ZLLNV-TRUX100Receiver of Wireless Patient Monitoring System

At Box Technology Inc.
Receiver of Wireless Patient Monitoring System - FCC ID ZLLNV-TRUX100 - At Box Technology Inc.
Click to zoom

Application Details

Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Date of Grant
May 25, 2011
Application Purpose
Original Equipment
Date of Application
May 25, 2011
Equipment Note
Receiver of Wireless Patient Monitoring System
Company
At Box Technology Inc.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual V.0.9B 100528T0110203 1 WARNING: This product or device is not intended to provide any medical benefit and has not been evaluated by the Food and Drug Administration. Legal Disclaimer: At Box NurseVue is a wireless patient monitoring system. Use of this product is not intended as a substitute for advice from your physician or other health care professional. This product should not be used by children and is not intended as a substitute for medical treatment, adult care or supervision. Said product is designed as a communication or monitoring product and is not intended as a substitute for any care or treatment. This product is not intended to diagnose, treat, cure or prevent disease and is simply for the purposes stated in the products label and packaging materials. Persons with a pacemaker or other implanted devices should check with their physician or other health care professional to determine whether use of this product may interfere with any such device. If you have a serious medical condition, the use of this device should not replace any competent medical supervision you are currently receiving. Introduction 2 LIMITED WARRANTY 1. AT BOX TECHNOLOGY INC. WARRANTY At Box Technology Inc. warrants said product is free of defects in material and workmanship for a period of one year from the date of original purchase. THIS WARRANTY APPLIES ONLY TO THE ORIGINAL PURCHASER OF THIS PRODUCT. In the event of a defect, At Box Technology Inc. will, at its option, repair or replace the product with no charge to the purchaser for parts or labor. The repaired or replaced product will be warranted for ninety (90) days from the date of return shipment, or for the balance of the original warranty, whichever is longer. 2. PURCHASERS REMEDY THE PURCHASER’S EXCLUSIVE REMEDY UNDER THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY SHALL BE LIMITED TO THE REPAIR OR REPLACE MENT, WITH ANY SUCH REPAIRS UNDER THIS WARRANTY TO BE MADE AT AN AUTHORIZED AT BOX FACILITY OR SERVICE CENTER. 3. LIMITATION OF IMPLIED WARRANTIES Except as set forth in items 1 and 2 above, all other expressed or implied warranties, including those of fitness for any particular purpose or merchantability, are hereby disclaimed. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. 4. EXLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES AT BOX TECHNOLOGY INC. SHALL NOT BE LIABLE TO PURCHASER OR ANY OTHER PERSON FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES WHATSOEVER, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DAMAGES RESULTING FROM DELAY OR LOSS OF USE, LOSS OF OR DAMAGES ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY EVEN IF CAUSED BY NEGLIGENCE OR OTHER FAULT. IN NO EVENT WILL AT BOX TECHNOLOGY INC. BE RESPONSIBLE FOR SUCH DAMAGES, EVEN IF AT BOX TECHNOLOGY INC. HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Some states do not allow the exclusion of incidental or consequential damages so the above limitation or exclusion may not apply to you. 5. MERGER This written warranty is the complete, final and exclusive agreement between At Box Technology Inc. and the purchaser with respect to the quality of performance of the goods and any and all warranties and representations. THIS WARRANTY SETS FORTH ALL OF AT BOX TECHNOLOGY INC.’S RESPONSIBILITES REGARDING THIS PRODUCT. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Introduction 3 Introduction Congratulations and thank you for purchasing NurseVue by At Box Technology! NurseVue by At Box Technology is a wireless patient monitoring solution that is designed to keep nurses and care givers in closer communication with patients. This technology provides significant, positive impacts on the nurses’ and care givers’ productivity and effectiveness. By using NurseVue wireless patient monitoring systems, nurses and care givers can communicate with patients from wherever they are within a facility. More importantly, nurses and care givers can be alerted to emergencies within seconds and can escalate an event notification, if needed. This ability to communicate or forward messages, while allowing nurses to meet the needs of multiple patients without having to walk to each room, increases efficiency and reduces caretakers' stress by eliminating the feeling of being needed in all places at once. NurseVue Wireless Patient Monitoring System consists of sensors, light weight wireless transmitter, a USB receiver, an optional router, and software that runs on a Windows based PC. In a nursing home or hospital environment, NurseVue allows care givers to reduce the time and effort in caring for their patients. At the same time, NurseVue improves patients’ comfort while minimizing medical conditions such as rash, urinary tract infection that may trigger additional complex medical problems. 4 Package Contents Each model of NurseVue has slightly differing package contents. Check the table below to verify that your set is complete. NurseVue Transmitter unit NurseVue Receiver unit (antenna may be disassembled) (Receiver does not need external power adapter) Quick Start Guide Power Adapter (for transmitter & router, receiver does not need external power adapter) 5 System Requirements Minimum Optimal CPU Type Any CPU with SSE2 instruction support. CPU Speed 1.6 GHz 2.0 GHz or faster CPU Cores Single-core Dual-core or better RAM 512MB 1GB or more Operating System Windows 2000, XP SP2, Vista, or Windows 7 Windows XP SP2 Note: To ensure At Box NurseVue software is running properly without interruptions, users are recommended to turn off screen savers, auto software updates that could cause the computer to reboot itself. 6 Hardware Specifications At Box NurseVue system consists of wireless transmitters, a wireless receiver. NurseVue Transmitter NurseVue Receiver Part Number NV-TX100 NV-TRUX100 Product Image (Actual product may be slightly different from the images show…

