DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Oct 04, 2010
Application Purpose
Original Equipment
Date of Application
Sep 30, 2010
Equipment Note
ReminderLight
Frequency Range
907.90000000 - 907.90000000
Company
Vitality, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

9am10am11am8am 7am This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures. ›I\fi`\ekfii\cfZXk\k_\i\Z\`m`e^Xek\eeX ›@eZi\Xj\k_\j\gXiXk`feY\kn\\ek_\\hl`gd\ekXe[i\Z\`m\i ›:fee\Zkk_\\hl`gd\ek`ekfXeflkc\kfeXZ`iZl`k[`]]\i\ek]ifdk_Xkkfn_`Z_k_\ receiver is connected ›:fejlckk_\[\Xc\ifiXe\og\i`\eZ\[iX[`f&KMk\Z_e`Z`Xe]fi_\cg The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmit- ter. 8epZ_Xe^\jfidf[`]`ZXk`fejefk\ogi\jjcpXggifm\[Ypk_\gXikpi\jgfej`Yc\]fiZfdgc`XeZ\Zflc[mf`[k_\ user’s authority to operate the equipment.

Cover Letter(s)

Vitality, Inc. One Broadway 14 th Floor Cambridge, MA 02142 http://www.vitality.net August 23, 2010 Nemko 11696 Sorrento Valley Rd. San Diego CA, 92121 USA Re: Request of Confidentiality for FCC ID#: YOC373200 Pursuant to Sections 0.457(d)(I)(ii) and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying as outlined below: Schematics, Parts List, Operating Description, Block Diagrams The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(I)(ii), disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this Application. Sincerely, Joshua Wachman President Vitality, Inc.

Cover Letter(s)

Vitality, Inc. One Broadway 14 th Floor Cambridge, MA 02142 http://www.vitality.net August 27, 2010 Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification FCC ID: YOC373200 Authority to Act as Agent On our behalf, I appoint Alan Laudani of Nemko USA Inc., 11696 Sorrento Valley Rd, San Diego, CA, USA to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in Federal Communication Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides with Joshua Wachman, Vitality, Inc. 1 Broadway 14 th Floor, Cambridge, MA 02142 USA, expiring 2/27/2011. Sincerely, Joshua Wachman President Vitality, Inc.

ID Label/Location Info

Vitality ™ www.vitality.net 1-866-389-8686 Designed in Cambridge by Vitality Made in China. Patents pending. Indoor, Dry location use only Model: Reminder Light 120V125mA 60Hz FCC ID: YOC373200 CONTAINS FCC ID: RI7GE864 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

ID Label/Location Info

Vitality ™ www.vitality.net 1-866-389-8686 Designed in Cambridge by Vitality Made in China. Patents pending. Indoor, Dry location use only Model: Reminder Light 120V125mA 60Hz FCC ID: YOC373200 CONTAINS FCC ID: RI7GE864 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. RL Pad Printing Presentation, 2010/08/31 To be pad printed on back side of Reminder Light. PMS 428C 10.100 mm 11.100 mm 21.000 mm

Internal Photos

120 VAC power supply

RF Exposure Info

S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to isotropic R = distance to the center of radiation of the antenna S=GP/(4PiR^2) 800 MHz Cell15.249 output power34.40(dBm)EIRP-9.33(dBm)EIRP output power2754(mW)0.12(mW) antenna gain0(dBi)0(dBi) antenna gain1.000(numeric)1.000(numeric) distance20(cm)20(cm) duty cycle25(%)5.6(%) frequency824.2(MHz)907.9(MHz) MPE limit0.549(mW/cm^2)0.605(mW/cm^2) power density0.137(mW/cm^2)0.00000130(mW/cm^2) margin6.0(dB)56.7(dB) combined0.25<1

Test Report

Nemko USA, Inc. 11696 Sorrento Valley Rd., Suite F San Diego, CA 92121-1024 Phone (858) 755-5525 Fax (858) 452-1810 CERTIFICATION TEST REPORT In Accordance With: FCC Part 15 Subpart C, 15.249 IC RSS-210 Issue 7 June 2007 Applicant: Vitality, Inc. 1 Broadway 14th Floor Cambridge, MA 02142 Equipment Under Test : Reminder Light Transceiver Model: Reminder Light FCC ID: YOC373200 Tested By: Nemko USA Inc. 11696 Sorrento Valley Road, Suite F San Diego, CA 92121 Test Report: 2010 081515031 FCC Date: August 10, 2010 Project number: 47887-1 Nex Number: 151031 Total Number of Pages: 23 Nemko USA, Inc. 11696 Sorrento Valley Road, Suite F, San Diego, CA 92121 Phone (858) 755-5525 Fax (858) 452-1810 Report Number: 2010 081515031 FCC FCC ID: YOC373200 Specification: FCC Part 15 Subpart C, 15.249 Section 1. Summary of Test Results General All measurements are traceable to national standards These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 15; Subpart C. Radiated tests were conducted is accordance with ANSI C63.4-2003. Radiated emissions are made on an open area test site. A description of the test facility is on file with the FCC. The assessment summary is as follows: Apparatus Assessed: Reminder Light Transceiver Model: Reminder Light Specification: FCC Part 15 Subpart C, 15.249 IC RSS-210 Issue 7 June 2007 Date Received in Laboratory: August 5, 2010 Compliance Status: Complies Exclusions: None Non-compliances: None Nemko USA, Inc. 11696 Sorrento Valley Road, Suite F, San Diego, CA 92121 Phone (858) 755-5525 Fax (858) 452-1810 Report Number: 2010 081515031 FCC FCC ID: YOC373200 Specification: FCC Part 15 Subpart C, 15.249 Report Release History REVISION DATE COMMENTS - August 10, 2010 Prepared By: Alan Laudani - August 10, 2010 Initial Release: Alan Laudani Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. Nemko USA Inc. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko USA Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. TESTED BY: __ Date: August 10, 2010 Alan Laudani, EMC Test Engineer Nemko USA, Inc. 11696 Sorrento Valley Road, Suite F, San Diego, CA 92121 Phone (858) 755-5525 Fax (858) 452-1810 Report Number: 2010 081515031 FCC FCC ID: YOC373200 Specification: FCC Part 15 Subpart C, 15.249 TABLE OF CONTENTS Section 1. Summary of Test Results.......................................................................... 2 Report Release History ................................................................................................................................. 3 Section 2: Equipment Under Test ................................................................................... 5 2.1 Product Identification........................................................................................................................ 5 2.2 Samples Submitted for Assessment ................................................................................................5 2.3 Theory of Operation ......................................................................................................................... 6 2.4 Technical Specifications of the EUT ................................................................................................ 6 Section 3: Test Conditions .............................................................................................. 7 3.1 Specifications ................................................................................................................................... 7 3.2 Deviations From Laboratory Test Procedures ................................................................................. 7 3.3 Test Environment ............................................................................................................................. 7 3.4 Test Equipment ................................................................................................................................ 8 Section 4: Observations .................................................................................................. 9 4.1 Modifications Performed During Assessment .................................................................................. 9 4.2 Record Of Technical Judgements.................................................................................................... 9 4.3 EUT Parameters Affecting Compliance ........................................................................................... 9 4.4 Tests Deleted ................................................................................................................................... 9 4.5 Additional Observations ................................................................................................................... 9 Section 5: Results Summary ......................................................................................... 10 5.1 Results Summary........................................................................................................................... 10 Appendix A: Test Results ..............................................................................................A1 Power line Conducted Emissions ...............................................................................................................A1 Occupied Bandwidth .......................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

David Liu(Principal Engineer)
[email protected]8583693316Fax: 8583693399

Technical Contact

Dragon Innovation, LLC.Scott Nielsen Miller
[email protected]781 290 8945

80 Marrett Road · Lexington · United States

Non-Technical Contact

Vitality, Inc.Julia Kim
[email protected]617 401 2238

Test Firm

Nemko USA, Inc. - San Diego EMC DivisionJan Blomgren
[email protected]760-444-3500

Technical Specifications

#Rule PartsFrequency RangePower Output
115C907.9 MHz - 907.9 MHz-
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Vitality, Inc.

GlowCap - FCC ID YOC373100 - Vitality, Inc.
YOC373100

GlowCap

Oct 07, 2010

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified