Instruction Manual for Remote Control - Model 1999 For Essick Humidifier Models EP9 500 / EP9R 500 1B72058 9/10 Printed in China In English; En Español, En Français 2 Note: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not in-stalled and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/ TV technician for help. Installing and Replacing the Batteries The Remote Control uses two “AAA” size batteries (1.5V DC). Follow these steps to install or replace the batteries: 1. Open the battery cover, below the stand. 2. Insert the batteries as indicated by the polarity symbols (+ and -) marked inside the battery compartment. 3. Replace the battery cover 3 1999 Remote Control FEATURES Turns EP9 500/EP9R 500 humidifier on and off. Remotely controls the fan speed and humidity settings on the Essick EP9 500/EP9R 500 whole house humidifier. Reads relative humidity and air temperature from across the room. Displays temperature in °Fahrenheit or °Celsius. DESCRIPTION The 1999 Remote Control is a self- contained unit that can control the operation of the EP9 500 / EP9R 500 humidifier. When utilized on its own, the 1999 can act as a hygrometer to measure indoor relative humidity. This unit is not recommended for outdoor use. The remote is effective within 20 feet of the humidifier. It does not have to be pointed at the unit when making changes to the setting. It has three buttons on the front and a two level LCD screen that displays: Fan speeds from F1 (low) to F9 (high). Humidity settings that increase/decrease in 5% increments (25%- 65%). 4 Temperature measuring range: (+14°F to +122 °F) ( -10 °C to +50°C) with 0.1°F/ °F resolution. Humidity measuring range: 10 - 99% with 1% resolution. BASIC DISPLAYS 5 GETTING STARTED 1. Unlike most other remote controls you may have used, the 1999 must be turned on to be used as a remote control to the humidifier. Likewise, when not in use, we recommend the remote be turned off to save the batteries. 2. Pressing the I/O button once will turn the remote and the humidifier ON and take command of the humidifier. 3. After the remote is turned on, the remote display will show - - as it calibrates. It will then display the air temperature (in °F) and the relative humidity (in %). 4. When the humidifier is under the command of the 1999 remote, the display on the humidifier will show EC for External Control. COMMAND ORDER NOTE: If the humidifier is already on when the remote is turned on, the remote will take command of the humidifier controls and revert to the last settings used on the remote control. If the humidifier controls are adjusted while it is under the Remote’s command, the humidifier will take precedence over the remote, and revert to the last settings used on the humidifier. 6 5. Pressing the I/O button a second time will change the temperature scale from Fahrenheit (°F) to Celsius (°C). SETTING DISPLAYS 7 ENTERING SETTINGS Settings are entered into the remote control just as they are on the humidifier itself. 1. Setting Humidity: Press the center (humidity) button to increase the humidity. The humidity setting will increase in 5% increments starting at 25%, progressing up to 65%*, then cycling back to 25%. The humidity setting displays on the lower segment of the screen. After the setting is entered and displayed momentarily, the screen will return to showing the relative humidity. 2. Setting Fan Speed: Press the right hand button to adjust the fan speed. Each push of the button increases the speed ranging from F1 to F9, and then cycles back to F1. The fan setting will display on the lower segment of the display until complete, and then revert back to relative humidity setting. NOTE: Periodically the remote performs a frequency check and will be unresponsive to input. Wait 5 seconds and try your input again. * At 65% setting the unit will operate continuously. 8 Humidifier Remote Control Warranty Policy – Effective: JULY 16, 2010: This product is warranted against defects in workmanship and materials for ninety (90) days from the date of consumer purchase. This warranty does not apply to damage from accident, misuse, alterations, unauthorized repairs, unauthorized use, mishandling, unreasonable use or abuse. Within the limitations of this warranty, purchaser with inoperative units should contact customer service @ 800-547-3888 for paperwork and instructions on the return of the unit for repair. A copy of the sales receipt is required before authorization to return a unit for repair can be approved. This warranty will be null & void if purchaser attempts to repair or replace any parts. SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS. 9 Manual de instrucciones para el Control Remoto – Modelo 1999 Para los humidificadores Essick Modelos EP9 500 / EP9R 500 1B72058 9/10 Impreso en China 10 Nota: Los cambios o modificaciones sin aprobar expresamente por la parte responsable d…
Text truncated - open the document above for the full version.
