FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GUANGZHOU CITY SAIBEI HOUSEHOLD APPLIANCES CO., LTD./
  3. YOFCEPE2010

YOFCEPE2010Induction Cooking Range

GUANGZHOU CITY SAIBEI HOUSEHOLD APPLIANCES CO., LTD.
Induction Cooking Range - FCC ID YOFCEPE2010 - GUANGZHOU CITY SAIBEI HOUSEHOLD APPLIANCES CO., LTD.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Dec 08, 2010
Application Purpose
Original Equipment
Date of Application
Dec 05, 2010
Equipment Note
Induction Cooking Range
Frequency Range
0.02000000 - 0.05000000
Company
GUANGZHOU CITY SAIBEI HOUSEHOLD APPLIANCES CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Cookers CommercialInductionCooker Manual SeriesModel:A6‐18C‐G Commercialinductioncookersafetyandoperatinginstructions Dearusers: ThankyouforchoosingCEPECOOKERS commercialelectromagneticstove! Thecookersfor hotel, restaurant buffetandcookingheatinsulation surfacedesign,uniqueto100watts to1800wattsofpowerpertoneDantributedesignedtMeetthechefcookingthebasisoftheircrafttoget whatyouwantfireortemperature.When youusethisproduct,pleasefamiliarwiththefollowingoperatingand safetyinstructions.Pleasekeep theproduct'soriginalpackaging.Iftheproductneedsrepair,usetheoriginalpackagingtobesent packing.Pleasesavethefileforfutureuse. AboutProducts Model ProductDescription Voltage Frequency Power Plug A6‐18T‐S DesktopWesterncookers AC 120v 60HZ 1800W PVVZ‐3P A6‐18C‐G WesternsautéstoveDesktop AC 120v 60HZ 1800W PVVZ‐3P A6‐3500S Desktop Teppanyaki AC 120v 60HZ 3500W PVVZ‐3P A6‐3500TC Desktopconcavetwocookers AC 120v 60HZ 7000W PVVZ‐3P A6‐3000T Desktopthreeheatsoupkitchen AC 120v 60HZ 9000W PVVZ‐3P A6‐2000T4 Floorcabinetstylefourheatsoup AC 120v 60HZ 8000W PVVZ‐3P Warning This equipment, such as improper use of electric shock, fire or burn hazard. In order to reduce the risk of injury: Please only access and signage consistent with the standard voltage grounded electrical outlet. Please do not put an empty pot on the work of the induction cooker, Beware of the burn. Cooker can only work on flat work table surface. Turn off and unplug the plug, such as induction cooker cool before cleaning or moving. Please do not touch the cable cooker ceramic plate surface. Cooker consequences in the still hot off the power. Do not switch panel or the appearance of the cooker or spray liquid cleaning agent. Cooker when not in use unplug the power plug, Please cooker and the power cord away from open flames, electric heaters, or high temperatures Please do not use induction heating canned goods or sealed containers, to avoid explosion. Take care when exposed to high temperature cooking, Do not put vents in the induction of any article in public, or children if used near a stove, please touch on the electric furnace surveillance, If the appliance is damaged or any sign of normal, discontinue use immediately, do not place any objects on the induction cooker Exclusiverighttousepot For cookers must be flat on the cooking and the cooker with a special iron cookware and ingredients must be 12 cm above the bottom of the width of Stainless steel products: such as flat‐bottomed soup bucket, stainless steel, stainless steel insulation pot, iron or cast iron products, such as frying pan, iron pan Cookware can not be used: the width of the chassis does not meet the 12 cm surface: ceramic, glass, aluminum, bronze pots and pans: meaning any form of leg disc cookware Installing cookers This section cookers only work on a flat horizontal surface, can not be placed or embedded into the landlord for any use. Special Reminder: Make sure cooker and between any of the surrounding environment where at least 10 cm to ensure adequate ventilation around the appliance: insufficient ventilation can cause overheating, to ensure that a reminder be seriously, do not remove the rear stainless steel isolation plate induction cooker , Induction prior to installation rocked to confirm whether the company had abnormal sound, if not to use, without you can use Cookers electric plug into the lake will be matched with a grounded outlet, outlet should not be installed in the location of water or moisture, The induction cooker on a flat, level work surface preparation IMPORTANT: By using the standard voltage and the nameplate voltage may damage the product does not match Beforeusingthecookerssafetyreminder Studies show that the cooker will not interfere with pacemakers, but for safety reasons, we recommend use of cardiac pacemaker beggar who should and operation of the cooker 30 cm, the distance between Cooker surface is made of special glass materials, once the cracks, please report immediately stop using and unplug the power plug immediately, do not spoon, kitchen utensils, pot or other small items placed in the operation of the cooker surface, These items will be heated, this product has the function of small items not heated to prevent small items were individually placed in the product table is accidentally heated, however, if these small items in the electric cooker in the oven surface and special cooking together Induction starts to work, these small items will also be heated, Keep all bank cards, identity cards and the magnetic induction of information and goods and separated from the magnetic field induction cooker will destroy the data on the magnetic stripe information. 1 Usecookers Please cookers placed in the flat, horizontal surface, 2. Please nameplate on the power cord and a standard grounded power outlet voltage matches The induction cooker with food cooking on the stove in the center dedicated 3 When you press the power on / off button, power light and the display will be illuminated Lu, 2 4 When the special anti‐cookers cookers cookers on display in the display when the state will remain open longer, which means that the heating cookers. After the first boot the appliance work in the power of chess‐style, through the power on? After the shutdown and then boot off button, no reset will still remain off the power or temperature mode before 3 3. By pressing the power / Shu‐power mode button to select the degree and the temperature mode, power mode to select the power of size (1 to 100) means the power from a scale from (1% `100%), the temperature control mode you can select the temperature range Lu in the right side of the display window will indicate the two LED lights to choose Fahrenheit or Celsius, the knob clockwise will increase the power and temperature, the knob counterclockwise will decrease the power and temperature, 4 4. Press the button to activate the time function of time, when the first button press time, the number "1" …

Text truncated - open the document above for the full version.

External Photos

External photos Model A6-18C-G Model A6-18T-S

ID Label/Location Info

Label & Location Model: A6-18C-G Model: A6-18T-S

Internal Photos

Internal photos Model A6-18C-G Model A6-18T-S

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 Tel: +86 20 82155555 Fax: +86 20 82075059 Email: [email protected] FEDERAL COMMUNICATIONS COMMISSION Registration number: 282399 Report No.: GZEM100700113701 Page: 1 of 20 FCC ID: YOFCEPE2010 Authorized Signature: Stephen Guo Manager The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. All test results in this report can be traceable to National or International Standards. This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only 1 Cover Page TEST REPORT Application No.: GZEM1007001137HS Applicant: GUANGZHOU CITY SAIBEI HOUSEHOLD APPLIANCES CO., LTD. FCC ID: YOFCEPE2010 Equipment Under Test (EUT): EUT Name: Induction Cooking Range Item No.: A6-18C-G, A6-18T-S ♣ ♣ Please refer to section 3 of this report for more details. Standards: FCC PART 18:2009 Date of Receipt: 2010-07-26 Date of Test: 2010-07-27 to 2010-10-30 Date of Issue: 2010-11-17 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Report No.: GZEM100700113701 Page: 2 of 20 FCC ID: YOFCEPE2010 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 2 Version Revision Record Version Chapter Date Modifier Remark 00 2010-11-17 Original Authorized for issue by: 2010-07-27 to 2010-10-30 Tested By (Crystal Wang) /Project Engineer Date 2010-11-16 Prepared By (Millie Li) /Clerk Date 2010-11-17 Checked By (Strong Yao) /Reviewer Date SGS-CSTC Standards Technical Services Co., Ltd. Report No.: GZEM100700113701 Page: 3 of 20 FCC ID: YOFCEPE2010 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 3 Test Summary Electromagnetic Interference (EMI) Test Test Requirement Test Method Class / Severity Result Conducted Emission (9 kHz to 30 MHz) FCC PART 18: 2009 FCC OST/ MP-5:1986 18.307(a) PASS ** Radiated Emission (9 kHz to 30 MHz) FCC PART 18: 2009 FCC OST/ MP-5:1986 18.305(b) PASS ** Remark : EUT: In …

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup photos Conducted Emissions, 9 kHz to 30 MHz Test Setup Model A6-18C-G Model A6-18T-S Radiated Emissions, 9 kHz to 30 MHz Test Setup Model A6-18C-G Model A6-18T-S

Contact Information

Applicant

HuiBing Zhang(Chairman of the board)
[email protected]020-39922290Fax: 020-39922282

Technical Contact

SGS-CSTC Standards Technical ServicesLtdCrystal Wang
[email protected]862082155308

198 KEZHU Road, SCIENTECH Park Guangzhou · Guangzhou · China

Non-Technical Contact

SGS-CSTC Standards Technical ServicesLtdMillie Li
[email protected]862082155332

Test Firm

SGS-CSTC Standards Technical Services Co., LtdJerry Chan
[email protected]860-208215-5331Fax: 860-208207-5059

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.02 MHz - 0.05 MHz-
Confidentiality
Long Term