Equipment Note
ELECTROMOTION JACK REMOTE CONTROLLER
Frequency Range
315.00000000 - 315.00000000
Company
Hangzhou Henghong Machinery Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

manual Instruction The controller contains four buttons:UP,DOWN,LOCK,UNLOCK ,and the working frequency is 315MHZ ,the voltage is DC 12V,it can be used with any kinds of the decoding function receiver module together.It can do the corresponding control after the decoding puted out.It adopt singlechip to read the receiver single and decode data,then use the decoding control the motor . FCC NOTE : The Manufacturer Is Not Responsible For Any Radio Or Tv Interference Caused By Unauthorized Modifications To This Equipment. Such Modifications Could Void The User’S Authority To Operate The Equipment This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation 第 1 页

Block Diagram

Resonator 315M Hz

ID Label/Location Info

FCC ID LABEL FCC ID: Y43ZDJS4 This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:1. This device may not cause harmful interference, and 2. This device must accept any interference received,including interference that may cause undesired operation. Label Location on EUT EUT Bottom View/ FCC ID Label Location

Operational Description

Circuit diagram description Circuit diagram description: The circuit diagram contain four order keys,command coding electrocircuit,modulator circuit,drive circuit,surface acoustic frequency stabilized circuit and transmission circuit.There is command coding single appear in the command coding electrocicuit,and it will modulate the putout single,and then the drive circuit will make it powermagnification,after the surface acoustic crystal oscillator frequency stabilized the transmission circuit will put out the modulated command coding single. 第 1 页

Test Report

FCC PART 15.231 EMI MEASUREMENT AND TEST REPORT For Hangzhou Henghong Machinery Co., Ltd Hongken Agriculture Plant, Xiaoshan, Hangzhou, Zhejiang, China FCC ID: Y43ZDJS4 Dec 28, 2010 This Report Concerns: Original Report Equipment Type: Electromotion Jack Remote Controller Test Engineer: Eric Li Report No.: BST10120386R-3 Receive EUT Date/Test Date: Dec 20, 2010/ Dec 20- Dec 28,2010 Reviewed By: Christina Prepared By: Shenzhen BST Technology Co.,Ltd. 3F,Weames Technology Building, No. 10 Kefa Road,Science Park, Nanshan District,Shenzhen,Guangdong,China Tel: 0755-26747751~3 Fax: 0755-26747751~3 ext.826 Note: The test report is specially limited to the above company and this particular sample only. It may not be duplicated without prior written consent of Shenzhen BST Technology Co.,Ltd. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP, NIST or any agency of the US Government. Hangzhou Henghong Machinery Co., Ltd FCC ID: YI3ZDJS4 BST FCC ID REPORT : BST10120386R-3 Page 2/15 TABLE OF CONTENTS 1. GENERAL INFORMATION ....................................................................................................3 1.1. Report information ............................................................................................................3 1.2. Measurement Uncertainty .................................................................................................3 2. PRODUCT DESCRIPTION ......................................................................................................4 2.1. EUT Description ...............................................................................................................4 2.2. Block Diagram of EUT Configuration..............................................................................4 2.3. Support Equipment List ....................................................................................................4 2.4. Test Conditions .................................................................................................................4 3. FCC ID LABEL...........................................................................................................................5 4. TEST RESULTS SUMMARY ...................................................................................................6 Modifications ................................................................................................................................6 5. TEST EQUIPMENT USED .......................................................................................................7 6. CONDUCTED POWER LINE TEST .......................................................................................8 6.1. Test Equipment .................................................................................................................8 6.2. Test Procedure ..................................................................................................................8 6.3. Test Setup..........................................................................................................................8 6.4. Configurating of the EUT .................................................................................................8 6.5. EUT Operating Condition...............................................................................................10 6.6. Conducted Power line Emission Limits..........................................................................10 6.7. Conducted Power Line Test Result.................................................................................10 7. RADIATION EMISSIONS ......................................................................................................11 7.1. Test Equipment ...............................................................................................................11 7.2. Test Procedure ................................................................................................................11 7.3. Radiated Test Setup ........................................................................................................11 7.4. Radiated Emission Limit.................................................................................................11 7.5. Radiated Emission Test Result .......................................................................................12 8. 20B BANDWIDTH....................................................................................................................13 8.1. Test Equipment ...............................................................................................................13 8.2. Test Procedure ................................................................................................................13 8.3. FCC 15.231(c) 20B Bandwidth Limit.............................................................................13 8.4. Test Result ......................................................................................................................13 9. DEACTIVATION TESTING...................................................................................................14 9.1. Test Equipment ...............................................................................................................14 9.2. Test Procedure ................................................................................................................14 9.3. Deactivation Requirement ..............................................................................................14 9.4. Test Result ......................................................................................................................14 10. ANTENNA REQUIREMENT .................................................................................................15 10.1. STANDARD APPLICABLE..........................................................................................15 10.…

Text truncated - open the document above for the full version.

Contact Information

Applicant

QUAN YUAN ZHU(Manager)
[email protected](86) 571-82640597Fax: (86) 571-82645539

Test Firm

emitel (Shenzhen) LimitedLouis Lin
[email protected]8675583182012Fax: 8675583123810

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231315 MHz - 315 MHz-