MCU Temperature sensor Humidity sensor KEY RF module Battery LCD DISPLAY Block Diagram MAIN_CLOCK 4MHz SUB_CLOCK 32.768KHz PDF created with FinePrint pdfFactory trial version http://www.fineprint.com
PROFESSIONAL MOTOR (SHENZHEN) CO.,LTD. Ref. No.: WT10083317-E-F-F Page 29 of 26 12 Photographs - Constructional Details 12.1 EUT-Front View for TX 12.2 EUT-Back View for TX
PROFESSIONAL MOTOR (SHENZHEN) CO.,LTD. Ref. No.: WT10083317-E-F-F FCC TEST REPORT Page 1 of 31 Applicant : PROFESSIONAL MOTOR (SHENZHEN) CO.,LTD. Address : A55,FUSHING NGAU INDUSTRIAL ESTATE,PING HU ,LONG GANG,SHENZHEN CHINA Equipment Under Test (EUT) : Product description : Remote Model No. : 1999 Operation Frequency : 433.92MHz Standards : FCC 15 Subpart C Paragraph 15.231 Date of Test : August 27,2010 Test Engineer : Reviewed By : PERPARED BY: Waltek Services (Shenzhen) Co., Ltd. 1/F, Fukangtai Building,West Baima Rd.,Songgang Street, Baoan District, Shenzhen 518105,China Tel: +86-755-27553488 Fax: +86-755-27553868 PROFESSIONAL MOTOR (SHENZHEN) CO.,LTD. Ref. No.: WT10083317-E-F-F 2 0 Contents Page 1 COVER PAGE..........................................................................................................................................................1 2 CONTENTS ..............................................................................................................................................................2 3 TEST SUMMARY....................................................................................................................................................4 4 GENERAL INFORMATION..................................................................................................................................5 4.1 CLIENT INFORMATION............................................................................................................................................5 4.2 GENERAL DESCRIPTION OF E.U.T...........................................................................................................................5 4.3 DETAILS OF E.U.T. .................................................................................................................................................5 4.4 DESCRIPTION OF SUPPORT UNITS...........................................................................................................................5 4.5 STANDARDS APPLICABLE FOR TESTING..................................................................................................................5 4.6 TEST FACILITY........................................................................................................................................................6 4.7 TEST LOCATION......................................................................................................................................................6 5 EQUIPMENT USED DURING TEST ...................................................................................................................7 6 CONDUCTED EMISSION TEST ........................................................................................................................10 6.1 TEST EQUIPMENT..................................................................................................................................................10 6.2 TEST PROCEDURE.................................................................................................................................................10 6.3 CONDUCTED TEST SETUP.....................................................................................................................................11 6.4 EUT OPERATING CONDITION...............................................................................................................................11 6.5 CONDUCTED EMISSION LIMITS.............................................................................................................................12 6.6 CONDUCTED EMISSION TEST DATA......................................................................................................................12 7 RADIATION EMISSION TEST...........................................................................................................................13 7.1 TEST EQUIPMENT..................................................................................................................................................13 7.2 MEASUREMENT UNCERTAINTY.............................................................................................................................13 7.3 TEST PROCEDURE.................................................................................................................................................13 7.4 RADIATED TEST SETUP.........................................................................................................................................14 7.5 SPECTRUM ANALYZER SETUP...............................................................................................................................14 7.6 CORRECTED AMPLITUDE & MARGIN CALCULATION............................................................................................15 7.7 SUMMARY OF TEST RESULTS................................................................................................................................15 7.8 EUT OPERATING CONDITION...............................................................................................................................16 7.9 RADIATED EMISSIONS LIMIT.................................................................................................................................16 7.10 RADIATED EMISSIONS TEST RESULT................................................................................................................17 7.10.1 Radiated Emission Test Data .....................................................................................................................17 8 ANTENNA REQUIREMENT...............................................................................................................................21 9 PERIODIC OPERATION .....................................................................................................................................22 10 BANDWIDTH..........................................…
Text truncated - open the document above for the full version.
PROFESSIONAL MOTOR (SHENZHEN) CO.,LTD. Ref. No.: WT10083317-E-F-F Page 28 of 26 11 Photographs of Testing 11.1 Radiation Emission Test View For 30MHz-1000MHz 11.2 Radiation Emission Test View For 1GHz-5GHz
A55, Fushing Ngau Industrial Estate · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |