Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
English LG-P760LG-P760 User Guide This guide helps you get started using your phone. If you need more information, please visit www.lg.com. • Some of the contents of this manual may not apply to your phone. This depends on your phone’s software and your service provider. • This handset is not recommended for the visually impaired because of its touch screen keyboard. • Copyright ©2012 LG Electronics, Inc. All rights reserved. LG and the LG logo are registered trademarks of LG Group and its related entities. All other trademarks are the property of their respective owners. • Google™, Maps™, Gmail™, YouTube™, Google Talk™ and Play Store™ are trademarks of Google, Inc. LG-P768f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Ĝ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or Your Safety This publication is available at http://www. fcc.gov/oet/rfsafety or through the FCC at (888) 225-5322 or (888) CALL-FCC. What does “SAR” mean? In 1996, the FCC, working with the FDA, the U.S. Environmental Protection Agency, and other agencies, established RF exposure safety guidelines for wireless phones in the United States. Before a wireless phone model is available for sale to the public, it must be tested by the manufacturer and certified to the FCC that it does not exceed limits established by the FCC. One of these limits is expressed as a Specific Absorption Rate, or “SAR.” SAR is a measure of the rate of absorption of RF energy in the body. Tests for SAR are conducted with the phone transmitting at its highest power level in all tested frequency bands. Since 1996, the FCC has required that the SAR of handheld wireless phones not exceed 1.6 watts per kilogram, averaged over one gram of tissue. Although the SAR is determined at the highest power level, the actual SAR value of a wireless phone while operating can be less than the reported SAR value. This is because the SAR value may vary from call to call, depending on factors such as proximity to a cell site, the proximity of the phone to the body while in use, and the use of hands-free devices. Before a phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government-adopted requirement for safe exposure. The tests are performed in positions and locations (e.g., at the ear and worn on the body) as required by the FCC for each model. The highest SAR value for this model phone when tested for use at the ear is 0.XX W/kg and when worn on the body, as described in this user guide, is X.XX W/kg (body-worn measurements differ among phone models, depending upon available accessories and FCC requirements). While there may be differences between SAR levels of various phones and at various positions, they all meet the government requirement for safe exposure. The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RF emission guidelines. SAR information on this model 15 phone is on file with the FCC and can be found under the Display Grant section of http://…
Text truncated - open the document above for the full version.
FCCID: ZNFP768F Copyright Ⓒ 2012, Digital EMC Co., Ltd. View 1 FCCID: ZNFP768F Copyright Ⓒ 2012, Digital EMC Co., Ltd. View 2 FCCID: ZNFP768F Copyright Ⓒ 2012, Digital EMC Co., Ltd. View 3
Model No: LG-P768f FCC ID : ZNFP768F S/N : Made in Korea LG Electronics MobileComm USA, Inc. LGE
FCCID: ZNFP768F Copyright Ⓒ 2012, Digital EMC Co., Ltd. View 1 FCCID: ZNFP768F Copyright Ⓒ 2012, Digital EMC Co., Ltd. View 2 FCCID: ZNFP768F Copyright Ⓒ 2012, Digital EMC Co., Ltd. View 3 FCCID: ZNFP768F Copyright Ⓒ 2012, Digital EMC Co., Ltd. View 4 FCCID: ZNFP768F Copyright Ⓒ 2012, Digital EMC Co., Ltd. View 5 FCCID: ZNFP768F Copyright Ⓒ 2012, Digital EMC Co., Ltd. View 6 FCCID: ZNFP768F Copyright Ⓒ 2012, Digital EMC Co., Ltd. View 7
Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page2 / 125 Copyright ○ C 2012, Digital EMC Co., Ltd. Table of Contents 1. INTROCUCTION .................................................................................................................................................................. 3 2. DESCRIPTION OF DEVICE ................................................................................................................................................ 4 3. DESCRIPTION OF TEST EQUIPMENT .............................................................................................................................. 5 3.1 SAR MEASUREMENT SETUP ................................................................................................................................... 5 3.2 EX3DV4 Probe Specification ....................................................................................................................................... 6 3.3 Probe Calibration Process ........................................................................................................................................... 7 3.3.1 E-Probe Calibration ................................................................................................................................................ 7 3.4 Data Extrapolation ....................................................................................................................................................... 8 3.5 SAM Twin PHANTOM .................................................................................................................................................. 9 3.6Device Holder for Transmitters ..................................................................................................................................... 9 3.7 Brain & Muscle Simulation Mixture Characterization ................................................................................................. 10 3.8 SAR TEST EQUIPMENT ........................................................................................................................................... 11 4. TEST SYSTEM SPECIFICATIONS ................................................................................................................................... 12 5. SAR MEASUREMENT PROCEDURE ............................................................................................................................... 13 6. DESCRIPTION OF TEST POSITION ................................................................................................................................ 14 6.1 HEAD POSITION ...................................................................................................................................................... 14 6.2 Positioning for Cheek/Touch ...................................................................................................................................... 15 6.3 Positioning for Ear / 15 ° Tilt ...................................................................................................................................... 15 6.4 Body Holster /Belt Clip Configurations ...................................................................................................................... 16 7. IEEE P1528 –MEASUREMENT UNCERTAINTIES ........................................................................................................... 17 8. ANSI / IEEE C95.1-2005 RF EXPOSURE LIMITS ............................................................................................................ 29 9. SYSTEM VERIFICATION .................................................................................................................................................. 30 9.1 Tissue Verification ...................................................................................................................................................... 30 9.2 Test System Validation ............................................................................................................................................... 31 10. Multiple TRANSMITTERS SAR CONSIDERATIONS ..................................................................................................... 32 10.1 SAR for Simultaneous Transmission ....................................................................................................................... 33 10.2 Description of Volume Scan .................................................................................................................................... 38 10.3 SAR Assessment ..................................................................................................................................................... 39 11. Configuring 802.11 a/b/g Transmitters for SAR Measurement ................................................................................... 40 12. SAR Measurement Conditions for UMTS ..................................................................................................................... 41 13. SAR CONSIDERATIONS ................................................................................................................................................ 42 13.1 SAR Test Configurations.......................................................................................................................................... 42 13.2 Antenna Distance .................................................................................................................................................... 42 14. SAR TEST SUMMARY AND POWER TABLE ................................................................................................................ 43 15. SAR TEST DATA RESULTS ............................................................................................................................................ 47 …
Text truncated - open the document above for the full version.
Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page65 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Attachment 1. – Probe Calibration Data G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page66 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page67 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page68 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page69 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page70 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page71 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page72 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page73 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page74 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page75 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page76 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page77 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page78 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page79 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page80 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page81 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page82 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page83 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page84 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page85 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page86 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page87 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page88 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Attachment 2. – Dipole Calibration Data G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page89 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page90 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page91 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page92 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page93 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page94 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page95 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page96 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page97 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page98 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page99 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 TRF-RF-601(00)120709 Page100 / 125 Copyright ̺ C 2012, Digital EMC Co., Ltd.G G G G Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of i…
Text truncated - open the document above for the full version.
Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 Copyright Ⓒ 2012, DIGITAL EMC Co., Ltd. Dipole Validation Plots DIGITAL EMC CO., LTD DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:464 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.879 mho/m; ε r = 40.212; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(8.98, 8.98, 8.98); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-31; Ambient Temp: 22.4; Tissue Temp:22.7 Dipole Validation Area Scan (51x101x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Power Drift = -0.10 dB Peak SAR (extrapolated) = 3.627 mW/g SAR(1 g) = 2.39 W/kg; SAR(10 g) = 1.57 W/kg 0 dB = 2.91 mW/g DIGITAL EMC CO., LTD DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:464 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.879 mho/m; ε r = 40.212; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(8.98, 8.98, 8.98); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-31; Ambient Temp: 22.4; Tissue Temp:22.7 Dipole Validation Area Scan (51x101x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Power Drift = -0.10 dB Peak SAR (extrapolated) = 3.627 mW/g SAR(1 g) = 2.39 W/kg; SAR(10 g) = 1.57 W/kg DIGITAL EMC CO., LTD DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:464 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.985 mho/m; ε r = 53.771; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(9.03, 9.03, 9.03); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-31; Ambient Temp: 22.4; Tissue Temp:22.7 Dipole Validation Area Scan (51x101x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Power Drift = -0.07 dB Peak SAR (extrapolated) = 3.795 mW/g SAR(1 g) = 2.53 W/kg; SAR(10 g) = 1.66 W/kg 0 dB = 3.08 mW/g DIGITAL EMC CO., LTD DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:464 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.985 mho/m; ε r = 53.771; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(9.03, 9.03, 9.03); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-31; Ambient Temp: 22.4; Tissue Temp:22.7 Dipole Validation Area Scan (51x101x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Power Drift = -0.07 dB Peak SAR (extrapolated) = 3.795 mW/g SAR(1 g) = 2.53 W/kg; SAR(10 g) = 1.66 W/kg DIGITAL EMC CO., LTD DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:464 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.886 mho/m; ε r = 40.799; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(8.98, 8.98, 8.98); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-14; Ambient Temp: 22.0; Tissue Temp:22.2 Dipole Validation Area Scan (51x101x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Power Drift = 0.04 dB Peak SAR (extrapolated) = 3.681 mW/g SAR(1 g) = 2.44 W/kg; SAR(10 g) = 1.61 W/kg 0 dB = 2.63 mW/g DIGITAL EMC CO., LTD DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:464 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.886 mho/m; ε r = 40.799; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(8.98, 8.98, 8.98); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-14; Ambient Temp: 22.0; Tissue Temp:22.2 Dipole Validation Area Scan (51x101x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Power Drift = 0.04 dB Peak SAR (extrapolated) = 3.681 mW/g SAR(1 g) = 2.44 W/kg; SAR(10 g) = 1.61 W/kg DIGITAL EMC CO., LTD DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:464 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.966 mho/m; ε r = 54.033; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(9.03, 9.03, 9.03); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-14; Ambient Temp: 22.0; Tissue Temp:22.2 Dipole Validation Area Scan (61x81x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Power Drift = -0.02 dB Peak SAR (extrapolated) = 3.729 mW/g SAR(1 g) = 2.51 W/kg; SAR(10 g) = 1.65 W/kg 0 dB = 3.06 mW/g DIGITAL EMC CO., LTD DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:464 Communication System: CW; Frequency: 835…
Text truncated - open the document above for the full version.
Report No.: DRTFCC1209-0456 FCC ID: ZNFP768f Date of issue: Sept.07, 2012 Copyright Ⓒ 2012, DIGITAL EMC Co., Ltd. SAR Test Plots DIGITAL EMC CO., LTD DUT: LG-P768f; Type: Bar Communication System: GSM 850; Frequency: 836.6 MHz;Duty Cycle: 1:8.3 Medium parameters used: f = 836.6 MHz; σ = 0.88 mho/m; ε r = 40.2; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(8.98, 8.98, 8.98); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-31; Ambient Temp: 22.4; Tissue Temp:22.7 Left Touch, GSM850 Ch. 190, Ant Internal, Standard Battery Area Scan (81x131x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = -0.18 dB Peak SAR (extrapolated) = 0.194 mW/g SAR(1 g) = 0.155 W/kg; SAR(10 g) = 0.118 W/kg 0 dB = 0.177 mW/g DIGITAL EMC CO., LTD DUT: LG-P768f; Type: Bar Communication System: GSM 850; Frequency: 836.6 MHz;Duty Cycle: 1:8.3 Medium parameters used: f = 836.6 MHz; σ = 0.88 mho/m; ε r = 40.2; ρ = 1000 kg/m 3 Phantom section: Right Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(8.98, 8.98, 8.98); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-31; Ambient Temp: 22.4; Tissue Temp:22.7 Right Touch, GSM850 Ch. 190, Ant Internal, Standard Battery Area Scan (81x121x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = 0.09 dB Peak SAR (extrapolated) = 0.265 mW/g SAR(1 g) = 0.214 W/kg; SAR(10 g) = 0.163 W/kg 0 dB = 0.242 mW/g DIGITAL EMC CO., LTD DUT: LG-P768f; Type: Bar Communication System: GSM 850; Frequency: 836.6 MHz;Duty Cycle: 1:8.3 Medium parameters used: f = 836.6 MHz; σ = 0.88 mho/m; ε r = 40.2; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(8.98, 8.98, 8.98); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-31; Ambient Temp: 22.4; Tissue Temp:22.7 Left Tilt, GSM850 Ch. 190, Ant Internal, Standard Battery Area Scan (81x131x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = -0.13 dB Peak SAR (extrapolated) = 0.168 mW/g SAR(1 g) = 0.135 W/kg; SAR(10 g) = 0.104 W/kg 0 dB = 0.155 mW/g DIGITAL EMC CO., LTD DUT: LG-P768f; Type: Bar Communication System: GSM 850; Frequency: 836.6 MHz;Duty Cycle: 1:8.3 Medium parameters used: f = 836.6 MHz; σ = 0.88 mho/m; ε r = 40.2; ρ = 1000 kg/m 3 Phantom section: Right Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(8.98, 8.98, 8.98); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-31; Ambient Temp: 22.4; Tissue Temp:22.7 Right Tilt, GSM850 Ch. 190, Ant Internal, Standard Battery Area Scan (81x121x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = -0.00 dB Peak SAR (extrapolated) = 0.158 mW/g SAR(1 g) = 0.126 W/kg; SAR(10 g) = 0.096 W/kg 0 dB = 0.144 mW/g DIGITAL EMC CO., LTD DUT: LG-P768f; Type: Bar Communication System: GSM 850_11; Frequency: 836.6 MHz;Duty Cycle: 1:2.77 Medium parameters used: f = 836.6 MHz; σ = 0.88 mho/m; ε r = 40.2; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(8.98, 8.98, 8.98); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-31; Ambient Temp: 22.4; Tissue Temp:22.7 Left Touch, GSM850 GPRS 3 Tx Ch. 190, Ant Internal, Standard Battery Area Scan (81x131x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = -0.07 dB Peak SAR (extrapolated) = 0.321 mW/g SAR(1 g) = 0.264 W/kg; SAR(10 g) = 0.203 W/kg 0 dB = 0.296 mW/g DIGITAL EMC CO., LTD DUT: LG-P768f; Type: Bar Communication System: GSM 850; Frequency: 836.6 MHz;Duty Cycle: 1:8.3 Medium parameters used: f = 836.6 MHz; σ = 0.88 mho/m; ε r = 40.2; ρ = 1000 kg/m 3 Phantom section: Right Section DASY5 Configuration: Probe: EX3DV4 - SN3866; ConvF(8.98, 8.98, 8.98); Calibrated: 2012-06-20; ; Electronics: DAE4 Sn1335 Phantom: SAM with CRP_20120521; Type: SAM; Serial: 1679 Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6477) Test Date: 2012-08-31; Ambient Temp: 22.4; Tissue Temp:22.7 Right Touch, GSM850 GPRS 1 Tx Ch. 190, Ant Internal, Standard Battery Area Scan (81x121x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = -0.07 dB Peak SAR (extrapolated) = 0.263 mW/g SAR(1 g) = 0.207 W/kg; SAR(10 g) = 0.158 W/kg 0 dB = 0.237 mW/g DIGITAL EMC CO., LTD DUT: LG-P768f; Type: Ba…
Text truncated - open the document above for the full version.
6660-B Dobbin Road · Columbia, Maryland · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 3 | 15E | 5.50 GHz - 5.70 GHz | 16.00 mW |

Bluetooth Earbuds
Equipment Class
DTS - Digital Transmission System
Bluetooth Earbud (Cradle)
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Bluetooth Earbud
Equipment Class
DTS - Digital Transmission System
Portable Handset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Portable Handset
Equipment Class
NII - Unlicensed National Information Infrastructure TX