www.dragino.com DLOS8 LoRaWAN Gateway User Manual 1 / 47 DLOS8 Outdoor LoRaWAN Gateway User Manual Document Version: 1.0.0 Firmware Version: LG02_LG08--build-v5.4.1590459021-20200526-1012 Version Description Date 1.0 Release 2020-Jun-14 www.dragino.com DLOS8 LoRaWAN Gateway User Manual 2 / 47 Table of Contents 1 Introduction .............................................................................................................................. 5 1.1 What is the DLOS8 ...................................................................................................................... 5 1.2 Specifications .............................................................................................................................. 6 1.3 Features ...................................................................................................................................... 7 1.4 Hardware System Structure........................................................................................................ 8 1.5 DLOS8 Applications..................................................................................................................... 9 1.6 LED Indicators ............................................................................................................................. 9 2 Access and Configure DLOS8 ................................................................................................... 10 2.1 Find IP address of DLOS8 .......................................................................................................... 10 2.1.1 Connect via WiFi ............................................................................................................. 10 2.1.2 Connect via Ethernet with DHCP IP from router ............................................................ 11 2.1.3 Connect via WiFi with DHCP IP from router ................................................................... 11 2.1.4 Connect via Ethernet with fall back ip ............................................................................ 11 2.2 Access Configure Web UI .......................................................................................................... 12 3 Typical Network Setup ............................................................................................................ 13 3.1 Overview .................................................................................................................................. 13 3.2 Use WAN port to access Internet .............................................................................................. 13 3.3 Access the Internet as a WiFi Client. ......................................................................................... 14 3.4 Access the Internet via Cellular ................................................................................................ 14 3.5 Check Internet connection ........................................................................................................ 15 4 Example: Configure as a LoRaWAN gateway ........................................................................... 16 4.1 Create a gateway in TTN Server ............................................................................................... 17 4.2 Configure DLOS8 to connect to TTN ......................................................................................... 19 4.3 Configure frequency ................................................................................................................. 21 4.4 Add a LoRaWAN End Device ..................................................................................................... 22 5 Web Configure Pages .............................................................................................................. 25 5.1 Home ........................................................................................................................................ 25 5.2 LoRa Settings ............................................................................................................................ 26 5.2.1 LoRa --> LoRa .................................................................................................................. 26 5.2.2 LoRa --> ABP Decryption ................................................................................................. 27 www.dragino.com DLOS8 LoRaWAN Gateway User Manual 3 / 47 5.3 LoRaWAN Settings .................................................................................................................... 28 5.3.1 LoRaWAN --> LoRaWAN .................................................................................................. 28 5.3.2 LoRaWAN --> LORIOT ...................................................................................................... 28 5.4 MQTT Settings .......................................................................................................................... 29 5.5 System ...................................................................................................................................... 29 5.5.1 System --> System Overview ........................................................................................... 29 5.5.2 System --> General ( login settings) ................................................................................ 30 5.5.3 System --> Network ........................................................................................................ 31 5.5.4 System --> WiFi ............................................................................................................... 32 5.5.5 System --> Cellular .......................................................................................................... 32 5.5.6 System --> Network Status .............................................................................................. 33 5.5.7 System --> Remote Mgnt ...............β¦
Text truncated - open the document above for the full version.
DATA :11/25/2020 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: ZHZDLOS8 Product Name: LoRaWAN Gateway Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissionβs rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality β for example ...) β’ Schematics β’ Block diagram β’ Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature> Name: edwin chen Title: General manager Company: Dragino Technology Co., Limited.
DATA :11/25/2020 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Global United Technology Services Co., Ltd. Address: No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commissionβs regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Dragino Technology Co., Limited. Address: Room 202,BaoChengTai industrial park,No.8 CaiYun LongCheng Street,LongGang District, Shenzhen 518116, China (Applicant Name and address) <Signature> Name: edwin chen Title: General manager Applicant Company: Dragino Technology Co., Limited.
GTS202010000055 Product Name: LoRaWAN Gateway Test Model No.: DLOS8 External Photos Lora Antenna Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 4 GTS202010000055 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 4 GTS202010000055 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 4 GTS202010000055 ------End------ Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 4
Label &Label location
GTS202010000055 Product Name: LoRaWAN Gateway Test Model No.: DLOS8 Internal Photos WiFi Antenna Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 6 GTS202010000055 GPS Antenna LTE Main Antenna LTE Div Antenna Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 6 GTS202010000055 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 6 GTS202010000055 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 6 GTS202010000055 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 6 GTS202010000055 ------End------ Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 6 of 6
FCC ID: ZHZDLOS8 RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3β3.0 614 1.63 *(100) 6 3.0β30 1842/f 4.89/f *(900/f 2 ) 6 30β300 61.4 0.163 1.0 6 300β1500 f/300 6 1500β100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3β1.34 614 1.63 *(100) 30 1.34β30 824/f 2.19/f *(180/f 2 ) 30 30β300 27.5 0.073 0.2 30 300β1500 f/1500 30 1500β100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation Wireless function Output power to antenna (dBm) Antenna Gain(dBi) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 125KHz Bandwidth 21.650 3.00 146.218 0.05804 0.602 PASS 250KHz Bandwidth 21.548 3.00 142.824 0.05669 0.602 PASS 500KHz Bandwidth 13.931 3.00 24.723 0.00981 0.602 PASS
Global United Technology Services Co., Ltd. Report No.: GTS202010000055F01 1 Cover Page TEST REPORT Applicant: Dragino Technology Co., Limited. Address of Applicant: Room 202,BaoChengTai industrial park,No.8 CaiYun LongCheng Street,LongGang District, Shenzhen 518116, China Manufacturer/Factory : Dragino Technology Co., Limited. Address of Manufacturer/Factory : Room 202,BaoChengTai industrial park,No.8 CaiYun LongCheng Street,LongGang District, Shenzhen 518116, China Equipment Under Test (EUT) Product Name: LoRaWAN Gateway Model No.: DLOS8 Trade Mark: Dragino FCC ID: ZHZDLOS8 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: Oct. 12, 2020 Date of Test: Oct. 12 β Nov. 03, 2020 Date of report issued: Nov. 04, 2020 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 67 Report No.: GTS202010000055F01 2 Version Version No. Date Description 00 Nov. 04, 2020 Original Prepared By: Date: Nov. 04, 2020 Project Engineer Check By: Date: Nov. 04, 2020 Reviewer Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 67 Report No.: GTS202010000055F01 3 Contents Page 1 COVER PAGE .................................................................................................................................... 1 2 VERSION ............................................................................................................................................ 2 3 CONTENTS ........................................................................................................................................ 3 4 TEST SUMMARY ............................................................................................................................... 5 5 GENERAL INFORMATION ................................................................................................................. 6 5.1 GENERAL DESCRIPTION OF EUT ..................................................................................................... 6 5.2 TEST MODE ................................................................................................................................... 9 5.3 DESCRIPTION OF SUPPORT UNITS ................................................................................................... 9 5.4 DEVIATION FROM STANDARDS ......................................................................................................... 9 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................ 9 5.6 TEST FACILITY .............................................................................................................................. 9 5.7 TEST LOCATION ............................................................................................................................ 9 6 TEST INSTRUMENTS LIST ..............................................................................................................10 7 TEST RESULTS AND MEASUREMENT DATA .................................................................................12 7.1 ANTENNA REQUIREMENT ...............................................................................................................12 7.2 CONDUCTED EMISSIONS ...............................................................................................................13 8 TEST ITEMS FOR HYBRID ...............................................................................................................16 8.1 CONDUCTED PEAK OUTPUT POW ER ...............................................................................................16 8.2 20DB EMISSION BANDWIDTH .........................................................................................................19 8.3 CARRIER FREQUENCIES SEPARATION .............................................................................................22 8.4 HOPPING CHANNEL NUMBER .........................................................................................................25 8.5 DW ELL TIME ................................................................................................................................26 8.6 PSEUDORANDOM FREQUENCY HOPPING SEQUENCE.........................................................................30 8.7 BAND EDGE .................................................................................................................................31 8.7.1 Conducted Emission Method ..................................................................................................31 8.7.2 Radiated Emission Method.....................................................................................................34 8.8 SPURIOUS EMISSION .....................................................................................................................36 8.8.1 Conducted Emission Method ..................................................................................................36 8.8.2 Radiated Emission Method.....................................................................................................39 9 TEST ITEMS FOR DTS .....................................................................................................................47 9.1 CONDUCTED PEAK OUTPUT POW ER ...............................................................................................47 9.2 β¦
Text truncated - open the document above for the full version.
GTS202010000055 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 2 Product Name: LoRaWAN Gateway Test Model No.: DLOS8 Test Setup Photo Radiated Emission GTS202010000055 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 2 Conducted Emissions ------End------
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.3 MHz - 927.7 MHz | 146.20 mW |

HELIX NODE
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
LoRaWAN IoT Sensor
Equipment Class
DTS - Digital Transmission System
LoRaWAN Gateway
Equipment Class
DTS - Digital Transmission System
LoRaWAN Tracker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
WTS
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter