ZG2-GJDXXXXOutdoor Dual PIR Detector

GJD Manufacturing Limited
Outdoor Dual PIR Detector - FCC ID ZG2-GJDXXXX - GJD Manufacturing Limited
Click to zoom

Application Details

Equipment Class
FDS - Part 15 Field Disturbance Sensor
Date of Grant
Apr 25, 2011
Application Purpose
Original Equipment
Date of Application
Apr 25, 2011
Equipment Note
Outdoor Dual PIR Detector
Frequency Range
10525.00000000 - 10525.00000000
Company
GJD Manufacturing Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

P/N 1069154 • REV 4.0 • ISS 03DEC10 1 / 40 DDI602 Outdoor Dual PIR Detector Installation Sheet EN DE ES FR IT NL PL PT SV 1 2 3 4 5 6 2 / 40 P/N 1069154 • REV 4.0 • ISS 03DEC10 7 8 9 10 11 12 13 14 P/N 1069154 • REV 4.0 • ISS 03DEC10 3 / 40 15 16 17 18 © 2010 UTC Fire & Security. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are under license to UTC Fire & Security, 9 Farm Springs Road, Farmington, CT 06034-4065 EN: Installation Sheet Package The package contains: • 1 x DDI602 • 1 x drilling template for fixing holes • 1 x hex wrench • 2 x 31.75 mm / 1.25 in. wall plugs • 2 x 31.75 mm / 1.25 in. screws • 1 x lens mask • 2 x additional curtain shutters • 1 x tamper cup • 2 x tamper caps (different lengths) • 1 x plastic locking tool • 1 x installation sheet • 1 x front cover screw cap Introduction The DDI602 Outdoor Dual PIR Detector is an outdoor motion detector and alarm trigger that uses two independent passive infrared detectors plus a microwave sensor module. All three sensors must trigger to cause the detector to signal an alarm. The DDI602 uses triple detection technology to 4 / 40 P/N 1069154 • REV 4.0 • ISS 03DEC10 deliver precise, reliable presence detection. It is designed for use in CCTV and intruder alarm systems. Programmable options include a variable pulse count and a choice of three detection ranges: 10 m / 33 ft., 20 m / 66 ft., and 30 m / 98 ft. The integral dual-axis tilt sensor allows 180° of pan and 90° of tilt. This increases the speed of the outdoor installation and provides incredibly accurate aiming of the detection pattern. The electronics module is acrylic coated for additional component stability. It is encased in a vandal-resistant, high- impact, UV stabilized plastic housing with an opaque polyethylene front cover ensuring that the sensor is impervious to and unaffected by weather conditions. The combination of precision electronics, digital white light filtering, and double shielding eliminates false alarms from the sun and other visible light sources. The DDI602 design has a neat and professional appearance that gives no visible indication of the orientation of the detector head and totally hides the wiring. Quick installation 1. Mount and connect the detector following the instructions given later in this sheet. 2. Apply supply voltage to the unit. The detection LED (blue) flashes three times. 3. Wait approximately 2 to 3 minutes to allow the detector to settle. 4. Press the programming button once to activate walk test mode. The detection LED is now enabled for five minutes. Note: The front cover must be fitted when walk testing. The default settings are: • Range: 30 meters / 98 feet • Pulse count: 1 • Detection LED: off Mounting the unit During installation, protect the electronics against water, as trapped moisture can affect or damage the unit. To mount the detector: 1. Drill the wall to accept the two fixing screws, the cable entry, and the tamper cup (if used). See Figures 1 and 3. A hole-drilling template is provided. Notes • Leave a minimum 10 cm (4 inches) clearance above the top of the detector housing to allow the cover and the detector to be positioned correctly. • We recommend using the tamper cup on uneven wall surfaces. • When mounting the units side by side, a minimum space of 1 m must be left between the detectors and the detectors must not be looking directly towards each other. No minimum space is required when mounting the units back to back. • The recommended optimum mounting height for the detector is 3 m. Whilst it is possible to mount the unit higher, this will give a reduced detection range and will require the detection subject to move further through the already reduced detection area before an activation is signalled. 2. Remove the cover assembly by loosening the locking screw using the hex wrench provided. Squeeze the sides of the front cover to release the internal catches. The cover hinges from the top and lifts out of the location slot. See Figure 2. 3. Use a razor knife to open a rubber seal to allow the cabling into the unit (see Figure 4). Feed standard eight- core alarm cable into the cable entry. Bare the wires and connect to the top PCB terminal block (Figure 5, item 2). 4. Screw the unit to the wall ensuring that the tamper pin is correctly located and that the tamper microswitch is closed. To aid installation, two spare tamper feet are provided. One is 1 mm shorter and the other is 2 mm shorter than the tamper foot originally fitted. The tamper foot is a push fit and can be removed by carefully pulling it from the pin. See Figure 1. 5. When the detector is aligned, connected, and programmed to suit the installation: a. Fit the cover to the detector base. b. Lightly screw the locking screw using the hex wrench. c. Put the top of the locking tool into the small notch on each side of the cover, and then apply slight pressure until the cover locks into the base, as shown in Figure 17. d. Tighten the locking screw. Connecting the unit The DDI602 includes jumpers that let you configure internal end-of-line (EOL) resistor values, when EOL resistors are required. Values are: 1, 2.2, 3.3, 4.7, 5.6, and 6.8 kΩ. Figure 5 shows: 1. EOL resistor jumpers 2. Wiring points Alternatively, you can remove the jumpers and connect a discrete resistor directly to the alarm or tamper outputs, as specified by third-party equipment. Table 1: Connections Terminal Label Description 1, 2 ALARM N/C Alarm relay, normally closed 2, 3 EOL End-of-line resistors 3, 4 TAMPER N/C Tamper relay, normally closed 5, 6 ALARM N/O Alarm relay, normally open 7, 8 +, − 12V DC 12 V power supply P/N 1069154 • REV 4.0 • ISS 03DEC10 5 / 40 Multibeam alignment and masking The multifunction lens fitted to the DDI602 detector produces seven long-range beams and seven medium- to short-range curtain PIR beams. The PIR circuitry detects changes in heat and movement in the beam pattern; therefore items such as trees, shru…

Text truncated - open the document above for the full version.

Cover Letter(s)

2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 1.0 2.0 August – 11 - 2008 SCS-F19: Confidentiality Request Letter Page 1 of 1 Rev 2.0 GJD Manufacturing Limited Unit 2 Birch Industrial Estate, Whittle Lane, Heywood, Lancashire, OL10 2SX, United Kingdom Tel: +44 (0) 1706 363998 Fax: +44 (0) 1706 363991 2011-04-13 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Confidentiality Request regarding application for certification of FCC ID:ZG2-GJDXXXX We hereby request confidential treatment of information accompanying this application as outlined below: - Schematics Diagram - Block Diagram - Operation description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, GJD Manufacturing Limited Unit 2, Birch Industrial Estate Whittle Lane Heywood, OL10 2SX United Kingdom Tel: +44 (0) 1706 363 998 www.gjd.co.uk SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 2.0

External Photos

FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F EXTERNAL PHOTOS OF EUT Fig. 1 Fig. 2 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 1 of 2 FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F Fig. 3 Fig. 4 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 2 of 2

ID Label/Location Info

FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F LABEL AND LOCATION This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 1 of 1 GJD Manufacturing Limited Product name: Outdoor Dual PIR Detector Mode No.: DDI602 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: ZG2-GJDXXXX Label Location

Internal Photos

FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 1 of 5 INTERNAL PHOTOS OF EUT Fig. 1 Fig.2 FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 2 of 5 Fig. 3 Fig. 4 FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 3 of 5 Fig. 5 Fig. 6 FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 4 of 5 Fig. 7 Fig. 8 FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 5 of 5 Fig. 9

Test Report

FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. FCC TEST REPORT On Behalf of GJD Manufacturing Ltd. Outdoor Dual PIR Detector Model No.: DDI602 Prepared for : GJD Manufacturing Ltd. Address : Unit 2, Birch Industrial Estate, Whittle Lane Heywood, OL10 2SX, United Kingdom Prepared by : SHENZHEN LCS CERTIFICATION SERVICES INC. Address : Xingyuan Industrial Park, Tongda Road, Bao’an Blvd., Bao’an District, Shenzhen, Guangdong, China Report Number : LCS1103160095F Date of Test : March 16, 2011 - April 07, 2011, 2011 Date of Report : April 07, 2011 FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 1 of 27 TEST REPORT For FCC ID 47 CFR PART 15, 2010 Report Reference No. ....................: LCS1103160095F Date of issue.....................................: April 07, 2011 Testing Laboratory Name ..............: SHENZHEN LCS CERTIFICATION SERVICES INC. Address.............................................: Xingyuan Industrial Park, Tongda Road, Bao’an Blvd., Bao’an District, Shenzhen, Guangdong, China Testing location/ procedure ..............: Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s name ............................: GJD Manufacturing Ltd. Address.............................................: Unit 2, Birch Industrial Estate, Whittle Lane Heywood, OL10 2SX, United Kingdom Test specification ...........................: Standard ...........................................: 47 CFR PART 15, 2010 , ANSI C63.4-2009 Test Report Form No. ....................: CTSEMC-1.0 TRF Originator ..................................: SHENZHEN LCS CERTIFICATION SERVICES INC. Master TRF.......................................: Dated 2011-03 SHENZHEN LCS CERTIFICATION SERVICES INC. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the SHENZHEN LCS CERTIFICATION SERVICES INC. is acknowledged as copyright owner and source of the material. SHENZHEN LCS CERTIFICATION SERVICES INC.takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .................... : Outdoor Dual PIR Detector Trade Mark .......................................: / Manufacturer ....................................: GJD Manufacturing Ltd. Model/Type reference.......................: DDI602 Ratings..............................................: DC 12V Operating Frequency......................... 10.525GHz Result ................................................ Positive Compiled by: Supervised by: Approved by: BoBo Lee/ File administrators Vito/ Technique principal Gavin Liang / Manager FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 2 of 27 FCC ID -- T E S T R E P O R T Test Report No. : LCS1103160095F April 07, 2011 Date of issue Type / Model............................ DDI602 EUT.......................................... Outdoor Dual PIR Detector Applicant........................... GJD Manufacturing Ltd. Address.................................... Unit 2, Birch Industrial Estate, Whittle Lane Heywood, OL10 2SX, United Kingdom Telephone................................ +44 (0) 1706 363998 Fax........................................... +44 (0) 1706 363991 Contact..................................... Mark Tibbenham Manufacturer...................... GJD Manufacturing Ltd. Address.................................... Unit 2, Birch Industrial Estate, Whittle Lane Heywood, OL10 2SX, United Kingdom Telephone................................ +44 (0) 1706 363998 Fax........................................... +44 (0) 1706 363991 Contact..................................... Mark Tibbenham Factory................ GJD Manufacturing Ltd. Address.................................... Unit 2, Birch Industrial Estate, Whittle Lane Heywood, OL10 2SX, United Kingdom Telephone................................ +44 (0) 1706 363998 Fax........................................... +44 (0) 1706 363991 Contact..................................... Mark Tibbenham Test Result according to the standards on page 3:Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 3 of 27 TABLE OF CONTENTS Description Page 1.TEST STANDARDS........................................................................................................................................4 2.SUMMARY......................................................................................................................................................4 2.2 FINAL ASSESSMENT........................................................................................................................................4 3.EQUIPMENT UNDER TEST ...........................................................................................................................4 3.1 POWER SUPPLY SYSTEM UTILISED..........................................................................................................................4 3.2 SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT)......................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID:ZG2-GJDXXXX SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS1103160095F This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Certification Services Inc. Page 1 of 1 1. PHOTOGRAPH 1.1. Photo of Radiated Measurement Below 1GHz Above 1GHz

Contact Information

Applicant

Mark Tibbenham(Managing Director)
[email protected]+44 (0) 1706 363998Fax: +44 (0) 1706 363991

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedDaniel zhu
[email protected]86-755-26014771

Technical Specifications

#Rule PartsFrequency RangePower Output
115.24510.53 GHz - 10.53 GHz-
Confidentiality
Long Term