Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Monnit Wireless Sensors and iMonnit Online Monitoring System User Guide Monnit Wireless Sensors and iMonnit Online Monitoring System User Guide 1 | M-UG01-3A | www.monnit.com | © 2011 Monnit Corp. 2 | M-UG01-3A | www.monnit.com | © 2011 Monnit Corp. Contents FCC Information to Users About Monnit System Requirements The Monnit Wireless Hardware MonnitLink USB Sensor Network Software Installation MonnitLink USB Driver Installation Monnit Gateway Application Installation Hardware Installation (Bringing Sensors Online) Using the iMonnit System Logging into iMonnit.com iMonnit User Interface (Overview) Using “My Account” (Account and Contacts) Selecting the Date Range Using the Sensor List Configuring Sensors (Basic) Configuring Sensors (Advanced) Configure Multiple Sensors Simultaneously Setting Up Notifications and Alerts History and Chart Views Exporting Data (To File) Exporting Data to an External Source Sensor Maps Reports Error Reporting, Troubleshooting and Support Warranty Information 3 4 5 6 10 11 12 14 15 17 18 19 20 21 23 24 26 27 28 29 30 31 31 3 | M-UG01-3A | www.monnit.com | © 2011 Monnit Corp. FCC Information to Users This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications not expressly approved by Monnit could void the user’s authority to operate the equipment. RF Exposure WARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance are not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter. About Monnit Corp. Monnit is a leader in the design and manufacture of turnkey, self-installing, low cost wireless sensor solutions targeted at the commercial, industrial and consumer markets. Monnit’s sensing solutions are designed to be easily installed and used by anyone wanting to remotely monitor information and activities, including: access, presence of water, luminosity, temperature, humidity, and vibration in or around structures, machinery, and various environments. 4 | M-UG01-3A | www.monnit.com | © 2011 Monnit Corp. Please Read Before Proceeding THE WIRELESS SENSORS ARE ACTIVE AND HAVE ALREADY BEEN ASSIGNED TO YOUR CUSTOMER SENSOR NETWORK. YOUR WAR- RANTY IS INVALIDATED IF YOU DISASSEMBLE OR ATTEMPT TO DISASSEMBLE ANY OF THESE DEVICES. 5 | M-UG01-3A | www.monnit.com | © 2011 Monnit Corp. Network and Computer Requirements MonnitLink ™ USB Gateway Computer System Requirements To use your wireless sensors with a MonnitLink USB Gateway you will need a Windows PC with the following: • A MonnitLink ™ USB Wireless Gateway • Windows XP with 512 MB Memory (Windows 7 with 1024 MB Recommended) • 20 MB Free Disk Space • ASP.NET 3.5 ( http://www.asp.net/downloads/essential ) MonnitLink ™ Ethernet Gateway To use your wireless sensors with a MonnitLink Ethernet Gateway you will need the following: • A MonnitLink ™ Ethernet Wireless Gateway • An Internet enabled router with one available Ethernet port or a direct internet ethernet connection. MonnitLink ™ Cellular Gateway To use your wireless sensors with a MonnitLink Cellular Gateway you will need the following: • A MonnitLink ™ Cellular Wireless Gateway • A MonnitLink ™ Cellular Data Plan. Monnit Wireless Hardware Monnit wireless sensor networks consist of MonnitLink ™ Wireless Gateways, Monnit WIT ™ Wireless Sensors and Monnit Sensor Monitoring Software such as iMonnit ™ On- line, Monnit Express ™ PC Software and Monnit Enterprise ™ Server Software. The simplest way to get started with Monnit wireless sensors is to select either a USB or Ethernet version of the gateway and monitor your sensors online through the iMonnit Online Sensor Monitoring and Notification System. MonnitLink USB Gateways require the use of a personal computer running windows XP or later and requires that the computer remain running and connected to the internet in able for the sensors to communicate to the online system. A MonnitLink Ethernet Gateway is a standalone unit that oper- ates continuously without the need for a computer and only requires an Ethernet connection with access to the Internet. A MonnitLink Cellular Gateway is a standalone unit that op- erates continuously without the need for a computer and only requires an Internet data plan available through Monnit. 6 | M-UG01-3A | www.monnit.com | © 2011 Monnit Corp. RF Specifications Operating Frequency902 MHz - 928 MHz Power Output+8 dBm Receiver Sensitivity-102 dBm RF Range250 - 300 ft. non-line-of-sight ModulationFrequency Shift Keying (FSK) 7 | M-UG01-3A | www.monnit.com | © 2011 Monnit Corp. Rugged Plastic Enclosure RP SMA Antenna Power PlugControl Button RP SMA Antenna ConnectorEthernet Port MonnitLink ™ Ethernet Gateway Indicator Lights This device has been designed to operate with …
Text truncated - open the document above for the full version.
UltraTech Group of Labs FCC TCB & IC CB Ultratech’s Accreditations: 0685 FCC 91038 1309 46390-2049 NvLap Lab Code 200093-0 SL2-IN-E-1119R Korea KCC-RRL CA2049 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] July 29, 2011 Ultratech Engineering Labs, Inc. 3000 Bristol Circle Oakville, Ontario L6H 6G4 Subject: Application for Equipment Certification under FCC Part 15, Subpart C, Section 15.247 - Digital Modulation Systems (DTS) Operating in 902 - 928 MHz Band. Applicant: Monnit Corporation Product: MonnitLink USB Wireless Gateway Model No.: GCM-USB FCC ID: ZTL-RFUSB1 Dear Sir/Madam: As appointed agent for Monnit Corporation, we submit the application for equipment certification of the above product. Please review all required documents uploaded to your E-Filing Site. If you have any queries, please do not hesitate to contact us. Yours truly, Dharmajit Solanki Dharmajit Solanki Authorized Agent
ANNEX 2 – EXTERNAL PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 1 ANNEX 2 – EXTERNAL PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 2 ANNEX 2 – EXTERNAL PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 3
Monnit Corp, Model: GCM-USB CSNET *1214* Bottom of MonnitLink USB The following diagrams show the location of the label on the MonnitLink USB Gateway. Monnit FCC - ZTL-RFUSB1 Lbl Wit TM Wireles s Senso r s FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1
ANNEX 3 – INTERNAL PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 1 ANNEX 3 – INTERNAL PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 2 ANNEX 3 – INTERNAL PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 3 ANNEX 3 – INTERNAL PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 4
MonnitLink USB Wireless Gateway Model No.: GCM-USB FCC ID: ZTL-RFUSB1 Applicant: Monnit Corporation 450 South Simmons Way, Suite 670, Kaysville, UT 84037 USA In Accordance With Federal Communications Commission (FCC) Part 15, Subpart C, Section 15.247 Digital Modulation Systems (DTS) Operating in 902 – 928 MHz Band UltraTech's File No.: MONN-004QF15C247 This Test report is Issued under the Authority of Tri M. Luu, BASc Vice President of Engineering UltraTech Group of Labs Date: July 29, 2011 Report Prepared by: Steven Lu Issued Date: July 29, 2011 Tested by: Mr. Hung Trinh Test Dates: March 30 ~ July 12, 2011 The results in this Test Report apply only to the sample(s) tested, and the sample tested is randomly selected. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the US Government. UltraTech 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com , Email: [email protected], Email: [email protected] FCC Korea KCC-RRL 91038 1309 46390-2049 NvLap Lab Code 200093-0 SL2-IN-E-1119R CA2049 FCC Part 15, Subpart C, Section 15.247 – DTS Contents i MonnitLink USB Wireless Gateway, Model: GCM-USB FCC ID: ZTL-RFUSB1 ULTRATECH GROUP OF LABS File #: MONN-004QF15C247 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 July 29, 2011 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) TABLE OF CONTENTS EXHIBIT 1. INTRODUCTION ......................................................................................................................................... 1 1.1. SCOPE......................................................................................................................................................................... 1 1.2. RELATED SUBMITTAL(S)/GRANT(S) .................................................................................................................. 1 1.3. NORMATIVE REFERENCES ................................................................................................................................... 1 EXHIBIT 2. PERFORMANCE ASSESSMENT .............................................................................................................. 2 2.1. CLIENT INFORMATION .......................................................................................................................................... 2 2.2. EQUIPMENT UNDER TEST (EUT) INFORMATION ............................................................................................ 2 2.3. EUT’S TECHNICAL SPECIFICATIONS ................................................................................................................. 3 2.4. LIST OF EUT’S PORTS............................................................................................................................................. 3 2.5. LIST OF ACCESSORIES ........................................................................................................................................... 3 EXHIBIT 3. EUT OPERATING CONDITIONS AND CONFIGURATIONS DURING TESTS ............................... 4 3.1. CLIMATE TEST CONDITIONS ............................................................................................................................... 4 3.2. OPERATIONAL TEST CONDITIONS & ARRANGEMENT FOR TESTS ............................................................ 4 EXHIBIT 4. SUMMARY OF TEST RESULTS ............................................................................................................... 5 4.1. LOCATION OF TESTS.............................................................................................................................................. 5 4.2. APPLICABILITY & SUMMARY OF EMC EMISSION TEST RESULTS ............................................................. 5 4.3. MODIFICATIONS INCORPORATED IN THE EUT FOR COMPLIANCE PURPOSES....................................... 5 EXHIBIT 5. MEASUREMENTS, EXAMINATIONS & TEST DATA FOR EMC EMISSIONS............................... 6 5.1. TEST PROCEDURES................................................................................................................................................. 6 5.2. MEASUREMENT UNCERTAINTIES ...................................................................................................................... 6 5.3. MEASUREMENT EQUIPMENT USED ................................................................................................................... 6 5.4. ESSENTIAL/PRIMARY FUNCTIONS AS DECLARED BY THE MANUACTURER.......................................... 6 5.5. POWER LINE CONDUCTED EMISSIONS [§15.207(A)] ....................................................................................... 7 5.6. OCCUPIED BANDWIDTH [§ 15.247(A)(2)].......................................................................................................... 12 5.7. PEAK CONDUCTED OUTPUT POWER - DTS [§ 15.247(B)(3)]......................................................................... 19 5.8. TRANSMITTER BAND-EDGE & SPURIOUS CONDUCTED EMISSIONS [§ 15.247(D)]................................ 24 5.9. TRANSMITTER SPURIOUS RADIATED EMISSIONS AT 3 METERS [§§ 15.247(D), 15.209 & 15.205] ....... 30 5.10. POWER SPECTRAL DENSITY [§ 15.247(E)] ....................................................................................................... 39 5.11. RF EXPOSURE REQUIRMENTS [§§ 15.247(E)(I), 1.1310 & 2.1091] ................................................................. 43 EXHIBIT 6. TEST EQUIPMENT LIST ......................................................................................................................... 45 EXHIBIT 7. MEASUREMENT UNCERTAINTY.........................................................…
Text truncated - open the document above for the full version.
ANNEX 1 - TEST SETUP PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 1 Power Line Conducted Emissions ANNEX 1 - TEST SETUP PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 2 Power Line Conducted Emissions ANNEX 1 - TEST SETUP PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 3 Tx Radiated Emissions @ 3 Meters ANNEX 1 - TEST SETUP PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 4 Tx Radiated Emissions @ 3 Meters ANNEX 1 - TEST SETUP PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 5 Tx Radiated Emissions @ 3 Meters ANNEX 1 - TEST SETUP PHOTOS Monnit Corporation MonnitLink USB Wireless Gateway, Model GCM-USB FCC ID: ZTL-RFUSB1 IC: 9794A-RFUSB1 A1 - 6 Tx Radiated Emissions @ 3 Meters
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 903 MHz - 927 MHz | 6.10 mW |

ALTA 900 MHz Rechargeable Water Detection Disc
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Monnit Wireless Sensor Module
Equipment Class
DTS - Digital Transmission System