FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sepura Limited/
  3. XX6SER8040

XX6SER8040DMR Repeater

Sepura Limited
DMR Repeater - FCC ID XX6SER8040 - Sepura Limited
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Jun 25, 2014
Application Purpose
Original Equipment
Date of Application
Jun 25, 2014
Equipment Note
DMR Repeater
Frequency Range
406.10000000 - 470.00000000
Company
Sepura Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation and Operation Guide 1 Installation and Operation Guide DMR Repeater SBR8040/SCR8040/SER8040 Installation and Operation Guide 1 General This guide contains the inst allation and basic operating instructions for the DMR Repeater models SBR8000, SCR8000 and SER8000. This guide does not c ontain information relating to the installation of accessories such as the antenna and duplexer. Refer to the installation instructions supplied with these accessories for further safety and installation instructions. Disclaimer notice Sepura’s policy is to continually improve its products. The features and facilities described in this document were correct at publication, but are subject to change without notice. Contact Us Sepura plc. Radio House, St Andrew’s Road, Cambridge CB4 1GR United Kingdom Tel: +44 (0)1223 876000 Fax: +44 (0)1223 879000 © Sepura plc. 2014 SPR-DOC-03800/1 Original Instructions: ENGLISH All rights reserved. This document is intended for the use of Sepura plc’s customers and/or other parties only for the purposes of the agreement or arrangement under which this document is submitted, and no part of it may be reproduced or transmitted in any form or means without the prior written permission of Sepura plc. Contents Safety ........................................................................................ 2 Regulatory ................................................................................ 4 Disposing of this product ............................................. 4 Technical specification ........................................................... 5 Controls, connectors and components ................................. 7 Status indicators ...................................................................... 7 Unpacking................................................................................. 8 Accessory information ............................................................ 8 Installation ................................................................................ 9 Guidelines and recommendations ................................ 9 Wall-mount bracket installation.................................... 9 Attaching the desk mount feet ................................... 10 Connections ........................................................................... 11 AC power supply ....................................................... 11 DC power supply ...................................................... 11 Antenna ................................................................... 11 Basic operation ...................................................................... 12 Power on/off ............................................................ 12 Voice and data transfer ............................................. 12 Alarm mo de ............................................................. 12 Configuring the Repeater .......................................... 12 Caring for your product......................................................... 13 Duplexer specifications ........................................................ 13 DMR Repeater SBR8000, SCR8000, SER8000 2 Safety Read these safety instructions carefully. Attention! This product is restricted fo r occupational use and is not intended or authorised for use by the general population. It is the responsibility of the person operating the product to ensure that it is operated safely at all times, and that local laws and regulations governing the usage of Radio Frequency (RF) products are observed. Users must be trained to operate this product safely. Their personal safety could be affected if they do not understand how to operate this product correctly. CAUTION! Product weighs 12.5 Kg, take care when lifting. Exposure to RF energy Sepura designs and manufactures products to meet strict guidelines and international st andards relating to Radio Frequency energy and the potential health risks associated with using such products. This product contains radio tr ansmitters and receivers that receive and transmit Radio Frequency (RF) signals when switched on. The antenna radiates RF energy only when transmitting and not in standby mode. Users should be informed of the potential health risks associated with long term exposure to RF energy by their employer. RF energy interference with electronic equipment Some personal medical devices , such as hearing aids and pacemakers, can be affected by RF energy. Always consult your service provider or the manufa cturer of the medical device before using RF wireless devices. Accessories Sepura products have been tested to meet strict guidelines for personal safety and operational conditions. Only accessories approved by Sepura are recommended for use with this product. Always read the instructions supplied with the accessory for additional safety instructions. Unauthorised modifications to the product could cause the product to become non-operational and void any product warranty. The use of non-approved accessories may invalidate any product warranty and may compromise the product safety ratings. Servicing Do not attempt to dismantle this product. Servicing and repairs to this product must be performed by trained service technicians at Se pura approved service centres. CAUTION! This product has double pole/neutral fusing. FCC NOTICE Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two co nditions: (1) This device may not cause harmful interference, a nd (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement:This equipment complies with FCC radiation exposure limits set forth for an controlled Installation and Operation Guide 3 environment. The antenna should be installed and operated wi…

Text truncated - open the document above for the full version.

