FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sepura Limited/
  3. XX6SRG3900UW

XX6SRG3900UWTETRA Mobile/Gateway Terminal

Sepura Limited
TETRA Mobile/Gateway Terminal - FCC ID XX6SRG3900UW - Sepura Limited
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Mar 29, 2010
Application Purpose
Original Equipment
Date of Application
Mar 29, 2010
Equipment Note
TETRA Mobile/Gateway Terminal
Frequency Range
450.00000000 - 470.00000000
Company
Sepura Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

sepura TETRA Terminals Product Guide MOD-10-1164 Issue 1 © SEPURA PLC 2010 MOD-10-1164 sepura TETRA Terminals Product Guide March 26 th 2010 Page 2 of 35 Issue 1 © Sepura plc 2010 Contents CONVENTIONS _______________________________________________ 4 REGULATORY STATEMENTS ___________________________________ 5 SRG3900 terminals _________________________________________________________ 5 STP8040/STP8140 terminals _________________________________________________ 6 OPERATIONAL REQUIREMENTS ________________________________ 7 Operating Conditions _______________________________________________________ 7 HANDHELD TERMINAL RANGE _________________________________ 8 STP8000, STP8100 _________________________________________________________ 9 SRH3500, SRH3800, SRH3900 _______________________________________________ 19 MOBILE / GATEWAY TERMINAL RANGE _________________________ 24 SRM3000, SRG3000 Mobile / Gateway Transceiver _____________________________ 25 Standard Console _________________________________________________________ 26 Handset Based Console ___________________________________________________ 26 Applications Interface Unit _________________________________________________ 27 Mobile / Gateway Terminal Accessories ______________________________________ 28 Mobile / Gateway Terminal Audio Control _____________________________________ 28 RADIO OPERATION __________________________________________ 30 HEALTH AND SAFETY ________________________________________ 31 User Information __________________________________________________________ 31 Compliance with Standards ________________________________________________ 32 GLOSSARY _________________________________________________ 33 ACKNOWLEDGEMENTS ______________________________________ 34 MOD-10-1164 sepura TETRA Terminals Product Guide March 26 th 2010 Page 3 of 35 Issue 1 © Sepura plc 2010 NOTICE ____________________________________________________ 35 Contact Details ___________________________________________________________ 35 MOD-10-1164 sepura TETRA Terminals Product Guide March 26 th 2010 Page 4 of 35 Issue 1 © Sepura plc 2010 CONVENTIONS This guide uses the following formatting and graphical conventions. Convention Description Note icon. Emphasises related, reinforcing, or important information. Tip icon. Suggests alternative methods for accomplishing tasks or procedures. Caution icon. Indicates actions or processes that require caution from the user. MOD-10-1164 sepura TETRA Terminals Product Guide March 26 th 2010 Page 5 of 35 Issue 1 © Sepura plc 2010 REGULATORY STATEMENTS The following regulatory statements apply to users in the North American and/or Canadian markets. SRG3900 TERMINALS Changes or modifications not expressly approved by the party responsible for compliance could void the user‟s authority to operate the equipment (FCC rule part 15.21). This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. (FCC Rule Part 15.19(a)(3)). NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense (FCC Rule Part 15.105). When used with the High Gain Tetra Modular Whip antenna (maximum antenna gain 7dBi), the antenna must be installed to provide a separation distance of at least 31 cm from all persons during normal operation to ensure compliance for RF Exposure. When used with the rigid Tetra Modular Whip antenna (maximum antenna gain 2dBi), the antenna must be installed to provide a separation distance of at least 25 cm from all persons during normal operation to ensure compliance for RF Exposure. This Class A digital apparatus complies with Canadian ICES-003. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication This radio is intended for use in occupational/controlled applications where users have been made aware of the potential for exposure and can exercise control over their exposure. This radio device is NOT authorized for general population, consumer or similar use. MOD-10-1164 sepura TETRA Terminals Product Guide March 26 th 2010 Page 6 of 35 Issue 1 © Sepura plc 2010 STP8040/STP8140 TERMINALS Changes or modifications not expressly approved by the party responsible for compliance could void the user‟s authority to operate the equipment (FCC rule part 15.21). This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. (FCC Rule Part 15.19(a)(3)). NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of th…

Text truncated - open the document above for the full version.

Cover Letter(s)

Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. Date 26 th January 2010 BABT TCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Confidentiality Request Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, Sepura plc hereby requests permanent confidential treatment of information accompanying this application as outlined below: BOM’s Circuit Diagrams Circuit Descriptions Operating Descriptions Block Diagrams The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Bob Allen Telephone Number: +44 (0) 1223 876000 Email: [email protected]

External Photos

FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW Front View SRG3900 UW Rear View FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW Bottom FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW Side View 1 SRG3900 UW Side View 2 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 AIU 300-00217 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 Colour Console 300-00771 SRG3900 Mono Console 300-00149 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 RSM 300 00444 SRG3900 Fist Mic 300 00062 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 HBC 300-00669 SRG3900 Handset 300-00061 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 Hands Free

ID Label/Location Info

Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW Top (Label)

Internal Photos

FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW Colour Console PCB 300-00771 SRG3900 UW Colour Console Internal 300-00771 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW Mono Console Internal 300-00149 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW Handset Internal 300-00061 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW Fist Mic Internal 300 00062 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW PCB 1 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW PCB 2 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW RSM PCB 300 00444 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW RSM open 300 00444 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW HBC PCB 300-00669 FCC ID: XX6SRG3900UW IC ID: 8739A-SRG3900UW SRG3900 Vehicle Mounted Tetra Radio Job Number 75908189 Sepura plc Radio House, St Andrew’s Road, Cambridge CB4 1GR, UK Tel: +44 (0) 1223 876000 Fax: +44 (0) 1223 879000 www.sepura.com Sepura plc Registered in England No: 4353801 Registered office: Radio House, St Andrew’s Road, Cambridge CB4 1GR, England. SRG3900 UW HBC Internal 300-00669

RF Exposure Info

Document 75908189 Report 03 Issue 2 March 2010 Report On RF Exposure Assessment of the Sepura plc SRG3900 with ACUHB Antenna FCC ID: XX6SRG3900UW Industry Canada ID: 8739A-SRG3900UW TUV Product Service Ltd, Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, United Kingdom, PO15 5RL Tel: +44 (0) 1489 558100. Website: www.tuvps.co.uk Document 75908189 Report 03 Issue 2 Page 1 of 22 This report has been up-issued to Issue 2 to include the FCC and Industry Canada IDs. REPORT ON RF Exposure Assessment of the Sepura plc SRG3900 with ACUHB Antenna Document 75908189 Report 03 Issue 2 March 2010 PREPARED FOR Sepura plc Radio House St Andrews Road Cambridge CB4 1GR PREPARED BY M Whiting Project Manager APPROVED BY T J Pither Authorised Signatory DATED 10 March 2010 Document 75908189 Report 03 Issue 2 Page 2 of 22 CONTENTS Section Page No 1 REPORT SUMMARY ................................................................................................................... 3 1.1 Introduction ................................................................................................................................... 4 1.2 Brief Summary of Results ............................................................................................................. 5 1.3 Product Information ...................................................................................................................... 7 1.4 Summary ...................................................................................................................................... 7 2 TEST DETAILS ............................................................................................................................ 8 2.1 Rationale for Assessment of the RF Exposure ............................................................................ 9 2.2 Defined Limits ............................................................................................................................. 10 2.3 Establishing Wavelength and 1/4 Wavelength ........................................................................... 10 2.4 Far Field Calculations ................................................................................................................. 11 2.5 Field Regions .............................................................................................................................. 11 3 FIGURES .................................................................................................................................... 12 3.1 Field Representations – ICNIRP ................................................................................................ 13 3.2 Field Representations – FCC ..................................................................................................... 15 3.3 Field Representations – IC ......................................................................................................... 17 3.4 Field Representations – ACMA .................................................................................................. 19 4 DISCLAIMERS AND COPYRIGHT ........................................................................................... 21 4.1 Disclaimers and Copyright .......................................................................................................... 22 Document 75908189 Report 03 Issue 2 Page 3 of 22 SECTION 1 REPORT SUMMARY RF Exposure Assessment of the Sepura plc SRG3900 with ACUHB Antenna Document 75908189 Report 03 Issue 2 Page 4 of 22 1.1 INTRODUCTION The information contained in this report is intended to show verification of the RF Exposure Assessment of the Sepura plc SRG3900 with ACUHB Antenna to the requirements of the applied test specifications. Objective To perform RF Exposure Assessment to determine the Equipment Under Test's (EUT’s) compliance of the applied rules. Applicant Sepura plc Manufacturer Sepura plc Manufacturing Description SRG3900 with ACUHB Antenna Model Number(s) SRG3900 Test Specification/Issue/Date 1. EN62311:2008 - Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz). 2. OET Bulletin 65 Edition 97-01 August 1997 - Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields 3. RSS-102 Issue 2 November 2005 Radio Frequency Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) 4. Radiocommunications (Electromagnetic Radiation – Human Exposure) Standard 2003 Related Document(s) 5. Council Recommendation 1999/519/EC of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (Official Journal L 197 of 30 July1999). 6. FCC Guidelines for Evaluating exposure to RF Emissions - 47 CFR § 1.1310; 47 CFR § 1.1307(b) & 47 CFR § 80.83. 7. Health Canada's Safety Code 6: Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3 KHz to 300 GHz. 8. ARPANSA, ‘Radiation Protection Standard – Maximum Exposure Levels to Radiofrequency Fields – 3KHz to 300GHz’ 9. ICNIRP 1998,’Guidelines for limiting exposure to time-varying electric magnetic and electromagnetic fields (up to 300GHz). Guidelines of the International Commission on Non-Ionizing Radiation Protection’, Health Physics, vol.74, no.4, pp.494-522. 10. National Council on Radiation Protection and Measurements (NRPC) - Report No. 86(1986) "Biological Effects and Exposure Criteria for Radio frequency Electromagnetic Fields". 11. EN 50383:2002 - Basic standard for the calculation and measurement of electromagnetic field strength and SAR related to human exposure from radio base stations and fixed terminal stations for wireless telecommunication systems (110 MHz - 40 GHz). Document 75908189 Report 03 Issue 2 Page 5 of 22 12. IEEE Std C95.1-2005: IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic F…

Text truncated - open the document above for the full version.

RF Exposure Info

Document 75908189 Report 04 Issue 2 March 2010 Report On RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna FCC ID: XX6SRG3900UW Industry Canada ID: 8739A-SRG3900UW TUV Product Service Ltd, Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, United Kingdom, PO15 5RL Tel: +44 (0) 1489 558100. Website: www.tuvps.co.uk Document 75908189 Report 04 Issue 2 Page 1 of 22 This report has been up-issued to Issue 2 to include the FCC and Industry Canada IDs. REPORT ON RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna Document 75908189 Report 04 Issue 2 March 2010 PREPARED FOR Sepura plc Radio House St Andrews Road Cambridge CB4 1GR PREPARED BY M Whiting Project Manager APPROVED BY T J Pither Authorised Signatory DATED 10 March 2010 Document 75908189 Report 04 Issue 2 Page 2 of 22 CONTENTS Section Page No 1 REPORT SUMMARY ................................................................................................................... 3 1.1 Introduction ................................................................................................................................... 4 1.2 Brief Summary of Results ............................................................................................................. 5 1.3 Product Information ...................................................................................................................... 7 1.4 Summary ...................................................................................................................................... 7 2 TEST DETAILS ............................................................................................................................ 8 2.1 Rationale for Assessment of the RF Exposure ............................................................................ 9 2.2 Defined Limits ............................................................................................................................. 10 2.3 Establishing Wavelength and 1/4 Wavelength ........................................................................... 10 2.4 Far Field Calculations ................................................................................................................. 11 2.5 Field Regions .............................................................................................................................. 11 3 FIGURES .................................................................................................................................... 12 3.1 Field Representations – ICNIRP ................................................................................................ 13 3.2 Field Representations – FCC ..................................................................................................... 15 3.3 Field Representations – IC ......................................................................................................... 17 3.4 Field Representations – ACMA .................................................................................................. 19 4 DISCLAIMERS AND COPYRIGHT ........................................................................................... 21 4.1 Disclaimers and Copyright .......................................................................................................... 22 Document 75908189 Report 04 Issue 2 Page 3 of 22 SECTION 1 REPORT SUMMARY RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna Document 75908189 Report 04 Issue 2 Page 4 of 22 1.1 INTRODUCTION The information contained in this report is intended to show verification of the RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna to the requirements of the applied test specifications. Objective To perform RF Exposure Assessment to determine the Equipment Under Test's (EUT’s) compliance of the applied rules. Applicant Sepura plc Manufacturer Sepura plc Manufacturing Description SRG3900 with AQHB Antenna Model Number(s) SRG3900 with AQHB Antenna Test Specification/Issue/Date 1. EN62311:2008 - Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz). 2. OET Bulletin 65 Edition 97-01 August 1997 - Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields 3. RSS-102 Issue 2 November 2005 Radio Frequency Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) 4. Radiocommunications (Electromagnetic Radiation – Human Exposure) Standard 2003 Related Document(s) 5. Council Recommendation 1999/519/EC of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (Official Journal L 197 of 30 July1999). 6. FCC Guidelines for Evaluating exposure to RF Emissions - 47 CFR § 1.1310; 47 CFR § 1.1307(b) & 47 CFR § 80.83. 7. Health Canada's Safety Code 6: Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3 KHz to 300 GHz. 8. ARPANSA, ‘Radiation Protection Standard – Maximum Exposure Levels to Radiofrequency Fields – 3KHz to 300GHz’ 9. ICNIRP 1998,’Guidelines for limiting exposure to time-varying electric magnetic, and electromagnetic fields (up to 300GHz). Guidelines of the International Commission on Non-Ionizing Radiation Protection’, Health Physics, vol.74, no.4, pp.494-522. 10. National Council on Radiation Protection and Measurements (NRPC) - Report No. 86(1986) "Biological Effects and Exposure Criteria for Radio frequency Electromagnetic Fields". 11. EN 50383:2002 - Basic standard for the calculation and measurement of electromagnetic field strength and SAR related to human exposure from radio base stations and fixed terminal stations for wireless telecommunication systems (110 MHz - 40 GHz). Document 75908189 Report 04 Issue 2 Page 5 of 22 12. IEEE Std C95.1-2005: IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Ele…

Text truncated - open the document above for the full version.

Test Report

Document 75908189 Report 01 Issue 1 March 2010 Report On FCC Testing of the Sepura plc SRG3900 Vehicle Mounted Tetra Radio In accordance with FCC CFR 47 Part 90 COMMERCIAL-IN-CONFIDENCE FCC ID: XX6SRG3900UW TUV Product Service Ltd, Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, United Kingdom, PO15 5RL Tel: +44 (0) 1489 558100. Website: www.tuvps.co.uk COMMERCIAL-IN-CONFIDENCE Document 75908189 Report 01 Issue 1 Page 1 of 63 APPROVED BY M J Hardy Authorised Signatory C Gould Authorised Signatory ENGINEERING STATEMENT The measurements shown in this report were made in accordance with the procedures described on test pages. All reported testing was carried out on a sample equipment to demonstrate limited compliance with FCC CFR 47 Part 90. The sample tested was found to comply with the requirements defined in the applied rules. Test Engineers; R A Blagg G Lawler REPORT ON FCC Testing of the Sepura plc SRG3900 Vehicle Mounted Tetra Radio In accordance with FCC CFR 47 Part 90 Document 75908189 Report 01 Issue 1 March 2010 PREPARED FOR Sepura plc Radio House St Andrew’s Road Cambridge CB4 1GR PREPARED BY N Bennett Senior Administrator DATED 11 March 2010 Document 75908189 Report 01 Issue 1 Page 2 of 63 CONTENTS Section Page No 1 REPORT SUMMARY ................................................................................................................... 3 1.1 Introduction ................................................................................................................................... 4 1.2 Brief Summary of Results ............................................................................................................. 5 1.3 Declaration of Build Status ........................................................................................................... 6 1.4 Product Information ...................................................................................................................... 7 1.5 Test Conditions ............................................................................................................................. 9 1.6 Deviations from the Standard ....................................................................................................... 9 1.7 Modification Record ...................................................................................................................... 9 2 TEST DETAILS .......................................................................................................................... 10 2.1 Emission Masks .......................................................................................................................... 11 2.2 Effective Radiated Power ........................................................................................................... 36 2.3 Power and Antenna Height Limits .............................................................................................. 38 2.4 Types of Emission / Types of Modulation ................................................................................... 40 2.5 Bandwidth Limitations ................................................................................................................. 42 2.6 Emission Mask ............................................................................................................................ 45 2.7 Frequency Stability ................................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Chris Beecham(Conformance Engineer)
[email protected]01223876000Fax: 01223879000

Test Firm

TUV SUD Product ServiceMark Jenkins
[email protected]00-44-1489-558258Fax: 00-44-1489-558101

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
190450 MHz - 470 MHz8.29 W25K0Q1D1.3400000000 ppm
Confidentiality
Long Term
Grant Notes
Reissued by FCC

Other Applications from Sepura Limited

TETRA RADIO CONTROL SYSTEM - FCC ID XX6SCG2228M - Sepura Limited
XX6SCG2228M

TETRA RADIO CONTROL SYSTEM

Jan 28, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TETRA Portable Terminal with Bluetooth and WLAN - FCC ID XX6SC2028W - Sepura Limited
XX6SC2028W

TETRA Portable Terminal with Bluetooth and WLAN

Oct 18, 2021

Equipment Class

TNE - Licensed Non-Broadcast Transmitter Held to Ear
TETRA Mobile Terminal - FCC ID XX6SCG2229W - Sepura Limited
XX6SCG2229W

TETRA Mobile Terminal

Apr 15, 2021

Equipment Class

DTS - Digital Transmission System
TETRA Mobile Terminal - FCC ID XX6SCG2229 - Sepura Limited
XX6SCG2229

TETRA Mobile Terminal

Aug 19, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TETRA Portable Handheld Terminal - FCC ID XX6SC2124 - Sepura Limited
XX6SC2124

TETRA Portable Handheld Terminal

Apr 15, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter