FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. AquaCheck (Pty) Ltd/
  3. YFF-ACROVER

YFF-ACROVEROEM Data logger module and transceiver for Aquacheck soil moisture probes

AquaCheck (Pty) Ltd
OEM Data logger module and transceiver for Aquacheck soil moisture probes - FCC ID YFF-ACROVER - AquaCheck (Pty) Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 15, 2014
Application Purpose
Original Equipment
Date of Application
Oct 13, 2014
Equipment Note
OEM Data logger module and transceiver for Aquacheck soil moisture probes
Frequency Range
902.50000000 - 918.75000000
Company
AquaCheck (Pty) Ltd
Country
South Africa

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

AquaCheck AC-ROVER User Guide for AquaCheck ROVER wireless OEM interface Module Version 2.01 12 Oct 2014 2 AquaCheck (Pty) Ltd All rights reserved Neither whole nor any part of the information contained in this publication may be reproduced, transcribed or translated in any form, written or electronic for any purpose whatsoever without prior written consent of AquaCheck (Pty) Ltd. This publication is intended only to assist the reader in the use of the product. AquaCheck (Pty) Ltd shall not be liable for any loss or damage arising from the use of any information contained in this publication, or any error or omission in such information, or any incorrect use of the product. “...then anyone who leaves behind him a written manual, and likewise anyone who receives it, in the belief that such writing will be clear and certain, must be exceedingly simple-minded...” Plato (423-347 BC). 3 STATEMENT OF COMPLIANCY ELECTRO-MAGNETIC COMPLIANCE The AquaCheck AC-ROVER has been tested and found to comply with the limits for this Class digital device, pursuant to the requirements of the CE rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to other radio communications. EMC APPROVALS The AquaCheck AC-ROVER has been tested and found to comply with the following EMC guidelines: EMISSIONS:  ETSI EN 300 220-2 V2.4.1  47 CFR 15C - RSS 210  47 CFR 15C – 15.247 (a)(2), (b)(3), (d), (e)  47 CFR 15C – 15.31(e)  47 CFR 15B – 15.109 (Class B)  AS/NZ 4268 (2012) IMMUNITY TESTING: ETSI EN 301 489-3 V1.4.1 / ESTI EN 302 489-1 V1.9.2  Radiated Immunity - EN 61000-4-2 4 Table of Contents CREDITS ...................................................................................................................................................... 5 OVERVIEW AND OPERATIONAL DESCRIPTION............................................................................. 5 LABELLING REQUIREMENTS............................................................................................................... 5 USERS MANUAL STATEMENT REQUIREMENTS............................................................................. 6 ANTENNA .................................................................................................................................................... 7 PHOTOS AND DRAWINGS OF THE ROVER MODULE .................................................................... 9 COMMUNICATIONS INTERFACE OPTIONS AND SETTINGS ....................................................... 9 COMMUNICATION INTERFACE ......................................................................................................... 11 SDI PROTOCOL......................................................................................................................................... 11 AQUACHECK DATA APPLICATION PROTOCOL.......................................................................................... 11 Data Command (or DATA H Conmmand).......................................................................................... 12 DELETE Command ............................................................................................................................ 14 DATE Command ................................................................................................................................. 14 PING Command.................................................................................................................................. 15 PROBE LIST Command...................................................................................................................... 15 ERASEEE Command .......................................................................................................................... 17 STATUS Command ............................................................................................................................. 17 LOG INT Command ............................................................................................................................ 17 CCTHR Command .............................................................................................................................. 18 CHANNEL Command ......................................................................................................................... 18 Digesting data..................................................................................................................................... 18 PRE INSTALLATION CONFIGURATION ........................................................................................... 19 INSTALLING THE ROVER MODULE IN A RS300 MODEM ........................................................... 19 USING THE ROVER MODULE WITH OTHER 3 RD PARTY EQUIPMENT ...................................21 FIRMWARE UPGRADE .......................................................................................................................... 22 SPECIFICATIONS .................................................................................................................................... 24 5 Credits AC-ROVER OEM module supports the Ranch Systems RSEXP command line protocol over SPI making it "plug and play" compatible with Ranch Systems telemetry and other OEM systems. The RSEXP protocol is referred to as “AquaCheck Data Application Protocol” in this document. For more information about Ranch Systems, the RSEXP protocol and their OEM telemetry programs, please visit www.ranchsystems.com Overview and operational description The AC-ROVER is a wireless interface that can establish a short range link to AquaCheck Wireless soil moisture probes. This is intended as a “cable replacement” option as well as a “node” or repeater that can service 10…

Text truncated - open the document above for the full version.

Cover Letter(s)

____________________________________________________________________________________________________________________________________ AquaCheck (Pty) Ltd, Reg. No. 2002/015316/07 Directors: J P Le Roux, A H Pickworth P O Box 2414, DURBANVILLE, 7551 Tel No: 021 970 5140 Office 1, 1 st Floor, 44 Oxford Fax No: 021 975 1254 CNR King & Oxford Streets, DURBANVILLE, 7550 www.aquacheck.co.za 8/11/2014 To Whom It May Concern: We hereby delegate CKC Certification Services, LLC (CKC CS) power of attorney to act on our behalf in matters pertaining to certification of products. The actions of CKC CS shall be considered the same as our own. Sincerely, Arthur Pickworth Technical Director AquaCheck (Pty) Ltd 1 st Floor; 44 Oxford Street; Durbaville; 77550; South Africa +27 21 970 5140

Cover Letter(s)

____________________________________________________________________________________________________________________________________ AquaCheck (Pty) Ltd, Reg. No. 2002/015316/07 Directors: J P Le Roux, A H Pickworth P O Box 2414, DURBANVILLE, 7551 Tel No: 021 970 5140 Office 1, 1 st Floor, 44 Oxford Fax No: 021 975 1254 CNR King & Oxford Streets, DURBANVILLE, 7550 www.aquacheck.co.za 8 August 2014 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for Permanent Confidentiality To whom it may concern: In accordance with 47CFR Section 0.457 and Section 0.459 pertaining to confidential material, we hereby request to hold permanently confidential all information contained within the below identified exhibits/document categories submitted pursuant to radio equipment certification requirements for FCC ID: YFF-ACROVER 1. Block Diagram 2. Schematics 3. Parts List The above material contains trade secrets and proprietary information as specified by 47CFR 0.457(d) and technical data, which would customarily be guarded from competitors. The public disclosure of this information might be harmful to our company and provide unjustified benefits to our competitors. Sincerely, Arthur Pickworth Technical Director AquaCheck (Pty) Ltd

Cover Letter(s)

AquaCheck (Pty) Ltd 44 oxford Rd, Durbanville, 7551 Rep of South Africa 10/8/2014 Federal Communications Commission Office of Engineering and Technology 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: This letter is to request Single Modular Approval in accordance with under FCC Rule Part 15.212(a)(1) for certification request under FCC ID: YFF ACROVER. This product an ISM node or data concentrator and can be used in OEM telemetry GSM or RF radio equipment. Declaration of conditions. Y/N 15.212(a)(1) Condition Y (i) The radio elements of the module have their own shielding. The physical crystal and tuning capacitors may be located external to the shielded radio elements Y (ii) The module has buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with part 15 requirements under conditions of excessive data rates or over- modulation. Y (iii) The module has its own power supply regulation. Y (iv) The module complies with the antenna and transmission system requirements of §§15.203, 15.204(b) and 15.204(c). The antenna(s) are either permanently attached or employ a “unique” antenna coupler (at all connections between the module and the antenna, including the cable). Y (v) The module was tested in a stand-alone configuration, i.e., the module was not inside another device during testing for compliance with part 15 requirements. Unless the transmitter module will be battery powered, it complies with the AC line conducted requirements found in §15.207. AC or DC power lines and data input/output lines connected to the module do not contain ferrites, unless they will be marketed with the module (see §15.27(a)). The length of these lines was the length typical of actual use or, if that length is unknown, at least 10 centimeters was used to insure that there is no coupling between the case of the module and supporting equipment. Any accessories, peripherals, or support equipment connected to the module during testing were unmodified and commercially available (see §15.31(i)). Y (vi) The module is equipped with either a permanently affixed label or is capable of electronically displaying its FCC identification number. Y (vii) The module complies with any specific rules or operating requirements that ordinarily apply to a complete transmitter and the applicant has provided adequate instructions along with the module to explain any such requirements. Y (viii) The module complies with any applicable RF exposure requirements in its final configuration. The instructions provided with the module adequately explain any usage conditions or restrictions. I acknowledge on behalf of the applicant that compliance of this module in all final configurations is the responsibility of the applicant under the condition that the integrator follows all provided installation instructions. Sincerely, Arthur Pickworth Technical Director, AquaCheck (Pty) Ltd.

ID Label/Location Info

AquaCheck AC-ROVER FCC ID: YFF-ACROVER IC: 8996A-ACROVER 15mm 10mm

RF Exposure Info

Page 1 of 8 Report No: 94327-31 RADIO FREQUENCY EXPOSURE REPORT FOR THE Device / Model: AC-ROVER Report No.: 94327-31 Date of issue: April 16, 2014 PREPARED FOR: AquaCheck (Pty) Ltd 1325 Hackberry St Bennet, NE 68317 PREPARED BY: Hieu Nguyenpham CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 The test data contained in this report documents the observed testing parameters pertaining to and are relevant for only the sample equipment tested in the agreed upon operational mode(s) and configuration(s) as identified herein. Compliance assessment remains the client’s responsibility. This report may not be used to claim product endorsement by A2LA or any government agencies. This test report has been authorized for release under quality control from CKC Laboratories, Inc. Steve Behm Director of Quality Assurance & Engineering Services CKC Laboratories, Inc. Page 2 of 8 Report No: 94327-31 Purpose: To demonstrate compliance with United States, Canada and/or European Union RF Exposure requirements for Portable equipment (devices used ≤20cm from the body) or Mobile equipment (devices used >20cm from the body) with power output below exemption levels and Mobile equipment, where Maximum Permissible Exposure (MPE) Calculations apply. United States Compliance Requirements (1.1310): RF Exposure Evaluation Limits Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3-3.0 614 1.63 *(100) 6 3.0-30 1842/f 4.89/f *(900/f 2 ) 6 30-300 61.4 0.163 1 6 300-1500 --- --- f/300 6 1500-100,000 --- --- 5.0 6 RF Exposure Evaluation Limits General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3-1.34 614 1.63 *(100) 30 1.34-30 824/f 2.19/f *(180/f 2 ) 30 30-300 27.5 0.073 0.2 30 300-1500 --- --- f/1500 30 1500-100,000 --- --- 1.0 30 * Plane wave equivalent power density Limit is calculated based on the mid-band frequency used in the operating frequency range. Exemption Level: Power output <60/f GHz (mW) Page 3 of 8 Report No: 94327-31 Canadian Compliance Requirements (RSS-102): RF Exposure Evaluation Limits Occupational / Controlled Exposure: Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (W/m 2 ) Averaging Time (minutes) 0.003-1.0 600 4.9 --- 6 1.0-10 600/f 4.9/f --- 6 10-30 60 4.9/f --- 6 30-300 60 0.163 10 6 300-1500 3.54 f 0.5 0.0094*f 0.5 f/3 6 1500-15,000 137 0.364 50 6 15,000-150,000 137 0.364 50 616000/f 1.2 RF Exposure Evaluation Limits General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (W/m 2 ) Averaging Time (minutes) 0.003-1.0 280 2.19 --- 6 1.0-10 280/f 2.19/f --- 6 10-30 28 2.19/f --- 6 30-300 28 0.073 2 6 300-1500 1.585 * f 0.5 0.0042 * f 0.5 f/150 6 1500-15,000 61.4 0.163 10 6 15,000-150,000 61.4 0.163 10 616000/f 1.2 *Power density limit applicable >100MHz Exemption Level: Frequency Range (MHz) Maximum Output Power (Conducted or EIRP) 0.003-1000 ≤ 200 mW 1000-2200 ≤ 100 mW 2200-3000 ≤ 20 mW 3000-6000 ≤ 10 mW Page 4 of 8 Report No: 94327-31 European Union Compliance Requirements (ICNIRP): RF Exposure Evaluation Limits Occupational / Controlled Exposure: Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (W/m 2 ) Averaging Time (minutes) 0.00082-0.065 610 24.4 --- 6 0.065-1.0 610 1.6/f --- 1.0-10 610/f 1.6/f --- 6 10-400 61 0.16 10 6 400-2000 3.0 * f 0.5 0.008 * f 0.5 f/40 6 2000-300,000 137 0.36 50 6 RF Exposure Evaluation Limits General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (W/m 2 ) Averaging Time (minutes) 0.003-0.150 87 5.0 --- 6 0.150-1.0 87 0.73/f -- 6 1.0-10 87/f 0.5 0.73/f --- 6 10-400 28 0.073 2 6 400-2000 1.375 f 0.5 0.0037*f 0.5 f/200 6 2000-300,000 61 0.16 10 6 *Power density limit applicable >100MHz Exemption Level: Power output < 20mW 1 Page 5 of 8 Report No: 94327-31 Device and Antenna Operating Configuration: Device operating at maximum output power with continuous transmission of modulated data. Device Operation The EUT is placed on a table. It is set continuously transmit Antenna Options: 900MHz Band Antenna with 5.25dBi GSM Wide Band Antenna with 2dBi Test Procedure: This equipment is evaluated in accordance with the guidelines set forth in OET Guide 65 & ANSI C95.1 for the US and Health Canada Safety Code 6 & RSS 102 for Canada. Other Considerations: None Page 6 of 8 Report No: 94327-31 MPE Calculations Applicability: Limit Used X General Population / Uncontrolled Exposure Occupational / Controlled Exposure RF Exposure Exemption Yes United States Yes Canada Yes Europe Equipment operational details: Config # Operating Frequency (MHz) Measured Output Power (dBm) Antenna Gain (dBi) Antenna Type / Configuration EIRP (dBm) 1 902-928 10.1 5.25 Omni 16.26 2 902-928 10.1 2 GSM Wide Band 12.1 Measurements based from EMC Test Report(s): 94327-10, 94327-11 and 94327-12 MPE Calculation: 2 4d EIRP DensityPower   Given: EIRP in mW or W and d in cm or m Config # Distance (cm) US (1.1310) Canada (RSS-102) EU (ICNIRP) Power Density (mW/cm 2 ) Limit (mW/cm 2 ) Power Density (W/m 2 ) Limit (W/m 2 ) Power Density (W/m 2 ) Limit (W/m 2 ) 1 2.85 Exempt -- Exempt -- Exempt -- 2 20 Exempt -- Exempt -- Exempt -- Page 7 of 8 Report No: 94327-31 Summary: Exemptions: In the case the equipment meets compliance requirements by exemption the product is approved for use under mobile or portable conditions without further testing under the condition that any additional collocation or simultaneous transmission requirements (including necessary separation distances) have been met. MPE Calculation Results: In the case the equipment meets compliance by MPE Calculations the product is approved for …

