Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
~ 1 ~ ~ 2 ~ Grandstream Networks, Inc. (XUUQROTK'\KXJ,RUUX (UYZUT3';9' :KR ,G^ ]]]MXGTJYZXKGSIUS For Certification, Warranty and RMA information, please visit www.grandstream.com GWN7811P Enterprise Layer 3 Managed Network Switch Quick Installation Guide ~ 1 ~ ~ 2 ~ OVERVIEW The GWN7811P is Layer 3 managed network switch that allow medium-to-large enterprises to build scalable, secure, high performance, and smart business networks that are fully manageable. It supports advanced VLAN for flexible and sophisticated traffic segmentation, advanced QoS for prioritization of network traffic, IGMP/MLD Snooping for network performance optimization, and comprehensive security capabilities against potential attacks. The PoE models provides smart dynamic PoE output to power IP phones, IP cameras, Wi-Fi access points and other PoE endpoints. GWN7811P can be managed in a number of ways, including the local Web user interface of the GWN7811P switch and CLI, the command-line interface. The series is also supported by GWN.Cloud and GWN Manager, Grandstream’s cloud and on-premise network management platform. The GWN7811P is the best value enterprise-grade managed network switch for medium-to-large businesses. PRECAUTIONS Ь Do not attempt to open, disassemble, or modify the device. Ь Do not expose this device to temperat ure outside range of 0 °C to 45 °C for operation and -10 °C to 60 °C for storage. Ь Do not expose this device to envi ronments outside of the following humidity range: 10-90% RH (non-condensing) for operation and 5-95% RH (non-condensing) for storage. Ь Do not power cycle your GWN7811P during system boot up or firmware upgrade. You may corrupt firmware images and cause the unit to malfunction. PAKEAGE CONTENTS GWN7811P 1x Switch 1x 1.2m(10A) AC Cable 1x 25cm Ground Cable 4x Rubber Footpads 8x Screws(KM 3*6) 2x Extended Rack Mounting Kits or 1x Console Cable(Optional) 1x Power Cord Anti-Trip 1x Quick Installation Guide PORTS & LED Indicator GWN7811P No. Port&LED Description EN ~ 3 ~ ~ 4 ~ 1 Port 1-8 8x Ethernet RJ45(10/100/1000Mbps), used for connecting terminals Note: GWN7811P Ethernet ports support PoE/PoE+ 2 1-8 Ethernet ports’ LED indicators 3 Port SFP+ 1/2 2x 10Gbps SFP+ ports 4 SFP+ 1/2 SFP+ ports’ LED indicators 5 Console 1x Console port, used for connecting managing PC 6 RST Factory Reset pinhole Press for 5 seconds to reset factory default settings 7 SYS System LED indicator 8 Power cord anti-trip hole 9 100-240VAC 50-60Hz Power outlet 10 Lighting protection grounding post LED Indicator LED Indicator Status Description Off Power off Solid green Booting Flashing green Upgrade Solid blue Normal use Flash blue Privisioning Solid red Upgrade failed Flashing red Factory reset Port Indicator Off For all ports, port off & For SFP+ ports, port failure Solid green Port connected and there is no activity Flashing green Port connected and data is transferring Solid yellow Ethernet port connected and PoE powered Flashing yellow Ethernet port connected , data is transferring and PoE powered Alternately flashing yellow and green Ethernet port failure POWERING & CONNECTING Grounding the Switch 1. Remove the ground screw from the back of swit ch, and connect one end of the ground cable to the wiring terminal of switch. 2. Put the ground screw back into the screw hole, and tighten it with a screwdriver. ~ 5 ~ ~ 6 ~ 3. Connect the other end of the ground cable to other device that has been grounded or directly to the terminal of the ground bar in the equipment room. Powering on the Switch Connect the power cable and the switch first, then connect the power cable to the power supply system of the equipment room. Connecting Power Cord Anti-Trip In order to protect the power supply from accidental disconnection, it’s recommended to use a power cord anti-trip for installation. 1. Place the smooth side of th e fixing strap towards the power outlet and insert it into the hole on the side of it. 2. After plugging the power cord into the power outlet, slide the protector over the remaining strap until it slides over the end of the power cord. Ground terminal Ground cable Ground bar ~ 7 ~ ~ 8 ~ 3. Wrap the strap of the protective cord around the power cord and lock it tightly. Fasten the straps until the power cord is securely fastened. PORT CONNECTING Connect to RJ45 Port 1. Connect one end of the network cable to the switch, and the other end to the peer device. 2. After powered on, check the status of the port indicator. If on, it means that the link is connected norm ally; if off, it means the link is disconnected, please check the cable and the peer device whether is enabled. Connect to SFP+ Port The installation process of the fiber module is as follows: 1. Grasp the fiber module from the si de and insert it smoothly along the switch SFP+ port slot until th e module is in close contact with the switch. 2. When connecting, pay attention to confirm the Rx and Tx ports of SFP fiber module. Insert one end of the fiber into the Rx and Tx ports correspondingly, and connect the other end to another device. 3.After powered on, check the status of the port indicator. If on, it means that the link is connected norm ally; if off, it means the link is disconnected, please check the cable and the peer device whether is enabled. Notes: 1. Please select the optical fiber cable according to the module type. The multi-mode module corresponds to the multi-mode optical fiber, and the single-mode module corresponds to the single-mode optical fiber. 2. Please select the same wavelength optical fiber cable for connection. RJ45 port Crystal head RJ45 port Fiber module SFP+ port ~ 9 ~ ~ 10 ~ 3. Please select an appropriate optica l module according to the actual networking situation to meet differen t transmission distance requirements. 4. The laser of the first-class laser products is harmful to eyes. Do not look directly at the optical fiber conn…
Text truncated - open the document above for the full version.
Grandstream Networks, Inc. 126 Brookline Ave, 3rd Floor Boston, MA 02215, USA Tel: 1-617-5669300 Fax: 1-617-2491987 Email: [email protected] CFR 47 §2.911(d)(5)(i) Attestation Letter QA-FR-1006-A RC 02-08-2023 Attestation Letter Date: 2023/02/10 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID: YZZGWN7811P Grandstream Networks, Inc. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature Contact Person: Ning Wei Title:Manager Company Name & Address: Grandstream Networks, Inc. &126 Brookline Ave, 3rd Floor Boston, MA 02215, USA
Grandstream Networks, Inc. 126 Brookline Ave, 3rd Floor Boston, MA 02215, USA Tel: 1-617-5669300 Fax: 1-617-2491987 Email: [email protected] CFR 47 §2.911 (d)(5)(ii) Attestation Letter QA-FR-1007-A RC 02-08-2023 Attestation Letter Date: 2023/02/10 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: YZZGWN7811P Grandstream Networks, Inc. certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature Contact Person: Ning Wei Title:Manager Company Name & Address: Grandstream Networks, Inc.&126 Brookline Ave, 3rd Floor Boston, MA 02215, USA
Grandstream Networks, Inc. 126 Brookline Ave, 3rd Floor Boston, MA 02215, USA Tel: 1-617-5669300 Fax: 1-617-2491987 Email: [email protected] QA-FR-1004-A RC 02-08-2023 Attestation Letter for Agent 2023/02/10 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements Part 2.911 (d)(7) Filing FCC ID: YZZGWN7811P Grandstream Networks, Inc. certifies that, as of the date of the filing of the application, Grandstream Networks, Inc. is our designated U.S. agent for service of process for the above referenced FCC ID: YZZGWN7811P. Grandstream Networks, Inc. agrees to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Grandstream Networks, Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name : Grandstream Networks, Inc.: Address: 126 Brookline Ave, 3rd Floor Boston, MA 02215, USA Contact person: Ning Wei Tel: 1-617-5669300 Email: [email protected] Sincerely, Applicant Name Grandstream Networks, Inc. Applicant Printed Name Ning Wei Applicant Signature
Grandstream Networks, Inc. 126 Brookline Ave, 3rd Floor Boston, MA 02215, USA Tel: 1-617-5669300 Fax: 1-617-2491987 Email: [email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2023-02-10 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We Grandstream Networks, Inc., the undersigned, hereby authorizes Shenzhen Accurate Technology Co., Ltd. to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Shenzhen Accurate Technology Co., Ltd. on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Ning Wei Manager
Grandstream Networks, Inc. 126 Brookline Ave, 3rd Floor Boston, MA 02215, USA Tel: 1-617-5669300 Fax: 1-617-2491987 Email: [email protected] FCC Confidential Authorization Date: 2023-02-10 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: YZZGWN7811P In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Grandstream Networks, Inc. hereby requests long-term confidential treatment of information accompanying this application as outlined below: Block Diagram Schematics Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Ning Wei Manager
Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02723E-EM-00 Page 1 of 4 External Photos Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02723E-EM-00 Page 2 of 4 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02723E-EM-00 Page 3 of 4 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02723E-EM-00 Page 4 of 4
FCC ID Label FCC ID Label Location Information
Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02723E-EM-00 Page 1 of 4 Internal photos Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02723E-EM-00 Page 2 of 4 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02723E-EM-00 Page 3 of 4 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02723E-EM-00 Page 4 of 4
Note: This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. Shenzhen Accurate Technology Co., Ltd. is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. Shenzhen Accurate Technology Co., Ltd. 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China Tel: +86 755-26503290 Fax: +86 755-26503396 Web: www.atc-lab.com Version 1 2021-11-09 Page 1 of 21 FCC-EMC TEST REPORT Applicant Name : Grandstream Networks, Inc. Address : 126 Brookline Ave., 3rd Floor Boston, MA 02215, USA Report Number : RA230117-02723E-EM-00 FCC ID: YZZGWN7811P Test Standard (s) FCC PART 15B, CLASS A Sample Description Product Type: Enterprise Layer 3 Managed Network Switch Model No.: GWN7811P Trade Mark: GRANDSTREAM Date Received: 2023-01-17 Date of Test: 2023-01-30 to 2023-01-31 Report Date: 2023-02-03 Test Result: Pass* * In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Zeki Ma Candy Li EMC Engineer EMC Engineer Shenzhen Accurate Technology Co., Ltd. Report No.: RA230117-02723E-EM-00 Version 1 2021-11-09 Page 2 of 21 FCC-EMC TABLE OF CONTENTS 1. TEST RESULTS SUMMARY ................................................................................................... 5 2. GENERAL INFORMATION ...................................................................................................... 6 2.1. Description of Device (EUT) .......................................................................................................... 6 2.2. Test mode ......................................................................................................................................... 6 2.3. General disclaimer ........................................................................................................................... 6 2.4. Accessory and Auxiliary Equipment and Cables and Software ............................................... 7 2.5. Description of Test Facility ............................................................................................................. 7 2.6. Measurement Uncertainty .............................................................................................................. 7 3. MEASURING DEVICE AND TEST EQUIPMENT ................................................................ 8 3.1. For Conducted Emission Test ....................................................................................................... 8 3.2. For Radiated Emission Measurement .......................................................................................... 8 4. CONDUCTED EMISSION MEASUREMENT ........................................................................ 9 4.1. Block Diagram of Test Setup ......................................................................................................... 9 4.2. Power Line Conducted Emission Measurement Limits (Class A) .......................................... 10 4.3. Test mode description .................................................................................................................. 10 4.4. Manufacturer .................................................................................................................................. 10 4.5. Operating Condition of EUT ......................................................................................................... 10 4.6. Test Procedure .............................................................................................................................. 11 4.7. Data Explain ................................................................................................................................... 11 4.8. Power Line Conducted Emission Measurement Results ........................................................ 11 5. RADIATED EMISSION MEASUREMENT ........................................................................... 14 5.1. Block Diagram of Test Setup ....................................................................................................... 14 5.2. Radiated Emission Limit (Class A) ............................................................................................. 15 5.3. Test mode description .................................................................................................................. 16 5.4. Manufacturer .................................................................................................................................. 16 5.5. Operating Condition of EUT ......................................................................................................... 16 5.6. Test Procedure .............................................................................................................................. 17 5.7. Data Sample ................................................................................................................................... 17 5.8. Radiated Emission Measurement Result ................................................................................... 17 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230117-02723E-EM-00 Version 1 2021-11-09 Page 3 of 21 FCC-EMC DOCUMENT REVISION HISTORY Revision Number Report Number Description of Revision Date of Revision 0 RA230117-02723E-EM-00 Original Report 2023-02-03 Shenzhen Accurate Technology …
Text truncated - open the document above for the full version.
Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02723E-EM-00 Test Photos Page 1 of 3 Photo of Conducted Emission Measurement Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02723E-EM-00 Test Photos Page 2 of 3 Photo of Radiated Emission Measurement (Below 1GHz) Shenzhen Accurate Technology Co., Ltd. Project No.: RA230117-02723E-EM-00 Test Photos Page 3 of 3 Photo of Radiated Emission Measurement (Above 1GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |
Layer 2 Lite Managed Network PoE Switch
Equipment Class
JAD - Part 15 Class A Digital DeviceEnterprise Layer 2+ Compact Managed Switch
Equipment Class
JAD - Part 15 Class A Digital DeviceLayer 3 Multi-Gigabit Network Switch
Equipment Class
JAD - Part 15 Class A Digital Device24 Unmanaged Gigabit Port and 2 SFP Port Switch with 24 PoE+
Equipment Class
JAD - Part 15 Class A Digital DeviceDual-Band Wi-Fi 7 Access Point
Equipment Class
DTS - Digital Transmission System