YZZGWN7604Mid-Tier AX3000 Wi-Fi 6 Access Point

Grandstream Networks, Inc.

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Sep 01, 2024
Application Purpose
Original Equipment
Date of Application
Aug 29, 2024
Equipment Note
Mid-Tier AX3000 Wi-Fi 6 Access Point
Frequency Range
5815.00000000 - 5815.00000000
Company
Grandstream Networks, Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗
↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Grandstream Networks, Inc. 126 Brookline Ave., 3rd Floor Boston, MA 02215, USA Tel: 1-617-5669300 Email: [email protected] CFR 47 §2.911(d)(5)(i) Attestation Letter Attestation Letter Date: 2024-08-22 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID: YZZGWN7604 Grandstream Networks, Inc. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature Junwei wang Contact Person: Junwei Wang Title: VP of HW Engineering

Attestation Statements

Grandstream Networks, Inc. 126 Brookline Ave., 3rd Floor Boston, MA 02215, USA Tel: 1-617-5669300 Email: [email protected] CFR 47 §2.911 (d)(5)(ii) Attestation Letter Attestation Letter Date: 2024-08-22 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: YZZGWN7604 Grandstream Networks, Inc. certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature Junwei wang Contact Person: Junwei Wang Title: VP of HW Engineering

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2024-08-22 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: YZZGWN7604 Grandstream Networks, Inc. certifies that, as of the date of the filing of the application, Grandstream Networks, Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. Grandstream Networks, Inc. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Grandstream Networks, Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent and Applicant Information: Name: Grandstream Networks, Inc. Address: 126 Brookline Ave., 3rd Floor Boston, MA 02215, USA FRN: 0020352431 Tel.: 1-617-5669300 Email: [email protected] Signed by (printed name): Junwei Wang Signature: Junwei wang

Cover Letter(s)

Grandstream Networks, Inc. 126 Brookline Ave., 3rd Floor Boston, MA 02215, USA Tel: 1-617-5669300 Email: [email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2024-08-22 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We Grandstream Networks, Inc., the undersigned, hereby authorizes Bay Area Compliance Laboratories Corp. (Shenzhen) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. (Shenzhen) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Junwei wang Junwei Wang VP of HW Engineering

Cover Letter(s)

Grandstream Networks, Inc. 126 Brookline Ave., 3rd Floor Boston, MA 02215, USA Tel: 1-617-5669300 Email: [email protected] FCC Confidential Authorization Date: 2024-08-22 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: YZZGWN7604 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Grandstream Networks, Inc. hereby requests long-term confidential treatment of information accompanying this application as outlined below:  Block Diagram  Schematics  Operation Description  Software Security Description As well as short-term confidential treatment of information accompanying this application for a period of 180 days after grant is issued as outlined below:  Internal Photos  User’s Manual  External Photos  Test Set-up Photos The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Junwei wang Junwei Wang VP of HW Engineering

ID Label/Location Info

Model: GWN7604 Input: 12V 2A This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-003(B) / NMB-003(B) IC: 11964A-GWN7604 FCC ID: YZZGWN7604 Made in China R1.0 48.00 mm 27.00 mm 5

