Alarm System 2 2 Table of Contents 1 OVERVIEW__________________________________________________________ 3 1.1 Introduction _________________________________________________________ 3 1.2 Basic Principle of Operation____________________________________________ 3 1.3 Component Parts_____________________________________________________5 1.4 Optional Extra Detectors available_______________________________________ 5 2 DESCRIPTION________________________________________________________ 6 2. 1 The Keypad________________________________________________________ 6 2. 2 The LCD Character details and description________________________________ 7 3 INSTALLATION INFORMATION_________________________________________ 9 3.1 The Basic Flow Chart_________________________________________________ 9 3.2 Registering Key Fobs________________________________________________ 10 3.3 Registering Sensors_________________________________________________ 10 3.4 Installing Wired Detector______________________________________________ 11 3.5 Checking Registration 3.6 Deleting Registered Key Fobs__________________________________________12 3.7 Deleting Registered Sensors___________________________________________12 3.8 The Zone Setting and Allocation________________________________________ 12 3.9 The System Configuration Setting_______________________________________13 3.10 The Phone Numbers Setting__________________________________________14 3.11 The C.S. Account Code Setting_______________________________________ 15 3.12 Deleting Zones____________________________________________________ 15 3.13 Viewing The Recording Event Log_____________________________________ 16 3.14 Setting Entry and Exit delay timer______________________________________ 18 3.15 Sounder cut off time________________________________________________ 18 3.16 View detector ’ s total in every zone_____________________________________ 19 3.17 Speak and Listen in 3.18 Record/Play the alarming Message 19 4USERINFORMATION: __________________________________________________ 19 4.1 Methods of Arming and Disarming________________________________________ 4.2 24 Hours Arming______________________________________________________ 4.3 Selectable Zone Arming________________________________________________ 4.4Selectable Detector Alarming Local only or Local and C.S.____________________21 4.5Selectable Key Fob Requiring Assistance with/without sounder__________________ 4.6 Omitting a Zone_____________________________________________________21 4.7 Sounder or silent alarm setting__________________________________________ 4.8Access the Control Panel from a remote telephone (mobile or land line) _________ 21 4.9 Alarm confirming____________________________________________________ 22 4.10Detector Battery Low Voltage Display On the Panel And Introduction___________22 5 ZONE CONFIGURATION AND EXPLANATION____________________________ 23 3 3 1. OVERVIEW 1.1 Introduction This security system uses advanced technology and brings together reliable, yet simple products that offer state-of-the-art security options. These options enable you to customize many of the advanced features through a straightforward keypad interface. Simple menu-driven commands eliminate the need for user manuals thus reducing training time to a minimum. Our system was developed in collaboration with end users resulting in a keypad that is intuitive and that guides the user through every procedure. All of the actions performed in your security system will be executed and displayed through the keypad. We recommend that you read this manual thoroughly and have your installer explain basic system operation to you. Functions: 1. Blue backup LCD display everything you want to know about the panel. 2. 85 event log about arming, disarming, and alarming (with time and date stamp), viewable directly on the panel LCD 3. 12 seconds voice message, in case of alarming, automatically playing after you pick up your phone . 4. Any of the detector can be door bell when disarmed; any detector can be local siren when disarmed 5. Monitor the old, the sick and the important place: when the old doesn’t move, or the important warehouse hasn’t human presence for a period of time, the panel will alarm. 6. Any zone type programmable (including: watchdog zone, exit/entry delay, 24 hours zone, sounder/silent when alarming, armed/part armed zone, sensor/no sensor in the zone) 7. Panel can receive the detector low voltage signal and display zone number and detector number on the LCD and sound a beep 8. 7 wired terminals and 50pcs detectors in all 10. 6 time points of timed Auto-Arming/disarming (24 hour mode) 11. Wireless detector installing test 12.Listen in and speak funtion 13. Away arming with sounder ON 14. Built-in high capacity rechargeable battery, auto charge/discharge, provide backup when main fails. 1.2 Basic Principle of Operation 4 4 Fig 1. Basic principle of operating The above chart shows the basic principle of operation of the system. The security system contains alarm panel, remote Key Fob’s, PIR detectors, Door/Window magnetic contact and high decibel integral siren. Also available are some optional devices such as wired/wireless Smoke detectors, Gas detector, Flood detector, Temperature detector. The wireless detector communicates to the Control Panel by radio on 433 MHz frequency and each detector has an approximate range of 50 metres dependent on the local enviroment. The wired detector are also workable. 1.3 Component Parts The wired/Wireless Alarm panel: This 8 Zone Alarm panel is the central information processor of the system, receiving and dealing with all the alarm signals from the various detectors. It also contains the Central Station communicator and By-directional Audio Verification mechanisum. Everything you need to know about the security system is displayed on the panel keypad LCD. The zones, 24 hour, Armed, Part Armed, Disarmed and the important messages regarding system status are displayed on the LCD scr…
Text truncated - open the document above for the full version.
External Photo for model: SV-GSM04, SV-ST-III, SV-FC-300, SV-3GA02, SV-THA5700, SV-MMS02, SV-3GA01, SV-MMS01, SV-GSM5100, SV-MMS05 External Photo for model: SV-GSM04, SV-ST-III, SV-FC-300, SV-3GA02, SV-THA5700, SV-MMS02, SV-3GA01, SV-MMS01, SV-GSM5100, SV-MMS05 External Photo for model: SV-GSM04, SV-ST-III, SV-FC-300, SV-3GA02, SV-THA5700, SV-MMS02, SV-3GA01, SV-MMS01, SV-GSM5100, SV-MMS05 External Photo for Adapter
FCC ID LABEL FCC ID:Y7CSV-GSM04 This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:1. This device may not cause harmful interference, and 2. This device must accept any interference received,including interference that may cause undesired operation. Label Location on EUT EUT Bottom View/ FCC ID Label Location
Internal Photo for model: SV-GSM04, SV-ST-III, SV-FC-300, SV-3GA02, SV-THA5700, SV-MMS02, SV-3GA01, SV-MMS01, SV-GSM5100, SV-MMS05 Internal Photo for model: SV-GSM04, SV-ST-III, SV-FC-300, SV-3GA02, SV-THA5700, SV-MMS02, SV-3GA01, SV-MMS01, SV-GSM5100, SV-MMS05 Antenna Internal Photo for model: SV-GSM04, SV-ST-III, SV-FC-300, SV-3GA02, SV-THA5700, SV-MMS02, SV-3GA01, SV-MMS01, SV-GSM5100, SV-MMS05
DESCRIPTION When receiving module received the alert signals,it will sent back to main chip(STC89C52RC), the main chip spot the alert signals and controls three part: 1. Starting the pronunciation alarm chip after amplifier alarm sound acoustics. 2. Control lamp boards display the path of alert. 3. Control dial-up circuit and dial-up the outside line. Perimeter layout/removal functions by 9170 IC identify and decoding, dial-up outside line will completion by 9200 IC code. when you want to recording, you must open the S1 switch to the recording key, then click recording again.
FCC PART 15 CLASS B EMI MEASUREMENT AND TEST REPORT For Supremevalue International Co.,Ltd 2F, YanFa Building, HongFa Hi-Tech Park, Tangtou Road, Shiyan Town, Bao'an District, Shenzhen, China FCC ID:Y7CSV-GSM04 Jan. 25, 2011 This Report Concerns: Original Report Equipment Type Alarm System Test Engineer: Eric Li Report No.: BST10110218R-3 Receive EUT Date/Test Date: Jan.18,2011/ Jan.18-25,2011 Reviewed By: Christina Deng Prepared By: Shenzhen BST Technology Co.,Ltd. 3F,Weames Technology Building, No. 10 Kefa Road,Science Park, Nanshan District,Shenzhen,Guangdong,China Tel: 0755-267477513 Fax: 0755-267477513 ext.826 Note: The test report is specially limited to the above company and this particular sample only. It may not be duplicated without prior written consent of Shenzhen BST Technology Co.,Ltd. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP, NIST or any agency of the US Government. Supremevalue International Co.,Ltd FCC ID: Y7CSV-GSM04 BST FCC ID REPORT : BST10110218R-3 Page 2/17 TABLE OF CONTENTS 1. GENERAL INFORMATION .................................................................................................... 3 1.1. Report information............................................................................................................ 3 1.2. Measurement Uncertainty................................................................................................. 3 2. PRODUCT DESCRIPTION ...................................................................................................... 4 2.1. EUT Description ............................................................................................................... 4 2.2. Block Diagram of EUT Configuration ............................................................................. 4 2.3. Support Equipment List .................................................................................................... 4 2.4. Test Conditions .................................................................................................................4 3. FCC ID LABEL........................................................................................................................... 5 4. TEST RESULTS SUMMARY ................................................................................................... 6 Modifications ................................................................................................................................ 6 5. TEST EQUIPMENT USED ....................................................................................................... 7 5.1. For Conducted Emission Test ........................................................................................... 7 5.2. For Radiated Emission Measurement ............................................................................... 7 6. CONDUCTED EMISSION TEST............................................................................................. 8 6.1. Block Diagram of Test Setup............................................................................................ 8 6.2. Test Standard .................................................................................................................... 8 6.3. Conducted Emission Limit(Class B) ................................................................................ 8 6.4. EUT Configuration on Test .............................................................................................. 8 6.5. Operating Condition of EUT ............................................................................................ 8 6.6. Test Procedure ..................................................................................................................9 6.7. Test Result ........................................................................................................................ 9 7. RADIATED EMISSION MEASUREMENT ......................................................................... 10 7.1. Block Diagram of EUT Configuration ........................................................................... 10 7.2. Test Standard ..................................................................................................................10 7.3. Radiated Emission Limit(Class B) ................................................................................. 10 7.4. EUT Configuration on Test ............................................................................................ 11 7.5. Operating Condition of EUT .......................................................................................... 11 7.6. Test Procedure ................................................................................................................ 11 7.7. Test Result ...................................................................................................................... 11 APPENDIX I ......................................................................................................................................... 12 APPENDIX II........................................................................................................................................ 16 Supremevalue International Co.,Ltd FCC ID: Y7CSV-GSM04 BST FCC ID REPORT : BST10110218R-3 Page 3/17 1. GENERAL INFORMATION 1.1. Report information 1.1.1.This report is not a certificate of quality; it only applies to the sample of the specific product/equipment given at the time of its testing. The results are not used to indicate or imply that they are application to the similar items. In addition, such results must not be used to indicate or imply that BST approves recommends or endorses the manufacture, supplier or use of such product/equipment, or that BST in any way guarantees the later performance of the product/equipment. 1.1.2.The sample/s mentioned in this report is/are supplied by Applicant, BST therefore assumes no …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 433.92 MHz - 433.92 MHz | - |