
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 Important Customer Information WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. When using this product, the safety precautions below must be taken to avoid possible legal liabilities and damages. Retain and follow all product safety and operating instructions. Observe all warnings in the product operating instructions. T o reduce the risk of bodily injury, electric shock, fire, and damage to the equipment, observe the following precautions. ELECTRICAL SAFETY This product is intended for use when supplied with power from the designated battery or power supply unit. Other usage may be dangerous and will invalidate any approval given to this product. 2 Important Customer Information SAFETY PRECAUTIONS FOR PROPER GROUNDING INSTALLATION CAUTION: Connecting to improperly grounded equipment can result in an electric shock to your device. This product is equipped with a USB cable for connecting to a desktop or notebook computer. Be sure your computer is properly grounded (earthed) before connecting this product to the computer. The power supply cord of a desktop or notebook computer has an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet which is properly installed and grounded in accordance with all local codes and ordinances. SAFETY PRECAUTIONS FOR POWER SUPPLY UNIT Use the correct external power sour ce A product should be operated only from the type of power source indicated on the electrical ratings label. If you are not sure of the type of power source 3 Important Customer Information required, consult your authorized service provider or local power company. For a product that operates from battery power or other sources, refer to the operating instructions that are included with the product. Handle battery packs carefully This product contains a Li-ion battery. There is a risk of fire and burns if the battery pack is handled improperly. Do not attempt to open or service the battery pack. Do not disassemble, crush, puncture, short external contacts or circuits, dispose of in fire or water, or expose a battery pack to temperatures higher than 60°C (140°F). WARNING: Danger of explosion if battery is incorrectly replaced. T o reduce risk of fire or burns, do not disassemble, crush, puncture, short external contacts, expose to temperature above 60°C (140°F), or dispose of in fire or water. Replace only with specified batteries. Recycle or dispose of used batteries according to the local regulations or reference 4 Important Customer Information guide supplied with your product. Take extra precautions O Keep the battery or device dry and away from water or any liquid as it may cause a short circuit. O Keep metal objects away so they don’t come in contact with the battery or its connectors as it may lead to short circuit during operation. O The phone should be only connected to products that bear the USB-IF logo or have completed the USB-IF compliance program. O Do not use a battery that appears damaged, deformed, or discolored, or one that has any rust on its casing, overheats, or emits a foul odor. O Always keep the battery out of the reach of babies and small children, to avoid swallowing of the battery. Consult a doctor immediately if the battery is swallowed. O Only use the battery with a charging system that has been qualified with the system per this standard, IEEE- Std-1725-200x. Use of an unqualified battery or charger may present a risk 5 Important Customer Information of fire, explosion, leakage or other hazard. O Replace the battery only with another battery that has been qualified with the system per this standard, IEEE- Std-1725-200x. Use of an unqualified battery may present a risk of fire, explosion, leakage or other hazard. O Avoid dropping the phone or battery. If the phone or battery is dropped, especially on a hard surface, and the user suspects damage, take it to a service center for inspection. O If the battery leaks: Do not allow the leaking fluid to come in contact with skin or clothing. If contact occurs, flush the affected area immediately with clean water and seek medical advice. Do not allow the leaking fluid to come in contact with eyes. If contact occurs, DO NOT rub; rinse with clean water immediately and seek medical advice. Take extra precautions to keep a leaking battery away from fire as there is a danger of ignition or explosion. 6 Important Customer Information SAFETY PRECAUTIONS FOR DIRECT SUNLIGHT Keep this product away from excessive moisture and extreme temperatures. Do not leave the product or its battery inside a vehicle or in places where the temperature may exceed 140°F (60°C), such as on a car dashboard, window sill, or behind glass that is exposed to direct sunlight or strong ultraviolet light for extended periods of time. This may damage the product, overheat the battery, or pose a risk to the vehicle. PREVENTION OF HEARING LOSS CAUTION: Permanent hearing loss may occur if earphones or headphones are used at high volume for prolonged periods of time. SAFETY IN AIRCRAFT Due to the possible interference caused by this product to an aircraft’s navigation system and its communications network, using this device’s phone function on board an airplane is against the law in most countries. If 7 Important Customer Information you want to use this device when its use is restricted on board an aircraft, remember to switch to Airplane Mode which turns off RF functions that could cause interference. ENVIRONMENT RESTRICTIONS Do not use this product in gas stations, fuel depots, chemical plants or where blasting operations are in progress, or in potentially explosive atmospheres such as fueling areas, fuel storehouses, below deck on boats, chemical plants, fuel or chemical transfer or storage facilities, and areas where the air contains chemicals or particles, such as grain, dust, or metal powde…
Text truncated - open the document above for the full version.
Date: May 15, 2012 Compliance Certification Services Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize Ms. Claire Hoque/Application Examiner of Compliance Engineering Services, Inc., d.b.a. Compliance Certification Services and hereafter referred to as CCS, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Ms. Claire Hoque of CCS on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing CCS as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Jacop Cho Director On behalf of LG Electronics Mobilecomm U.S.A.,Inc REMARK: 1.This authorization letter will be sent along with your application when filing with the Certification Division. 2.Please follow the format and type it on company letterhead and send original to us. 3.Authorized signature must be in agreement with grantee code contact in FCC database.
!"# Date: May 8#2 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 RE: Request of Confidentiality for FCC ID: ZNFMS770 Equipment Class:%&% ' ( ) To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules (CFR 47), and Section 552 (b) (4) of the Freedom of Information Act, MobileComm hereby requests confidentiality and treatment of certain information accompanying this applicati on. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for * days after the grant as outlined in Public Notice DA 04-1705. This provision will give MobileComm temporary confidentiality of commercially sensitive information prior to product release. The request ed Permanent and Temporary Confidential exhibits are listed as follows: %+,'-./+'0'+,/12-'22' 3) 4 - 5 1 Block Diagram 2 Operational Descriptions 3 Parts Lists and Tune-Up Procedure %+,' 4 Schematics 5 External Photos 6 Internal Photos 7 Test-Setup Photos ./+'0'+, 8 User’s Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Sincerely, Jacob Cho Director On behalf of LG Electronics MobileComm U.S.A, Inc. LG Electronics USA 1000 Sylvan Avenue Englewood Cliffs, NJ 07632
Date: May 8, 2012 Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 SUBJECT: LG Electronics Mobilecomm U.S.A FCC ID: ZNFMS770 Part 20.19 Certification Gentlemen: We, LG Electronics MobileComm USA, hereby declare the samples evaluated in this application are equivalent to production samples. Should you have any questions or comments concerning the above, please contact the undersigned. Sincerely, Jacob Cho Director On behalf of LG Electronics MobileComm U.S.A, Inc. LG Electronics Inc. LGE LG Electronics USA 1000 Sylvan Avenue Englewood Cliffs, NJ 07632
Model No: MS770 FCC ID : ZNFMS770 S/N : Made in Korea LG Electronics MobileComm USA, Inc. LGE
Test Laboratory: UL CCS SAR Lab B Date: 4/23/2012 20120423_SystemPerformanceCheck-D2450V2 SN 748 Frequency: 2450 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 2450 MHz; σ = 1.963 mho/m; ε r = 51.149; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(7.44, 7.44, 7.44); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120 Body/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 5.289 mW/g Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 60.158 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 10.4180 SAR(1 g) = 5.05 mW/g; SAR(10 g) = 2.36 mW/g Maximum value of SAR (measured) = 7.170 mW/g 0 dB = 7.170mW/g = 17.11 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/23/2012 20120423_SystemPerformanceCheck-D2450V2 SN 748 Frequency: 2450 MHz; Duty Cycle: 1:1 Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 3.465 mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/24/2012 20120424_SystemPerformanceCheck-D2450V2 SN 748 Frequency: 2450 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 2450 MHz; σ = 1.863 mho/m; ε r = 38.875; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(7.4, 7.4, 7.4); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 5.494 mW/g Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 63.983 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 11.9640 SAR(1 g) = 5.67 mW/g; SAR(10 g) = 2.61 mW/g Maximum value of SAR (measured) = 8.116 mW/g 0 dB = 8.120mW/g = 18.19 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/24/2012 20120424_SystemPerformanceCheck-D2450V2 SN 748 Frequency: 2450 MHz; Duty Cycle: 1:1 Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 4.160 mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/24/2012 20120424_SystemPerformanceCheck-D835V2 SN 4d002 Frequency: 835 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 835 MHz; σ = 0.881 mho/m; ε r = 41.7; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(9.81, 9.81, 9.81); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.087 mW/g Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 36.574 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 1.3940 SAR(1 g) = 0.942 mW/g; SAR(10 g) = 0.621 mW/g Maximum value of SAR (measured) = 1.144 mW/g 0 dB = 1.140mW/g = 1.14 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/24/2012 20120424_SystemPerformanceCheck-D835V2 SN 4d002 Frequency: 835 MHz; Duty Cycle: 1:1 Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 0.810 mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/24/2012 20120424_SystemPerformanceCheck-D835V2 SN 4d002 Frequency: 835 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 835 MHz; σ = 0.989 mho/m; ε r = 55.037; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(10, 10, 10); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120 Body/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.149 mW/g Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 35.618 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 1.4830 SAR(1 g) = 1.01 mW/g; SAR(10 g) = 0.667 mW/g Maximum value of SAR (measured) = 1.224 mW/g 0 dB = 1.220mW/g = 1.73 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/24/2012 20120424_SystemPerformanceCheck-D835V2 SN 4d002 Frequency: 835 MHz; Duty Cycle: 1:1 Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 0.768 mW/g Test Laboratory: UL CCS SAR Lab A Date: 4/25/2012 20120425_SystemPerformanceCheck-D1750V2 SN 1053 Frequency: 1750 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 1750 MHz; σ = 1.323 mho/m; ε r = 38.985; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1239; Calibrated: 10/18/2011 - Probe: EX3DV4 - SN3772; ConvF(7.79, 7.79, 7.79); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM v5.0 (A); Type: QD000P40CC; Serial: 1602 Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 3.314 mW/g Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 58.207 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 6.2410 SAR(1 g) = 3.39 mW/g; SAR(10 g) = 1.79 mW/g Maximum value of SAR (measured) = 4.573 mW/g 0 dB = 4.570mW/g = 13.20 dB mW/g Test Laboratory: UL CCS SAR Lab A Date: 4/25/2012 20120425_SystemPerformanceCheck-D1750V2 SN 1053 Frequency: 1750 MHz; Duty Cycle: 1:1 Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 2.754 mW/g Test Laboratory: UL CCS SAR Lab B Date:…
Text truncated - open the document above for the full version.
Test Laboratory: UL CCS SAR Lab B Date: 4/24/2012 CDMA 2000 Frequency: 836.52 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.883 mho/m; ε r = 41.682; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(9.81, 9.81, 9.81); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Left/Touch_1xRTT_ch 384/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.568 mW/g Left/Touch_1xRTT_ch 384/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 25.644 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 0.7350 SAR(1 g) = 0.603 mW/g; SAR(10 g) = 0.453 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.666 mW/g 0 dB = 0.670mW/g = -3.48 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/24/2012 CDMA 2000 Frequency: 836.52 MHz; Duty Cycle: 1:1 Left/Touch_1xRTT_ch 384/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.574 mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/24/2012 CDMA 2000 Frequency: 836.52 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.883 mho/m; ε r = 41.682; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(9.81, 9.81, 9.81); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Left/Tilt_1xRTT_ch 384/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.326 mW/g Left/Tilt_1xRTT_ch 384/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 20.922 V/m; Power Drift = -0.15 dB Peak SAR (extrapolated) = 0.3990 SAR(1 g) = 0.317 mW/g; SAR(10 g) = 0.241 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.356 mW/g 0 dB = 0.360mW/g = -8.87 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/24/2012 CDMA 2000 Frequency: 836.52 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.883 mho/m; ε r = 41.682; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(9.81, 9.81, 9.81); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Right/Touch_1xRTT_ch 384/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.701 mW/g Right/Touch_1xRTT_ch 384/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 26.619 V/m; Power Drift = 0.15 dB Peak SAR (extrapolated) = 0.7940 SAR(1 g) = 0.585 mW/g; SAR(10 g) = 0.432 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.663 mW/g 0 dB = 0.660mW/g = -3.61 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/24/2012 CDMA 2000 Frequency: 836.52 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.883 mho/m; ε r = 41.682; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(9.81, 9.81, 9.81); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Right/Tilt_1xRTT_ch 384/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.419 mW/g Right/Tilt_1xRTT_ch 384/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 22.062 V/m; Power Drift = -0.17 dB Peak SAR (extrapolated) = 0.4340 SAR(1 g) = 0.350 mW/g; SAR(10 g) = 0.267 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.391 mW/g 0 dB = 0.390mW/g = -8.18 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/27/2012 CDMA2000 Frequency: 824.7 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 825 MHz; σ = 0.994 mho/m; ε r = 55.398; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(10, 10, 10); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120 Rear/1xRTT_SO32_Ch 1013/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.259 mW/g Rear/1xRTT_SO32_Ch 1013/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 35.908 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 1.4810 SAR(1 g) = 1.06 mW/g; SAR(10 g) = 0.738 mW/g Maximum value of SAR (measured) = 1.251 mW/g 0 dB = 1.250mW/g = 1.94 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/27/2012 CDMA2000 Frequency: 824.7 MHz; Duty Cycle: 1:1 Rear/1xRTT_SO32_Ch 1013/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 1.258 mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/27/2012 CDMA2000 Frequency: 836.52 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23…
Text truncated - open the document above for the full version.
Test Laboratory: UL CCS SAR Lab B Date: 4/25/2012 CDMA 2000 - BC1 Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 1880 MHz; σ = 1.361 mho/m; ε r = 41.848; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(8.53, 8.53, 8.53); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Left/Touch_1xRTT_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.590 mW/g Left/Touch_1xRTT_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 21.690 V/m; Power Drift = -0.11 dB Peak SAR (extrapolated) = 0.7760 SAR(1 g) = 0.527 mW/g; SAR(10 g) = 0.333 mW/g Maximum value of SAR (measured) = 0.605 mW/g 0 dB = 0.610mW/g = -4.29 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/25/2012 CDMA 2000 - BC1 Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 1880 MHz; σ = 1.361 mho/m; ε r = 41.848; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(8.53, 8.53, 8.53); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Left/Tilt_1xRTT_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.270 mW/g Left/Tilt_1xRTT_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 16.131 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 0.4470 SAR(1 g) = 0.276 mW/g; SAR(10 g) = 0.161 mW/g Maximum value of SAR (measured) = 0.339 mW/g 0 dB = 0.340mW/g = -9.37 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/25/2012 CDMA 2000 - BC1 Frequency: 1851.25 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.333 mho/m; ε r = 41.981; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(8.53, 8.53, 8.53); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Right/Touch_1xRTT_ch 25/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.919 mW/g Right/Touch_1xRTT_ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 26.284 V/m; Power Drift = 0.00059 dB Peak SAR (extrapolated) = 1.2360 SAR(1 g) = 0.812 mW/g; SAR(10 g) = 0.480 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.000 mW/g 0 dB = 1.000mW/g = 0 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/25/2012 CDMA 2000 - BC1 Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 1880 MHz; σ = 1.361 mho/m; ε r = 41.848; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(8.53, 8.53, 8.53); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Right/Touch_1xRTT_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.931 mW/g Right/Touch_1xRTT_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 26.441 V/m; Power Drift = 0.16 dB Peak SAR (extrapolated) = 1.2800 SAR(1 g) = 0.836 mW/g; SAR(10 g) = 0.501 mW/g Maximum value of SAR (measured) = 1.031 mW/g 0 dB = 1.030mW/g = 0.26 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/25/2012 CDMA 2000 - BC1 Frequency: 1908.75 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.389 mho/m; ε r = 41.739; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(8.53, 8.53, 8.53); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Right/Touch_1xRTT_ch 1175/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.080 mW/g Right/Touch_1xRTT_ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 27.924 V/m; Power Drift = 0.0034 dB Peak SAR (extrapolated) = 1.5170 SAR(1 g) = 0.986 mW/g; SAR(10 g) = 0.585 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.228 mW/g 0 dB = 1.230mW/g = 1.80 dB mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/25/2012 CDMA 2000 - BC1 Frequency: 1908.75 MHz; Duty Cycle: 1:1 Right/Touch_1xRTT_ch 1175/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.069 mW/g Test Laboratory: UL CCS SAR Lab B Date: 4/25/2012 CDMA 2000 - BC1 Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 1880 MHz; σ = 1.361 mho/m; ε r = 41.848; ρ = 1000 kg/m 3 DASY5 Configuration: - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV3 - SN3531; ConvF(8.53, 8.53, 8.53); Calibrated: 12/19/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629 Right/Tilt_1xRTT_ch 600/Area Scan …
Text truncated - open the document above for the full version.
Test Laboratory: UL CCS SAR Lab C Date: 4/28/2012 CDMA 2000 - BC15 Frequency: 1732.5 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 1732.5 MHz; σ = 1.321 m…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 19 | 27 | 1.85 GHz - 1.91 GHz | 703.10 mW | 8M92D7W | 2.5 ppm |

Bluetooth Earbuds
Equipment Class
DTS - Digital Transmission System
Bluetooth Earbud (Cradle)
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Bluetooth Earbud
Equipment Class
DTS - Digital Transmission System
Portable Handset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Portable Handset
Equipment Class
NII - Unlicensed National Information Infrastructure TX