ID Label/Location Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401U28582E-RF EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 17 of 628 Version 3.0 FCC §1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) Applicable Standard According to subpart §1.1310, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1500 / / f/1500 30 1500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. Result Calculation formula: Prediction of power density at the distance of the applicable MPE limit S = PG/4πR² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); For simultaneously transmit system, the calculated power density should comply with: Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 18 of 628 Version 3.0 Calculated Data: For worst case: Mode Frequency (MHz) Antenna Gain # Max Tune-up Power # Evaluation Distance (cm) Power Density (mW/cm 2 ) MPE Limit (mW/cm 2 ) (dBi) (numeric)(dBm)(mW) 2.4G Wi-Fi 2412-2462 6.97 4.98 29.0 794.3328 0.402 1.0 5.2G Wi-Fi 5180-5240 9.61 9.14 26.0 398.1128 0.370 1.0 5.3G Wi-Fi 5260-5320 9.61 9.14 22.0 158.4928 0.147 1.0 5.6G Wi-Fi 5500-5700 9.61 9.14 22.0 158.4928 0.147 1.0 5.8G Wi-Fi 5745-5825 9.61 9.14 25.0 316.2328 0.294 1.0 5.9G Wi-Fi 5845-5885 9.61 9.14 24.0 251.1928 0.233 1.0 Note: 1) The tune up conducted power and antenna gain was declared by the applicant. 2) For the Wi-Fi mode, the antenna gain would be the directional gain. 3) The 2.4G Wi-Fi and 5G Wi-Fi can transmit simultaneously. The ratio= MPE 2.4G Wi-Fi/limit+MPE5G Wi-Fi/limit =0.402/1.0+0.370/1.0=0.772<1.0, simultaneous exposure is not required. To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 28cm from nearby persons. Result: Compliant

Test Report

1 / 3 GWN7604-ANT0 Antenna Specification Brand Name: GRANDSTREAM Manufacture: SHENZHEN CHAOLIU NETWORK TECHNOLOGIES CO., LTD Manufacturing address:14th Floor, Building-C, Coolpad Building, Gaoxin North District, Science Park, Nanshan District, Shenzhen Product Number(or model Nanme): 118-00164-00 设计规格 specifications 频率范围 Frequency(MHz) 2.4G:2400~2500 5G:5150~5895 电压驻波比 VSWR ≦2.0:1 峰值增益 Peak Gain(dBi) 2.4G: 3.61 5G: 4.55 效率 Efficiency(%) ≧65 天线类型 Type Dipole Antenna 辐射方向 Radiation Properties 全向 Omni-directional 最大输入功率 Max Input Power(Watts) 2 极化方式 Polarization 垂直 Vertical 阻抗 Impedance(Ohms) 50 工作温度 Operation Temperature-40°C to 85°C 储存温度 Storage Temperature -40°C to 85°C 相对湿度 Relative Humidity 40% to 95% 环保认证 ROHS Compliant 通过 Yes 辐射方向图 Radiation Patterns (unit:dB) 2.4G phi=0deg 2.4G phi=90deg 2 / 3 2.4G theta=90deg 2.4G 3D 5G phi=0deg 5G phi=90deg 3 / 3 5G theta=90deg 5G 3D 总成图 Mechanical Drawing(unit:mm) ▲规格书到此结束END OF THE SPECIFICATION.

Test Report

1 / 3 GWN7604-ANT1 Antenna Specification Brand Name: GRANDSTREAM Manufacture: SHENZHEN CHAOLIU NETWORK TECHNOLOGIES CO., LTD Manufacturing address:14th Floor, Building-C, Coolpad Building, Gaoxin North District, Science Park, Nanshan District, Shenzhen Product Number(or model Nanme): 118-00070-00 设计规格 specifications 频率范围 Frequency(MHz) 2.4G: 2400~2500 5G:5150~5895 电压驻波比 VSWR ≦2.0:1 峰值增益 Peak Gain(dBi) 2.4G: 3.97 5G: 3.54 效率 Efficiency(%) ≧60 天线类型 Type Dipole Antenna 辐射方向 Radiation Properties 全向 Omni-directional 最大输入功率 Max Input Power(Watts) 2 极化方式 Polarization 垂直 Vertical 阻抗 Impedance(Ohms) 50 工作温度 Operation Temperature-40°C to 85°C 储存温度 Storage Temperature -40°C to 85°C 相对湿度 Relative Humidity 40% to 95% 环保认证 ROHS Compliant 通过 Yes 辐射方向图 Radiation Patterns (unit:dB) 2.4G phi=0deg 2.4G phi=90deg 2 / 3 2.4G theta=90deg 2.4G 3D 5G phi=0deg 5G phi=90deg 3 / 3 5G theta=90deg 5G 3D 总成图 Mechanical Drawing(unit:mm) ▲规格书到此结束END OF THE SPECIFICATION.

