FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Micron Electronics LLC./
  3. ZKQ-PT102A

ZKQ-PT102ATracker

Micron Electronics LLC.
Tracker - FCC ID ZKQ-PT102A - Micron Electronics LLC.
Click to zoom

Application Details

Equipment Class
PCT - PCS Licensed Transmitter worn on body
Date of Grant
Mar 23, 2023
Application Purpose
Original Equipment
Date of Application
Mar 22, 2023
Equipment Note
Tracker
Frequency Range
1852.50000000 - 1907.50000000
Company
Micron Electronics LLC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual Revision: 1.00 Document Title Version 1.00 Finale Date Status 22-04-08 Released Document Control ID Contents 1 1 Introduction....................................................................................................................................3 2 Product Overview ..........................................................................................................................3 2.1 Appearance..........................................................................................................................3 2.2 Buttons Description.............................................................................................................3 2.3 LED Description .................................................................................................................4 3 Getting Started ...............................................................................................................................4 3.1 Parts List .............................................................................................................................4 3.2 Battery Charging.................................................................................................................5 3.3 Charging Dock ....................................................................................................................5 3.4 Power on/Power off.............................................................................................................6 4 Frequency.......................................................................................................................................7 5 Trouble shooting and Safety info...................................................................................................7 5.1 Trouble shooting .................................................................................................................7 5.2 Safety info...........................................................................................................................7 2 1 Introduction PT102A is a rescue device with voice function.It works on LTE B2 / B4 / B12 network with superior receiving sensitivity. Based on the embedded wireless tracking protocol, PT102A can communicate with the backend server through LTE network, and transfer emergency reports. 2 Product Overview 2.1 Appearance Figure 1-1 2.2 Buttons Description Button /12PIN Interface Description KEY/interface Description Query How much energy left. TEST Key SOSKEY Press this key to dial a phone number through LTE network Press this key to shut down the device in abnormal condition Reset Key 3 2.3 LED Description To be added Figure 1-2 There are 2LED lights in PT102A device, the description as following. Light Event State Red LED Power on charging Steady light Slow flash Steady light Slow flash Blue LED Power on Network indicate 3 Getting Started 3.1 Parts List Name Picture Remark Rescue device 4 charging Dock charging for the device 3.2 Battery Charging The following items are suggestion for battery charge, please pay more attention.  The red LED of charging Dock will be steady light no matter rescue device is charging or not.  Charging will last about 3 hours. Note: If the Rescue device is firstly used, please make sure the battery is fully charged, which will make the life of battery much longer. 3.3 Charging Dock Charging Dock is a base with an AC Adapter. The charging dock is used for device charging , which can be used for charging at any time ( by end user).. 5 Figure 2-2 3.4 Power on/Power off Figure 2-2 6 Power on:  Press the SOS key at least 3 seconds and release it to power on rescue device. Power off:  Rescue device is auto power off and user can’t turn off the machine by itself. LTE:Band2、Band4、Band12 WIFI:2.4GHz (only support receive function) 433:433.92MHz (only support receive function) GPS:1575.42MHz Note:The WIFI function will be activated and report the MAC addresses once the device is in alerting and scan only support,only support receive function;CMT2300A is used to receive the 433.92mHZ signal from the outside,only support receive function. 5 Trouble shooting and Safety info 5.1 Trouble shooting Trouble Possible Reason APN is wrong. Some APN can not visit the internet directly. Solution Ask the network operator for the right APN. Messages can’t be reported to the backend server by Mobile network. The IP address or port of the backend server is wrong. Make sure the IP address for the backend server is an identified address in the internet. Unable to power off The function of power key Enable the function of power key by ATW. was disabled by AT+GTFKS. AT+GTFKS. Battery can not be charged The battery has not been Using a external power source with 3.6V used for too long time and to 4.2V DC power supply to active the has been locked. battery or apply for after sale help. Please move ATW to a place with open sky. ATW can’t fix GPS The GPS signal is weak. successfully. It is better to let the top surface face to the sky. (The same surface with indication LED) 5.2 Safety info The following items are suggestion for safety use, please pay more attention.  Please do not disassemble the device by yourself. 7 4 Frequency   Please do not put the device on the overheating or too humid place, avoid exposure to direct sunlight. Too high temperature will damage the device or even cause the battery explosion. Please do not use the device on the airplane or near medical equipment. FCC Caution. § 15.19 Labelling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. § 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to ope…

Text truncated - open the document above for the full version.

Attestation Statements

Micron Electronics LLC. CERTIFICATIONS CONCERNING “COVERED” EQUIPMENT Date: 2023-03-21 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 FCC ID: ZKQ-PT102A To Whom It May Concern: As required by section 2.911(d)(5)(i), [Micron Electronics LLC.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. As required by section 2.911(d)(5)(ii), [Micron Electronics LLC.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment. Thank you for your attention to this matter. Sincerely yours, Signature Printed Name: Ping Cheng Company: Micron Electronics LLC. Job Title: VP Email: [email protected] Telephone: +18885383489

Cover Letter(s)

Micron Electronics LLC. LETTER OF AGENCY Date 2023-3-16 Element Materials Technology 100 Frobisher Business Park Malvern Worcestershire WR14 1BX UK FCC ID: ZKQ-PT102A To Whom It May Concern: We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application, is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Yours faithfully company Micron Electronics LLC. Signature Full Name Ping Cheng Job Title:VP Tel No: +18885383489 E-mail: [email protected]

Cover Letter(s)

Micron Electronics LLC. Request for Confidentiality Letter-FCC (This is only an example, the exact contents of the letter should be created, reviewed, and approved by someone in your company who understands the confidential treatment of your competitive information and how the rules listed below effect that.) Date 2023-3-16 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Request for confidentiality FCC ID: ZKQ-PT102A To whom it may concern, We hereby respectfully request that under the provision of 47 CFR 0.459 and 0.457(d) the documents listed below and attached with this application for certification be provided with confidential status. • Schematics.pdf • Operational Description.pdf • Frequency Block Diagrams.pdf • BOM.pdf • Tune up procedure.pdf Any exhibit / information for which we have requested confidentiality, but which may not be accorded such treatment by the FCC, should be returned to us. The documents listed above contain trade secrets that are treated as confidential by us. Substantial competitive harm to us could result should they be made available to the public. Sincerely, Name:Ping Cheng Job Title:VP Tel No: +18885383489 E-mail: [email protected]

External Photos

I23W00004_ExternalPhotos-Rev1 EUTFRONT EUTBACK Side1 Side2 Side3 Side4 base Basedetail

ID Label/Location Info

I23W00004-LabellocationPhotos-Rev1 Labellocation

Internal Photos

I23W00004_InternalPhotos-Rev1 ANT Internal 433ANT GPSANT MAINANT DIVANT WiFiANT BATTERYdetail Batterylabel PCB PCB-front PCBfrontCHIPSdetail PCBBACK CHIPSdetail