Text truncated - open the document above for the full version.

Cover Letter(s)

Authorization Letter At Box Technology Inc. 2011-5-23 To whom it may concern: We the undersigned, hereby authorize CTI employees Christy Chen to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by CTI employees Christy Chen on our behalf shall have the same affect as acts of our own. This authorization is valid until further written notice from At Box Technology Inc. Sincerely, Signature: (Tingjun Hu)

Cover Letter(s)

Ersteller: U. Rodemeier Revision: 04 Erstelldatum: 03.08.01 Datum: 11.05.07 Seite 1 von 1 Request for Confidentiality PHOENIX TESTLAB GmbH Date: 2011-05-23 Product Certification Königswinkel 10 D 32825 Blomberg RE: Certification Application FCC ID: ZLLNV-TRUX100 Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: • BOM • Operation Description • Schematics • Block Diagram (XXXXX to be replaced by Schematics, Block Diagram, etc.) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457, disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. Thank you for your attention in this matter. Applicant’s Company: Centre Testing International Corporation address : Bldg. C, Hongwei Industrial Park, Block 70, Bao’an District, Shenzhen, Guangdong, China Signature : Job Title and Dept. :EMC Engineer, EMC Lab

ID Label/Location Info

FCC Label information: Label Location

Test Report

Report No. : EESZD04290009-2 Page 1 of 18 FCC TEST REPORT Product Name : HelloNurse Trade Name : At Box Model Name : NV-TRUX100 FCC ID : ZLLNV-TRUX100 Contains FCC ID (ZigBee module) : TYOJN5148M3 Serial Number : N/A Technical Data : 5V/ 600mA, 3W Report Number : EESZD04290009-2 Date : May 23, 2011 Regulations : See below Test Standards Results FCC Part 15 Subpart B: 2009 PASS Prepared for: At Box Technology Inc. 2F. -3, No. 716, JhongJheng Rd., JhengHe Dist., New Taipei City, Taiwan Prepared by : CENTRE TESTING INTERNATIONAL (SHENZHEN) CORPORATION Building C, Hongwei Industrial Zone, Baoan 70 District, Shenzhen, Guangdong, China TEL: +86-755-3368 3362 FAX: +86-755-3368 3385 Check No.: 12711182 This report shall not be reproduced, except in full, without the written approval of CENTRE TESTING INTERNATIONAL (SHENZHEN) CORPORATION Report No. : EESZD04290009-2 Page 2 of 18 TABLE OF CONTENTS Description Page 1. GENERAL INFORMATION ..........................................................................................3 2. TEST SUMMARY .........................................................................................................4 3. MEASUREMENT UNCERTAINTY ...............................................................................4 4. PRODUCT INFORMATION AND TEST SETUP ..........................................................4 4.1. PRODUCT INFORMATION..................................................................................4 4.2. TEST SETUP CONFIGURATION..........................................................................4 4.3. SUPPORT EQUIPMENT.......................................................................................4 5. FACILITIES AND ACCREDITATIONS ........................................................................5 5.1. TEST FACILITY....................................................................................................5 5.2. TEST EQUIPMENT LIST.......................................................................................5 5.3. LABORATORY ACCREDITATIONS AND LISTINGS...........................................5 6. CONDUCTED EMISSION TEST ..................................................................................6 6.1. LIMITS...................................................................................................................6 6.2. BLOCK DIAGRAM