FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Reconyx, Inc./
  3. ZON-HF-RTI

ZON-HF-RTIWireless Trigger and Illuminator for Digital Camera

Reconyx, Inc.
Wireless Trigger and Illuminator for Digital Camera - FCC ID ZON-HF-RTI - Reconyx, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Oct 19, 2011
Application Purpose
Original Equipment
Date of Application
Oct 19, 2011
Equipment Note
Wireless Trigger and Illuminator for Digital Camera
Frequency Range
433.92000000 - 433.92000000
Company
Reconyx, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Appendix G: Manual Please see the following pages. RTI350 REMOTE WIRELESS TRIGGER & ILLUMINATOR INSTRUCTION MANUAL Table of Contents I. RTI350 Overview ................................................................................ 1 II. HyperFire TM RTI350 Controls & Parts Diagram ............................... 2 III. Remote Quick Setup .......................................................................... 3 IV. Batteries & Controls .......................................................................... 4 V. Setup & Programming ....................................................................... 6 VI. Mounting Your Remote...................................................................... 9 VII. WalkTest and System Verification ................................................. 10 VIII. Additional Remote Options ............................................................. 13 IX. Troubleshooting ............................................................................... 14 X. Warranty, FCC, and Safety Information ......................................... 16 XI. Your Information and Warranty Registration ................................ 18 Copyright: October 2011 1 ©RECONYX, Inc. RTI350 Overview Congratulations on purchasing a RECONYX TM RTI350 Wireless Remote Trigger and Illuminator. The HyperFire™ RTI350 is a state-of-the-art wireless Passive InfraRed (PIR) motion detector, and a night time InfraRed (IR) lluminator that is enclosed in a secure, rugged, and weather-resistant case. The RTI350 communicates wirelessly with a Remote Enabled Security or Professional series camera from RECONYX TM up to a range of 100ft. The RTI350’s motion sensor and illuminator can be used either as a supplement to or as a replacement for the camera’s motion sensor and illuminator. In the case where you are using it as a supplement to the camera you will need to be sure the front of the camera is not blocked, or at least the parts of the camera that you are using (i.e. illuminator and/or motion detector). In the case where you want to use the Remote’s illumination and motion sensing capabilities rather than the camera’s, you should turn off these functions on the camera to save power and ensure you get the results you expect. In this case the Camera can then be hidden while exposing only the lens and the light sensor (to the left of the lens). The Remote will serve as the trigger and illuminator in this scenario. Contents of this package:  HyperFire TM RTI350 Wireless Trigger and Illuminator  Adjustable bungee cord for mounting  This instruction manual Other things you will need:  HyperFire TM Professional or Security Camera; enabled for use with the RTI350  12 AA Batteries NOTE: The RTI350 must be run on either NiMH rechargeable batteries or Energizer® 1.5V AA Ultimate Lithium batteries. NOTE: If you have any questions or concerns relating to the operation or functionality of your device, please read the FAQs or contact our Technical Service Department through our website at www.reconyx.com or by calling toll free 866-493-6064. www.reconyx.com 2 HyperFire TM RTI350 Controls & Parts Diagram Infrared Illuminator Handle PIR Motion Detector Padlock Loop Padlock Loop IR Mask WalkTest Light Latch Backlit LCD Status/Menu Panel Battery Bays Weatherproof Gasket - In Use Light - Left Menu Button - Right Menu Button - OK Button - Low Battery Light PIR Sensitivity WARRANTY SEAL On/Off Power Switch Breathable Vent Fake Lens 3 ©RECONYX, Inc. Remote Quick Setup First Time Setup The first time you turn on your RTI350, you will be asked to select what type of batteries you are using (NIMH or Lithium). Once this option is selected the Remote is ready for use with the default settings. Default settings on the Remote unit are:  Illuminator: On  Trigger: On  Channel: 1 Default settings for a Camera that is Remote Enabled are:  Illuminator (on camera): On  Trigger (on camera): On  Receiver: On  Transmitter: On  Channel: 1 NOTE:  The default settings for both devices are set so that the remote unit is configured to be used as a supplement (in addition) to the Camera’s capabilities.  If you want to use the Remote as the only trigger and/or illuminator for the Camera, you should turn off the trigger and/or illuminator on the camera.  If you deploy the camera without the RTI350, you should turn off the “receiver” and “transmitter” on the camera in order to conserve power. The RTI350 will only function with a camera that has been Remote enabled. You can tell if your camera is Remote enabled by looking for this sticker on the inside of your camera. www.reconyx.com 4 Batteries & Controls Accessing the Batteries & Controls To install the batteries, your HyperFire TM RTI350 is easily opened using the latch on the right side of the device. Grasp behind the latch and flip it toward the front. The device will open like a book, allowing access to the batteries, memory card and settings. Weatherproof Enclosure and Breathable Vent Although the RTI350 comes in a weatherproof enclosure, there are a few things to know to maintain the remote.  Each time you open your Remote it’s good practice to make sure the main gasket is seated properly and no debris has gotten into the gasket channel. Also be sure the latch is fully seated when closing your Remote to ensure a weather- tight seal.  There is also a breathable vent (pictured) underneath the latch of the remote. This vent allows the case to equalize the internal pressure with the outside environment while preventing moisture from entering the case. NOTE: If the vent becomes damaged in any way, contact Reconyx for a replacement to prevent damage to your device. 5 ©RECONYX, Inc. Battery Specifications and Installation The RTI350 runs on twelve AA-cell batteries. We highl…

Text truncated - open the document above for the full version.

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Appendix A: FCC/TCB Agency Authorization Letter Please refer to the following page.

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Appendix B: FCC Confidentiality Request Letter Please refer to the following page.

External Photos

Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Appendix I: External Photographs Photograph 4: Bottom Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 5: Front Face Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 6: Rear Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 7: Side with Hinge Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 8: Side with Latch Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 9: Top

ID Label/Location Info

Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Appendix C: ID Label and Label Location Photograph 1: ID Label Sample and Location

Internal Photos

Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Appendix J: Internal Photographs Photograph 10: Device Opened for User Interaction Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 11: Device Opened to Show Illuminator and Power Cable Connected Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 12: Device Opened with Illuminator Removed Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 13: Illuminator PCB - Side 1 Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 14: Illuminator PCB - Side 2 Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 15: Wireless PCB - Side 1 Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 16: Wireless PCB - Side 2

Test Report

Engineering Solutions & Electromagnetic Compatibility Services 360 Herndon Pkwy | Suite 1400 | Herndon | Virginia 20170 Phone: 703.689.0368 | Fax: 703.689.2056 | www.rheintech.com FCC Part 15.231 Certification Application Report Test Lab: Rhein Tech Laboratories, Inc. Tel: 703-689-0368 360 Herndon Parkway Fax: 703-689-2056 Suite 1400 Web: www.rheintech.com Herndon, VA 20170 Email: [email protected] Applicant: Reconyx, Inc. Phone: 866-493-6064 3828 Creekside Lane Suite 2 Holmen WI 54636 Contact: Darrel VanderZee FCC ID ZON-HF-RTI Test Report Date October 12, 2011 Platform N/A RTL Work Order Number 2011110 Model RTI350 RTL Quote Number QRTL11-135 FCC Classification DSC – Part 15 Security/Remote Control Transmitter FCC Rule Part(s) Part 15.231: Periodic operation in the band 40.66 – 40.70 MHz and above 70 MHz (10-01-10) Procedure or Other Guidance ANSI C63.4-2003 Standard for Methods of Measurement of Radio-Noise Emissions Digital Interface Information N/A Frequency Range (MHz) Output Power (W) Frequency Tolerance Emission Designator 433.92 N/A N/A N/A I, the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the identified standard(s) as described in this test report. Modifications made to the equipment during testing in order to achieve compliance with these standards are listed in the report. Furthermore, there was no deviation from, additions to, or exclusions from the applicable parts of FCC Part 2, FCC Part 15 and ANSI C63.4. Signature: Date: October 12, 2011 Typed/Printed Name: Desmond A. Fraser Position: President This report may not be reproduced, except in full, without the written approval of Rhein Tech Laboratories, Inc. and Reconyx, Inc. The test results reported relate only to the item tested. These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by ANSI-ASQ National Accreditation Board/ACLASS. Refer to certificate and scope of accreditation AT-1445. Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Table of Contents 1 General Information .............................................................................................................................. 5 1.1 Scope ............................................................................................................................................ 5 1.2 Modifications ................................................................................................................................. 5 1.3 Test Facility ................................................................................................................................... 5 1.4 Related Submittal(s)/Grant(s) ....................................................................................................... 5 2 Test Information .................................................................................................................................... 6 2.1 Test Justification ........................................................................................................................... 6 2.2 Exercising the EUT ....................................................................................................................... 6 2.3 Test Result Summary .................................................................................................................... 6 2.4 Test System Details ...................................................................................................................... 6 2.5 Configuration of Tested System .................................................................................................... 7 3 Duty Cycle Calculation - FCC 15.35(c) ................................................................................................. 8 4 Transmitter Deactivation – FCC 15.231(a)(2) ..................................................................................... 11 5 Modulated Bandwidth – FCC 15.231(c) .............................................................................................. 12 5.1 Modulated Bandwidth Test Procedure ........................................................................................ 12 5.2 FCC 15.231(c) Limits .................................................................................................................. 12 5.3 Modulated Bandwidth Test Data ................................................................................................. 12 6 Radiated Emissions – FCC 15.209, 15.231 ........................................................................................ 14 6.1 Radiated Fundamental Emissions Test Procedure..................................................................... 14 6.1.1 Radiated Fundamental Emissions Limits Test Data ............................................................... 14 6.2 Radiated Harmonics/Spurious Emissions – FCC 15.231 ........................................................... 14 6.2.1 Radiated Emissions Harmonics/Spurious Test Procedure ..................................................... 14 7 Conducted Emissions ......................................................................................................................... 17 7.1 Site and Test Description ............................................................................................................ 17 7.2 Test Limits ................................................................................................................................... 17 7.3 Conducted Emissions Test Results ............................................................................................ 17 8 Conclusion .......................................................................................................................................... 18 Rhein Tech Laboratories, Inc. Cli…

Text truncated - open the document above for the full version.

Test Setup Photos

Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Appendix H: Test Photographs Photograph 2: Radiated Emissions Rhein Tech Laboratories, Inc. Client: Reconyx, Inc. 360 Herndon Parkway Model: RTI350 Suite 1400 Standard: FCC 15.231 Herndon, VA 20170 http://www.rheintech.com FCC ID: ZON-HF-RTI Report #: 2011110 Photograph 3: Radiated Emissions

Contact Information

Applicant

Darrel VanderZee(General Manager)
[email protected]866-493-6064Fax: 608-779-1344

Technical Contact

Rhein Tech LabsRick McMurray
[email protected]703-689-0459

360 Herndon Parkway · Herndon, Virginia · United States

Test Firm

Rhein Tech Laboratories, Inc.Richard McMurray
[email protected]703-689-0368Fax: 703-689-2056

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Reconyx, Inc.

Digital Camera that uses Wireless Triggers and Illuminators - FCC ID ZON-HF-TRX - Reconyx, Inc.
ZON-HF-TRX

Digital Camera that uses Wireless Triggers and Illuminators

Oct 18, 2011

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter