8/20/2026 1 Intelligent proximity alert system •Model no. : PAS-K01-12 • Ultra Wideband based intelligent proximity alert system • CAN bus interface with 12/24V external power • Easy use without a setup • Detecting functions are unaffected by wind, falling rain or snow, fog, humidity, air temperature, or light • Tag operates in warehouses, factories, ports, and construction/mining sites as a safety device • IP65 enclosure withstands harsh environments ● Technical Data Weight Standard Deviation of Detecting Distance Max. Detectable Distance Interface Communication Method 2.9cm (500ms, 20m)20mCAN Bus 2.0BUWB General Specifications Data Rate Conducted Tx Power Density Conducted Rx SensitivityMethod 6.8Mbps Max -41.3dBm/MHz -93dBm /500MHz (6.8Mbps, PER 1%) UWB compliant IEEE802.15.4-2011 STD Ultra Wideband RF Parameter Power ConsumptionOperating VoltagePower (Adaptor) Below 4WDC 12V or 24V INPUT : 100 – 230VAC 50-60Hz 1.2A OUTPUT : 12VDC 2.5A Electrical Characteristic Connector Ingress Protection Rating Storage Temperature Operating Temperature I.P Connector PLUG 6P (M10xP0.5) IP65-40~85°C-30~85°C Operating Specifications Intelligent proximity alert system ● Overview IPAS - Silent tag creates a mute environment within a certain zone. Once the silence tag detects a pedestrian tag within the preconfigured range, any pedestrian tag will not be acted by surrounding devices and eventually become silent. Then, the pedestrian tag will re-alert once leaving the zone. The safety zone feature is widely used in small ones inside the warehouse and employees’ lounges. Figure 1. IPAS Silent Tag •Configuration : By IPAS Update Tool S/W Figure 2. IPAS Silent Tag Detecting Distances Safety Area Maximum Distance Minimum Distance AreaTag 20m2m ASilent Tag Configuration The distance can be calibrated by using IPAS update toolkit software. Figure 3. IPAS Silent Tag setting 8/20/2026 3 Intelligent proximity alert system ●Specifications Figure 4. IPAS Silent Tag Detecting Dimension Wire Description FunctionPin No. ColorSize Red AWG #26 +12VP01 YellowCAN_LP02 BlueCAN_HP03 WhiteRS232_TXP04 GreenRS232_RXP05 BlackGNDP06 Dimension Connector Specifications ● Products Assembly Standard Silent TagCigar JackAC Adapter Extension Cable 8/20/2026 4 Intelligent proximity alert system ● Accessory IPAS Extension Cable(6M) IPAS Cable / Cigar Jack Adapter (250V 5A Fuse Included) Products IPAS Universal AC Adapter ● Certifications FCC: ZE8-PAS-K01-12-B R-R-KWO-PAS-K01-12-B Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. "This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.“ The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. A minimum separation distance of 20cm must be maintained between the antenna and the person for this appliance to satisfy the RF exposure requirements. Operation on board an aircraft or a satellite is prohibited. Devices operating under this section may not be employed for the operation of toys. Except for operation onboard a ship or a terrestrial transportation vehicle, the use of a fixed outdoor infrastructure is prohibited. 8/20/2026 5 Intelligent proximity alert system CAUTION : Make No Modification to this Product Any modifications to this product not expressly approved by Kyungwoo Systech could void the user’s authority to operate the product. Contact Kyungwoo Systech for more information. Kyungwoo Systech, Inc. Limited Warranty Kyungwoo Systech, Inc. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Kyungwoo Systech, Inc. will repair or replace, free of charge, any replace, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of KIGIS product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Kyungwoo Systech, Inc., replacement.IN NO EVENT KYUNGWOO SYSTECH INC. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Kyungwoo Systech, Inc. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Kyungwoo Systech, Inc. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identifi…
Text truncated - open the document above for the full version.
Rev 1/26/2023 #401, Daeryung Post Tower 5, 68, Digital- ro 9, Geumcheon-gu, Seoul South Korea Tel No : +82-70-5102-0199 Fax No : - Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-07-30 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: ZE8-PAS-K01-12-B KYUNGWOO SYSTECH INC. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. KYUNGWOO SYSTECH INC. certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, CHANG, YONG JUN / CEO KYUNGWOO SYSTECH INC. Rev 1/26/2023 #401, Daeryung Post Tower 5, 68, Digital- ro 9, Geumcheon-gu, Seoul South Korea Tel No : +82-70-5102-0199 Fax No : - Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-07-30 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: ZE8-PAS-K01-12-B KYUNGWOO SYSTECH INC. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, CHANG, YONG JUN / CEO KYUNGWOO SYSTECH INC.
#401, Daeryung Post Tower 5, 68, Digital-ro 9, Geumcheon-gu, Seoul South Korea Tel No : +82-70-5102-0199 Fax No : - Special Power of Attorney Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Attn: OET Dept. Product/ Model Number: Intelligent Proximity Alert System / PAS-K01-12 I, CHANG, YONG JUN of KYUNGWOO SYSTECH INC. hereby appoint Ryan Kim of CTK Co., Ltd. to represent me to act on my behalf to do any and all of the following : Sign on my behalf the agency, anti-drug and confidentiality cover letters and apply to FCC for the products. The right, powers and authority in fact to exercise any and all of the rights and powers herein granted shell commence and be in full force from 2026/07/15 and continue to 2027/07/15 effective unless specifically terminated by either party. This authorization is limited to the product of as following: FCC ID: ZE8-PAS-K01-12-B Date 2026/07/30 Sincerely,. CHANG, YONG JUN / CEO KYUNGWOO SYSTECH INC.
#401, Daeryung Post Tower 5, 68, Digital-ro 9, Geumcheon-gu, Seoul South Korea Tel No : +82-70-5102-0199 Fax No : - Rev 11/20/07 Federal Communications Commission Authorization and Evaluation Division Date : 2026/07/30 Confidentiality Request regarding application for certification of FCC ID : ZE8-PAS-K01-12-B Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram Schematics Schematics_PCB Layout Parts List Operational Description Block Diagram.pdf Schematics.pdf Schematics_PCB Layout.pdf Part List.pdf Operational Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, CHANG, YONG JUN / CEO KYUNGWOO SYSTECH INC.
CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-1551-9871 Fax: +82-31-624-9501 www.elementkorea.kr EUT External Photographs CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-1551-9871 Fax: +82-31-624-9501 www.elementkorea.kr CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-1551-9871 Fax: +82-31-624-9501 www.elementkorea.kr Accessories
CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-1551-9871 Fax: +82-31-624-9501 www.elementkorea.kr Label Photo
CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-1551-9871 Fax: +82-31-624-9501 www.elementkorea.kr EUT Internal Photographs CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-1551-9871 Fax: +82-31-624-9501 www.elementkorea.kr CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-1551-9871 Fax: +82-31-624-9501 www.elementkorea.kr CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-1551-9871 Fax: +82-31-624-9501 www.elementkorea.kr Antenna
CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 17142, Korea Tel: +82-1511-9871 Fax: +82-31-624-9501 www.elementkorea.kr Page 1 of 1 RF EXPOSURE EVALUATION FCC ID : ZE8-PAS-K01-12-B Standard Requirement [Limit §1.1310(d)(3) & KDB 447498] At operating frequencies above 6 GHz, the MPE limits listed in Table 1 in paragraph (e)(1) of this section shall be used in all cases to evaluate the environmental impact of human exposure to RF radiation as specified in § 1.1307(b)* of this part. *§ 1.1307(b)(1) Determine that they qualify for an exemption pursuant to § 1.1307(b)(3) Table 1 to §1.1310(e)(1) - Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *100 ≤6 3.0-30 1842/f 4.89/f *900/f 2 <6 30-300 61.4 0.163 1.0 <6 300-1,500 f/300 <6 1,500-100,000 5 <6 (B) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) <30 1.34-30 824/f 2.19/f *(180/f 2 ) <30 30-300 27.5 0.073 0.2 <30 300-1,500 f/1500 <30 1,500-100,000 1.0 <30 f = frequency in MHz * = Plane-wave equivalent power density [Determination of exemption §1.1307(b)(3) & KDB 447498] For single RF sources (i.e., any single fixed RF source, mobile device, or portable device A single RF source is exempt if: The available maximum time-averaged power is no more than 1 mW, regardless of separation distance. Results Measured peak power E.I.R.P [dBm] Duty cycle factor [dB] Tune-up Tolerance [dB] *maximum time- averaged power [dBm] maximum time- averaged power [mW] Limit [mW] -25.9 0.96 0.05 -24.89 0.0032 1 *maximum time-averaged power [dBm] = Measured peak power E.I.R.P [dBm] + Tune-up Tolerance + Duty cycle factor *This value was calculated assuming a worst-case scenario with a 100% duty cycle. Under actual operating iconditions, applying the real duty cycle will yield a value significantly lower than the presented result. Conclusion This confirms compliance to the required Radio frequency radiation exposure limit. -END-
TEST REPORT CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin- si, Gyeonggi-do, 17142, Korea Tel: +82-1511-9871 Fax: +82-31-624-9501 REPORT No.: CTK-2026-02121 Page (1) / (25) Pages [EL-CTA-OP-X-KR-F-YS1506] Ver.06 Project Number: CTK-R-2026-02485 Verify the authenticity of this document using Blockchain Click the QR code or visit www.blockchain-verified.com 1. Applicant ◦ Name : KYUNGWOO SYSTEC INC. ◦ Address : #401, Daeryung Post Tower 5, 68, Digital-ro 9,Geumcheon-gu, Seoul, South Korea ◦ Date of Receipt : 2026-05-18 2. Manufacturer ◦ Name : KYUNGWOO SYSTEC INC. 3. Use of Report : For FCC Certification 4. Test sample / Model : Intelligent Proximity Alert System / PAS-K01-12 5. Date(s) of test : 2026-07-15 to 2026-07-31 6. Test Standard (Method) used : FCC 47 CFR part 15 subpart C 15.250 7. Testing Environment : refer to 6 page 8. Test Results : refer to 6 page 9. Location of Test : Permanent Testing Lab On Site Testing (Address : 5, Dongbu-ro 221beon-gil, Cheoin-gu, Yongin-si, Gyeonggi-do, Republic of Korea) The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This report cannot be reproduced or copied without the written consent of CTK. Approval Tested by: (Signature) GWANYONG KIM Technical Manager: (Signature) Young-taek Lee 2026-07-31 CTK Co., Ltd. CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin- si, Gyeonggi-do, 17142, Korea Tel: +82-1511-9871 Fax: +82-31-624-9501 REPORT No.: CTK-2026-02121 Page (2) / (25) Pages [EL-CTA-OP-X-KR-F-YS1506] Ver.06 Project Number: CTK-R-2026-02485 REPORT REVISION HISTORY Date Revision Page No 2026-07-31 Issued (CTK-2026-02121) All This report shall not be reproduced except in full, without the written approval of CTK Co., Ltd. This document may be altered or revised by CTK Co., Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by CTK Co., Ltd. will constitute fraud and shall nullify the document. CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin- si, Gyeonggi-do, 17142, Korea Tel: +82-1511-9871 Fax: +82-31-624-9501 REPORT No.: CTK-2026-02121 Page (3) / (25) Pages [EL-CTA-OP-X-KR-F-YS1506] Ver.06 Project Number: CTK-R-2026-02485 TABLE OF CONTENTS 1. General Information ....................................................................................................... 4 1.1 Applicant Information ............................................................................................... 4 1.2 Product Information ................................................................................................ 4 1.3 Peripheral Devices ................................................................................................. 4 2. Accreditations .............................................................................................................. 5 2.1 Laboratory Accreditations and Listings .......................................................................... 5 2.2 Calibration Details of Equipment Used for Measurement .................................................... 5 3. Test Specifications ......................................................................................................... 6 3.1 Standards ............................................................................................................ 6 3.2 Testing Environment ............................................................................................... 6 3.3 Mode of operation during the test ................................................................................ 7 3.4 Measurement Uncertainty ......................................................................................... 7 3.5 Test Software ........................................................................................................ 7 4. Conformance requirements .............................................................................................. 8 4.1 -10 dB bandwidth ................................................................................................... 8 4.2 Radiated emission ................................................................................................ 10 4.3 AC Conducted Emissions ....................................................................................... 23 APPENDIX A - Test Equipment Used For Tests ....................................................................... 25 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin- si, Gyeonggi-do, 17142, Korea Tel: +82-1511-9871 Fax: +82-31-624-9501 REPORT No.: CTK-2026-02121 Page (4) / (25) Pages [EL-CTA-OP-X-KR-F-YS1506] Ver.06 Project Number: CTK-R-2026-02485 1. General Information 1.1 Applicant Information Company KYUNGWOO SYSTECH INC. Contact Point #401, Daeryung Post Tower 5, 68, Digital-ro 9,Geumcheon-gu, Seoul, South Korea Contact Person Name : Yong-jun Chang E-mail : [email protected] Tel : +82-70-5102-0199 Fax : +82-02-985-8087 1.2 Product Information Product Description Intelligent Proximity Alert System FCC ID ZE8-PAS-K01-12-B Basic Model name PAS-K01-12 Variant Model name - Operating Frequency 6 489.6 MHz Number of channels 1 (Ch : 5) Type of Modulation BPM-BPSK Antenna type PCB Antenna Antenna gain 2.09 dBi Power Source DC (12, 24) V (External Power Supply) Test Software (firmware) 6.2.0.0 Hardware Rev D 1.3 Peripheral Devices Device Manufacturer Model No. Serial No. Note Computer HP 15-bs563TU CND7253R6N AC/DC Adapter HP HSTNN-CA40 7628011101 IPAS EXTENSION - 1-7020-30002 3725 AC ADAPTER - YHY-12002500 DS120030T-W CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin- si, Gyeonggi-do, 17142, Korea Tel: +82-1511-9871 Fax: +82-31-624-9501 REPORT No.: CTK-2026-02121 Page (5) / (25) Pages [EL-CTA-OP-X-KR-F-YS1506] Ver.06 Project Number: CTK-R-2026-02485 2. Accreditations 2.1 Laboratory Accreditations and Listings Country Agency Registration Number USA FCC 805871 CANADA ISED 8737A CAB ID : KR0025…
Text truncated - open the document above for the full version.