Test Report

1 / 2 GWN7604-5G1 Antenna Specification Brand Name: GRANDSTREAM Manufacture: SHENZHEN CHAOLIU NETWORK TECHNOLOGIES CO., LTD Manufacturing address:14th Floor, Building-C, Coolpad Building, Gaoxin North District, Science Park, Nanshan District, Shenzhen Product Number(or model Nanme): 118-00181-00 设计规格 specifications 频率范围 Frequency(MHz) 5150~5895 电压驻波比 VSWR ≦2.0:1 峰值增益 Peak Gain(dBi) 4.84 效率 Efficiency(%) ≧60 天线类型 Type Dipole Antenna 辐射方向 Radiation Properties 全向 Omni-directional 最大输入功率 Max Input Power(Watts) 2 极化方式 Polarization 垂直 Vertical 阻抗 Impedance(Ohms) 50 工作温度 Operation Temperature-40°C to 85°C 储存温度 Storage Temperature -40°C to 85°C 相对湿度 Relative Humidity 40% to 95% 环保认证 ROHS Compliant 通过 Yes 辐射方向图 Radiation Patterns (unit:dB) phi=0deg phi=90deg 2 / 2 theta=90deg 3D 总成图 Mechanical Drawing(unit:mm) ▲规格书到此结束END OF THE SPECIFICATION.

Test Report

Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF015 Page 1 of 628 Version 3.0 TEST REPORT Applicant Name: Grandstream Networks, Inc. Address: 126 Brookline Ave., 3rd Floor Boston, MA 02215, USA Report Number: 2401U28582E-RF-00A FCC ID: YZZGWN7604 Test Standard (s) FCC PART 15.407 Sample Description Product Type: Mid-Tier AX3000 Wi-Fi 6 Access Point Model No.: GWN7604 Multiple Model(s) No.: N/A Trade Mark: GRANDSTREAM Date Received: 2024/06/17 Issue Date: 2024/08/23 Test Result: Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Andy Yu Jimmy Xiao RF Engineer RF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 2 of 628 Version 3.0 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 GENERAL INFORMATION ....................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 5 OBJECTIVE ................................................................................................................................................................... 5 TEST METHODOLOGY .................................................................................................................................................. 5 MEASUREMENT UNCERTAINTY .................................................................................................................................... 6 TEST FACILITY ............................................................................................................................................................. 6 SYSTEM TEST CONFIGURATION .......................................................................................................................... 7 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 7 EUT EXERCISE SOFTWARE .......................................................................................................................................... 9 EQUIPMENT MODIFICATIONS ..................................................................................................................................... 11 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................. 11 EXTERNAL I/O CABLE ................................................................................................................................................ 11 BLOCK DIAGRAM OF TEST SETUP .............................................................................................................................. 12 SUMMARY OF TEST RESULTS ............................................................................................................................. 14 TEST EQUIPMENT LIST ......................................................................................................................................... 15 FCC §1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) ........................................................ 17 APPLICABLE STANDARD ............................................................................................................................................ 17 RESULT ...................................................................................................................................................................... 17 FCC §15.203 - ANTENNA REQUIREMENT ........................................................................................................... 19 APPLICABLE STANDARD ............................................................................................................................................ 19 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 19 FCC §15.407 (B) (6) §15.207 (A) - CONDUCTED EMISSIONS ............................................................................. 20 APPLICABLE STANDARD ............................................................................................................................................ 20 EUT SETUP ................................................................................................................................................................ 20 EMI TEST RECEIVER SETUP ....................................................................................................................................... 20 TEST PROCEDURE ..........................................…

Text truncated - open the document above for the full version.

Test Report

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 126 of 628 Version 3.0 99% Emission Bandwidth 802.11ac-VHT40 Lowest Channel 802.11ac-VHT40 Highest Channel 802.11ac-VHT80 Middle Channel Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 127 of 628 Version 3.0 99% Emission Bandwidth 802.11ac-VHT160 Middle Channel 802.11ax-HE20 Lowest Channel 802.11ax-HE20 Middle Channel Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 128 of 628 Version 3.0 99% Emission Bandwidth 802.11ax-HE20 Highest Channel 802.11ax-HE40 Lowest Channel 802.11ax-HE40 Highest Channel Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 129 of 628 Version 3.0 99% Emission Bandwidth 802.11ax-HE80 Middle Channel 802.11ax-HE160 Middle Channel Note: The test data and plots of 5150-5250MHz, 5250-5350MHz, 5470-5725MHz and 5725-5850MHz band please refer to the Appendix. Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 130 of 628 Version 3.0 FCC §15.407(a)&(h)(1) - CONDUCTED TRANSMITTER OUTPUT POWER & TRANSMIT POWER CONTROL (TPC) Applicable Standard FCC§15.407 (a): For an indoor access point operating in the band 5.15-5.25 GHz, the maximum conducted output power over the frequency band of operation shall not exceed 1 W provided the maximum antenna gain does not exceed 6 dBi. In addition, the maximum power spectral density shall not exceed 17 dBm in any 1 megahertz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the maximum conducted output power and the maximum power spectral density shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. For client devices in the 5.15-5.25 GHz band, the maximum conducted output power over the frequency band of operation shall not exceed 250 mW provided the maximum antenna gain does not exceed 6 dBi. In addition, the maximum power spectral density shall not exceed 11 dBm in any 1 megahertz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the maximum conducted output power and the maximum power spectral density shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. For the 5.25-5.35 GHz and 5.47-5.725 GHz bands, the maximum conducted output power over the frequency bands of operation shall not exceed the lesser of 250 mW or 11 dBm + 10 log B, where B is the 26 dB emission bandwidth in megahertz. In addition, the maximum power spectral density shall not exceed 11 dBm in any 1 megahertz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the maximum conducted output power and the maximum power spectral density shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. For the band 5.725-5.85 GHz, the maximum conducted output power over the frequency band of operation shall not exceed 1 W. In addition, the maximum power spectral density shall not exceed 30 dBm in any 500-kHz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the maximum conducted output power and the maximum power spectral density shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. However, fixed point-to-point U-NII devices operating in this band may employ transmitting antennas with directional gain greater than 6 dBi without any corresponding reduction in transmitter conducted power. Fixed, point-to-point operations exclude the use of point-to-multipoint systems, omnidirectional applications, and multiple collocated transmitters transmitting the same information. The operator of the U-NII device, or if the equipment is professionally installed, the installer, is responsible for ensuring that systems employing high gain directional antennas are used exclusively for fixed, point-to-point operations. For an indoor access point operating in the 5.850-5.895 GHz band, the maximum power spectral density must not exceed 20 dBm e.i.r.p. in any 1-megahertz band. In addition, the maximum e.i.r.p. over the frequency band of operation must not exceed 36 dBm. Indoor access points operating on a channel that spans the 5.725-5.850 GHz and 5.850-5.895 GHz bands must not exceed an e.i.r.p. of 36 dBm. FCC§15.407 (h) (1) Transmit power control (TPC): U-NII devices operating in the 5.25-5.35 GHz band and the 5.47-5.725 GHz band shall employ a TPC mechanism. The U-NII device is required to have the capability to operate at least 6 dB below the mean EIRP value of 30dBm. A TPC mechanism is not required for systems with an e.i.r.p. of less than 500 mW. Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 131 of 628 Version 3.0 Test Procedure According to KDB 789033 D02 General UNII Test Procedures New Rules v02r01 Method PM-G should be applied a. Place the EUT on a bench and set it in transmitting mode. b. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to one test equipment. Test Data Environmental Conditions Temperature: 22~25.5 °C Relative Humidity: 50~58 % ATM Pressure: 101 kPa The testing was performed by Kungfumaster Liang and Lee Li from 2024-07-16 to 2024-08-03. EUT operation mode: Transmitting Test Result: Compliant. EUT Power Meter Attenuator Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 132 of 628 Version 3.0 5850-5895 MHz: Test Modes Test Frequency (MHz) Max. Conducted Average Output Power(dBm) Chain 0 Chain 1 Chain 2 Total EIRP EIRP LIMIT 802.11a 5845 20.14 15.65 20.39 / 25.23 36 5865 20.16 15.69 20.41 / 25.25 36 5885 20.15 15.62 20.43 / 25.27 36 802.11ac vht20 5845 16.42 16.14 16.29 21.06 30.67 36 5865 16.13 16.26 16.43 21.05 30.66 36 5885 16.16 16.23 16.47 21.06 30.67 36 802.11ac vht40…

Text truncated - open the document above for the full version.

Test Report

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 162 of 628 Version 3.0 11A_Ant1_5200 11A_Ant2_5200 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 163 of 628 Version 3.0 11A_Ant0_5240 11A_Ant1_5240 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 164 of 628 Version 3.0 11A_Ant2_5240 11A_Ant0_5260 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 165 of 628 Version 3.0 11A_Ant1_5260 11A_Ant2_5260 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 166 of 628 Version 3.0 11A_Ant0_5280 11A_Ant1_5280 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 167 of 628 Version 3.0 11A_Ant2_5280 11A_Ant0_5320 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 168 of 628 Version 3.0 11A_Ant1_5320 11A_Ant2_5320 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 169 of 628 Version 3.0 11A_Ant0_5500 11A_Ant1_5500 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 170 of 628 Version 3.0 11A_Ant2_5500 11A_Ant0_5580 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 171 of 628 Version 3.0 11A_Ant1_5580 11A_Ant2_5580 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 172 of 628 Version 3.0 11A_Ant0_5700 11A_Ant1_5700 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 173 of 628 Version 3.0 11A_Ant2_5700 11AC20MIMO_Ant0_5180 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 174 of 628 Version 3.0 11AC20MIMO_Ant1_5180 11AC20MIMO_Ant2_5180 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 175 of 628 Version 3.0 11AC20MIMO_Ant0_5200 11AC20MIMO_Ant1_5200 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 176 of 628 Version 3.0 11AC20MIMO_Ant2_5200 11AC20MIMO_Ant0_5240 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 177 of 628 Version 3.0 11AC20MIMO_Ant1_5240 11AC20MIMO_Ant2_5240 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 178 of 628 Version 3.0 11AC20MIMO_Ant0_5260 11AC20MIMO_Ant1_5260 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 179 of 628 Version 3.0 11AC20MIMO_Ant2_5260 11AC20MIMO_Ant0_5280 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 180 of 628 Version 3.0 11AC20MIMO_Ant1_5280 11AC20MIMO_Ant2_5280 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 181 of 628 Version 3.0 11AC20MIMO_Ant0_5320 11AC20MIMO_Ant1_5320 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 182 of 628 Version 3.0 11AC20MIMO_Ant2_5320 11AC20MIMO_Ant0_5500 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 183 of 628 Version 3.0 11AC20MIMO_Ant1_5500 11AC20MIMO_Ant2_5500 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 184 of 628 Version 3.0 11AC20MIMO_Ant0_5580 11AC20MIMO_Ant1_5580 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 185 of 628 Version 3.0 11AC20MIMO_Ant2_5580 11AC20MIMO_Ant0_5700 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 186 of 628 Version 3.0 11AC20MIMO_Ant1_5700 11AC20MIMO_Ant2_5700 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 187 of 628 Version 3.0 11AC40MIMO_Ant0_5190 11AC40MIMO_Ant1_5190 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 188 of 628 Version 3.0 11AC40MIMO_Ant2_5190 11AC40MIMO_Ant0_5230 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 189 of 628 Version 3.0 11AC40MIMO_Ant1_5230 11AC40MIMO_Ant2_5230 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 190 of 628 Version 3.0 11AC40MIMO_Ant0_5270 11AC40MIMO_Ant1_5270 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 191 of 628 Version 3.0 11AC40MIMO_Ant2_5270 11AC40MIMO_Ant0_5310 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 192 of 628 Version 3.0 11AC40MIMO_Ant1_5310 11AC40MIMO_Ant2_5310 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 193 of 628 Version 3.0 11AC40MIMO_Ant0_5510 11AC40MIMO_Ant1_5510 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 194 of 628 Version 3.0 11AC40MIMO_Ant2_5510 11AC40MIMO_Ant0_5550 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 195 of 628 Version 3.0 11AC40MIMO_Ant1_5550 11AC40MIMO_Ant2_5550 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 196 of 628 Version 3.0 11AC40MIMO_Ant0_5670 11AC40MIMO_Ant1_5670 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 197 of 628 Version 3.0 11AC40MIMO_Ant2_5670 11AC80MIMO_Ant0_5210

