FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sepura Limited/
  3. XX6SEM8050H

XX6SEM8050HDMR Mobile Radio

Sepura Limited
DMR Mobile Radio - FCC ID XX6SEM8050H - Sepura Limited
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Dec 19, 2015
Application Purpose
Original Equipment
Date of Application
Dec 19, 2015
Equipment Note
DMR Mobile Radio
Frequency Range
450.00000000 - 520.00000000
Company
Sepura Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Quick Reference Guide DMR Mobile Radio DMR Mobile Radio DMR Mobile Radio For SBM8000 / SCM8000 / SEM8000 Quick Reference Guide 1 General This guide covers the basic operation of the DMR Mobile Radio. Please refer to the user guide for more detailed information on using this product. Disclaimer notice Sepura’s policy is to continually improve its products. The features and facilities described in this document were correct at publication, but are subject to change without notice. Contact Us Sepura plc. Radio House, St Andrew’s Road, Cambridge CB4 1GR United Kingdom Tel: +44 (0)1223 876000 Fax: +44 (0)1223 879000 SPR-DOC-03808/2 Original Instructions: ENGLISH © Sepura plc. 2015 All rights reserved. This document is intended for the use of Sepura plc’s customers and/or other parties only for the purposes of the agreement or arrangement under which this document is submitted, and no part of it may be reproduced or transmitted in any form or means without the prior written permission of Sepura plc. Contents Safety ............................................................................................... 2 Regulatory ...................................................................................... 4 Connectors, controls, buttons and keys ..................................... 7 Status indicators and icons .......................................................... 8 LED status indicators .......................................................... 9 Accessory information ................................................................ 10 Fist microphone ............................................................... 10 Basic operation ............................................................................. 10 Power On/Off................................................................... 10 Adjusting the volume ........................................................ 10 Selecting a Channel .......................................................... 10 Making a PTT call ............................................................. 10 Receiving a PTT call ......................................................... 11 Emergency alarm ............................................................. 11 Caring for your radio .................................................................. 12 2 DMR Mobile Radio SBM8000, SCM8000, SEM8000 Safety Read these safety instructions carefully. Attention! Sepura products are designed for use by mobile workforces, often working alone, and are intended for use in occupational and controlled conditions. It is the responsibility of the person operating the product to ensure that it is operated safely at all times, and that local laws and regulations governing the usage of Radio Frequency (RF) products are observed. Obey all signs and instructions relating to the usage to RF wireless devices. It is recommended that you obtain training on how to safely operate this product. Your personal safety could be affected if you do not understand how to operate this product correctly. This product must not be operated in environments that exceed those listed in the product technical datasheet and in the Regulatory section of the product user guide. Unauthorised modifications to the product could cause the product to become non-operational. Always use Sepura approved antenna, battery and accessories with this product. Exposure to RF energy Sepura designs and manufactures products to meet strict guidelines and international standards relating to Radio Frequency (RF) energy and the potential health risks associated with using such products. If you have any concerns about potential health risks associated with long term exposure to RF energy, you should obtain advice from your employer. RF energy interference with electronic equipment Some personal medical devices, such as hearing aids and pacemakers, can be affected by RF energy. Always consult your service provider or the manufacturer of the medical device before using RF wireless devices. Some electronic devices are sensitive to RF energy. POWER OFF your radio when operating within health care facilities or other areas that are sensitive to RF energy. Safely operating your radio Your radio is not intrinsically safe and has not been designed for use in hazardous environments such gas fumes, flammable chemicals, or blasting areas. Check the compliance ratings of this product before operating the radio in any hazardous environment. Always ensure that your radio is operating correctly before entering any environment that has a potential risk to personal safety. Safety when driving a vehicle Always obey local laws and regulations governing the operation of RF wireless devices when driving and whilst at locations. Do not operate your radio if it creates a distraction from driving safely and observing road conditions. Always POWER OFF your radio at refuelling stations and obey warning signs relating to the use of RF wireless devices in the vicinity of refuelling stations. Quick Reference Guide 3 Important safety notes about the Antenna NEVER touch the antenna when the radio is transmitting, this may cause a minor burn to the skin and may affect the operational range of the antenna. NEVER use your radio without an antenna attached. Transmitting without an antenna may damage the radio. Only use a Sepura approved antenna with your radio. The antenna should be installed and operated with a minimum distance of 1.2m to any person. Accessories Sepura products have been tested to meet strict guidelines for personal safety and operational conditions. Only accessories approved by Sepura are recommended for use with this product. Always read the instructions supplied with the accessory for additional safety instructions. The use of non-approved accessories may invalidate any product warranty. If a non-approved accessory is fitted, it may compromise the product safety ratings. Safe installation into vehicles Electronic control mechanisms …

Text truncated - open the document above for the full version.

Attestation Statements

FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 10 November 2015 FCC Part 90 Section 203 (e) (g) Declaration To whom it may concern We, Sepura plc, hereby declare that the following products covered by their relevant certifications meet the requirements of the FCC Rules, Parts 90.203(e) and (g), as applicable. Programming of these products’ transmit frequencies can be performed only by the manufacturer or by service or maintenance personnel. The operator cannot program transmit frequencies using the equipment’s external operation controls. Product FCC ID DMR Repeater XX6SER8010 DMR Repeater XX6SER8040 DMR Repeater XX6SER8050 DMR Mobile Radio XX6SEM8010 DMR Mobile Radio XX6SEM8040 DMR Mobile Radio XX6SEM8050 DMR Mobile Radio XX6SEM8010H DMR Mobile Radio XX6SEM8040H DMR Mobile Radio XX6SEM8050H DMR Two Way Radio XX6SEP8010 DMR Two Way Radio XX6SEP8040 DMR Two Way Radio XX6SEP8050 Yours faithfully, Steve Wood Verification Engineering Team Leader

Cover Letter(s)

BACL Reference: QA-FR-170-B FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 21 August 2015 FCC Authorization To whom it may concern We, Sepura plc, the undersigned, hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratory Corporation on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from Sepura plc. Yours faithfully, Steve Wood Verification Engineering Team Leader

Cover Letter(s)

BACL Reference: QA-FR-171-A FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 21 August 2015 FCC Confidential Authorization Dear Sir or Madam RE: Confidentiality Request regarding application for certification of FCC ID: XX6SEM8050H In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Sepura plc, hereby requests long-term confidential treatment of information accompanying this application as outlined below:  Block Diagram --- (Long term)  Circuit Description --- (Long term)  Schematic --- (Long term)  Parts list --- (Long term)  Tune up procedure --- (Long term) The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Yours faithfully, Steve Wood Verification Engineering Team Leader

Cover Letter(s)

FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 21 August 2015 Dear Sir or Madam RE: Extended Frequencies Justification The radio with FCC ID: XX6SEM8050H was designed to operate in the frequency bands 450-520MHz. To aid equipment authorization in other countries which accept the United States FCC Grant for Certification, Sepura plc is requesting that the FCC lists the above frequencies 450-520 MHZ, under FCC Rule Part 90 and 22 on the FCC Grant. Sepura plc attests that the radio will not be marketed to USA users with the frequency band which is not allowed by the rules Part 90 and 22. As per the FCC’s KDB634817 guidance, as an alternative to listing the exact frequencies, we acknowledge that it’s a violation of the FCC Rules if this device operates on unauthorized frequencies. Frequency Range(MHz) FCC rule part 450-454MHz Part 90 454-455MHz Part 22 456-460MHz Part 90/Part 22 460-462.5375MHz Part 90 462.7375-467.5375MHz Part 90 467.7375-470 MHz Part 90 470-512 MHz Part 90/Part 22 Please contact me if you require any additional information. Yours faithfully, Steve Wood Verification Engineering Team Leader

Cover Letter(s)

Statement of Voice Channel Support To whom it may concern We, Sepura plc, hereby declare that the following products covered by their relevant certifications are capable of supporting a voice channel and a minimum data rate of 4800 bits per second per 6.25kHz of channel bandwidth. Product FCC ID DMR Repeater XX6SER8010 DMR Repeater XX6SER8040 DMR Repeater XX6SER8050 DMR Mobile Radio XX6SEM8010 DMR Mobile Radio XX6SEM8040 DMR Mobile Radio XX6SEM8050 DMR Mobile Radio XX6SEM8010H DMR Mobile Radio XX6SEM8040H DMR Mobile Radio XX6SEM8050H DMR Two Way Radio XX6SEP8010 DMR Two Way Radio XX6SEP8040 DMR Two Way Radio XX6SEP8050 Yours faithfully, Steve Wood Verification Engineering Team Leader 10 November 2015

External Photos

Page 1 of 6 EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT– All View EUT–Top View Page 2 of 6 EUT– Bottom View EUT–Front View Page 3 of 6 EUT–Rear View EUT–Left View Page 4 of 6 EUT–Right View EUT – Desktop Mic View Page 5 of 6 EUT – Adapter View EUT – Adapter Label View Page 6 of 6 EUT – STD First Mic View EUT – Label View

ID Label/Location Info

EXHIBIT A - FCC ID LABELING AND LOCATION FCC ID Label FCC ID Label Location The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

Internal Photos

Page 1 of 8 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS EUT– Uncover View EUT– Uncover View Page 2 of 8 EUT– Uncover View EUT– Main Board Top View Page 3 of 8 EUT–Main Board Top Unshielded View EUT– Main Board Bottom View Page 4 of 8 EUT– Main Board Bottom Unshielded View EUT– Uncover View Page 5 of 8 EUT– Uncover View EUT– Display Board Top View Page 6 of 8 EUT–Display Board Bottom View EUT–LCD Top View Page 7 of 8 EUT–LCD Bottom View EUT–Filter Top View Page 8 of 8 EUT–Filter Bottom View

Test Report

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 22 and 90 TEST REPORT For Sepura plc Radio House, St. Andrews Road, Cambridge CB4 1GR UK FCC ID: XX6SEM8050H Report Type: Original Report Product Type: DMR Mobile Radio Test En gineer: Allen Qiao Re port Number: RDG150803006-00 Re port Date: 2015-11-06 Reviewed B y: Sula Huang RF Leader Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industrial Zone, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG150803006-00 FCC Part 22 and 90 Page 2 of 45 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 4 TEST METHODOLOGY .................................................................................................................................................. 4 TEST FACILITY ............................................................................................................................................................. 4 SYSTEM TEST CONFIGURATION .......................................................................................................................... 5 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 5 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 5 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 5 EXTERNAL CABLE ........................................................................................................................................................ 5 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 6 SUMMARY OF TEST RESULTS ............................................................................................................................... 7 FCC §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) ........................................................................... 8 APPLICABLE STANDARD .............................................................................................................................................. 8 FCC §2.1046 &§ 22.727 & §90.205- RF OUTPUT POWER .................................................................................. 10 APPLICABLE STANDARD ............................................................................................................................................ 10 TEST PROCEDURE ...................................................................................................................................................... 10 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 10 TEST DATA ................................................................................................................................................................ 10 FCC §2.1047 & §90.207 - MODULATION CHARACTERISTIC .......................................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 TEST PROCEDURE ...................................................................................................................................................... 12 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 12 TEST DATA ................................................................................................................................................................ 12 FCC §2.1049& §22.357 & § 22.731 &§90.209 & §90.210 – OCCUPIED BANDWIDTH & EMISSION MASK 18 APPLICABLE STANDARD ............................................................................................................................................ 18 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 19 TEST PROCEDURE ...................................................................................................................................................... 19 TEST DATA ................................................................................................................................................................ 19 FCC §2.1051& §22.861 & §90.210 - SPURIOUS EMISSIONS AT ANTENNA TERMINALS ........................... 27 APPLICABLE STANDARD ............................................................................................................................................ 27 TEST EQUIPM…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 EXHIBIT D - TEST SETUP PHOTOGRAPHS Radiated Emission View (Below 1 GHz) Desk Mounted Radiated Emission View (Above 1 GHz) Desk Mounted Page 2 of 2 Radiated Emission View (Below 1 GHz) Vehicle Mounted Radiated Emission View (Above 1 GHz) Vehicle Mounted

Contact Information

Applicant

Chris Beecham(Conformance Engineer)
[email protected]01223876000Fax: 01223879000

Test Firm

Bay Area Compliance Laboratories Corp. (Dongguan)John Chan
[email protected]86-769-86858888

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
622,9450 MHz - 520 MHz25 W7K60FXW1 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is conducted at antenna port. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. End-Users must be provided with the specific training information. A label, as described in this filing must be displayed on the device to direct users to the specific training information required for meeting RF exposure requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 1.2 m from all persons. RF exposure compliance may be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Section 1.1307(b)(3).

Other Applications from Sepura Limited

TETRA RADIO CONTROL SYSTEM - FCC ID XX6SCG2228M - Sepura Limited
XX6SCG2228M

TETRA RADIO CONTROL SYSTEM

Jan 28, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TETRA Portable Terminal with Bluetooth and WLAN - FCC ID XX6SC2028W - Sepura Limited
XX6SC2028W

TETRA Portable Terminal with Bluetooth and WLAN

Oct 18, 2021

Equipment Class

TNE - Licensed Non-Broadcast Transmitter Held to Ear
TETRA Mobile Terminal - FCC ID XX6SCG2229W - Sepura Limited
XX6SCG2229W

TETRA Mobile Terminal

Apr 15, 2021

Equipment Class

DTS - Digital Transmission System
TETRA Mobile Terminal - FCC ID XX6SCG2229 - Sepura Limited
XX6SCG2229

TETRA Mobile Terminal

Aug 19, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TETRA Portable Handheld Terminal - FCC ID XX6SC2124 - Sepura Limited
XX6SC2124

TETRA Portable Handheld Terminal

Apr 15, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter