FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. FLIR Systems AB/
  3. ZLV-FLIRE49001

ZLV-FLIRE49001Infrared Camera

FLIR Systems AB
Infrared Camera - FCC ID ZLV-FLIRE49001 - FLIR Systems AB
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 23, 2012
Application Purpose
Original Equipment
Date of Application
Feb 23, 2012
Equipment Note
Infrared Camera
Frequency Range
2412.00000000 - 2462.00000000
Company
FLIR Systems AB
Country
Sweden

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User’smanual FLIRExxseries T559597Publ. No. a554Revision English(EN)Language September27, 2011Issuedate User’smanual Publ. No. T559597Rev. a554– ENGLISH(EN)– September27, 2011 Legaldisclaimer All productsmanufacturedby FLIRSystemsare warrantedagainstdefectivematerialsand workmanshipfor a periodof one (1) yearfromthe deliverydateof the originalpurchase,providedsuchproductshavebeenundernormalstorage,use and service,and in accordancewith FLIRSystemsinstruction. Productswhichare not manufacturedby FLIRSystemsbut includedin systemsdeliveredby FLIRSystemsto the originalpurchaser, carry the warranty, if any, of the particularsupplieronly. FLIRSystemshas no responsibilitywhatsoeverfor suchproducts. The warrantyextendsonlyto the originalpurchaserand is not transferable.It is not applicableto any productwhichhas beensubjectedto misuse,neglect,accidentor abnormalconditionsof operation.Expendablepartsare excludedfromthe warranty. In the caseof a defectin a productcoveredby this warrantythe productmustnot be furtherusedin orderto preventadditionaldamage.The purchasershallpromptlyreportany defectto FLIRSystemsor this warrantywill not apply. FLIRSystemswill, at its option,repairor replaceany suchdefectiveproductfree of chargeif, uponinspection,it provesto be defectivein materialor workmanshipand providedthat it is returnedto FLIRSystemswithinthe saidone-yearperiod. FLIRSystemshas no otherobligationor liabilityfor defectsthanthoseset forthabove. No otherwarrantyis expressedor implied.FLIRSystemsspecificallydisclaimsthe impliedwarrantiesof merchantabilityand fitnessfor a particularpurpose. FLIRSystemsshallnot be liablefor any direct,indirect,special,incidentalor consequentialloss or damage,whetherbasedon contract,tort or any otherlegaltheory. Thiswarrantyshallbe governedby Swedishlaw. Any dispute,controversyor claimarisingout of or in connectionwiththis warranty, shallbe finallysettledby arbitrationin accordancewith the Rulesof the ArbitrationInstituteof the StockholmChamberof Commerce.The placeof arbitrationshallbe Stockholm.The languageto be usedin the arbitralproceedingsshallbe English. U.S. GovernmentRegulations ■ The productsdescribedin the userdocumentationmayrequiregovernmentauthorizationfor export/re-export,or transfer. ContactFLIR Systemsfor details. ■ Dependingon licenseand exportprocedures,lensesmaybe permanentlyfixedto camerasshippedto customersoutsideUnitedStates. Interchangeablelensesfall underU.S. Departmentof Statejurisdiction. Copyright © 2011,FLIRSystems.All rightsreservedworldwide.No partsof the softwareincludingsourcecodemay be reproduced,transmitted,transcribed or translatedinto any languageor computerlanguagein any formor by any means,electronic,magnetic,optical,manualor otherwise, withoutthe priorwrittenpermissionof FLIRSystems. Thisdocumentationmustnot, in wholeor part,be copied,photocopied,reproduced,translatedor transmittedto any electronicmediumor machinereadableformwithoutpriorconsent,in writing,fromFLIRSystems. Namesand marksappearingon the productshereinare eitherregisteredtrademarksor trademarksof FLIRSystemsand/orits subsidiaries. All othertrademarks,tradenamesor companynamesreferencedhereinare usedfor identificationonly and are the propertyof theirrespective owners. Qualityassurance The QualityManagementSystemunderwhichtheseproductsare developedand manufacturedhas beencertifiedin accordancewiththe ISO 9001standard. FLIRSystemsis committedto a policyof continuousdevelopment;thereforewe reservethe rightto makechangesand improvementson any of the productsdescribedin this manualwithoutpriornotice. Patents Oneor severalof the followingpatentsor designpatentsapplyto the productsand/orfeaturesdescribedin this manual: 0002258-2;000279476-0001;000439161;000499579-0001;000653423;000726344;000859020;000889290;001106306-0001;001707738; 001707746;001707787;001776519;0101577-5;0102150-0;0200629-4;0300911-5;0302837-0;1144833;1182246;1182620;1188086; 1285345;1287138;1299699;1325808;1336775;1365299;1402918;1404291;1678485;1732314;200530018812.0;200830143636.7; 2106017;235308;3006596;3006597;466540;483782;484155;518836;60004227.8;60122153.2;602004011681.5-08;6707044;68657; 7034300;7110035;7154093;7157705;7237946;7312822;7332716;7336823;7544944;75530;7667198;7809258;7826736;D540838; D549758;D579475;D584755;D599,392;DI6702302-9;DI6703574-4;DI6803572-1;DI6803853-4;DI6903617-9;DM/057692;DM/061609; ZL00809178.1;ZL01823221.3;ZL01823226.4;ZL02331553.9;ZL02331554.7;ZL200480034894.0;ZL200530120994.2;ZL200630130114.4; ZL200730151141.4;ZL200730339504.7;ZL200830128581.2. EULATerms ■ You haveacquireda device(“INFRAREDCAMERA”) that includessoftwarelicensedby FLIRSystemsAB fromMicrosoftLicensing,GP or its affiliates(“MS”).Thoseinstalledsoftwareproductsof MS origin,as well as associatedmedia,printedmaterials,and “online”or electronicdocumentation(“SOFTWARE”)are protectedby internationalintellectualpropertylawsand treaties.The SOFTWAREis licensed, not sold.All rightsreserved. ivPubl. No. T559597Rev. a554– ENGLISH(EN)– September27, 2011 ■ IF YOU DO NOTAGREETO THISENDUSERLICENSEAGREEMENT(“EULA”), DO NOTUSETHEDEVICEOR COPY THESOFTWARE. INSTEAD, PROMPTLY CONTACTFLIRSystemsAB FORINSTRUCTIONSON RETURNOF THEUNUSEDDEVICE(S)FORA REFUND. ANY USE OF THE SOFTWARE, INCLUDINGBUT NOT LIMITEDTO USE ON THE DEVICE, WILL CONSTITUTEYOUR AGREEMENT TO THIS EULA(OR RATIFICATIONOF ANY PREVIOUSCONSENT). ■ GRANTOF SOFTWARE LICENSE.ThisEULAgrantsyou the followinglicense: ■ You mayuse the SOFTWAREonlyon the DEVICE. ■ NOT FAULT TOLERANT.THESOFTWAREIS NOTFAULT TOLERANT. FLIRSystemsAB HASINDEPENDENTLY DETERMINED HOWTO USETHESOFTWAREIN THEDEVICE, ANDMS HASRELIEDUPONFLIRSystemsAB TO CONDUCTSUFFICIENTTESTING TO DETERMINETHAT THESOFTWAREIS SUITABLEFORSUCHUSE. ■ NO WARRANTIESFOR THE SOFTWARE.THESOFTWAREis provided“AS IS” and with all faults.THEENTIRERISKAS TO SAT- ISFACTORYQUALITY, PERFORMANCE, ACCURACY, ANDEFFORT(INCLUDINGLACKOF NEGLIGENCE)IS WITHYOU. ALSO, THEREIS NO WARRANTYAGAINSTINTERFERENCEWITHYOURENJOYMENTOF THESOFTWAREOR AGAINSTINFRI…

Text truncated - open the document above for the full version.

External Photos

Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 95 of 112 Annex B External photographs of the EUT Photo documentation: Photo 1: Photo 2: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 96 of 112 Photo 3: Photo 4: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 97 of 112 Photo 5: Photo 6: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 98 of 112 Photo 7: Photo 8: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 99 of 112 Photo 9: Photo 10:

ID Label/Location Info

Text alignment of label T126914

Internal Photos

Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 100 of 112 Annex C Internal photographs of the EUT Photo documentation: Photo 1: Photo 2: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 101 of 112 Photo 3: Photo 4: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 102 of 112 Photo 5: Photo 6: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 103 of 112 Photo 7: Photo 8: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 104 of 112 Photo 9: Photo 10: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 105 of 112 Photo 11: Photo 12: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 106 of 112 Photo 13: Photo 14: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 107 of 112 Photo 15: Photo 16: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 108 of 112 Photo 17: Photo 18: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 109 of 112 Photo 19: Photo 20: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 110 of 112 Photo 21: Photo 22:

RF Exposure Info

2011-07-25 Page 1 of 35 TEST REPORT Test Report No.: 1-3325-01-06/11-A Testing Laboratory Applicant CETECOM ICT Services GmbH Untertürkheimer Straße 6 – 10 66117 Saarbrücken/Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Test Laboratory: The test laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 DAR registration number: D-PL-12076-01-01 FLIR Systems AB Rinkebyvägen 19 SE-182 11 Danderyd/SWEDEN Phone: +46 (0) 8 753 27 50 Contact: Olof Gawell e-mail: [email protected] Phone: +46 (0) 8 753 2637 Fax: Manufacturer FLIR Systems AB Rinkebyvägen 19 SE-182 11 Danderyd/SWEDEN Test Standard/s OET Bulletin 65 Supplement C Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields RSS-102 Issue 4 Radio Frequency Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Infrared Camera Device type: portable device Model name: FLIR-E49001 S/N serial number: 49000006 FCC-ID: ZLV- FLIRE49001 IC: 5306A-FLIRE49001 Hardware status: T198045-01 Software status: 1.14.9 Frequency: see technical details Antenna: integrated antenna, max. gain -5dBi Battery option: Li-ion battery 3.7V / 4.4Ah Test sample status: identical prototype Exposure category: general population / uncontrolled environment This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test Report authorised: Test performed: 2011-07-25 Thomas Vogler 2011-04-26 Oleksandr Hnatovskiy Test report no.: 1-3325-01-06/11-A 2011-07-25 Page 2 of 35 1 Table of contents 1 Table of contents ....................................................................................................................................... 2 2 General information .................................................................................................................................. 3 2.1 Notes ................................................................................................................................................ 3 2.2 Application details ......................................................................................................................... 3 2.3 Statement of compliance ............................................................................................................... 3 2.4 Technical details............................................................................................................................. 3 3 Test standard/s: ......................................................................................................................................... 4 3.1 RF exposure limits ......................................................................................................................... 4 4 Summary of Measurement Results ......................................................................................................... 5 5 Test Environment ...................................................................................................................................... 5 6 Test Set-up ................................................................................................................................................. 6 6.1 Measurement system ..................................................................................................................... 6 6.1.1 System Description ................................................................................................................ 6 6.1.2 Test environment ................................................................................................................... 7 6.1.3 Probe description ................................................................................................................... 7 6.1.4 Phantom description .............................................................................................................. 8 6.1.5 Device holder description ...................................................................................................... 8 6.1.6 Scanning procedure .............................................................................................................. 9 6.1.7 Spatial Peak SAR Evaluation .............................................................................................. 10 6.1.8 Data Storage and Evaluation............................................................................................... 11 6.1.9 Tissue simulating liquids: dielectric properties .................................................................... 13 6.1.10 Tissue simulating liquids: parameters ................................................................................. 13 6.1.11 Measurement uncertainty evaluation for SAR test .............................................................. 14 6.1.12 Measurement uncertainty evaluation for system validation ................................................ 15 6.1.13 System validation ................................................................................................................ 16 6.1.14 Validation procedure ............................................................................................................ 16 7 Detailed Test Results .............................................................................................................................. 17 7.1 Conducted power measurements ............................................................................................... 17 7.2 SAR test results ............................................................................................................................ 17 7.2.1 Results overview ................…

Text truncated - open the document above for the full version.

RF Exposure Info

2011-04-26 Page 1 of 30 TEST REPORT Test Report No.: 1-3325-01-06/11-A Testing Laboratory CETECOM ICT Services GmbH Untertürkheimer Straße 6 – 10 66117 Saarbrücken/Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Test Laboratory: The test laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 DAR registration number: DAT-P-176/94-D1 Appendix with Calibration data, Phantom certificate and system validation information 2011-04-26 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 2 of 30 1 Table of contents 1 Table of contents ....................................................................................................................................... 2 2 Calibration report “Probe ET3DV6” ......................................................................................................... 3 3 Calibration report “2450 MHz System validation dipole” .................................................................... 14 4 Calibration certificate of Data Acquisition Unit (DAE) ........................................................................ 23 5 Certificate of “SAM Twin Phantom V4.0/V4.0C’’ ................................................................................. 24 6 Application Note System Performance Check ..................................................................................... 25 6.1 Purpose of system performance check ..................................................................................... 25 6.2 System Performance check procedure ...................................................................................... 25 6.3 Uncertainty Budget ...................................................................................................................... 26 6.4 Power set-up for validation ......................................................................................................... 29 6.5 Laboratory reflection ................................................................................................................... 30 6.6 Additional system checks ........................................................................................................... 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 3 of 30 2 Calibration report “Probe ET3DV6” Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 4 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 5 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 6 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 7 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 8 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 9 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 10 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 11 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 12 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 13 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 14 of 30 3 Calibration report “2450 MHz System validation dipole” Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 15 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 16 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 17 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 18 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 19 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 20 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 21 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 22 of 30 Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 23 of 30 4 Calibration certificate of Data Acquisition Unit (DAE) Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 24 of 30 5 Certificate of “SAM Twin Phantom V4.0/V4.0C’’ Test report no.: 1-3325-01-06/11-A 2011-04-26 Page 25 of 30 6 Application Note System Performance Check 6.1 Purpose of system performance check The system performance check verifies that the system operates within its specifications. System and operator errors can be detected and corrected. It is recommended that the system performance check is performed prior to any usage of the system in order to guarantee reproducible results. The measurement of the Specific Absorption Rate (SAR) is a complicated task and the result depends on the proper functioning of many components and the correct settings of many parameters. Faulty results due to drift, failures or incorrect parameters might not be recognized, since they often look similar in distribution to the correct ones. The Dosimetric Assessment System DASY4 incorporates a system performance check procedure to test the proper functioning of the system. The system performance check uses normal SAR measurements in a simplified setup (the flat section of the SAM Twin Phantom) with a well characterized source (a matched dipole at a specified distance). This setup was selected to give a high sensitivity to all parameters that might fail or vary over time (e.g., probe, liquid parameters, and software settings) and a low sensitivity to external effects inherent in the system (e.g., positioning uncertainty of the device holder). The system performance check does not replace the calibration of the components. The accuracy of the system performance check is not sufficient for calibration purposes. It is possible to calculate the field quite accurately in this simple setup; however, due to the open field situation some factors (e.g., laboratory reflections) cannot be accounted for. Calibrations in the flat phantom are possible with transfer calibration methods, using either temperature probes or calibrated E-field probes. The system performance check also does not test the system performance for arbitrary field situations encountered during real measurements of mobile phones. These checks are performed at SPEAG by testing the components under various conditions (e.g., spherical isotropy measurements in liquid, linearity measurements, temperature…

Text truncated - open the document above for the full version.

Test Report

2012-02-23 Page 1 of 105 TEST REPORT Test report no.: 1-3325/11-02-02-A Testing laboratory Applicant CETECOM ICT Services GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12076-01-01 Area of Testing: Radio/Satellite Communications FLIR Systems AB Rinkebyvägen 19 SE-182 11 Danderyd / SWEDEN Phone: +46 (0) 8 753 27 50 Fax: -/- Contact: Göran Skedung e-mail: [email protected] Phone: +46 87 53 27 59 Manufacturer FLIR Systems AB Rinkebyvägen 19 SE-182 11 Danderyd / SWEDEN Test standard/s 47 CFR Part 15 Title 47 of the Code of Federal Regulations; Chapter I Part 15 - Radio frequency devices RSS - 210 Issue 8 Spectrum Management and Telecommunications - Radio Standards Specification Low-power Licence-exempt Radiocommunication Devices (All Frequency Bands): Category I Equipment For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Infrared Camera Model name: FLIR-E49001 FCC ID: ZLV-FLIRE49001 IC: 5306A-FLIRE49001 Frequency [MHz]: ISM-band: 2400 MHz – 2483.5 MHz (lowest channel 01 – 2412 MHz, highest channel 11 – 2462 MHz) Technology tested: WLAN (b & g – mode) Antenna: Integrated antenna Power Supply: 3.7 V DC by Li – polymer battery Temperature Range: 20°C This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorised: Test performed: Marco Bertolino Andreas Luckenbill Testing Manager Test report no.: 1-3325/11-02-02-A 2012-02-21 Page 2 of 105 1 Table of contents 1 Table of contents ..................................................................................................................................... 2 2 General information ................................................................................................................................. 3 2.1 Notes and disclaimer ..................................................................................................................... 3 2.2 Application details ......................................................................................................................... 3 3 Test standard/s ........................................................................................................................................ 3 4 Test environment ..................................................................................................................................... 4 5 Test item ................................................................................................................................................... 4 6 Test laboratories sub-contracted ............................................................................................................ 4 7 Summary of measurement results .......................................................................................................... 5 8 RF measurements .................................................................................................................................... 6 8.1 Description of test setup ............................................................................................................... 6 8.1.1 Radiated measurements ....................................................................................................... 6 8.1.2 Conducted measurements .................................................................................................... 7 8.2 Additional comments .................................................................................................................... 7 8.3 RSP100 test report cover sheet / performance test data ............................................................. 8 9 Measurement results ............................................................................................................................... 9 9.1 Maximum output power (conducted) ............................................................................................ 9 9.2 Antenna gain................................................................................................................................ 16 9.3 Maximum output power............................................................................................................... 19 9.4 Power spectral density ................................................................................................................ 21 9.5 Spectrum bandwidth of a FHSS system – 6 dB bandwidth ....................................................... 26 9.6 Spectrum bandwidth of a FHSS system – 20 dB bandwidth ..................................................... 31 9.7 Band edge compliance conducted ............................................................................................. 36 9.8 Band edge compliance radiated ................................................................................................. 39 9.9 TX spurious emissions conducted ............................................................................................. 44 9.10 TX spurious emissions radiated.............................................................................................. 56 9.11 RX spurious emissions radiated ............................................................................................. 73 9.12 TX spurious emissions radiated < 30 MHz .............................................................................. 79 9.13 TX spurious emissions conduct…

Text truncated - open the document above for the full version.

Test Setup Photos

Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 92 of 112 Annex A Photographs of the test setup Photo documentation: Photo 1: Photo 2: Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 93 of 112 Photo 3: (Chamber F) Photo 4: (Chamber F) Test report no.: 1-3325/11-02-03-A 2012-02-23 Page 94 of 112 Photo 5: (Chamber F)

Contact Information

Applicant

Bjorn Svensson(Director, Quality Assurance)
[email protected]+4687532610Fax: +4687532364

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]49-681-598-0Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz37.10 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with other antennas or transmitters. The highest reported SAR for body-worn operation is 0.80 W/kg.

Other Applications from FLIR Systems AB

ZLV-FLIRI1846

Infrared Camera

Feb 27, 2026

Equipment Class

DTS - Digital Transmission System
Infrared Camera - FCC ID ZLV-FLIRC8940 - FLIR Systems AB
ZLV-FLIRC8940

Infrared Camera

Jun 09, 2020

Equipment Class

DTS - Digital Transmission System
Infrared Camera - FCC ID ZLV-FLIRT7250 - FLIR Systems AB
ZLV-FLIRT7250

Infrared Camera

Nov 16, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Borescope - FCC ID ZLV-VS - FLIR Systems AB
ZLV-VS

Borescope

Jan 13, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Humidity meter with Bluetooth - FCC ID ZLV-MR7X - FLIR Systems AB
ZLV-MR7X

Humidity meter with Bluetooth

Nov 10, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter