FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Venture Global Limited/
  3. YAHHAXPFAT

YAHHAXPFATMulti-Functional Alarm Transmitter

Venture Global Limited
Multi-Functional Alarm Transmitter - FCC ID YAHHAXPFAT - Venture Global Limited
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jul 13, 2015
Application Purpose
Original Equipment
Date of Application
Jul 13, 2015
Equipment Note
Multi-Functional Alarm Transmitter
Frequency Range
914.80000000 - 914.80000000
Company
Venture Global Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: Modifications to this product will void the user's authority to operate this equipment. R Mode Mat Pad +3S II I R Mode Mat Pad +3S II I R Mode Mat Pad +3S II I USER MANUAL HAX-300-500 PWR TX SND LIGHT On Off On Off ReCode A On Off B Mode Sound Hi Lo Off NO NC 3S Parts and Function 1 2 10 11 13 14 15 16 12 17 18 3 4 5 6 7 8 9 1. Batteries compartment 2. Battery Door 3. Regenerates new code button. 4. Power on/off switch 5. Transmitter On/off switch. 6. Alert sound selector. Power + Remove the screw and slide to open the battery cover Flip to open the coverInsert 3 AAA bateries to the battery compartment and close the battery cover A AA A A A AAA Setting 7. Light on/off switch. 8. Volume control. 9. Mode control. 10. Sensor input jack 11. Anti-take off Cover 12 Cover lock Installation Nurse Call Button Chair Pad Chair Pad plug Unlock lock Unlock and slide out the cover to install the plug Slide the switches inside the battery cover for your needs. 1. Power Switch to off position when do not use this device. 2. Transmitter On/Off switch On : Send a trigger signal to receiver when triggered Off : Do not send signal to receiver when triggered. 3. Sound selector Select the suitable sound by slide this switch to or position.. 4. Light On/Off Turn the flash light on or off by slide this switch. 5. Mode Mat (Fall mat): This mode for fall mat or entry mat. The unit triggered when someone step on the mat. Pad (Bed Pad): This mode for seat pad or bed pad. The unit triggered when Patients or elderly leave the pad. Pad +3S (Pad & 3 seconds delay): Same as Pad mode but delay 3 seconds for reduce False alarms. 6. Volume control You can select High II / Low I / No sound by slide this switch. 7 Regenerate a new code If the RF code is conflict, press the button in the pin hole to regenerate a new code 13 Flasher 14. Speaker 15 LED indicator. 16. Test /Reset button 17. External DC jack 18. Nurse call button jack. 1 2 3 4 5 6 7 EXIT Pairing with receiver Operation This unit can work stand alone or work with the wireless receiver. If work with the receiver, you need to pairing with the receiver follow to the manual of the receiver. Velcro Mat mode The sensor unit will be triggered when someone step on the mat. Pad mode when the person lying (sitting) on the sensor pad. The sensor unit will generate a beep tone to confirm the pad is function. The unit will be triggered when Patients or elderly leave the pad sensor. Alarm will stop when the person return to the pad or press the stop button. Delay Mode Functions are same as Pad mode, but delay 3 seconds after triggered for reduce False alarms. Nurse call Press the nurse button once (the big nurse call button must be plug in), the sensor unit will be send a trigger signal to receiver, and sensor unit will generate beep tone to indicate this button is pressed. R R R Mode Mat Pad +3S II I Test & Reset - Test: Press the test/Reset button once, The unit will generate a beep tone, LED will blink and will send a RF to the receiver (It will depend on the function switch setting) - Reset: When the alarm is triggered, press the test/Reset thrice within 2 seconds will stop Or Using a 5V/ 300mA AC/DC adaptor 5V AC/DC adaptor (Switching mode)

External Photos

FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 1 of 3 1. External Photos of the EUT External view -1 External view-2 External view- 3 FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 2 of 3 External view-4 External view-5 External view-6 FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 3 of 3 External view-7 External view-8

ID Label/Location Info

FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 1 of 1 LABEL PHOTOGRAPHS LABEL LOCATION

Internal Photos

FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 1 of 3 1. External Photos of the EUT Internal view PCB 1 side1 FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 2 of 3 PCB 1 side 2 PCB 2 side 1 FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 3 of 3 PCB 2 side 2 Oscillator view

Test Report

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC ID TEST REPORT TEST REPORT NUMBER : CGZ3150617-00685-EF CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 1 of 21 TEST REPORT For FCC ID 47 CFR PART 15 OCT, 2014 Report Reference No. ...........CGZ3150617-00685-EF Date of issue............................29 June 2015 Testing Laboratory Name .....CENTRE OF TESTING SERVICE CO., LTD. Address.................................... A101, No.65, Zhuji Highway,Tianhe District, Guangzhou, China Testing location/ procedure ..... Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s name ...................Venture Global Limited Address....................................Room 1102,11/F.,Fabrico Industrial Building,78-84 Kwai Cheong Road,Kwai Chung,N.T., HongKong Test specification .................. Standard .................................. 47 CFR PART 15 OCT, 2014 Test Report Form No. ...........CTSEMC-1.0 TRF Originator .........................CENTRE OF TESTING SERVICE CO., LTD Master TRF..............................Dated 2009-01 CENTRE OF TESTING SERVICE CO., LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the CENTRE OF TESTING SERVICE CO., LTD is acknowledged as copyright owner and source of the material. CENTRE OF TESTING SERVICE CO., LTD takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ............Multi-functional Alarm Transmitter Trade Mark ..............................GUARDMAN Manufacturer............................Venture Global Limited Model/Type reference..............HAX-300-500 Ratings.....................................Battery 1.5V*3 Operating Frequency ...............914.8 MHz Result ...................................... Positive Compiled by: Supervised by: Approved by: Kate zhang / File administrators Duke yang / Technique principal Vincent yao / Manager FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 2 of 21 FCC ID -- T E S T R E P O R T Test Report No. : CGZ3150617-00685-EF 29 June 2015 Date of issue Type / Model....................... HAX-300-500 EUT..................................... Multi-functional Alarm Transmitter Applicant....................... Venture Global Limited Address............................... Room 1102,11/F.,Fabrico Industrial Building,78-84 Kwai Cheong Road,Kwai Chung,N.T., HongKong Telephone............................ +852-3529 1206 Fax....................................... +852-3692 5980 Contact................................ CHOW.HING SANG ADAM Manufacturer.................. Venture Global Limited Address............................... Room 1102,11/F.,Fabrico Industrial Building,78-84 Kwai Cheong Road,Kwai Chung,N.T., HongKong Telephone........................... +852-3529 1206 Fax....................................... +852-3692 5980 Contact................................ CHOW.HING SANG ADAM Factory.......................... / Address............................... / Telephone............................ / Fax....................................... / Contact................................ / Test Result according to the standards on page 1: PASSED The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 3 of 21 TABLE OF CONTENTS Description Page 1.TEST STANDARDS.................................................................................................................................4 2.SUMMARY...............................................................................................................................................4 2.1 GENERAL REMARKS................................................................................................................................4 2.2 FINAL ASSESSMENT ................................................................................................................................4 3.EQUIPMENT UNDER TEST....................................................................................................................4 3.1 POWER SUPPLY SYSTEM UTILISED..................................................................................................................4 3.2 SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT) ................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 1 of 2 1 Photos of Radiated Emission Test (In Anechoic Chamber) Below 30MHz Below 1GHz Above 1GHz FCC ID:YAHHAXPFAT Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3150617-00685-EF Page 2 of 2 2 Photos of Band Edge Test (In Anechoic Chamber)

Contact Information

Applicant

CHOW,HING SANG ADAM / /(DIRECTOR)
[email protected]+852-3529 1206Fax: +852-3692 5980

Technical Contact

Centre of Testing Service Co., LtdVincent Yao
[email protected](86)2022138571

A101, No. 65, Zhuji Highway · Guangzhou, Guangdong · China

Test Firm

Centre of Testing service Co., LtdVincent Yao
[email protected]86-20-22138530Fax: 86-20-38780406

Technical Specifications

#Rule PartsFrequency RangePower Output
115C914.8 MHz - 914.8 MHz-
Confidentiality
Long Term

Other Applications from Venture Global Limited

Wireless Telephone Signaler - FCC ID YAHTFX-3TX - Venture Global Limited
YAHTFX-3TX

Wireless Telephone Signaler

Jun 27, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Temperature Humidity Sensor - FCC ID YAHTHX-100 - Venture Global Limited
YAHTHX-100

Wireless Temperature Humidity Sensor

Jun 27, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Indoor Motion Detector - FCC ID YAHHAX-900 - Venture Global Limited
YAHHAX-900

Wireless Indoor Motion Detector

Aug 27, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Magnetic Pull Alarm - FCC ID YAHHAX-700 - Venture Global Limited
YAHHAX-700

Wireless Magnetic Pull Alarm

Jul 15, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Signal Repeater - FCC ID YAHRPX1000 - Venture Global Limited
YAHRPX1000

Signal Repeater

Jun 09, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter