!"# Date: June 2#20 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 Subject : E-Label FCC ID : ZNFG900UM To Whom It May Concern: We, LG Electronics USA, Inc. state that at the time of purchase, the FCC ID is readily and physically visible to the purchaser on the packaging Label per 2.925(d). The FCC ID will be able to survive normal shipping and handling, so it is visible for inspection at the time of import. We have programmed the e-label and it is not able to be modified by any third party. Also, SIM Card in is not required to access the FCC ID number. Sincerely, LG Electronics USA, Inc. 111 Sylvan Avenue Englewood Cliffs, NJ 07632 Kyung-Su Han Director LG Electronics USA,Inc
PCTEST TCB/CB Div. of PCTEST Engineering Lab., Inc. 6660-B Dobbin Road Columbia, MD 21045 SUBJECT: LG Electronics USA, Inc. FCC ID: ZNFG900UM 5G Sub-6GHz HAC Attestation Date: June 2, 2020 To Whom It May Concern: We, LG Electronics USA, Inc. attest the handset as designed is expected to exhibit similar audio intensity levels between a OTT VoIP call placed over a 4G LTE and a 5G Sub-6GHz data connection. This device does not currently support VoNR but does not prohibit VoNR after sale when supported by the CMRS service provider. Should you have any questions or comments concerning the above, please contact the undersigned. Sincerely, Kyung-Su Han Director LG Electronics USA,Inc Englewood Cliffs, NJ 07632 !"# LG Electronics USA, Inc. 111 Sylvan Avenue
Date : June 1, 2020
Date: June 2, 2020 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 RE: Request of Confidentiality for FCC ID: ZNFG900UM Equipment Class: DTS: Digital Transmission System To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules (CFR 47), and Section 552 (b) (4) of the Freedom of Information Act, LG Electronics USA, Inc. hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant an d prov ide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA 04-1705. This provision will give LG Electronics USA, Inc. temporary confidentiality of commercially sensitive information prior to product release. The requested Permanent and Temporary Confidential exhibits are listed as follows: PERMANENT AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description 1 Block Diagram 2 Operational Descriptions PERMANENT 3 Schematics 4 External Photos 5 Internal Photos 6 Test-Setup Photos SHORT-TERM 7 User’s Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Sincerely, Kyung-Su Han Director LG Electronics USA, Inc. LG El ectronics USA, Inc. 111 Sylvan Avenue Englewood Cliffs, NJ 07632
LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM External Photos EUT Type: Portable Handset Page 1 of 8 © 2020 PCTEST V 9.0 02/01/2019 E X T E R N A L P H O T O G R A P H S LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM External Photos EUT Type: Portable Handset Page 2 of 8 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM External Photos EUT Type: Portable Handset Page 3 of 8 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM External Photos EUT Type: Portable Handset Page 4 of 8 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM External Photos EUT Type: Portable Handset Page 5 of 8 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM External Photos EUT Type: Portable Handset Page 6 of 8 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM External Photos EUT Type: Portable Handset Page 7 of 8 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM External Photos EUT Type: Portable Handset Page 8 of 8 © 2020 PCTEST V 9.0 02/01/2019
Description of E-Label on the ZNFG900UM ※FCC ID is applied by E-Label on the device ※Instruction of E-Label on the user manual ※FCC ID is Applied on packaging Label Settings Menu Step 1 Select “Settings” Step 2 Select “System” Step 3 Select “Regulatory & safety” FCC ID : ZNFG900UM
LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM Internal Photos EUT Type: Portable Handset Page 1 of 11 © 2020 PCTEST V 9.0 02/01/2019 I N T E R N A L P H O T O G R A P H S LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM Internal Photos EUT Type: Portable Handset Page 2 of 11 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM Internal Photos EUT Type: Portable Handset Page 3 of 11 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM Internal Photos EUT Type: Portable Handset Page 4 of 11 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM Internal Photos EUT Type: Portable Handset Page 5 of 11 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM Internal Photos EUT Type: Portable Handset Page 6 of 11 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM Internal Photos EUT Type: Portable Handset Page 7 of 11 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM Internal Photos EUT Type: Portable Handset Page 8 of 11 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM Internal Photos EUT Type: Portable Handset Page 9 of 11 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM Internal Photos EUT Type: Portable Handset Page 10 of 11 © 2020 PCTEST V 9.0 02/01/2019 LG Electronics USA, Inc. FCC ID: ZNFG900UM Model: LM-G900UM Internal Photos EUT Type: Portable Handset Page 11 of 11 © 2020 PCTEST V 9.0 02/01/2019
© 2020 PCTEST APPENDIX A: SAR TEST DATA A1 PCTEST DUT: ZNFG900UM; Type: Portable Handset; Serial: 03600 Communication System: UID 0, GSM GPRS; 4 Tx slots; Frequency: 836.6 MHz; Duty Cycle: 1:2.076 Medium: 835 Head; Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.907 S/m; ε r = 41.468; ρ = 1000 kg/m 3 Phantom section: Left Section Test Date: 04/05/2020; Ambient Temp: 21.0°C; Tissue Temp: 20.2°C Probe: EX3DV4 - SN7551; ConvF(9.88, 9.88, 9.88) @ 836.6 MHz; Calibrated: 9/19/2019 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1333; Calibrated: 9/17/2019 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1792 Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7483) Mode: GPRS 850, Left Head, Cheek, Mid.ch, 4 Tx slots Area Scan (9x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 11.13 V/m; Power Drift = -0.11 dB Peak SAR (extrapolated) = 0.153 W/kg SAR(1 g) = 0.116 W/kg 0 dB = 0.140 W/kg = -8.54 dBW/kg A2 PCTEST DUT: ZNFG900UM; Type: Portable Handset; Serial: 03600 Communication System: UID 0, GSM GPRS; 3 Tx slots; Frequency: 1880 MHz; Duty Cycle: 1:2.76 Medium: 1900 Head Medium parameters used: f = 1880 MHz; σ = 1.423 S/m; ε r = 38.688; ρ = 1000 kg/m 3 Phantom section: Left Section Test Date: 04/27/2020; Ambient Temp: 22.3°C; Tissue Temp: 20.3°C Probe: EX3DV4 - SN7406; ConvF(8.18, 8.18, 8.18) @ 1880 MHz; Calibrated: 5/16/2019 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn728; Calibrated: 5/8/2019 Phantom: Twin-SAM V5.0 Left 20; Type: QD 000 P40 CD; Serial: 1715 Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7483) Mode: GPRS 1900, Left Head, Cheek, Mid.ch, 3 Tx slots Area Scan (9x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.630 V/m; Power Drift = 0.21 dB Peak SAR (extrapolated) = 0.0700 W/kg SAR(1 g) = 0.042 W/kg 0 dB = 0.0569 W/kg = -12.45 dBW/kg A3 PCTEST DUT: ZNFG900UM; Type: Portable Handset; Serial: 03618 Communication System: UID 0, UMTS; Frequency: 836.6 MHz; Duty Cycle: 1:1 Medium: 835 Head Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.935 S/m; ε r = 42.938; ρ = 1000 kg/m 3 Phantom section: Left Section Test Date: 04/13/2020; Ambient Temp: 21.7°C; Tissue Temp: 20.4°C Probe: EX3DV4 - SN7551; ConvF(9.88, 9.88, 9.88) @ 836.6 MHz; Calibrated: 9/19/2019 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1333; Calibrated: 9/17/2019 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1792 Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7483) Mode: UMTS 850, Left Head, Cheek, Mid.ch Area Scan (9x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 13.09 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.209 W/kg SAR(1 g) = 0.158 W/kg 0 dB = 0.190 W/kg = -7.21 dBW/kg A4 PCTEST DUT: ZNFG900UM; Type: Portable Handset; Serial: 03618 Communication System: UID 0, UMTS; Frequency: 1732.4 MHz; Duty Cycle: 1:1 Medium: 1750 Head; Medium parameters used (interpolated): f = 1732.4 MHz; σ = 1.36 S/m; ε r = 39.722; ρ = 1000 kg/m 3 Phantom section: Left Section Test Date: 03/26/2020; Ambient Temp: 20.2°C; Tissue Temp: 19.7°C Probe: EX3DV4 - SN7551; ConvF(8.34, 8.34, 8.34) @ 1732.4 MHz; Calibrated: 9/19/2019 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1333; Calibrated: 9/17/2019 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1792 Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7483) Mode: UMTS 1750, Left Head, Cheek, Mid.ch Area Scan (9x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 8.368 V/m; Power Drift = 0.21 dB Peak SAR (extrapolated) = 0.144 W/kg SAR(1 g) = 0.093 W/kg 0 dB = 0.120 W/kg = -9.21 dBW/kg A5 PCTEST DUT: ZNFG900UM; Type: Portable Handset; Serial: 03592 Communication System: UID 0, UMTS; Frequency: 1880 MHz; Duty Cycle: 1:1 Medium: 1900 Head; Medium parameters used: f = 1880 MHz; σ = 1.431 S/m; ε r = 39.084; ρ = 1000 kg/m 3 Phantom section: Left Section Test Date: 03/30/2020; Ambient Temp: 21.2°C; Tissue Temp: 21.2°C Probe: EX3DV4 - SN7406; ConvF(8.18, 8.18, 8.18) @ 1880 MHz; Calibrated: 5/16/2019 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn728; Calibrated: 5/8/2019 Phantom: Twin-SAM V5.0 Left 30; Type: QD 000 P40 CD; Serial: 1715 Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7483) Mode: UMTS 1900, Left Head, Cheek, Mid.ch Area Scan (9x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 8.442 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 0.156 W/kg SAR(1 g) = 0.097 W/kg 0 dB = 0.133 W/kg = -8.76 dBW/kg A6 PCTEST DUT: ZNFG900UM; Type: Portable Handset; Serial: 03618 Communication System: UID 0, CDMA; Frequency: 836.52 MHz; Duty Cycle: 1:1 Medium: 835 Head Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.915 S/m; ε r = 43.353; ρ = 1000 kg/m 3 Phantom section: Left Section Test Date: 04/22/2020; Ambient Temp: 21.0°C; Tissue Temp: 20.3°C Probe: EX3DV4 - SN7551; ConvF(9.88, 9.88, 9.88) @ 836.52 MHz; Calibrated: 9/19/2019 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1333; Calibrated: 9/17/2019 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1792 Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7483) Mode: Cell. CDMA, BC. 0, Left Head, Cheek, Mid.ch Area Scan (9x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 12.75 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 0.185 W/kg SAR(1 g) = 0.142 W/kg 0 dB = 0.170 W/kg = -7.70 dBW/kg A7 PCTEST DUT: ZNFG900UM; Type: Portable Handset; Serial: 03618 Communicat…
Text truncated - open the document above for the full version.
Object: Date Issued: Page 1 of 4 D750V3 – SN:1161 10/18/2019 Certification of Calibration Object D750V3 – SN:1161 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extended Calibration date: October 18, 2019 Description: SAR Validation Dipole at 750 MHz. Calibration Equipment used: Note: CBT (Calibrated Before Testing). Prior to testing, the measurement paths containing a cable, amplifier, attenuator, coupler or filter were connected to a calibrated source (i.e. a signal generator) to determine the losses of the measurement path. Measurement Uncertainty = ±23% (k=2) Name Function Signature Calibrated By: Brodie Halbfoster Team Lead Engineer Approved By: Kaitlin O’Keefe Senior Technical Manager Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Control Company 4040Therm./Clock/Humidity Monitor 6/29/2019 Biennial 6/29/2021 192291470 Control Company 4352Ultra Long Stem Thermometer 8/2/2018 Biennial 8/2/2020 181334684 Amplifier Research 15S1G6 Amplifier CBTN/A CBT433971 Narda 4772-3 Attenuator (3dB) CBTN/A CBT9406 Keysight Technologies 85033E Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) 7/2/2019 Annual 7/2/2020 MY53401181 Rohde & Schwarz ZNLE6 Vector Network Analyzer 10/11/2019 Annual 10/11/2020 101307 Mini-Circuits BW-N20W5+ DC to 18 GHz Precision Fixed 20 dB Attenuator CBTN/A CBTN/A SPEAG DAKS-3.5 Portable Dielectric Assessment Kit 8/13/2019 Annual 8/13/2020 1041 Anritsu MA2411B Pulse Power Sensor 8/14/2019 Annual 8/14/2020 1315051 Anritsu MA2411B Pulse Power Sensor 8/8/2019 Annual 8/8/2020 1339008 Anritsu ML2495A Power Meter 11/20/2018 Annual 11/20/2019 1039008 Agilent N5182A MXG Vector Signal Generator 8/19/2019 Annual 8/19/2020 MY47420837 Seekonk NC-100 Torque Wrench 5/9/2018 Biennial 5/9/2020 22217 Mini-Circuits NLP-2950+ Low Pass Filter DC to 2700 MHz CBTN/A CBTN/A MiniCircuits ZHDC-16-63-S+Bidirectional Coupler CBTN/ACBTN/A MiniCircuits VLF-6000+ Low Pass Filter CBTN/ACBTN/A SPEAG EX3DV4 SAR Probe 4/24/2019 Annual 4/24/2020 7357 SPEAG EX3DV4 SAR Probe 7/16/2019 Annual 7/16/2020 7410 SPEAG DAE4 Dasy Data Acquisition Electronics 7/11/2019 Annual 7/11/2020 1322 SPEAG DAE4 Dasy Data Acquisition Electronics 4/18/2019 Annual 4/18/2020 1407 PCTEST ENGINEERING LABORATORY, INC. 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.pctest.com Object: Date Issued: Page 2 of 4 D750V3 – SN:1161 10/18/2019 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements: 1. The measured SAR does not deviate more than 10% from the target on the calibration certifi c ate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ω from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 2-year calibration period from the calibration date: Calibration Date Extension Date Certificate Electrical Delay (ns) Certificate SAR Target Head (1g) W/kg @ 23.0 dBm Measured Head SAR (1g) W/kg @ 23.0 dBm Deviation 1g (%) Certificate SAR Target Head (10g) W/kg @ 23.0 dBm Measured Head SAR (10g) W/kg @ 23.0 dBm Deviation 10g (%) Certificate Impedance Head (Ohm) Real Measured Impedance Head (Ohm) Real Difference (Ohm) Real Certificate Impedance Head (Ohm) Imaginary Measured Impedance Head (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Head (dB) Measured Return Loss Head (dB) Deviation (%) PASS/FAIL 10/19/201810/18/20191.0321.611.642.12%1.051.082.66%55.653.22.4-1.9-3.41.5-25-26.8-7.30%PASS Calibration Date Extension Date Certificate Electrical Delay (ns) Certificate SAR Target Body (1g) W/kg @ 23.0 dBm Measured Body SAR (1g) W/kg @ 23.0 dBm Deviation 1g (%) Certificate SAR Target Body (10g) W/kg @ 23.0 dBm Measured Body SAR (10g) W/kg @ 23.0 dBm Deviation 10g (%) Certificate Impedance Body (Ohm) Real Measured Impedance Body (Ohm) Real Difference (Ohm) Real Certificate Impedance Body (Ohm) Imaginary Measured Impedance Body (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Body (dB) Measured Return Loss Body (dB) Deviation (%) PASS/FAIL 10/19/201810/18/20191.0321.691.764.39%1.111.175.41%50.6500.6-4.2-40.2-27.6-28.1-1.60%PASS Object: Date Issued: Page 3 of 4 D750V3 – SN:1161 10/18/2019 Impedance & Return-Loss Measurement Plot for Head TSL Object: Date Issued: Page 4 of 4 D750V3 – SN:1161 10/18/2019 Impedance & Return-Loss Measurement Plot for Body TSL Object: Date Issued: Page 1 of 4 D835V2 – SN:4d133 10/18/2019 Certification of Calibration Object D835V2 – SN:4d133 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extended Calibration date: October 18, 2019 Description: SAR Validation Dipole at 835 MHz. Calibration Equipment used: Note: CBT (Calibrated Before Testing). Prior to testing, the measurement paths containing a cable, amplifier, attenuator, coupler or filter were connected to a calibrated source (i.e. a signal generator) to determine the losses of the measurement path. Measurement Uncertainty = ±23% (k=2) Name Function Signature Calibrated By: Brodie Halbfoster Team Lead Engineer Approved By: Kaitlin O’Keefe Senior Technical Manager Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Control Company 4040Therm./Clock/Humidity Monitor 6/29/2019 Biennial 6/29/2021 192291470 Control Company 4352Ultra Long Stem Thermometer 8/2/2018 Biennial 8/2/2020 181334684 Amplifier Research 15S1G6 Amplifier CBTN/A CBT433971 Narda 4772-3 Attenuator (3dB) CBTN/A CBT9406 Keysight Technologies 85033E Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) 7/2/2019 Annual 7/2/2020 MY53401181 Rohde & Schwarz ZNLE6 Vect…
Text truncated - open the document above for the full version.
Object: Date Issued: Page 1 of 4 D1900V2 – SN: 5d080 10/18/2019 Certification of Calibration Object D1900V2 – SN:5d080 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extended Calibration date: October 18, 2019 Description: SAR Validation Dipole at 1900 MHz. Calibration Equipment used: Note: CBT (Calibrated Before Testing). Prior to testing, the measurement paths containing a cable, amplifier, attenuator, coupler or filter were connected to a calibrated source (i.e. a signal generator) to determine the losses of the measurement path. Measurement Uncertainty = ±23% (k=2) Name Function Signature Calibrated By: Brodie Halbfoster Team Lead Engineer Approved By: Kaitlin O’Keefe Senior Technical Manager Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Control Company 4040Therm./Clock/Humidity Monitor 6/29/2019 Biennial 6/29/2021 192291470 Control Company 4352Ultra Long Stem Thermometer 8/2/2018 Biennial 8/2/2020 181334684 Amplifier Research 15S1G6 Amplifier CBTN/A CBT433971 Narda 4772-3 Attenuator (3dB) CBTN/A CBT9406 Keysight Technologies 85033E Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) 7/2/2019 Annual 7/2/2020 MY53401181 Rohde & Schwarz ZNLE6 Vector Network Analyzer 10/11/2019 Annual 10/11/2020 101307 Mini-Circuits BW-N20W5+ DC to 18 GHz Precision Fixed 20 dB Attenuator CBTN/A CBTN/A SPEAG DAKS-3.5 Portable Dielectric Assessment Kit 8/13/2019 Annual 8/13/2020 1041 Anritsu MA2411B Pulse Power Sensor 8/14/2019 Annual 8/14/2020 1315051 Anritsu MA2411B Pulse Power Sensor 8/8/2019 Annual 8/8/2020 1339008 Anritsu ML2495A Power Meter 11/20/2018 Annual 11/20/2019 1039008 Agilent N5182A MXG Vector Signal Generator 8/19/2019 Annual 8/19/2020 MY47420837 Seekonk NC-100 Torque Wrench 5/9/2018 Biennial 5/9/2020 22217 Mini-Circuits NLP-2950+ Low Pass Filter DC to 2700 MHz CBTN/A CBTN/A MiniCircuits ZHDC-16-63-S+Bidirectional Coupler CBTN/ACBTN/A MiniCircuits VLF-6000+ Low Pass Filter CBTN/ACBTN/A SPEAG EX3DV4 SAR Probe 2/19/2019 Annual 2/19/2020 3914 SPEAG EX3DV4 SAR Probe 5/16/2019 Annual 5/16/2020 7406 SPEAG DAE4 Dasy Data Acquisition Electronics 5/8/2019 Annual 5/8/2020 859 SPEAG DAE4 Dasy Data Acquisition Electronics 2/14/2019 Annual 2/14/2020 1272 PCTEST ENGINEERING LABORATORY, INC. 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.pctest.com Object: Date Issued: Page 2 of 4 D1900V2 – SN: 5d080 10/18/2019 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements: 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ω from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 2-year calibration period from the calibration date: Calibration Date Extension Date Certificate Electrical Delay (ns) Certificate SAR Target Head (1g) W/kg @ 20.0 dBm Measured Head SAR (1g) W/kg @ 20.0 dBm Deviation 1g (%) Certificate SAR Target Head (10g) W/kg @ 20.0 dBm Measured Head SAR (10g) W/kg @ 20.0 dBm Deviation 10g (%) Certificate Impedance Head (Ohm) Real Measured Impedance Head (Ohm) Real Difference (Ohm) Real Certificate Impedance Head (Ohm) Imaginary Measured Impedance Head (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Head (dB) Measured Return Loss Head (dB) Deviation (%) PASS/FAIL 10/23/201810/18/20191.1933.984.164.52%2.072.132.90%52.550.42.17.96.21.7-21.8-24.2-10.90%PASS Calibration Date Extension Date Certificate Electrical Delay (ns) Certificate SAR Target Body (1g) W/kg @ 20.0 dBm Measured Body SAR (1g) W/kg @ 20.0 dBm Deviation 1g (%) Certificate SAR Target Body (10g) W/kg @ 20.0 dBm Measured Body SAR (10g) W/kg @ 20.0 dBm Deviation 10g (%) Certificate Impedance Body (Ohm) Real Measured I m pedance Body (Ohm) Real Difference (Ohm) Real Certificate Impedance Body (Ohm) Imaginary Measured Impedance Body (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Body (dB) Measured Return Loss Body (dB) Deviation (%) PASS/FAIL 10/23/201810/18/20191.1933.924.217.40%2.062.164.85%48.146.51.68.16.61.5-21.5-22.2-3.40%PASS Object: Date Issued: Page 3 of 4 D1900V2 – SN: 5d080 10/18/2019 Impedance & Return-Loss Measurement Plot for Head TSL Object: Date Issued: Page 4 of 4 D1900V2 – SN: 5d080 10/18/2019 Impedance & Return-Loss Measurement Plot for Body TSL Object: Date Issued: Page 1 of 4 D5GHzV2 – SN: 1057 01/16/2019 Certification of Calibration Object D5GHzV2 – SN: 1057 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extension Calibration date: 1/16/2019 Description: SAR Validation Dipole at 5250, 5600, and 5750 MHz. Calibration Equipment used: Measurement Uncertainty = ±23% (k=2) Name Function Signature Calibrated By: Brodie Halbfoster Test Engineer Approved By: Kaitlin O’Keefe Senior Technical Manager Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Agilent 8753ES S-Parameter Network Analyzer 2/8/2018 Annual 2/8/2019 US39170122 Agilent N5182A MXG Vector Signal Generator 4/18/2018 Annual 4/18/2019 MY47420800 Amplifier Research 15S1G6 Amplifier CBTN/A CBT433971 Anritsu MA2411B Pulse Power Sensor 3/2/2018 Annual 3/2/2019 1207364 Anritsu MA2411B Pulse Power Sensor 3/2/2018 Annual 3/2/2019 1339018 Anritsu ML2495A Power Meter 10/21/2018 Annual 10/21/2019 941001 Control Company 4040Therm./Clock/Humidity Monitor 3/31/2017 Biennial 3/31/2019 170232394 Control Company 4352Ultra Long Stem Thermometer 5/2/2017 Biennial 5/2/2019 170330156 Keysight 772D Dual Directional Coupler CBTN/A CBT MY52180215 …
Text truncated - open the document above for the full version.
FCC ID: ZNFG900UM SAR EVALUATION REPORT Approved by: Quality Manager Document S/N: Test Dates: DUT Type: Page 1 of 196 1M2003200048-01-R2.ZNF 03/25/20 – 05/06/20 Portable Handset © 2020 PCTEST REV 21.4 M 09/11/2019 © 2020 PCTEST. A ll right s reserved. U nless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from PCTEST. If you have any questions about this international copyright or have an enquiry about obtaining additional rights to this report or assembly of contents t hereof , please cont act [email protected]. Applicant Name: Date of Testing: LG Electronics U.S.A., Inc. 03/25/20 – 05/06/20 111 Sylvan Avenue, North Building Test Site/Location: Englewood Cliffs, NJ 07632 PCTEST, Columbia, MD, USA United States Document Serial No.: 1M2003200048-01-R2.ZNF FCC ID: ZNFG900UM APPLICANT: LG ELECTRONICS U.S.A., INC. DUT Type: Portable Handset Application Type: Certification FCC Rule Part(s): CFR §2.1093 Model: Additional Model(s): LM-G900UM LMG900UM, G900UM, LM-G900QM, LMG900QM, G900QM, LM-G901V, LMG901V, G901V Note: This revised Test Report (S/N: 1M2003200048-01-R2.ZNF) supersedes and replaces the previously issued test report on the same subject device for the same type of testing as indicated. Please discard or destroy the previously issued test report(s) and dispose of it accordingly. This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE C95.1-1992 and has been tested in accordance with the measurement procedures specified in Section 1.9 of this report; for North American frequency bands only. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of m y knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Test results reported herein relate only to the item(s) tested. The SAR Tick is an initiative of the Mobile & Wireless Forum (MWF). While a product may be considered eligible, use of the SAR Tick logo requires an agreement with the MWF. Further details can be obtained by emailing: [email protected]. 1g Head (W/kg) 1g Body- Worn (W/kg) 1g Hotspot (W/kg) 10g Phablet (W/kg) PCEGSM/GPRS/EDGE 850824.20 - 848.80 MHz0.130.550.55N/A PCEGSM/GPRS/EDGE 1900 1850.20 - 1909.80 MHz< 0.10.360.75N/A PCEUMTS 850 826.40 - 846.60 MHz0.170.670.67N/A PCEUMTS 1750 1712.4 - 1752.6 MHz0.101.020.602.30 PCEUMTS 1900 1852.4 - 1907.6 MHz0.100.990.762.76 PCECell. CDMA/EVDO 824.70 - 848.31 MHz0.150.610.71N/A PCEPCS CDMA/EVDO 1851.25 - 1908.75 MHz0.110.880.822.84 PCELTE Band 71665.5 - 695.5 MHz0.160.390.39N/A PCELTE Band 12699.7 - 715.3 MHz0.140.350.35N/A PCELTE Band 17706.5 - 713.5 MHzN/AN/AN/AN/A PCELTE Band 13779.5 - 784.5 MHz0.150.420.42N/A PCELTE Band 14790.5 - 795.5 MHz0.170.490.49N/A PCELTE Band 5 (Cell)824.7 - 848.3 MHz0.130.700.70N/A PCELTE Band 66 (AWS)1710.7 - 1779.3 MHz< 0.10.860.692.15 PCELTE Band 4 (AWS)1710.7 - 1754.3 MHzN/AN/AN/AN/A PCELTE Band 2 (PCS)1850.7 - 1909.3 MHz0.130.840.893.14 PCELTE Band 25 (PCS) 1850.7 - 1914.3 MHz0.101.020.812.98 PCELTE Band 30 2307.5 - 2312.5 MHz< 0.10.320.71N/A PCELTE Band 7 2502.5 - 2567.5 MHz< 0.10.420.533.07 PCELTE Band 41 2498.5 - 2687.5 MHz< 0.10.270.372.76 PCENR Band n71 665.5 - 695.5 MHz< 0.10.230.23N/A PCENR Band n5 (Cell) 826.5 - 846.5 MHz0.160.600.60N/A PCENR Band n66 (AWS) 1712.5 - 1777.5 MHz0.230.571.062.81 PCENR Band n2 1852.5 - 1907.5 MHzN/AN/AN/AN/A PCENR Band n25 1852.5 - 1912.5 MHz0.220.631.123.06 PCENR Band n41 2506.02 - 2679.99 MHz< 0.10.240.24N/A DTS2.4 GHz WLAN 2412 - 2462 MHz0.950.200.44N/A NIIU-NII-1 5180 - 5240 MHzN/AN/A0.20N/A NIIU-NII-2A 5260 - 5320 MHz0.240.39N/A1.48 NIIU-NII-2C 5500 - 5720 MHz0.180.10N/A0.46 NIIU-NII-35745 - 5825 MHz 0.140.170.17N/A DSS/DTSBluetooth2402 - 2480 MHz < 0.1< 0.1< 0.1N/A 1.261.55 1.593.85 Simultaneous SAR per KDB 690783 D01v01r03: Band & ModeTx Frequency Equipment Class SAR PCTEST 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.pctest.com SAR EVALUATION REPORT FCC ID: ZNFG900UM SAR EVALUATION REPORT Approved by: Quality Manager Document S/N: Test Dates: DUT Type: Page 2 of 196 1M2003200048-01-R2.ZNF 03/25/20 – 05/06/20 Portable Handset © 2020 PCTEST REV 21.4 M 09/11/2019 © 2020 PCTEST. A ll right s reserved. U nless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from PCTEST. If you have any questions about this international copyright or have an enquiry about obtaining additional rights to this report or assembly of contents t hereof , please cont act [email protected]. TABLE OF CONTENTS 1 DEVICE UNDER TEST .......................................................................................................................3 2 LTE INFORMATION ......................................................................................................................... 16 3 INTRODUCTION .......................................................…
Text truncated - open the document above for the full version.
7185 Oakland Mills Road · Columbia, Maryland · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 3.00 mW |

Bluetooth Earbuds
Equipment Class
DTS - Digital Transmission System
Bluetooth Earbud (Cradle)
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Bluetooth Earbud
Equipment Class
DTS - Digital Transmission System
Portable Handset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Portable Handset
Equipment Class
NII - Unlicensed National Information Infrastructure TX