Z8WUWX2000-TXWireless Style Remote Control

SHENZHEN DBK ELECTRONICS CO., LTD.
Wireless Style Remote Control - FCC ID Z8WUWX2000-TX - SHENZHEN DBK ELECTRONICS CO., LTD.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Nov 17, 2011
Application Purpose
Original Equipment
Date of Application
Nov 17, 2011
Equipment Note
Wireless Style Remote Control
Frequency Range
433.00000000 - 433.00000000
Company
SHENZHEN DBK ELECTRONICS CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

PHOTOGRAPH OF THE PRODUCT FRONT VIEW OF THE PRODUCT REAR VIEW OF THE PRODUCT

Internal Photos

PHOTOGRAPH OF THE PRODUCT INNER CIRCUIT TOP VIEW PHOTOGRAPH OF THE PRODUCT INNER CIRCUIT BOTTOM VIEW

Test Report

STC Test Report Date : 2011-10-20 Page 1 of 19 No. : MH184516 The Hong Kong Standards and Testing Centre Ltd. 10 Dai Wang Street, Taipo Industrial Estate, N.T., Hong Kong Tel: (852) 2666 1888 Fax: (852) 2664 4353 Homepage: www.hkstc.org E-mail: [email protected] This report shall not be reproduced unless with prior written approval from the Hong Kong Standards and Testing Centre Ltd. For full text of “Conditions of Issuance of Test Report”, please refer to overleaf or refer to the website of Homepage. Applicant (C01492): SHENZHEN DBK ELECTRONICS CO., LTD. DBK Industrial Park Zone, North of LongGuan Rd, SanLian Community, LongHua, 518109, SHENZHEN, CHINA Description of Sample(s): Submitted sample(s) said to be Product: Wireless Style Remote Control Brand Name: N/A Model Number: UWX2000-TX FCC ID: Z8WUWX2000-TX Date Sample(s) Received: 2010-09-10 Date Tested: 2010-09-14, 2011-10-12 Investigation Requested: Perform ElectroMagnetic Interference measurement in accordance with FCC 47CFR [Codes of Federal Regulations] Part 15: 2010 and ANSI C63.4:2009 for FCC Certification. Conclusion(s): The submitted product COMPLIED with the requirements of Federal Communications Commission [FCC] Rules and Regulations Part 15. The tests were performed in accordance with the standards described above and on Section 2.2 in this Test Report. Remark(s): For additional models details, see page 5. Dr. LEE Kam Chuen Authorized Signatory ElectroMagnetic Compatibility Department For and on behalf of The Hong Kong Standards and Testing Centre Ltd. STC Test Report Date : 2011-10-20 Page 2 of 19 No. : MH184516 The Hong Kong Standards and Testing Centre Ltd. 10 Dai Wang Street, Taipo Industrial Estate, N.T., Hong Kong Tel: (852) 2666 1888 Fax: (852) 2664 4353 Homepage: www.hkstc.org E-mail: [email protected] This report shall not be reproduced unless with prior written approval from The Hong Kong Standards and Testing Centre Ltd. For Conditions of Issuance of this test report, please refer to the overleaf or Homepage CONTENT: Cover Page 1 of 19 Content Page 2-3 of 199 1.0 General Details 1.1 Equipment Under Test [EUT] Page 4 of 19 Description of EUT operation 1.2 Date of Order Page 4 of 19 1.3 Submitted Samples Page 4 of 19 1.4 Test Duration Page 4 of 19 1.5 Country of Origin Page 4 of 19 2.0 Technical Details 2.1 Investigations Requested Page 5 of 19 2.2 Test Standards and Results Summary Page 5 of 19 3.0 Test Results 3.1 Emission Page 6-9 of 19 3.2 Bandwidth Measurement Page 10-11 of 19 STC Test Report Date : 2011-10-20 Page 3 of 19 No. : MH184516 The Hong Kong Standards and Testing Centre Ltd. 10 Dai Wang Street, Taipo Industrial Estate, N.T., Hong Kong Tel: (852) 2666 1888 Fax: (852) 2664 4353 Homepage: www.hkstc.org E-mail: [email protected] This report shall not be reproduced unless with prior written approval from The Hong Kong Standards and Testing Centre Ltd. For Conditions of Issuance of this test report, please refer to the overleaf or Homepage Appendix A List of Measurement Equipment Page 12 of 19 Appendix B Duty Cycle Correction During 100 msec Page 13-16 of 19 Appendix C A manually Operation Page 17 of 19 Appendix D Photographs of EUT Page 18-19 of 19 STC Test Report Date : 2011-10-20 Page 4 of 19 No. : MH184516 The Hong Kong Standards and Testing Centre Ltd. 10 Dai Wang Street, Taipo Industrial Estate, N.T., Hong Kong Tel: (852) 2666 1888 Fax: (852) 2664 4353 Homepage: www.hkstc.org E-mail: [email protected] This report shall not be reproduced unless with prior written approval from The Hong Kong Standards and Testing Centre Ltd. For Conditions of Issuance of this test report, please refer to the overleaf or Homepage 1.0 General Details 1.1 Equipment Under Test [EUT] Description of Sample(s) Submitted sample(s) said to be Product: Wireless Style Remote Control Manufacturer: SHENZHEN DBK ELECTRONICS CO., LTD. DBK Industrial Park Zone, North of LongGuan Rd, SanLian Community, LongHua, 518109, SHENZHEN, CHINA Brand Name: N/A Model Number: UWX2000-TX Rating: Battery 12Vd.c. (“23A” size battery x 1) 1.2.1 Description of EUT Operation The Equipment Under Test (EUT) is a SHENZHEN DBK ELECTRONICS CO., LTD., 433MHz Wireless Style Remote Control. The transmitter is a manually operated transmitter. The EUT will automatically cease transmission after one packet has been sent. It is a pulse transmitter. Modulation by IC; and type is ASK modulation. 1.3 Date of Order 2010-09-10 1.4 Submitted Sample(s): 1 Sample 1.5 Test Duration 2010-09-14, 2011-10-12 1.6 Country of Origin China STC Test Report Date : 2011-10-20 Page 5 of 19 No. : MH184516 The Hong Kong Standards and Testing Centre Ltd. 10 Dai Wang Street, Taipo Industrial Estate, N.T., Hong Kong Tel: (852) 2666 1888 Fax: (852) 2664 4353 Homepage: www.hkstc.org E-mail: [email protected] This report shall not be reproduced unless with prior written approval from The Hong Kong Standards and Testing Centre Ltd. For Conditions of Issuance of this test report, please refer to the overleaf or Homepage 2.0 Technical Details 2.1 Investigations Requested Perform ElectroMagnetic Interference measurement in accordance with FCC 47CFR [Codes of Federal Regulations] Part 15 2010 and ANSI C63.4:2009 for FCC Certification. 2.2 Test Standards and Results Summary Tables EMISSION Results Summary Test Condition Test Requirement Test Method Class / Test Result Severity Pass Failed N/A Field Strength of Fundamental Emissions & Spurious Emissions FCC 47CFR 15.231a ANSI C63.4:2009 N/A Radiated Emissions FCC 47CFR 15.209 ANSI C63.4:2009 N/A Note: N/A - Not Applicable STC Test Report Date : 2011-10-20 Page 6 of 19 No. : MH184516 The Hong Kong Standards and Testing Centre Ltd. 10 Dai Wang Street, Taipo Industrial Estate, N.T., Hong Kong Tel: (852) 2666 1888 Fax: (852) 2664 4353 Homepage: www.hkstc.org E-mail: [email protected] This report shall not be reproduced unless with prior written approval from The Hong Kong Standards and Testing Centre Ltd. For Conditions of Issuance of this test report, please refer…

Text truncated - open the document above for the full version.

Test Setup Photos

Measurement of Radiated Emission Test Set Up

Contact Information

Applicant

Guoqing Wu(Manager)
[email protected]86 755 61569366Fax: 86 755 61569387

Test Firm

Hong Kong Standards and Testing CenterWison Wong
[email protected]85226661888Fax: 85226644353

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433 MHz - 433 MHz-
Confidentiality
Long Term