PAS-K01-12 UWBAntenna specification 2018.1.10 1.측정 기관:한국전파진흥협회- RAPA 2.측정 장비: ZNA26, Vector Network Analyzers, Far-field 7m 3.안테나 종류: PCB Pattern Antenna 4.안테나 제작: KYUNGWOO SYSTECH INC. / +82-2-985-8085 LeadtheSafeandSmartWorld 2 PAS-K01 UWB Antenna specification 4. Passive gain measurement LeadtheSafeandSmartWorld 3 PAS-K01-12 UWB Antenna specification E2(Phi=90 ) E1(Phi=0) H(Theta= 90) PwrSum BW[deg] Theta[deg ] Peak[dBi]Avg.[dBi]BW[deg] Theta[deg ] Peak[dBi]Avg.[dBi]BW[deg]Phi[deg]Peak[dBi]Avg.[dBi]Phi[deg] Theta[deg ] Peak[dBi]Avg.[dBi]Eff.[%]Freq.No. 161.89-170-12.69-15.66243.81-105-12.12-13.2987.13345-11.67-14.89170120-11.45-14.443.598001 168.67-175-7.14-10.16999175-7.07-7.8882.86200-7.24-9.99160-105-6.31-9.2411.9210002 49.251700.91-3.06324.11751.36-0.62120.13180-0.84-3.0251801.48-2.0762.1115003 71.26-40-1.62-5.3251.66-10-1.84-4.6761.73205-4.12-7.78175-180-1.15-5.2829.6524004 45.11-45-4.19-9.3620.08175-8.63-11.5557.7305-5.55-9.3485-45-4.18-9.5611.0730005 34.281301.2-2.8143.02351.44-1.7633.51603.76-1.8660853.96-1.4371.9539946 36.28-150-2.2-5.3344.12-502.01-2.0146.461200.62-3.975-502.04-3.0649.3844937 48.1250.77-4.1868.1353.01-0.6141.81601.37-3.550353.01-2.3458.3548008 20.64-160-5.6-10.1527.5720-5.16-9.2140.3335-2.8-7.914095-2.65-8.5413.9959909 213.29-160-5.43-10.0727.0920-5.02-9.1640.5335-2.68-7.834085-2.54-8.4814.19600010 211.25-160-2.52-7.7633.57150-2.1-3.9941.62301.89-3.8535852.09-3.9939.89649011 23.74145-4.52-8.4942.73140-3.44-6.6635.3125-2.78-7.5730120-1.33-6.4922.44698912 27.17-155-0.07-4.5655.79145-0.37-2.9831.5270-1.17-6.371301202.22-3.3346.46748813 23.51135-4.11-9.9131.92140-5.49-10.1821.64130-3.51-10.24125115-3.42-912.6798714 28.72125-2.57-6.7222.17145-2.09-7.1429.031302.36-3.56130952.46-4.5634.96848615 19.761250.14-5.8636.63-1000.71-3.2316.06704.580.1870904.58-2.4856.471020016 23.56135-2.45-9.1642.6685-0.32-4.9246.9715-0.05-4.270850.42-5.8226.181100017 23.8855-1.23-7.4154.96801.7-2.7434.8251.25-40801.7-5.2529.881297918 13.29751.19-6.4935.81-105-1.08-5.959.25302.62-2.930902.62-5.130.921700019
CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 17142, Korea Tel: +82-1551-9871 Fax: +82-31-624-9501 www.elementkorea.kr Page (1) / (3) Pages Test Setup Photo Radiated Emissions 9 kHz to 30 MHz 30 MHz to 1 GHz CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 17142, Korea Tel: +82-1551-9871 Fax: +82-31-624-9501 www.elementkorea.kr Page (2) / (3) Pages 1 GHz to 18 GHz 18 GHz to 40 GHz CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 17142, Korea Tel: +82-1551-9871 Fax: +82-31-624-9501 www.elementkorea.kr Page (3) / (3) Pages -10 dB bandwidth AC Power line Conducted Emissions
8011 34th Ave South, Suite 342 · Bloomington, Minnesota, 55425 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15F | 6.49 GHz - 6.49 GHz | - |
Intelligent Proximity Alert System
Equipment Class
WBT - Wideband Transmitter
Intelligent Proximity Alert System
Equipment Class
WBT - Wideband Transmitter
Intelligent Proximity Alert System
Equipment Class
WBT - Wideband Transmitter
Intelligent Proximity Alert System
Equipment Class
WBT - Wideband Transmitter
Intelligent Proximity Alert System
Equipment Class
WBT - Wideband Transmitter