FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TK Home Solutions B.V./
  3. ZAH-1131445

ZAH-1131445Stairlift RP00-CU

TK Home Solutions B.V.
Stairlift RP00-CU - FCC ID ZAH-1131445 - TK Home Solutions B.V.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jul 27, 2021
Application Purpose
Original Equipment
Date of Application
Jul 27, 2021
Equipment Note
Stairlift RP00-CU
Frequency Range
902.30000000 - 927.60000000
Company
TK Home Solutions B.V.
Country
Netherlands

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TK Home Solutions B.V. User’s manual Remote Control and UI-Joystick part Reference: 003 – RP00-CU user’s manual partially page 1 of 11 Version: A.1 State: Released RP00-CU Stairlift user’s manual part of Remote Control and UI-Joystick TK Home Solutions B.V. User’s manual Remote Control and UI-Joystick part Reference: 003 – RP00-CU user’s manual partially page 2 of 11 Version: A.1 State: Released TABLE OF CONTENTS 1 Introduction ........................................................................................................ 4 2 Remote Control .................................................................................................. 5 2.1 Power ...................................................................................................................... 5 2.2 Call & Park .............................................................................................................. 7 2.3 Attendant control ..................................................................................................... 8 2.4 Remote Control indicator signals ............................................................................. 9 3 User Interface Joystick ..................................................................................... 10 3.1 Buttons and indicators ............................................................................................10 3.2 UI-Joystick indicator signals ...................................................................................11 TK Home Solutions B.V. User’s manual Remote Control and UI-Joystick part Reference: 003 – RP00-CU user’s manual partially page 3 of 11 Version: A.1 State: Released FCC and ISED Declarations Compliance statement (part 15.19) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning (part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Information to the User (Part 15.105 (b)) Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. Complies with: CAN ICES-3 (B)/NMB-3(B) TK Home Solutions B.V. User’s manual Remote Control and UI-Joystick part Reference: 003 – RP00-CU user’s manual partially page 4 of 11 Version: A.1 State: Released 1 Introduction This manual describes the use of the Remote Control unit, used in combination with our UI-Joystick as mounted in a RP00-CU stairlift 1 . If a stairlift is not in the required place, the Remote Control can be used to Call & Park at the designated parking spot. This is especially useful when more than one person is regularly using the lift. In another configuration, the Remote Control may be used as an Attendant control. Meaning that someone that is not seated in the chair (a care taker) can control the stairlift. This is especially useful in the case where the chair-user is impaired to operate the joystick themselves. Lastly, the repeater configuration can be used to extend transmissions so that the signal can travel longer distances when the surrounding environment is blocking the signal from the Remote Control to the chair. 1. Call & Park control 2. Attendant control 3. Wall mounting plate 4. Repeater 1 Note the Remote Control is identified with Manufacturing part number M/N 1131444, the UI-Joystick with M/N 1131445 and a complete stairlift with RP00-CU. TK Home Solutions B.V. User’s manual Remote Control and UI-Joystick part Reference: 003 – RP00-CU user’s manual partially page 5 of 11 Version: A.1 State: Released 2 Remote Control 2.1 Power As mentioned, there are three possible configurations for the Remote Control. The “Call & Park” and “Attendant” configurations are typically powered by four AAA batteries. Remove the battery cover on the back of the Remote Control and replace the batteries when they are empty. The “Repeater” configuration will typically be mounted to a wall on an intermediate floor. For continuous operation the Repeater is supplied by an external power supply. In order to use the Call & Park with repeater during black out, batteries could still be placed. In normal operation the USB power adapter (model: VER05US50-UB, 5V @1000mA) is used to supply the USB power to the remote. The unit automatically switches in case of blackout to batteries. When both the batteries and cable are present, close the back of the Remote Control battery cover and place the unit in the Wall mount plate. TK Home Solutions B.V. User’s manual Remote Control and UI-Joystick part Reference: 003 – RP00-CU user’s manual partially page 6 of 11 Version: A.1 State: Released The required wall plug is depending on the country, several adapters can easily be placed into the power supply. All adapters plugs are included for Europe, the UK, the US and…

Text truncated - open the document above for the full version.

Cover Letter(s)

TÜV Rheinland Nederland B.V. Head office Arnhem: Locations in The Netherlands: TÜV Rheinland Nederland B.V. is a registered company at the Dutch Chamber of Commerce under number 27288788 [email protected] www.tuv.com/nl The Netherlands Tel. +31 (0)88 888 7 888 Fax +31 (0)88 888 7 879 Eiberkamp 10 P.O. Box 37 9350 AA Leek Fax:+31 594 504804 Version: 20101101 ® TÜV, TUEV a nd TUV are registered trademarks . Any use or application requires prior approval. TUV Rheinland of North America, Inc. 1279 Quarry Lane, Suite A Pleasanton, CA 94566 USA On behalf of our customer TK Home Solutions B.V., we hereby would like to apply for an Original certification for the following device: FCC ID ZAH-1131445 IC 27285-1131445 Brand TK Home Solutions B.V. HVIN, Model 1131445 Description Remote system for calling and sending a chair lift The following PDF files (exhibits) are electronically submitted: 1. Cover letter (this document) 2. Request or confidentiality 3. Authorization letter 4. Form 731 5. Antenna information 6. Bill of material (BOM)- Not required-Not provided 7. Block diagram 8. Circuit diagram 9. Interior photographs 10. Exterior photographs 11. Label information 12. Operational description 13. Test report 14. Test setup photographs 15. User/installation manual 16. RF Exposure Best regards, TÜV Rheinland Nederland B.V. R .van der Meer Test Engineer

Cover Letter(s)

2/2 Request for Confidentiality Date: June 22, 2021 Subject: Confidentiality Request for FCC ID : ZAH-1131444 and FCC ID ZAH-1131445 IC: 27285-1131444 and IC: 27285-1131445 Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 9.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term X Permanent Block Diagrams X Short Term External Photos X Short Term Permanent Internal Photos Short Term X Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term X Permanent Schematics X Short Term Test Setup Photos X Short Term Permanent User’s Manual TK Home Solutions B.V. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland Nederland B.V. in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: IC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not considered applicable to IC applications. Sincerely, By: Maarten Verkiel (Signature/Title3 ) (Print name)

Cover Letter(s)

TK HOME SOLUTIONS B.V., VAN UTRECHTWEG 99, 2921 LN KRIMPEN AAN DEN IJSSEL, THE NETHERLANDS P: +31 180 530 900, | [email protected] | [email protected] | www.tkelevator.com BNP PARIBAS SA, NETHERLANDS BRANCH, IBAN: NL82BNPA0227687647, BIC: BNPANL2A HANDELSREGISTER K.V.K. ROTTERDAM NR. 24324608, BTW-IDENTIFICATIENUMMER: NL8100.53.950.B01 1/2 Authority to Act as Agent Date : June 22, 2021 To: TUV Rheinland of North America, Inc. 1279 Quarry Ln., Ste. A Pleasanton, CA 94566 Subject : FCC Agent Authorization Letter for FCC ID: ZAH-1131444 and FCC ID: ZAH-1131445 IC: 27285-113144, and IC: 27285-1131445 To whom it may concern: We, the undersigned, hereby authorize Richard van der Meer of TÜV Rheinland Nederland B.V to act as our agent in the preparation of this application for equipment certification. We certify that submitted documents properly describe the device or system for which equipment certification is sought. We also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Nederland B.V., still resides with the undersigned. We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Agency agreement expiration date: 31-12-2021. Sincerely, Signed by: Maarten Verkiel Title : Maarten Verkiel, Managing Director TK Home Solutions B.V. On behalf of Company Name : TK Home Solutions B.V. Telephone : +31 180 530 900 E-mail : [email protected] TK Home Solutions B.V. Elevator GmbH | Van Utrechtweg 99 2921LN Krimpen aan den IJssel Maarten Verkiel T +316051193215 [email protected] 22 June 2021

External Photos

© TK Home Solutions B.V. page 1 of 1 Photo UI-Joystick unit mounted in armrest FCC ID: ZAH-1131445 IC: 27285-1131445 Photo 1: UI-Joystick module mounted in right armrest, joystick in upright position Photo 2: UI-Joystick module mounted in left armrest, joystick in upright position Photo 3: Side view of UI-Joystick module mounted in armrest, joystick folded down, unusable position (park/boarding position) Photo 4: Front view of UI-Joystick module mounted in armrest, joystick folded down, unusable position (park/boarding position)

ID Label/Location Info

The compliance statement is placed in the User manual as it is regarded as not practical to be placed on the product. Label info

Internal Photos

© TK Home Solutions B.V. page 1 of 1 Photo UI-Joystick hardware PCBA module. FCC ID: ZAH-1131445 IC: 27285-1131445 Photo 1: UI-Joystick PCBA Top view Photo 2: UI-Joystick PCBA Bottom view Photo 3: UI-Joystick module Bottom view, including location of label Photo 4: UI-Joystick module Top view Photo 5: UI-Joystick module side right Photo 6: UI-Joystick module side left

Test Report

Produkte FCC ID: ZAH-1131445 Products IC: 27285-1131445 Prufbericht-Nr: Test report No: 20102801.r03 Seite 1 von 39 Page 1 of 39 Prüfbericht-Nr.: Test Report No.: 20102801.r03 Auftrags-Nr.: Order No.: 89004860 890026 32 890026 32 Kunden-Referenz-Nr.: Client Reference No.: 1018247 Auftragsdatum: Order date: 2020-11-18 Auftraggeber: Client: TK Home Solutions B.V. Van Utrechtweg 99, 2921LN Krimpen ad IJssel Netherlands Prüfgegenstand: Test item: UI-Joystick stairlift Bezeichnung / Typ-Nr.: Identification / Type No.: 1131445 Auftrags-Inhalt: Order content: Compliance with standard Prüfgrundlage: Test specification: FCC 47 CFR Part 15, Subpart C, Section 15.247 KDB 558074 D0115.247 Meas Guidance v05r02, April 2, 2019 RSS-Gen Issue 5, Amendment 2, February 2021 RSS-247 (Issue 2, February 2017) ANSI C63.10-2013 Wareneingangsdatum: Date of receipt: 2021-02-10 Prüfmuster-Nr.: Test sample No.: S14463-C2A Prüfzeitraum: Testing period: 2021-03-10 – 2021-05-12 Ort der Prüfung: Place of testing: Leek Prüflaboratorium: Testing laboratory: TÜV Rheinland Nederland B.V. Leek Laboratory Prüfergebnis*: Test result*: PASS geprüft von / tested by: Kontrolliert von / reviewed by: 2021-07-13 Richard van der Meer, Expert 2021-07-13 Sajid Mohammed, Reviewer Datum Date Name / Stellung Name / Position Unterschrift Signature Datum Date Name / Stellung Name / Position Unterschrift Signature Sonstiges / Other: firmware version 9.14 ; hardware version: 05 Zustand des Prüfgegenstandes be Anlieferung: Condition of the test item at delivery:2 Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: Legend: 1 = sehr gut P(ass) = entspricht o.g. 1 = very good P(ass) = passed a.m. 2 = gut Prüfgrundlage(n) 2 = good Test specification(s) 3 = befriedigend F(ail) = entspricht nicht o.g. Prüfgrundlage(n) 3 = satisfactory F(ail) a.m. test specification(s) 4 = ausreichend N/A = nicht anwendbar 4 = sufficient N/A = not applicable 5 = mangelhaft N/T/ = nicht getested 5 = poor N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwending eines Prüfzeichens. This test report only relates to the a.m. testsample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This report does not entitle to carry any test mark TÜV Rheinland Nederland B.V. . Eiberkamp 10 . 9351 VT Leek . Tel: + 31 88 8887888 Mail: [email protected] . Web: www.tuv.com V04 Produkte FCC ID: ZAH-1131445 Products IC: 27285-1131445 Prufbericht-Nr: Test report No: 20102801.r03 Seite 2 von 39 Page 2 of 39 If the place of testing differs from the location given on page 1 this is given under the respective test clause in the report. This test report consists of multiple pages, the number of pages can be seen in the header on the top right of each page. The report ends when the last page is reached. For the influence of the measuring uncertainties on the results, reference is made to the validation of the respective methods. The test results exclusively relate to the tested sample. This report is only to be read is a whole, no sections from this report may be copied. No opinions or interpretation are included in this report. TÜV Rheinland Nederland B.V. is solely responsible for the content. All rights reserved. No part of this report may be reproduced, provided to and/or examined by third parties, and/or published by print, photoprint, microfilm, in electronic form or any other means without the explicit previous written consent of TÜV Rheinland Nederland B.V. In case this report was drafted within the context of an assignment to TÜV Rheinland Nederland B.V., the rights and obligations of contracting parties are subject to the General Terms & Conditions for Advisory, Research and Certification assignments to TÜV Rheinland Nederland B.V. and/or the relevant agreement concluded between the contracting parties. © 2010 TÜV Rheinland Nederland Statements - This document does not represent type approval or certification of the product. - The test results only relate to the behaviour of the test specimens of the examined product under the particular conditions of the test in laboratory conditions. - The validity of this report will expire directly after alterations or modifications of the examined product (combination)(s) and/or the criteria. All underlying Standards under the mentioned Main Standard on page 1 of this report are dated as given in the mentioned Main Standard. Each test result below is marked with: Under accreditation: ☒ Yes ☐ No To confirm tests carried out under ISO 17025: 2017 accreditation. If not tested “Under Accreditation” “No” will be checked and “Yes” will be unchecked. This report contains: ☒ No Subcontracting ☐ Subcontracting. Subcontracted measurements and results are marked with an “*” and subcontracted to qualified subcontractors and descripted under the respective test clause in the report. . Produkte FCC ID: ZAH-1131445 Products IC: 27285-1131445 Prufbericht-Nr: Test report No: 20102801.r03 Seite 3 von 39 Page 3 of 39 Table of contents 1 General. ................................................................................................................................................................. 5 1.1 Applied standards. .......................................................................................................................................... 5 1.2 Disclaimer, description of the EUT ................................................................................................................. 5 1.3 System Details ............................................................................................................................................... 5 2 Test conditions. ...........................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Testing and certification of electronic and electric appliances, systems, installations and telecommunication systems TÜV Rheinland Nederland B.V. Eiberkamp 10 9351VT Leek The Netherlands Internet: www.tuv.com/nl E-mail: [email protected] Page 1 of 6 PHOTOGRAPHS OF THE TESTSETUP OF A BRAND TK Home Solutions B.V., MODEL 1131445 FCC ID: ZAH-1131445 IC: 27285-1131445 FCC ID: ZAH-1131445 IC: 27285-1131445 Page 2 of 6 Table of contents 1 PHOTOGRAPHS OF THE TEST SETUP. ...................................................................................................................... 3 1.1 RADIATED EMISSIONS..................................................................................................................................................... 3 1.1.1 Radiated emissions setup below 1 GHz. ......................................................................................................... 3 1.1.2 Radiated emissions setup above 1 GHz. ......................................................................................................... 4 1.1.3 Radiated emissions setup detail, front and rear side. .................................................................................... 5 1.2 ANTENNA PORT CONDUCTED TESTS ............................................................................................................................ 6 1.2.1 Conducted tests test setup overview ................................................................................................................ 6 FCC ID: ZAH-1131445 IC: 27285-1131445 Page 3 of 6 1 Photographs of the test setup. 1.1 Radiated emissions. 1.1.1 Radiated emissions setup below 1 GHz. FCC ID: ZAH-1131445 IC: 27285-1131445 Page 4 of 6 1.1.2 Radiated emissions setup above 1 GHz. FCC ID: ZAH-1131445 IC: 27285-1131445 Page 5 of 6 1.1.3 Radiated emissions setup detail, front and rear side. FCC ID: ZAH-1131445 IC: 27285-1131445 Page 6 of 6 1.2 Antenna Port Conducted Tests 1.2.1 Conducted tests test setup overview

Contact Information

Applicant

Paul Kasbergen(Sr. R&D Electrical Engineer)
[email protected]31649924505Fax: +31 (0)180 530 996

Technical Contact

TK Home Solutions B.V.Paul Kasbergen
[email protected]+31 180530962

Krimpen aan den IJssel · Netherlands

Test Firm

TUV Rheinland Nederland B.V.Wiebe Boekema
[email protected]31-088-888-7888Fax: 31-653-162-192

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.3 MHz - 927.6 MHz25.00 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter within a device, except in accordance with accepted multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from TK Home Solutions B.V.

Stairlift RP00-CU Remote - FCC ID ZAH-1131444 - TK Home Solutions B.V.
ZAH-1131444

Stairlift RP00-CU Remote

Jul 28, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Low power digital transmission system - FCC ID ZAH-1000915 - TK Home Solutions B.V.
ZAH-1000915

Low power digital transmission system

Apr 26, 2011

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Low power digital transmission system - FCC ID ZAH-1000918 - TK Home Solutions B.V.
ZAH-1000918

Low power digital transmission system

Apr 26, 2011

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Low power digital transmission system - FCC ID ZAH-1000912 - TK Home Solutions B.V.
ZAH-1000912

Low power digital transmission system

Apr 26, 2011

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Low power digital transmission system - FCC ID ZAH-1000921 - TK Home Solutions B.V.
ZAH-1000921

Low power digital transmission system

Apr 26, 2011

Equipment Class