Text truncated - open the document above for the full version.

Test Report

This report contains a total of 74 pages and may be reproduced in full only. Partial reproduction may only be done with the written consent of CKC Laboratories, Inc. AquaCheck (Pty) LTD TEST REPORT FOR AC-ROVER Tested To The Following Standards: FCC Part 15 Subpart C, Section: 15.247 Report No.: 94327-10 Date of issue: April 16, 2014 This test report bears the accreditation symbol indicating that the testing performed herein meets the test and reporting requirements of ISO/IEC 17025 under the applicable scope of EMC testing for CKC Laboratories, Inc. We strive to create long-term, trust based relationships by providing sound, adaptive, customer first testing services. We embrace each of our customers’ unique EMC challenges, not as an interruption to set processes, but rather as the reason we are in business. Page 2 of 74 Report No.: 94327-10 TABLE OF CONTENTS Administrative Information ........................................................................................................................................... 3 Test Report Information ............................................................................................................................................ 3 Report Authorization ................................................................................................................................................. 3 Test Facility Information ............................................................................................................................................ 4 Software Versions ...................................................................................................................................................... 4 Site Registration & Accreditation Information .......................................................................................................... 4 Summary of Results ................................................................................................................................................... 5 Conditions During Testing.......................................................................................................................................... 5 Equipment Under Test ............................................................................................................................................... 6 Peripheral Devices ..................................................................................................................................................... 6 FCC Part 15 Subpart C .................................................................................................................................................... 7 15.247(b)(3) RF Power Output .................................................................................................................................. 7 15.31(e) Voltage Variations ..................................................................................................................................... 12 15.247(a)(2) Occupied Bandwidth ........................................................................................................................... 13 15.247(d) Antenna Conducted Emissions ................................................................................................................ 17 15.247(d) Field Strength of Spurious Emissions and Bandedge .............................................................................. 25 15. 247(e) Power Spectral Density .......................................................................................................................... 69 Supplemental Information .......................................................................................................................................... 73 Measurement Uncertainty ...................................................................................................................................... 73 Emissions Test Details .............................................................................................................................................. 73 Page 3 of 74 Report No.: 94327-10 ADMINISTRATIVE INFORMATION Test Report Information REPORT PREPARED FOR: REPORT PREPARED BY: AquaCheck (Pty) LTD 1325 Hackberry St. Bennet, NE 68317 Dianne Dudley CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 Representative: Brad Rathje Project Number: 94327 DATE OF EQUIPMENT RECEIPT: March 17, 2014 DATE(S) OF TESTING: March 17-April 4, 2014 Report Authorization The test data contained in this report documents the observed testing parameters pertaining to and are relevant for only the sample equipment tested in the agreed upon operational mode(s) and configuration(s) as identified herein. Compliance assessment remains the client’s responsibility. This report may not be used to claim product endorsement by A2LA or any government agencies. This test report has been authorized for release under quality control from CKC Laboratories, Inc. Steve Behm Director of Quality Assurance & Engineering Services CKC Laboratories, Inc. Page 4 of 74 Report No.: 94327-10 Test Facility Information Our laboratories are configured to effectively test a wide variety of product types. CKC utilizes first class test equipment, anechoic chambers, data acquisition and information services to create accurate, repeatable and affordable test results. TEST LOCATION(S): CKC Laboratories, Inc. 1120 Fulton Place Fremont, CA 94539 Software Versions CKC Laboratories Proprietary Software Version EMITest Emissions 5.00.14 Immunity 5.00.07 Site Registration & Accreditation Information Location CB # TAIWAN CANADA FCC JAPAN Fremont US0082 SL2-IN-E-1148R 3082B-1 958979 A-0149 Page 5 of 74 Report No.: 94327-10 SUMMARY OF RESULTS Standard / Specification: FCC Part 15 Subpart C Test Procedure/Method Description Results 15.247(b)(3) / DA 00-705 RF Power Output Pass 15.31(e) / DA 00-705 Voltage Variation …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Arthur Henry Pickworth(Mr)
[email protected]+27219705140Fax: +27(21)9751254

Test Firm

CKC Laboratories, Inc.Steve Behm
[email protected]209-966-5240Fax: 866 779 9776

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.5 MHz - 918.75 MHz10.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Power listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. Separate approvals may be required in multi-transmitter host configurations. Approved for use with antenna(s) as listed in this filing.

Other Applications from AquaCheck (Pty) Ltd

SOIL PROBE USED TO DETERMINE SOIL CHARACTERISTIC IN HORTICULTURAL AREAS - FCC ID YFF-ACPROBE-R - AquaCheck (Pty) Ltd
YFF-ACPROBE-R

SOIL PROBE USED TO DETERMINE SOIL CHARACTERISTIC IN HORTICULTURAL AREAS

Feb 09, 2015

Equipment Class

DTS - Digital Transmission System
AquaCheck RF-LOGGER - FCC ID YFF-ACCLOGGER - AquaCheck (Pty) Ltd
YFF-ACCLOGGER

AquaCheck RF-LOGGER

Sep 27, 2010

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
AquaCheck BASIC-II - FCC ID YFF-ACCPROBE - AquaCheck (Pty) Ltd
YFF-ACCPROBE

AquaCheck BASIC-II

Sep 27, 2010

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
AquaCheck SOLO LOGGER - FCC ID YFF-ACCSOLO - AquaCheck (Pty) Ltd
YFF-ACCSOLO

AquaCheck SOLO LOGGER

Sep 27, 2010

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified