3996 -0,04533 0,4064 -0,022509 0,3488 -0,093768 0,3528 -0,03763 0,3608 -0,018582 0,3124 -0,079883 0,3164 -0,031347 0,3224 -0,015099 0,2768 -0,067357 0,28 -0,025836 0,2864 -0,012254 0,246 -0,056258 0,2484 -0,021186 0,254 -0,009897 0,2188 -0,047082 0,2208 -0,017231 0,2252 -0,008 0,194 -0,039175 0,1964 -0,01409 0,2008 -0,006488 0,1736 -0,032658 0,1756 -0,011516 0,1796 -0,005242 0,154 -0,026875 0,156 -0,009289 0,1588 -0,004171 0,1372 -0,022034 0,1392 -0,007485 0,1416 -0,003341 0,122 -0,018019 0,1236 -0,006002 0,126 -0,00266 0,1088 -0,014574 0,1104 -0,004807 0,112 -0,002155 0,0972 -0,011952 0,0988 -0,003875 0,1004 -0,001711 0,0868 -0,009672 0,0884 -0,003113 0,0896 -0,001367 0,0772 -0,007728 0,0784 -0,002485 0,08 -0,00109 0,0688 -0,006228 0,0696 -0,001996 0,0712 -0,000872 0,0612 -0,004988 0,0624 -0,001589 0,0636 -0,000711 0,0552 -0,004076 0,0564 -0,001288 0,0572 -0,000565 0,0492 -0,003269 0,0504 -0,001035 0,0508 -0,000456 0,044 -0,002632 0,0448 -0,000829 0,0456 -0,000368 0,0396 -0,00209 0,04 -0,000664 0,0408 -0,000304 0,0352 -0,00168 0,0356 -0,000531 0,0364 -0,000249 0,032 -0,001365 0,0324 -0,000436 0,0328 -0,000206 0,0288 -0,001097 0,0292 -0,000355 0,0296 -0,000164 0,0256 -0,00088 0,0264 -0,000292 0,0264 Ref: CR-280-19-08-SATB-A COMOHAC H-Field probe Calibration Report Page: 7/10 Issue: A Date: 2009/10/05 7 -0,000137 0,0232 -0,000704 0,0236 -0,000238 0,024 -0,000113 0,0208 -0,00057 0,0212 -0,000195 0,0216 -0,0001 0,0192 -0,000462 0,0192 -0,000167 0,0196 -8,10E-05 0,0172 -0,000369 0,0176 -0,00013 0,018 -7,30E-05 0,0…

Text truncated - open the document above for the full version.

RF Exposure Info

Ref: CR-280-21-08-SATB-A COMOHAC Broadband 800- 950 MHz dipole Calibration Report Page: 1/4 Issue: A Date: 2009/10/05 1 COMOHAC BROADBAND 800-950 MHZ DIPOLE CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: HAC TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-21-08-SATB-A COMOHAC Broadband 800- 950 MHz dipole Calibration Report Page: 2/4 Issue: A Date: 2009/10/05 2 COMOHAC BROADBAND DIPOLE 800-950 MHz CALIBRATION REPORT DATE: 14/11/2009 REFERENCE: SN 36/08 DHA16 OBJECT: BROADBAND DIPOLE 800-950 Mhz MANUFACTURER: SATIMO SERIAL NUMBER: SN 36/08 DHA16 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 24/09/200 9 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-21-08-SATB-A COMOHAC Broadband 800- 950 MHz dipole Calibration Report Page: 3/4 Issue: A Date: 2009/10/05 3 PRODUCT DESCRIPTION CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION Vector Network Analyzer HP8753D MEASUREMENT PROCEDURE Measurement of the return loss of the dipole in air -40 -35 -30 -25 -20 -15 -10 -5 0 800820840860880900920940 Fre que ncy, M Hz S11, dB VSWR between 800 and 950 MHz < -10 dB. Ref: CR-280-21-08-SATB-A COMOHAC Broadband 800- 950 MHz dipole Calibration Report Page: 4/4 Issue: A Date: 2009/10/05 4 MEASUREMENT RESULT Input power of the dipole: 20 dBm Distance between the dipole and the probe: 10 mm Scan resolution: 5 mm Frequency E-Field H-Field 900 MHz 205 V/m 0.448 A/m

RF Exposure Info

Report No.: SZ09100093S02 Page 2 of 138 Contents 1.1. Notes.........................................................................................................................................3 1.2. Organization item....................................................................................................................3 1.3. Conclusion................................................................................................................................3 2. TESTING LABORATORY.......................................................................................................4 2.1. Identification of the Responsible Testing Laboratory..........................................................4 2.2. Identification of the Responsible Testing Location..............................................................4 2.3. Accreditation Certificate........................................................................................................4 2.4. List of Test Equipments..........................................................................................................4 3. TECHNICAL INFORMATION ...............................................................................................5 3.1. Identification of Applicant......................................................................................................5 3.2. Identification of Manufacturer..............................................................................................5 3.3. Equipment Under Test (EUT)................................................................................................5 3.3.1. Photographs of the EUT..................................................................................................6 3.3.2. Identification of all used EUTs........................................................................................6 4. TEST RESULTS 6 4.1. Applied Reference Documents...............................................................................................6 4.2. Test Environment/Conditions................................................................................................7 4.3. Operational Conditions During Test.....................................................................................8 4.3.1. Informations On The Testing..........................................................................................8 4.3.2. The Measurement System.............................................................................................10 4.3.3. Uncertainty Assessment.................................................................................................12 4.3.4. Equipments and results of validation testing...............................................................13 4.3.5. Dielectric Performance..................................................................................................14 4.3.6. Simulant liquids..............................................................................................................15 4.4. Items used in the Test Results List.......................................................................................15 4.5. Test Results List.....................................................................................................................16 ANNEX A ACCREDITATION CERTIFICATE..........................................................................18 ANNEX B PHOTOGRAPHS OF THE EUT ................................................................................19 ANNEX C GRAPH TEST RESULTS ...........................................................................................23 Report No.: SZ09100093S02 Page 4 of 138 2. Testing Laboratory 2.1. Identification of the Responsible Testing Laboratory Company Name: Shenzhen Electronic Product Quality Testing Center Department: Morlab Laboratory Address: 3/F, Electronic Testing Building, Shahe Road, Nanshan District, Shenzhen, 518055 P. R. China Responsible Test Lab Manager: Mr. Shu Luan Telephone: +86 755 86130268 Facsimile: +86 755 86130218 2.2. Identification of the Responsible Testing Location Name: Shenzhen Electronic Product Quality Testing Center Morlab Laboratory Address: 3/F, Electronic Testing Building, Shahe Road, Nanshan District, Shenzhen, 518055 P. R. China 2.3. Accreditation Certificate Accredited Testing Laboratory: No. CNAS L1659 (see Annex A) 2.4. List of Test Equipments No. Instrument Type 1 PC Dell (Pentium IV 2.4GHz, SN:X10-23533) 2 Network Emulator Rohde&Schwarz (CMU200, SN:105894) 3 Voltmeter Keithley (2000, SN:1000572) 4 Synthetizer Rohde&Schwarz (SML_03, SN:101868) 5 Amplifier Nucl udes (ALB216, SN:10800) 6 Power Meter Rohde&Schwarz (NRVD, SN:101066) 7 Probe Antennessa (SN:SN_3708_EP80) 8 Phantom Antennessa (SN:SN_36_08_SAM62) 9 Liquid Antennessa (Last Calibration:21 08 04) Report No.: SZ09100093S02 Page 5 of 138 3. Technical Information Note: the following data is based on the information by the applicant. 3.1. Identification of Applicant Company Name: GRAND DRAGON INTERNATIONAL ENTERPRISE LIMITED Address: Room 1307-8, Dominion Centre, 43-59 Queen's Road East, Wanchai, Hong Kong 3.2. Identification of Manufacturer Company Name: In-Tech Electronics Ltd Address: Unit A , 13/F,Wing Tai Centre,12 Hing Yip Street, Kwun Tong , Kowloon, Hong Kong. 3.3. Equipment Under Test (EUT) Brand Name: ABE CS9133 Type Name: ABE CS9133 Marking Name: CS9133 / BP01 Hardware Version: 0.1 Software Version: 0.1 Frequency Bands: GSM 850MHz (channel 128:824.20MHz,channel 190:836.59MHz, channel 251:848.29MHz) PCS 1900MHz (channel 512:1850.19MHz,channel 661:1880.00MHz, channel 810:1909.80MHz) Modulation Mode: GMSK Antenna type: Build inside Accessories: Charger; Battery Battery Model: 9133-5C Battery specification: 900mAh 3.7V Development Stage Identical prototype Report No.: SZ09100093S02 Page 6 of 138 3.3.1. Photographs of the EUT Please see for photographs of the EUT. 3.3.2. Identification of all used EUTs The EUT …

Text truncated - open the document above for the full version.

Test Report

Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 1/26 Issue: A Date: 2009/10/05 1 COMOSAR E-FIELD PROBE CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 2/26 Issue: A Date: 2009/10/05 2 COMOSAR SEPT ISOTROPIC E-FIELD PROBE CALIBRATION REPORT DATE: 14/11/2008 REFERENCE: SN 37/08 EP80 OBJECT: COMOSAR SEPT ISOTROPIC E-FIELD PROBE MANUFACTURER: SATIMO SERIAL NUMBER: SN 37/08 EP80 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 2 3/09/2009 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this …

Text truncated - open the document above for the full version.

Contact Information

Applicant

ManWai Ho(Senior Electronics Engineer)
[email protected]852-90286560Fax: 852-90286561

Test Firm

Shenzhen Morlab Communications Technology Co.,LtdShu Luan
[email protected]0086-0755-86113898Fax: 0086-0755-86130218

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz250.00 mW295KGXW0.1 ppm
Confidentiality
Long Term
Grant Notes
Power listed is EIRP for part 24 and ERP for part 22. SAR compliance for body-worn operations is restricted to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. SAR compliance for specific collocated transmitter conditions was evaluated as described in this composite filing; other collocated configurations require separate evaluation. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Part 22: Body: 0.50W/kg, Head: 0.29W/kg; Part 24: Body: 0.45W/kg, Head: 0.31W/kg. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. HAC Ratings: M3 - 2007