Test Report

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 198 of 628 Version 3.0 11AC80MIMO_Ant1_5210 11AC80MIMO_Ant2_5210 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 199 of 628 Version 3.0 11AC80MIMO_Ant0_5290 11AC80MIMO_Ant1_5290 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 200 of 628 Version 3.0 11AC80MIMO_Ant2_5290 11AC80MIMO_Ant0_5530 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 201 of 628 Version 3.0 11AC80MIMO_Ant1_5530 11AC80MIMO_Ant2_5530 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 202 of 628 Version 3.0 11AC80MIMO_Ant0_5610 11AC80MIMO_Ant1_5610 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 203 of 628 Version 3.0 11AC80MIMO_Ant2_5610 11AC160MIMO_Ant0_5250 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 204 of 628 Version 3.0 11AC160MIMO_Ant1_5250 11AC160MIMO_Ant2_5250 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Page 205 of 628 Version 3.0 11AC160MIMO_Ant0_5570 11AC160MIMO_Ant1_5570 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401U28582E-RF-00A TR-EM-RF015 Pag…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Junwei Wang
[email protected]1-617-5669300Fax: 1-617-2491987

Test Firm

Bay Area Compliance Laboratories Corp (Shenzhen)Well Wang
[email protected]86-755-33320018

Technical Specifications

#Rule PartsFrequency RangePower Output
815E5.82 GHz - 5.82 GHz798.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted power except 5815-5885MHz band which is EIRP. The device supports 20MHz, 40MHz, 80MHz and 160MHz bandwidths. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 28 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.

Other Applications from Grandstream Networks, Inc.

YZZGWN7712P

Layer 2 Lite Managed Network PoE Switch

Sep 04, 2026

Equipment Class

JAD - Part 15 Class A Digital Device
YZZGWN7801PC

Enterprise Layer 2+ Compact Managed Switch

Aug 27, 2026

Equipment Class

JAD - Part 15 Class A Digital Device
YZZGWN7823P

Layer 3 Multi-Gigabit Network Switch

Aug 26, 2026

Equipment Class

JAD - Part 15 Class A Digital Device
YZZGWN7703P

24 Unmanaged Gigabit Port and 2 SFP Port Switch with 24 PoE+

Aug 26, 2026

Equipment Class

JAD - Part 15 Class A Digital Device
YZZGWN7673

Dual-Band Wi-Fi 7 Access Point

Jul 29, 2026

Equipment Class

DTS - Digital Transmission System