Operational Description

Antenna SPEC Customer name:MobiletekProject name:PT102A Operating Band: LTE B2/B4/B12&GPS&WIFI&433 Motherboard version:PT102_V2_221102A Material specifications Specifications and modelsMaterial NoCustomer data Main antenna SH22396IB89 Change your resume Date of establishment/ch ange Change the contentChangersVersion 23.3.21V1.0 SUNNYWAY Will sign the box R & D ME:Audit: QE: Approved: RF:Audit: The customer will sign the bar Electrical engineer PMMEQE Tel:+86-021-64842326 (shanghai) +86-0755-82504258(shenzhen) Fax:+86-021-64842328 Shanghai R & D center: Room 302, building 65, No.421, Hong Cao Road, Caohejing Development Zone, Shanghai. Shenzhen R&D Center: Room 405, 4th Floor, Jinke Building, No.8 Qiongyu Road, Nanshan District, Shenzhen Sunnyway Technology (China) Co., Ltd. 目录 1. Project Image................................................................................... 3 2.Test fixture......................................................................................... 4 3.Matching circuit................................................................................ 4 4.S11 test.................................................................................................... 6 4.1S11 The test method states.................................................................................6 4.2 S11 Parameter....................................................................................................6 4.2V.S.W.R................................................................................................................6 5 Darkroom test data............................................................................... 6 5.1 Passive test data..................................................................................................9 5.1 .1 Passive efficiency of antenna...........................................................................9 5.2 Active test data...........................................................................................12 5.2.2Active antenna test data...................................................................................... 12 6.Ground handling of the prototype..................................................12 7.Mass production antenna index...................................................... 13 8 Engineering drawings.........................................................................13 1. Project information Machine Information Antenna information The final verification antenna performance prototype is kept in our company for at least one year to facilitate the analysis and resolution of antenna production anomalies,Ensure the quality of antenna shipment MotherboardPT102_V2_221102A Sunnyway Technology(china)ltd. Company Antenna Specification Sunnyway Technology(china)ltd. Company Antenna Specification 2.Test fixture Purpose: To test antenna passive parameters as accurately as possible。 methods:the fixture is to use a 50 ohm coaxial cable, one end is connected to the pad after the antenna ‘s matching circuit (the front of the antenna switch) , and the other end is connected to the SMA connector. 3. Matching circuit ElementValue E1N/A E2 0Ω E3N/A ElementValue E1N/A E2 0Ω E3N/A The main antenna Diversity antenna Sunnyway Technology(china)ltd. Company Antenna Specification ElementValue E1N/A E2 0Ω E3N/A ElementValue E1 18nH E2 0Ω E3N/A Wi-fi antenna GPS antenna 433 Antenna ElementValue E1N/A E2 0Ω E3N/A Sunnyway Technology(china)ltd. Company Antenna Specification 4.S11 Test 4.1 S11 test method instructions Test equipment:LNA(E5062A) Test method:With a 50 ohm CABLE ,CABLE export from instrument testing port ,After the calibration with calibration Key, connected to the SMA connector,Records the return loss and VSWR of the related frequency points. Test schematic diagram is as follows: 4.2 S11 Parameter The main antenna FRq(MHz)VSWR 7004.0 7242.03 7486.36 17101.79 19203.23 21708.8 Sunnyway Technology(china)ltd. Company Antenna Specification Diversity antenna FRq(MHz)VSWR 15751.55 FRq(MHz)VSWR 171012.3 19203.79 21705.11 GPS antenna Sunnyway Technology(china)ltd. Company Antenna Specification Wi-fi antenna FRq(MHz)VSWR 4331.58 FRq(MHz)VSWR 24003.1 25003.07 433 Antenna 5. Anechoic Chamber test data test system: SHIELDED ANECHOIC chamber test environment: temperature 22 ° C ± 3 ° C, humidity 50% ± 15% test equipment: when testing passive data, when testing active data using Network analyzer Agilent E5062C, agilent 8960/CMW500/E4438C was used Sunnyway Technology(china)ltd. Company Antenna Specification 5.1 Passive test data Passive efficiency of WIFI antennas The main antenna 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 7 0 0 7 2 0 7 4 0 1 7 1 0 1 7 3 0 1 7 5 0 1 7 7 0 1 7 9 0 1 8 1 0 1 8 3 0 1 8 5 0 1 8 7 0 1 8 9 0 1 9 1 0 1 9 3 0 1 9 5 0 1 9 7 0 1 9 9 0 2 0 1 0 2 0 3 0 2 0 5 0 2 0 7 0 2 0 9 0 2 1 1 0 2 1 3 0 2 1 5 0 2 1 7 0 Effi (%) Freq.(MHz)700-7401710-2170 MinMaxAvgMinMaxAvg Effi(%)13.4515.8814.3922.5139.9632.02 Effi(dB)-8.71-7.99-8.43-6.48-3.98-5.02 Sunnyway Technology(china)ltd. Company Antenna Specification Diversity antenna 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 1 7 1 0 1 7 3 0 1 7 5 0 1 7 7 0 1 7 9 0 1 8 1 0 1 8 3 0 1 8 5 0 1 8 7 0 1 8 9 0 1 9 1 0 1 9 3 0 1 9 5 0 1 9 7 0 1 9 9 0 2 0 1 0 2 0 3 0 2 0 5 0 2 0 7 0 2 0 9 0 2 1 1 0 2 1 3 0 2 1 5 0 2 1 7 0 Effi (%) Freq.(MHz)1710-2170 MinMaxAvg Effi(%)9.9215.512.31 Effi(dB)-10.04-8.01-9.14 GPS antenna 27 27.5 28 28.5 29 29.5 30 156015701580 Effi (%) Freq.(MHz)1560-1580 MinMaxAvg Effi(%)27.8729.5428.58 Effi(dB)-5.55-5.3-5.44 Sunnyway Technology(china)ltd. Company Antenna Specification Freq.(MHz)2400-2500 MinMaxAvg Effi(%)29.1331.8930.67 Effi(dB)-5.36-4.96-5.13 433 Antenna Freq.(MHz)420-440 MinMaxAvg Effi(%)25.1627.8426.19 Effi(dB)-5.99-5.55-5.82 Wi-fi antenna 27.50 28.00 28.50 29.00 29.50 30.00 30.50 31.00 31.50 32.00 32.50 24002410242024302440245024602470248024902500 Effi (%) 23.5 24 24.5 25 25.5 26 26.5 27 27.5 28 420430440 Effi (%) Sunnyway T…

Text truncated - open the document above for the full version.

RF Exposure Info

ReportNo.:I23W00004-SAR-Rev2 ChongqingAcademyofInformationandCommunicationTechnology Address:No.8,YumaRoad,ChayuanNewCity,Nan’anDistrict,Chongqing,P.R.China,401336 Tel:0086-23-88069965FAX:0086-23-88608777 Page 1 of94 TESTREPORT REPORTNUMBER:I23W00004-SAR-Rev2 ON TypeofEquipment:Tracker TypeofDesignation:PT102A BrandName :Prime Manufacturer:MicronElectronicsLLC. FCCID: ZKQ-PT102A ACCORDINGTO IEEEC95.1-2019 IEC/IEEE62209-1528-2020 ChongqingAcademyofInformationandCommunicationTechnology Monthdate,year Mar.22nd,2023 Signature XiangLuoyong Director Note: Thetestresultsinthistestreportrelateonlytothedevicesspecifiedinthisreport.Thisreport shallnotbereproducedexceptinfullwithoutthewrittenapprovalofChongqingAcademyof InformationandCommunicationsTechnology. ReportNo.:I23W00004-SAR-Rev2 ChongqingAcademyofInformationandCommunicationTechnology Address:No.8,YumaRoad,ChayuanNewCity,Nan’anDistrict,Chongqing,P.R.China,401336 Tel:0086-23-88069965FAX:0086-23-88608777 Page 2 of94 RevisionVersion ReportNumberRevisionDateMemo I23W00004-SAR002023-3-15Initialcreationoftestreport I23W00004-SAR-Rev1012023-3-21Firstchangeoftestreport I23W00004-SAR-Rev2022023-3-22Secondchangeoftestreport Note:Thisversionhasincreasedthetunneupdescribeofalltestfrequencybandsfor3Mbandwidthfull RBforQPSKand16QAM,alsoincreasedthetunneupdescribeofLTEB12for1.4Mbandwidth3RB. ReportNo.:I23W00004-SAR-Rev2 ChongqingAcademyofInformationandCommunicationTechnology Address:No.8,YumaRoad,ChayuanNewCity,Nan’anDistrict,Chongqing,P.R.China,401336 Tel:0086-23-88069965FAX:0086-23-88608777 Page 3 of94 TABLEOFCONTENT 1.TESTLABORATORY ..........................................................................................................................................................................5 1.1TESTINGLOCATION..................................................................................................................................................................................5 1.2TESTINGENVIRONMENT ...........................................................................................................................................................................5 1.3PROJECTDATA .........................................................................................................................................................................................5 1.4SIGNATURE...............................................................................................................................................................................................5 2.STATEMENTOFCOMPLIANCE ......................................................................................................................................................6 3.CLIENTINFORMATION....................................................................................................................................................................7 3.1APPLICANTINFORMATION ........................................................................................................................................................................7 3.2MANUFACTURERINFORMATION...............................................................................................................................................................7 4.EQUIPMENTUNDERTEST(EUT)ANDANCILLARYEQUIPMENT(AE)................................................................................8 4.1ABOUTEUT .............................................................................................................................................................................................8 4.2INTERNALIDENTIFICATIONOFEUTUSEDDURINGTHETEST..................................................................................................................9 4.3INTERNALIDENTIFICATIONOFAEUSEDDURINGTHETEST.....................................................................................................................9 5.REFERENCEDOCUMENTS.............................................................................................................................................................10 5.1APPLICABLELIMITREGULATIONS ..........................................................................................................................................................10 5.2APPLICABLEMEASUREMENTSTANDARDS.............................................................................................................................................10 6.SPECIFICABSORPTIONRATE(SAR)............................................................................................................................................11 6.1INTRODUCTION .......................................................................................................................................................................................11 6.2SARDEFINITION....................................................................................................................................................................................11 7.SARMEASUREMENTSETUP..........................................................................................................................................................12 7.1MEASUREMENTSET-UP..........................................................................................................................................................................12 7.2DASY5E-FIELDPROBESYSTEM ...........................................................................................................................................................13 7.3E-FIELDPROBECALIBRATION................................................................................................................................................................14 7.4OTHERTESTEQUIPMENT.................................................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:I23W00004-SAR-Rev2 ChongqingAcademyofInformationandCommunicationTechnology Address:No.8,YumaRoad,ChayuanNewCity,Nan’anDistrict,Chongqing,P.R.China,401336 Tel:0086-23-88069965FAX:0086-23-88608777 Page 1 of94 TESTREPORT REPORTNUMBER:I23W00004-SAR-Rev2 ON TypeofEquipment:Tracker TypeofDesignation:PT102A BrandName :Prime Manufacturer:MicronElectronicsLLC. FCCID: ZKQ-PT102A ACCORDINGTO IEEEC95.1-2019 IEC/IEEE62209-1528-2020 ChongqingAcademyofInformationandCommunicationTechnology Monthdate,year Mar.22nd,2023 Signature XiangLuoyong Director Note: Thetestresultsinthistestreportrelateonlytothedevicesspecifiedinthisreport.Thisreport shallnotbereproducedexceptinfullwithoutthewrittenapprovalofChongqingAcademyof InformationandCommunicationsTechnology. ReportNo.:I23W00004-SAR-Rev2 ChongqingAcademyofInformationandCommunicationTechnology Address:No.8,YumaRoad,ChayuanNewCity,Nan’anDistrict,Chongqing,P.R.China,401336 Tel:0086-23-88069965FAX:0086-23-88608777 Page 2 of94 RevisionVersion ReportNumberRevisionDateMemo I23W00004-SAR002023-3-15Initialcreationoftestreport I23W00004-SAR-Rev1012023-3-21Firstchangeoftestreport I23W00004-SAR-Rev2022023-3-22Secondchangeoftestreport Note:Thisversionhasincreasedthetunneupdescribeofalltestfrequencybandsfor3Mbandwidthfull RBforQPSKand16QAM,alsoincreasedthetunneupdescribeofLTEB12for1.4Mbandwidth3RB. ReportNo.:I23W00004-SAR-Rev2 ChongqingAcademyofInformationandCommunicationTechnology Address:No.8,YumaRoad,ChayuanNewCity,Nan’anDistrict,Chongqing,P.R.China,401336 Tel:0086-23-88069965FAX:0086-23-88608777 Page 3 of94 TABLEOFCONTENT 1.TESTLABORATORY ..........................................................................................................................................................................5 1.1TESTINGLOCATION..................................................................................................................................................................................5 1.2TESTINGENVIRONMENT ...........................................................................................................................................................................5 1.3PROJECTDATA .........................................................................................................................................................................................5 1.4SIGNATURE...............................................................................................................................................................................................5 2.STATEMENTOFCOMPLIANCE ......................................................................................................................................................6 3.CLIENTINFORMATION....................................................................................................................................................................7 3.1APPLICANTINFORMATION ........................................................................................................................................................................7 3.2MANUFACTURERINFORMATION...............................................................................................................................................................7 4.EQUIPMENTUNDERTEST(EUT)ANDANCILLARYEQUIPMENT(AE)................................................................................8 4.1ABOUTEUT .............................................................................................................................................................................................8 4.2INTERNALIDENTIFICATIONOFEUTUSEDDURINGTHETEST..................................................................................................................9 4.3INTERNALIDENTIFICATIONOFAEUSEDDURINGTHETEST.....................................................................................................................9 5.REFERENCEDOCUMENTS.............................................................................................................................................................10 5.1APPLICABLELIMITREGULATIONS ..........................................................................................................................................................10 5.2APPLICABLEMEASUREMENTSTANDARDS.............................................................................................................................................10 6.SPECIFICABSORPTIONRATE(SAR)............................................................................................................................................11 6.1INTRODUCTION .......................................................................................................................................................................................11 6.2SARDEFINITION....................................................................................................................................................................................11 7.SARMEASUREMENTSETUP..........................................................................................................................................................12 7.1MEASUREMENTSET-UP..........................................................................................................................................................................12 7.2DASY5E-FIELDPROBESYSTEM ...........................................................................................................................................................13 7.3E-FIELDPROBECALIBRATION................................................................................................................................................................14 7.4OTHERTESTEQUIPMENT.................................................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

TESTREPORT REPORTNUMBER:I23W00004-LTERF-Rev1 ON TypeofEquipment:tracker TypeofDesignation:PT102A BrandName:Prime Manufacturer:MicronElectronicsLLC. FCCID:ZKQ-PT102A ACCORDINGTO FCCCFRPart2,FREQUENCYALLOCATIONSANDRADIOTREATYMATTERS; GENERALRULESANDREGULATIONS,e-CFR PART24,PersonalCommunicationsServices,e-CFR PART27,MISCELLANEOUSWIRELESSCOMMUNICATIONSSERVICES,e-CFR ANSIC63.26-2015AmericanNationalStandardforComplianceTestingofTransmitters UsedinLicensedRadioServices ChongqingAcademyofInformationandCommunicationsTechnology Monthdate,year Mar,21,2023 Signature XiangLuoyong Director Note: Thetestresultsinthistestreportrelateonlytothedevicesspecifiedinthisreport. Thisreportshallnotbereproducedexceptinfullwithoutthewrittenapprovalof ChongqingAcademyofInformationandCommunicationsTechnology. ReportNo.:I23W00004-LTERF-Rev1 ChongqingAcademyofInformationandCommunicationTechnology Address:No.8,YumaRoad,ChayuanNewCity,Nan’anDistrict,Chongqing,P.R.China,401336 Tel:0086-23-88069965FAX:0086-23-88608777 Page2of227 RevisionVersion ReportNumberRevisionDateMemo I23W00004-LTERF002023-03-15Initialcreationoftestreport I23W00004-LTERF-Rev1Rev12023-03-21-- ReportNo.:I23W00004-LTERF-Rev1 ChongqingAcademyofInformationandCommunicationTechnology Address:No.8,YumaRoad,ChayuanNewCity,Nan’anDistrict,Chongqing,P.R.China,401336 Tel:0086-23-88069965FAX:0086-23-88608777 Page3of227 CONTENTS 1.TestLaboratory..............................................................................................................................................5 1.1.TestingLocation.........................................................................................................................................5 1.2.TestingEnvironment...................................................................................................................................5 1.3.Projectdata.................................................................................................................................................5 1.4.Signature.....................................................................................................................................................5 2.ClientInformation.........................................................................................................................................6 2.1.ApplicantInformation................................................................................................................................6 2.2.ManufacturerInformation..........................................................................................................................6 3.EquipmentunderTest(EUT)andAncillaryEquipment(AE)......................................................................7 3.1.About…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ping Cheng(Director)
[email protected]888-538-3489Fax: 888-538-1805

Test Firm

Chongqing Academy of Information and CommuncationsLi Yan
[email protected]15223305745

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
1124E1.85 GHz - 1.91 GHz36.40 mW4M50W7D2.5 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is ERP for operation below 1 GHz and EIRP for operation above 1 GHz. LTE supports 1.4/3/5/10/15/20 MHz BW modes in Band 2/4, and 1.4/3/5/10 MHz BW modes in Band 12. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 5 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory exposure condition is 1.17 W/kg. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.

Other Applications from Micron Electronics LLC.

Tracker - FCC ID ZKQ-PT102V - Micron Electronics LLC.
ZKQ-PT102V

Tracker

Apr 04, 2024

Equipment Class

JAB - Part 15 Class B Digital Device
Tracker - FCC ID ZKQ-AHALO - Micron Electronics LLC.
ZKQ-AHALO

Tracker

Aug 31, 2023

Equipment Class

JAB - Part 15 Class B Digital Device
WB100 - FCC ID ZKQ-WB100 - Micron Electronics LLC.
ZKQ-WB100

WB100

Aug 23, 2023

Equipment Class

PCT - PCS Licensed Transmitter worn on body
Tracker - FCC ID ZKQ-G601 - Micron Electronics LLC.
ZKQ-G601

Tracker

Jun 26, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Tracker - FCC ID ZKQ-ATP4GA2 - Micron Electronics LLC.
ZKQ-ATP4GA2

Tracker

Jun 26, 2023

Equipment Class

PCB - PCS Licensed Transmitter