Cover Letter(s)

Date: 2014-06-04 FCC Authorisation FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorisation To whom it may concern: We, Sepura plc , the undersigned, Hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This authorization is valid until further written notice from the applicant. Sincerely, Company Officer: Steve Wood Telephone Number: +44 (01223) 877354 Email: [email protected] Position: Verification Engineering Team leader

Cover Letter(s)

--- (Long term)  ietary information not ion will not be made before Date: 2014-06-04 FCC Confidential Authorization FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request regarding application for certification of FCC ID: XX6SER8040 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below:  Detailed Circuit Schematics of EUT--- (Long term)  Block Diagram--- (Long term)  Circuit Description--- (Long term) The above materials contain trade secrets and propr customarily released to the public. The public dis closure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentat the date of the Grant for this application. Sincerely, Company Officer: Steve Wood Telephone Number: +44 (01223) 877354 Email: [email protected] Position: Verification Engineering Team leader Part List  Tune up --- (Long term)

Cover Letter(s)

The DMR Repeater with FCC ID: XX6SER8040 was design 467.7357-470MHz FCC Part 90 462.7375-467.5375MHz FCC Part 90 456-460MHz FCC Part 22/ FCC Part 90 454-455MHz FCC Part 22 450-454MHz FCC Part 90 allowed by the rule part 22 and 90. and 90 quencies 400~470MHz, under FCC Rule Parts 22 Date: 2014-01-14 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Subject: Extended Frequency Justification Dear Sir/Madam, ed to operate in the frequency bands 400~470MHz To aid equipment authorization in other countries which accept the United States FCC Grant for Certification, Sepura plc is requesting that the FCC lists the fre on the FCC Grant. Sepura plc attests that the DMR Repeater will not be marketed to USA users with the frequency band which is not FCC’s KDB634817 guidance, as an alternative to lis ting the exact frequencies, we acknowledge that it’s a violation of the FCC Rules if this device operates on unauthorized frequencies. Frequency Range(MHz) FCC Rule Part 406.1-450 MHz FCC Part 90 460-462.5375MHz FCC Part 90 Also, equipment programming is the responsibility of Authorized Service Personnel, the DMR Repeater complies with 47 CFR Part 90.203(e), in that the operator cannot directly program the transmit frequencies using the normally accessible external controls. Sincerely: Company Officer: Steve Wood Telephone Number: +44 (01223) 877354 Email: [email protected] Position: Verification Engineering Team leader Per the

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT –Top View EUT – Bottom View EUT – Left Side View EUT – Right Side View EUT – Port Side View

ID Label/Location Info

EXHIBIT A - FCC ID LABELING AND LOCATION FCC ID Label FCC ID Label Location The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Label here

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS EUT – Front Cover Off View EUT – Rear Cover Off View EUT – Main Board Top With Shielding View EUT – Main Board Top Without Shielding View EUT – Main Board Bottom With Shielding View EUT – Main Board Bottom Without Shielding View EUT –Transmitter Board Top View EUT –Transmitter Board Bottom View EUT – Receiver Board Top View EUT – Receiver Board Bottom View EUT – I/O Board Top View EUT – I/O Board Bottom View EUT – LED Board Top View EUT – LED Board Bottom View EUT – Power Supply Label View EUT – Power Filter View EUT – Power Switch Board Top View EUT–Power Switch Board Bottom View

Test Report

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP*, or any agency of the Federal Government. * This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk “★” (Rev.2), This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 22 and 90 TEST REPORT For Sepura plc Radio House, St. Andrews Road, Cambridge CB4 1GR UK FCC ID: XX6SER8040 Report Type: Original Report Product Type: DMR Repeater Test Engineer: Leon Chen Report Number: R2DG131115009-00 Report Date: 2014-06-25 Reviewed By: Ivan Cao RF Leader Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industrial Zone, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: R2DG131115009-00 FCC Part 22 and 90 Page 2 of 43 TABLE OF CONTENTS GENERAL INFORMATION.......................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................4 OBJECTIVE...................................................................................................................................................................4 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................4 TEST METHODOLOGY..................................................................................................................................................4 TEST FACILITY.............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ..........................................................................................................................6 DESCRIPTION OF TEST CONFIGURATION......................................................................................................................6 EQUIPMENT MODIFICATIONS.......................................................................................................................................6 BLOCK DIAGRAM OF TEST SETUP................................................................................................................................6 SUMMARY OF TEST RESULTS...............................................................................................................................7 FCC §1.1310 - MAXIMUM PERMISSIBLE EXPOSURE (MPE)...............................................................................8 APPLICABLE STANDARD..............................................................................................................................................8 FCC §2.1046 &§ 22.727 & §90.205- RF OUTPUT POWER ....................................................................................9 APPLICABLE STANDARD..............................................................................................................................................9 TEST PROCEDURE........................................................................................................................................................9 TEST EQUIPMENT LIST AND DETAILS...........................................................................................................................9 TEST DATA..................................................................................................................................................................9 FCC §2.1047 & §90.207 - MODULATION CHARACTERISTIC ..........................................................................11 APPLICABLE STANDARD............................................................................................................................................11 TEST PROCEDURE......................................................................................................................................................11 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................11 TEST DATA................................................................................................................................................................11 FCC §2.1049& §22.357 & § 22.731 &§90.209 & §90.210 – OCCUPIED BANDWIDTH & EMISSION MASK15 APPLICABLE STANDARD............................................................................................................................................15 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................16 TEST DATA................................................................................................................................................................16 FCC §2.1051 & §22.861 & §90.210 - SPURIOUS EMISSIONS AT ANTENNA TERMINALS ..........................21 APPLICABLE STANDARD............................................................................................................................................21 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................21 TEST PROCEDURE.....................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Radiated Emission View (Below 1 GHz) Radiated Emissions View (Above 1 GHz)

Contact Information

Applicant

Chris Beecham(Conformance Engineer)
[email protected]01223876000Fax: 01223879000

Test Firm

Bay Area Compliance Laboratories Corp. (Dongguan)John Chan
[email protected]86-769-86858888

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
622,9406.1 MHz - 470 MHz40 W9K50FXW0.61 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is conducted at antenna port. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. End-Users must be provided with the specific training information. A label, as described in this filing must be displayed on the device to direct users to the specific training information required for meeting RF exposure requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 100 cm from all persons. RF exposure compliance may be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Section 1.1307(b)(3).

Other Applications from Sepura Limited

TETRA RADIO CONTROL SYSTEM - FCC ID XX6SCG2228M - Sepura Limited
XX6SCG2228M

TETRA RADIO CONTROL SYSTEM

Jan 28, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TETRA Portable Terminal with Bluetooth and WLAN - FCC ID XX6SC2028W - Sepura Limited
XX6SC2028W

TETRA Portable Terminal with Bluetooth and WLAN

Oct 18, 2021

Equipment Class

TNE - Licensed Non-Broadcast Transmitter Held to Ear
TETRA Mobile Terminal - FCC ID XX6SCG2229W - Sepura Limited
XX6SCG2229W

TETRA Mobile Terminal

Apr 15, 2021

Equipment Class

DTS - Digital Transmission System
TETRA Mobile Terminal - FCC ID XX6SCG2229 - Sepura Limited
XX6SCG2229

TETRA Mobile Terminal

Aug 19, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TETRA Portable Handheld Terminal - FCC ID XX6SC2124 - Sepura Limited
XX6SC2124

TETRA Portable Handheld Terminal

Apr 15, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter