FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GUANGDONG ROULE ELECTRONICS CO., LTD/
  3. YI6RL-0313B

YI6RL-0313BPIR MOTION LIGHT & Alarm

GUANGDONG ROULE ELECTRONICS CO., LTD
PIR MOTION LIGHT & Alarm - FCC ID YI6RL-0313B - GUANGDONG ROULE ELECTRONICS CO., LTD
Click to zoom

Application Details

Equipment Class
CRR - Superregenerative Receiver
Date of Grant
Dec 15, 2010
Application Purpose
Original Equipment
Date of Application
Dec 15, 2010
Equipment Note
PIR MOTION LIGHT & Alarm
Frequency Range
433.92000000 - 433.92000000
Company
GUANGDONG ROULE ELECTRONICS CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PIR Motion Light & Alarm User Manual 1. Open the back cover, Insert four pcs AA Battery, then close the back cover 2. Switch the switch on the offside to Alarm+Light or Light, then fix the device in the place where need guard against theft or need lighting. Note the height which is less than 1.8m and adjust it to the proper angle. 3. When it is in the status of guarding against theft: Switch the switch to Alarm+Light, press ON the remote control, you can hear one prompt tone, at this time, the device is in the garrison status, if someone enter into this zone after 60 seconds, the device will make alarm and shine the red light after 10 seconds; When it is in the status of lighting, it will be not controlled by the remote control, if the light is below the set value, someone enter into this zone, the device will emit bright light. 4. Press off the remote control, you can hear two prompt tone, the device will be in the status of removing the alarm. FCC ID: YI6RL-0313B IMPORTANT REGULATORY INFORMATION This device complies with Part 15 of the FCC Rules: Operation is subject to the following two conditions: 1. This device may not cause harmful interference and 2. This device must accept any interference that is received, including any interference that may cause undesired operation. WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipments.

Cover Letter(s)

Dec.13, 2010 Federal Communication Commission Authorization and Evaluation Division FCC ID: YI6RL-0313B Re: Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the applicant hereby requests confidential treatment of information applied this application as outlined below: 1: Block Diagram 2: Circuit Diagram 3: Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rules 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Signature________ ___________ FCC grantee contact person information. Name/Title: Huahao ZHANG (General Manager) Company Name: GUANGDONG ROULE ELECTRONICS CO.,LTD Address: No. 12, Pingdong 3rd Road, Nanping Industry, Community, Zhuhai Guangdong, China TEL: 086-0756-8818703 FAX: 086-0756-8818703

External Photos

PHOTOGRAPHS OF EUT TOP VIEW OF SAMPLE BOTTOM VIEW OF SAMPLE LEFT VIEW OF SAMPLE RIGHT VIEW OF SAMPLE FRONT VIEW OF SAMPLE BACK VEIW OF SAMPLE

ID Label/Location Info

FCC ID Label FCC ID: YI6RL-0313B This device complies with Part 15 of the FCC Rules: Operation is subject to the following two conditions: 1. This device may not cause harmful interference and 2. This device must accept any interference that is received, including any interference that may cause undesired operation. FCC ID Label Location

Internal Photos

INTERNAL PHOTO OF SAMPLE – 1 INTERNAL PHOTO OF SAMPLE – 2

Test Report

FCC Test Report Report No.: AGC11581012SZ02F1 FCC ID : YI6RL‐0313B PRODUCT DESIGNATION : PIR MOTION LIGHT & Alarm BRAND NAME : RL TEST MODEL : RL‐0313B CLIENT : GUANGDONG ROULE ELECTRONICS CO., LTD DATE OF ISSUE : Dec .10, 2010 STANDARD(S) : FCC Part 15 Rules Attestation of Global Compliance Co., Ltd. CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. Report No.: AGC11581012SZ02F1 Page 2of 25 TABLE OF CONTENTS 1. VERIFICATION OF COMPLIANCE ......................................................................................... 3 2. PRODUCT INFORMATION ..................................................................................................... 4 3. TEST FACILITY ....................................................................................................................... 5 4. SUPPORT EQUIPMENT LIST ................................................................................................. 6 5. SYSTEM DESCRIPTION ......................................................................................................... 6 6. FCC LINE CONDUCTED EMISSION TEST ........................................................................... 7 6.1. TEST EQUIPMENT OF LINE CONDUCTED EMISSION TEST .......................................... 7 6.2 .LIMITS OF LINE CONDUCTED EMISSION TEST ............................................................... 7 6.3. BLOCK DIAGRAM OF LINE CONDUCTED EMISSION TEST ............................................. 7 6.4. PROCEDURE OF LINE CONDUCTED EMISSION TEST .................................................... 8 6.5 TEST RESULT OF LINE CONDUCTED EMISSION TEST .................................................. 9 7. FCC RADIATED EMISSION TEST ........................................................................................ 10 7.1. TEST EQUIPMENT OF RADIATED EMISSION ................................................................. 10 7.2. LIMITS OF RADIATED EMISSION TEST ........................................................................... 10 7.3 BLOCK DIAGRAM OF RADIATED EMISSION TEST .......................................................... 10 7.4 PROCEDURE OF RADIATED EMISSION TEST ................................................................. 11 7.5 TEST RESULT OF RADIATED EMISSION TEST ............................................................... 13 APPENDIX 1 .............................................................................................................................. 20 PHOTOGRAPHS OF TEST SETUP .......................................................................................... 20 APPENDIX 2 .............................................................................................................................. 21 PHOTOGRAPHS OF EUT ......................................................................................................... 21 Report No.: AGC11581012SZ02F1 Page 3of 25 1. VERIFICATION OF COMPLIANCE Equipment Under Test: PIR MOTION LIGHT & Alarm Model Name: RL-0313B Model Difference: N/A Brand Name: RL Applicant: GUANGDONG ROULE ELECTRONICS CO., LTD No.12,Pingdong 3rd Road, Nanping Industry Community, Zhuhai City, GuangDong, China Manufacturer: GUANGDONG ROULE ELECTRONICS CO., LTD No.12,Pingdong 3rd Road, Nanping Industry Community, Zhuhai City, GuangDong, China Type of Test: FCC Class B Measurement Procedure: ANSI C63.4: 2003 File Number: AGC11581012SZ02F1 Date of test: Dec. 02, 2010 to Dec.10, 2010 Deviation: None Condition of Test Sample: Normal The above equipment was tested by Attestation Of Global Compliance Co., Ltd. For compliance with the requirements set forth in the FCC Rules and Regulations Part 15, the measurement procedure according to ANSI C63.4:2003 This said equipment in the configuration described in this report shows the maximum emission levels emanating from equipment are within the compliance requirements. The test results of this report relate only to the tested sample identified in this report. Checked By : Jekey Zhang Dec.10, 2010 Authorized By : King Zhang Dec.10, 2010 Report No.: AGC11581012SZ02F1 Page 4of 25 2. PRODUCT INFORMATION I/O Port Information ( Applicable Not Applicable) I/O Port of EUT I/O Port Type Q’TY Cable Tested with -- -- -- -- Equipment Under Test: PIR MOTION LIGHT & Alarm FCC ID YI6RL-0313B Housing Type: Plastic Rating Voltage: DC 6.0V(4*1.5V) by battery Receive frequency: 433.9MHz (only one channel) Description of EUT It is only Receive, and isn’t transmit Size of EUT: Length 11.8cm width 6.2cm height 4.3cm Report No.: AGC11581012SZ02F1 Page 5of 25 3. TEST FACILITY Location: 1F, No.2 Building, Huafeng No.1 Technical, Industrial Park, Sanwei, Xixiang, Baoan District, Shenzhen, China. Description: There is one 3m semi-anechoic chamber for final test, the Line Conducted labs are constructed and calibrated to meet the FCC requirements in documents ANSI C63.4 and CISPR 22/EN 55022 requirements. Site Filing: FCC register No.: 259865 Instrument Tolerance: All measuring equipment is in accord with ANSI C63.4 requirements that meet industry regulatory agency and accreditation agency requirement. Ground Plane: Two conductive reference ground planes were used during the Line Conducted Emission, one in vertical and the other in horizontal. The dimensions of these ground planes are as below. The vertical ground plane was placed distancing 40 cm to the rear of the wooden test table on where the EUT and the support equipment were placed during test. The horizontal ground plane projected 50 cm beyond the footprint of the EUT system and distanced 80 cm to the wooden test table. For radiated emission test, one horizontal conductive ground plane extended at least 1m beyond the periphery of the EUT and the largest measuring antenna, and covered the entire area between the EUT and the antenna. It has no holes or gaps having longitudinal dimensions larger than…

Text truncated - open the document above for the full version.

Test Setup Photos

PHOTOGRAPHS OF TEST SETUP FCC RADIATED EMISSION TEST SETUP

Contact Information

Applicant

Huahao Zhang(General Manager)
[email protected]086-0756-8818703Fax: 086-0756-8818703

Test Firm

Attestation of Global Compliance Shenzhen Co. Ltd.Forrest Lei
[email protected]86-755-29081966Fax: 86-755-26008484

Technical Specifications

#Rule PartsFrequency RangePower Output
115B433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from GUANGDONG ROULE ELECTRONICS CO., LTD

Wireless doorbell (transmitter) - FCC ID YI6-RL-38TX - GUANGDONG ROULE ELECTRONICS CO., LTD
YI6-RL-38TX

Wireless doorbell (transmitter)

Mar 13, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless doorbell (transmitter) - FCC ID YI6-RL22TX - GUANGDONG ROULE ELECTRONICS CO., LTD
YI6-RL22TX

Wireless doorbell (transmitter)

Mar 12, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless door magnetic doorbell - FCC ID YI6RL-9805TX - GUANGDONG ROULE ELECTRONICS CO., LTD
YI6RL-9805TX

Wireless door magnetic doorbell

Sep 02, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
YI6RL-9816C1

Car Warning Indicator

Jan 21, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
YI6RL-WD01

Wi-Fi Window/Door Sensor

Jan 16, 2024

Equipment Class

DTS - Digital Transmission System