Y6T-PC1501Public alert controller, EAS Encoder/Decoder

Communications Laboratories Inc
Public alert controller, EAS Encoder/Decoder - FCC ID Y6T-PC1501 - Communications Laboratories Inc
Click to zoom

Application Details

Equipment Class
EAD - Part 11 Emergency Alert Devices
Date of Grant
Mar 30, 2011
Application Purpose
Original Equipment
Date of Application
Mar 30, 2011
Equipment Note
Public alert controller, EAS Encoder/Decoder
Company
Communications Laboratories Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—

Schematics

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PAC Public Alert Controller EAS Encoder/Decoder Model PC1501-01 Software Version 1.0 User Manual Version 000 Comlabs, Inc. 750 North Drive Melbourne, FL 32934 www.comlabs.com 2 | P a g e FCC Information: FCC ID: Y6T-PC1501 The Comlabs Public Alert Controller complies with Part 11 of the FCC Rules. It is has been certified as an EAS Encoder and Decoder. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Copyright Β© 2010, 2011 Communications Laboratories, Inc. All Right Reserved All other Trademarks are hereby acknowledged Sales & Support: www.comlabs.com (321) 409-9898 3 | P a g e Table of Contents 1 Input Setup ............................................................................................................................................ 4 1.1 Audio Inputs .................................................................................................................................. 4 1.1.1 Radio Input Configuration .................................................................................................... 4 1.1.2 Audio Input Configuration .................................................................................................... 6 1.2 CAP Inputs .................................................................................................................................... 7 1.2.1 CAP Input Configuration – EMnet ....................................................................................... 8 1.2.2 CAP Input Configuration – URL .......................................................................................... 8 1.2.3 CAP Input Configuration - Directory ................................................................................... 9 1.3 General Purpose Inputs (GPI) ..................................................................................................... 11 1.3.1 General Purpose Input Configuration ................................................................................. 11 2 Output Setup ....................................................................................................................................... 12 2.1 Audio Outputs ............................................................................................................................. 12 2.1.1 XLR ..................................................................................................................................... 12 2.1.2 Internal Speaker .................................................................................................................. 12 2.1.3 Additional Audio Devices ................................................................................................... 13 2.2 General Purpose Outputs (GPO) ................................................................................................. 13 2.2.1 General Purpose Output Configuration ............................................................................... 13 3 Alert System Setup ............................................................................................................................. 14 3.1 Add a New System ...................................................................................................................... 14 3.1.1 System Description ............................................................................................................. 14 3.1.2 Coverage Area..................................................................................................................... 15 3.1.3 Alert Devices ...................................................................................................................... 15 3.1.4 Station Calendar .................................................................................................................. 16 3.1.5 GPO Device Control ........................................................................................................... 18 3.1.6 Alert Rules .......................................................................................................................... 18 4 | P a g e 1 Input Setup 1.1 Audio Inputs The PAC includes six audio inputs for simultaneous monitoring of EAS alert sources. This includes three built-in radio receivers and three audio inputs for additional audio sources. 1.1.1 Radio Input Configuration The PAC has three built in radio receivers that can be tuned to any FM or NOAA WX frequency (87.5 – 107.9, 162.400, 162.425, 162.450, 162.475, 162.500, 162.525, and 162.550) for monitoring of alerts. 1.1.1.1 Radio Input Description You will begin setup by assigning a unique description for the radio input. This description will appear on the control panel as the label for the corresponding input tab. We recommend that you make your description as specific as possible because it will help operators and engineers easily identify the input during operation, setup, and troubleshooting. If possible, we a…

Text truncated - open the document above for the full version.

ID Label/Location Info

Communications Laboratories, Inc. 750 North Drive Melbourne, FL 32934 (321) 409-9898 www.comlabs.com Model: PC1501-01 S/N: This device complies with Part 11 of the FCC Rules. FCC ID: Y6T-PC1501 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This devices may not cause harmful interference, and (2) This device must accept any interference received, including interence that may cause undesired operation.

Schematics

Schematics not required for Part 11 11711 From: Terre Wolak Intertek Sent: Thursday, January 27, 2011 10:46 AM To:'Tom Rodby' Subject:FW: Part 11 Tom, Schematics are not required. Terre Terre Wolak Β€ EMC Administrative Assistant/TCB Admin IntertekPhone: 678.775.2421 Fax: 678.775.2401 [email protected] (EMC) [email protected] Β€(TCB) www.interteketlsemko.com Β€ ______________________________________________ From: Yuriy Litvinov Intertek Sent: Thursday, January 27, 2011 10:36 AM To:Terre Wolak Intertek Subject:RE: Part 11 Terre, There are two "Notes 3" on pages 5 and 8. It should read on page 5: Not required for Part 11 application. It should read on page 8: Not required for Part 11 application. However, a parts list should be provided if component values are not visible on the schematic diagram. (YL. Second sentences is FCC guidance). Regards, Yuriy. _____________________________________________ From: Terre Wolak Intertek Sent: Wednesday, January 26, 2011 3:11 PM To:Yuriy Litvinov Intertek Subject:Part 11 Yuriy, Is it true that schematics are not required for a Part 11 certification. The following is noted on page 5 of the Users Guide. I don't understand the statement below. NOTE 3: Not required for Part 11, 15 or 18 applications. However, a parts list should be provided if component values are not visible on the schematic diagram. Thanks for your help. Terre Terre Wolak Β€ Page 1 Schematics not required for Part 11 11711 EMC Administrative Assistant/TCB Admin IntertekPhone: 678.775.2421 Fax: 678.775.2401 [email protected] (EMC) [email protected] Β€(TCB) www.interteketlsemko.com Β€ Page 2

Test Report

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. FCC Part 11 Subpart B Report for Comlabs on the PAC Page 1 of 41 FCC Part 11 Subpart B TEST REPORT Report Number: 100137947BOX-006 Project Number: G100137947 Report Issue Date: 08/25/2010 Product Designation: PAC Standards: CFR47 Telecommunications Part 11 β€œEmergency Alert System (EAS)” Subpart B Tested by: Client: Intertek Testing Services NA, Inc. 70 Codman Hill Road Boxborough, MA 01719 Comlabs 750 North Drive Melbourne, 32934 Report prepared by Report reviewed by Nicholas Abbondante Sr. Project Engineer Michael F. Murphy Staff Engineer, EMC Intertek Report Number: 100137947BOX-001 Issued: 08/25/10 FCC Part 11 Subpart B Report for Comlabs on the PAC Page 2 of 41 1 Introduction and Conclusion The tests indicated in section 2.0 were performed on the product constructed as described in section 3.0. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. 2 Test Summary Section Test full name Result 3 Client Information -- 4 Description of Equipment Under Test -- 5 System setup including cable interconnection details, support Equipment and simplified block diagram -- -- Radiated Emissions FCC 15.109 – Emissions must be below the 15.109 Class A limits Not tested by Intertek -- AC Line-Conducted Emissions FCC 15.107 – Emissions must be below the 15.107 Class A limits Not tested by Intertek 6 EAS Protocol FCC 11.31 – The EAS protocol must meet the protocol requirements of 11.31. See Test Details for a detailed list of requirements. Pass 7 EAS Encoder FCC 11.32 – The EAS encoder must meet the operational requirements of 11.32. See Test Details for a detailed list of requirements. Pass 8 EAS Decoder FCC 11.33 – The EAS decoder must meet the operational requirements of 11.33. See Test Details for a detailed list of requirements. Pass 9 Revision History -- Intertek Report Number: 100137947BOX-001 Issued: 08/25/10 FCC Part 11 Subpart B Report for Comlabs on the PAC Page 3 of 41 3 Client Information This EUT was tested at the request of: Company: Comlabs 750 North Drive Melbourne, 32934 Contact: Jared Maynard Telephone: (321) 409-9898 Ext. 305 Fax: (321) 409-9899 Email: [email protected] 4 Description of Equipment Under Test Equipment Under Test Description Manufacturer Model Number Serial Number Emergency Alert System Comlabs PAC Computer-BOX1007121343-013 Receive Date: 07/12/2010 Received Condition: Good Type: Production Description of Equipment Under Test (provided by client) Emergency Alert System Equipment Under Test Power Configuration Rated Voltage Rated Current Rated Frequency Number of Phases 120V/230V 8A/4A 50/60Hz Single Operating modes of the EUT: No. Descriptions of EUT Exercising 1 11.32(b), (c), and (d) – The EUT was operating in Encoding/Decoding/Processing loop 2 All other tests – The EUT was operating in its normal operation Intertek Report Number: 100137947BOX-001 Issued: 08/25/10 FCC Part 11 Subpart B Report for Comlabs on the PAC Page 4 of 41 5 System setup including cable interconnection details, support equipment and simplified block diagram 5.1 Method: Record the details of EUT cabling, document the support equipment, and show the interconnections in a block diagram. 5.2 EUT Block Diagram: Support Transmitter Setup EUT Setup Intertek Report Number: 100137947BOX-001 Issued: 08/25/10 FCC Part 11 Subpart B Report for Comlabs on the PAC Page 5 of 41 5.3 Cables: ID Description Length Shielding Ferrites 1 Microphone ~2m Braid None 2 AC ~2m None None 3 AC Adapter ~2m None None 4 RJ45 ~0.5m None None 5 RJ45 ~2m None None 6 USB ~2m Braid One on both ends 7 AC Adapter ~2m None None 8 AC ~2m None None 9 RJ45 ~3m None None 10 AC Adapter ~2m None None 11 AC ~2m None None 12 AC ~1m None None 13 AC ~1m None None 14 Video ~1m Braid One on both ends 15 DB9 ~0.25m Braid None 16 Mouse ~1m None None 17 Keyboard ~1m None None 18 Load ~2m None None 19 Speaker ~2m None None 20 DIN ~2m None None 21 DIN ~2m None None 22 Coaxial ~1m Coaxial None 23 AC ~2m None None 24 AC Adapter ~2m None None 25 AC ~2m None None 5.4 Support Equipment: Support Equipment Description Manufacturer Model Number Serial Number Fast Ethernet Switch NetGear FS116 FS11236LB095255 Microphone Audio-technica AT2020USB None FM Audio Transmitter MobileBlackBox V6000 None Speaker Altec Lansing Multimedia FM40043604 None Laptop Toshiba PN PSAE3U-06Y023 38354111K Laptop Toshiba PN PSAE3U-06Y023 38353990K Monitor Dell E173FPc CN-OF5035-64180-58K-2EHC Mouse Dell M-SAW34 LZC33565267 Keyboard Microsoft RT9480 6968200598410 Laptop P/S Toshiba ADP-75SB AB U8261 Laptop P/S Toshiba ADP-75SB AB U5697 NetGear P/S NetGear PWR-002-…

Text truncated - open the document above for the full version.

Test Setup Photos

Intertek Report Number: 100137947BOX-001 Issued: 08/25/10 FCC Part 11 Subpart B Report for Comlabs on the PAC Page 7 of 41 6.4 Setup Photographs: Intertek Report Number: 100137947BOX-001 Issued: 08/25/10 FCC Part 11 Subpart B Report for Comlabs on the PAC Page 25 of 41 7.4 Setup Photographs: 11.32(d): 10 V/m RF field at 1MHz 11.32(d): 0.5V/m RF field at 108MHz Intertek Report Number: 100137947BOX-001 Issued: 08/25/10 FCC Part 11 Subpart B Report for Comlabs on the PAC Page 26 of 41 PAC Front Panel Photograph: Intertek Report Number: 100137947BOX-001 Issued: 08/25/10 FCC Part 11 Subpart B Report for Comlabs on the PAC Page 35 of 41 8.4 Setup Photographs: 11.32(d): 10 V/m RF field at 1MHz 11.32(d): 0.5V/m RF field at 108MHz Intertek Report Number: 100137947BOX-001 Issued: 08/25/10 FCC Part 11 Subpart B Report for Comlabs on the PAC Page 36 of 41 Setup Photographs: PAC Front Panel

Contact Information

Applicant

Roland Lussier(CEO)
[email protected]3214099898Fax: 3214099899

Test Firm

Intertek Testing Services NA Inc.Yaqing Liu
[email protected]978 635 8662

Technical Specifications

#Rule PartsFrequency RangePower Output
111--
Confidentiality
Long Term

Other Applications from Communications Laboratories Inc

CAP to EAS Converter - FCC ID Y6T-EMNET - Communications Laboratories Inc
Y6T-EMNET

CAP to EAS Converter

Jul 14, 2013

Equipment Class

EAD - Part 11 Emergency Alert Devices