OF TEST SETUP...................................................................6 6.3. PROCEDURE OF CONDUCTED EMISSION TEST.............................................6 6.4. GRAPHS AND DATA...........................................................................................7 7. RADIATED EMISSION TEST ......................................................................................9 7.1. LIMITS...................................................................................................................9 7.2. BLOCK DIAGRAM OF TEST SETUP...................................................................9 7.3. PROCEDURE OF RADIATED EMISSION TEST................................................10 7.4. GRAPHS AND DATA.........................................................................................11 APPENDIX 1 PHOTOGRAPHS OF TEST SETUP ...........................................................13 APPENDIX 2 PHOTOGRAPHS OF EUT ..........................................................................15 (Note: N/A means not applicable) Report No. : EESZD04290009-2 Page 3 of 18 1. GENERAL INFORMATION Applicant: At Box Technology Inc. 2F. -3, No. 716, JhongJheng Rd., JhengHe Dist., New Taipei City, Taiwan Manufacturer: At Box Technology Inc. 2F. -3, No. 716, JhongJheng Rd., JhengHe Dist., New Taipei City, Taiwan Authorization: Certification Product Name: HelloNurse Trade Name: At Box Model Name: NV-TX100 FCC ID: ZLLNV-TRUX100 Serial Number: N/A Report Number: EESZD04290009-2 Date of Test: May 03, 2011 to May 23, 2011 The above equipment was tested by CENTRE TESTING INTERNATIONAL (SHENZHEN) CORPORATION for compliance with the requirements set forth in FCC Rules and the measurement procedure according to ANSI C63.4-2009. The test results of this report relate only to the tested sample identified in this report. Date May 23, 2011 Report No. : EESZD04290009-2 Page 4 of 18 2. TEST SUMMARY The EUT has been tested according to the following specifications: Standard Test Item Test FCC 15.107 Conducted Emission Yes FCC 15.109 Radiated Emission Yes 3. MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Test item Value (dB) Conducted Emission 2.6 Radiated Emission 4.4 4. PRODUCT INFORMATION AND TEST SETUP 4.1. PRODUCT INFORMATION Technical Data 5V/ 600mA, 3W Adapter information: M/N: GS2U-003-050-A Input: AC 100-240V, 50/60Hz Output: DC 5V, 600mA, 3W max 4.2. TEST SETUP CONFIGURATION See test photographs attached in Appendix 1 for the actual connections between EUT and support equipment. 4.3. SUPPORT EQUIPMENT No. Device Type Brand Model Series No. Data Cable 3. PC Lenovo PCG-3G1T 282170999014058 N/A 4. Monitor IBM 9205-AB6 VK-KZ133 Un-shielded 1.2M 5. Mouse IBM M028UOL 23-468157 Un-shielded 1.2M 6. Keyboard IBM 89P8300 02284699 Un-shielded 1.2M Notes: 1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended use. Report No. : EESZD04290009-2 Page 5 of 18 5. FACILITIES AND ACCREDITATIONS 5.1. TEST FACILITY All test facilities used to collect the test data are located at Building C, Hongwei Industrial Zone, Baoan 70 District, Shenzhen, Guangdong, China. The site and apparatus are constructed in conformance with the requirements of ANSI C63.4, CISPR 1…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Tingjun Hu
[email protected](02)8227-8877#36Fax: (02)8227-8792

Test Firm

CENTRE TESTING INTERNATIONAL CORPORATIONChristy Chen
[email protected]86-755-33683362Fax: 86-755-33683385

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from At Box Technology Inc.

Transmitter of Wireless Patient Monitoring System - FCC ID ZLLNV-TX100 - At Box Technology Inc.
ZLLNV-TX100

Transmitter of Wireless Patient Monitoring System

May 25, 2011

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral