FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Tonly Technology Co., Ltd./
  3. ZVAOH000037

ZVAOH000037BDX Character Robot

Tonly Technology Co., Ltd.

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Apr 28, 2026
Application Purpose
Original Equipment
Equipment Note
BDX Character Robot
Frequency Range
903.90000000 - 905.30000000
Company
Tonly Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Tonly Technology Co., Ltd. Covered Equipment Certification Attestation Letter 2026-04-15 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID:ZVAOH000037 Tonly Technology Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Tonly Technology Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Tonly Technology Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: Xinyuan Chen Title: Compliance Director Company Name: Tonly Technology Co., Ltd. Address: Section 37, Zhongkai High-tech development Zone, Huizhou, Guangdong 516006, China Phone: 86-13825470355 E-Mail: [email protected] Date: 2026-04-15

Cover Letter(s)

Tonly Technology Co., Ltd. 2026-04-15 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint Damon Hu, Guangdong Dongdian Testing Service Co.,Ltd.( Unit 2, Building 1, No.17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808), to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Xinyuan Chen Title: Compliance Director Company Name: Tonly Technology Co., Ltd. Address: Section 37, Zhongkai High-tech development Zone, Huizhou, Guangdong 516006, China Phone: 86-13825470355 E-Mail: [email protected] Date: 2026-04-15

Cover Letter(s)

Tonly Technology Co., Ltd. 2026-04-15 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY – FCC FCC ID: ZVAOH000037 Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☒ Short Term Internal Photos ☐ Permanent* ☒ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☐ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☒ Short Term User’s Manual ☐ Permanent* ☒ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Xinyuan Chen Title: Compliance Director Company Name: Tonly Technology Co., Ltd. Address: Section 37, Zhongkai High-tech development Zone, Huizhou, Guangdong 516006, China Phone: 86-13825470355 E-Mail: [email protected] Date: 2026-04-15

RF Exposure Info

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26030329-2E12 TRF No.: RT-4-E-006Page 1 of 7 RF EXPOSURE REPORT Applicant : Tonly Technology Co., Ltd. Address of Applicant : Section 37, Zhongkai High-tech Development Zone, Huizhou City, Guangdong Province, P.R. China Manufacturer : Tonly Technology Co., Ltd. Address of Manufacturer : Section 37, Zhongkai High-tech Development Zone, Huizhou City, Guangdong Province, P.R. China Equipment under Test : BDX Character Robot Model No. : BDX-PROD-01 FCC ID : ZVAOH000037 Test Standard(s) : KDB447498 D01 General RF Exposure Guidance v06 Report No. : DDT-RE26030329-2E12 Issue Date : 2026/04/24 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26030329-2E12 TRF No.: RT-4-E-006Page 2 of 7 Table of Contents 1.General Test Information..............................................................................................5 1.1.Description of EUT .......................................................................................................5 1.2.Accessories of EUT......................................................................................................5 1.3.Assistant equipment used for test ................................................................................5 1.4.Test laboratory .............................................................................................................5 2.RF Exposure evaluation for FCC .................................................................................6 2.1.Assessment procedure.................................................................................................6 2.2.Assess result ................................................................................................................7 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26030329-2E12 TRF:RT-4-E-006Page 3 of 7 $!CeMetaLims!digital$ Test Report Declare Applicant : Tonly Technology Co., Ltd. Address of Applicant : Section 37, Zhongkai High-tech Development Zone, Huizhou City, Guangdong Province, P.R. China Equipment under Test : BDX Character Robot Model No. : BDX-PROD-01 Manufacturer : Tonly Technology Co., Ltd. Address of Manufacturer : Section 37, Zhongkai High-tech Development Zone, Huizhou City, Guangdong Province, P.R. China Test Standard Used: KDB447498 D01 General RF Exposure Guidance v06 We Declare: The equipment described above is tested by Guangdong Dongdian Testing Service Co., Ltd. and in the configuration tested the equipment complied with the standards specified above. The test results are contained in this test report and Guangdong Dongdian Testing Service Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests. Report No.:DDT-RE26030329-2E12 Date of Receipt:2026/03/05Date of Test:2026/03/05~2026/04/17 Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Guangdong Dongdian Testing Service Co., Ltd. Created: Chen Ziqin Reviewed: Zoe PengApproved: Ella Gong 2026/04/172026/04/242026/04/24 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26030329-2E12 TRF:RT-4-E-006Page 4 of 7 Revision History VersionRevision ContentIssue DateApproved V0Initial issue2026/04/24Ella Gong Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26030329-2E12 TRF:RT-4-E-006Page 5 of 7 1. General Test Information 1.1. Description of EUT EUT Name:BDX Character Robot Model Number:BDX-PROD-01 Difference of model number:/ EUT Function Description:Please reference user manual of this device Power Supply:DC 22.2V from Rechargeable Li-ion Battery Note: The above EUT information is declared by manufacturer and for more detailed features description please refer to the manufacturer's specifications or User's Manual. 1.2. Accessories of EUT AccessoriesManufacturerModel numberDescription Adapter ConnectorN/AN/AN/A 1.3. Assistant equipment used for test AccessoriesManufacturer Model number Description LoRa BackpackN/ALBP-001N/A Battery charging cradle N/ACC-001N/A Remote controlN/AN/AN/A Rechargeable Li-ion Battery N/AI0971A Nominal Voltage: 22.2V DC Rated Capacity: 5600mAh SWITCHING ADAPTER Shenzhen SOY Technology Co., Ltd. SOY- 2401000- 244-B Input: 100-240V ~ 50/60Hz 3.0A Max.Output: 24.0V10.0A 240W 1.4. Test laboratory Guangdong Dongdian Testing Service Co., Ltd. Add.: Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808. Tel.: +86-0769-38826678, http://www.dgddt.com, Email: [email protected]. CNAS Accreditation No. L6451; A2LA Accreditation Number: 3870.01 FCC Designation Number: CN1182, Test Firm Registration Number: 540522 Innovation, Science and Economic Development Canada Site Registration Number: 10288A Conformity Assessment Body identifier: CN0048 VCCI facility registration number: C-20087, T-20088, R-20123, R-20240, G-20118 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26030329-2E12 TRF:RT-4-E-006Page 6 of 7 2. RF Exposure evaluation for FCC 2.1. Assessment procedure Requirement: Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2 m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic FieldStrength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.346141.63(100)*30 1.34-30824/f2.19/f(180/f)*30 30-30027.50.0730.230 300-15…

Text truncated - open the document above for the full version.

Test Report

QR/RD-P01-06B SPECIFICATION 深圳市大显科技有限公司 ShenzhenDaxianTechnologyCo.,Ltd. 通力A45整机868MHz天线组件 TonlyA45CompleteUnit868MHzAntennaassembly 产品规格书 ProductSpecification 客户 connection 通力 Tonly 频段 frequencyrange 860MHz~930MHz 项目名称 entryname A45 版本 edition V02 物料编号 MaterialNo 6J-QRA45-199 颜色 Color 黑色+白色 Black+White 客户料号 CustomerItem Number 290000-019679 环保要求 environmental requirement RF设计 RFDesig RoHSREACH n 结构设计 StructuralDesig ZhuDong.Liu n 周锐斌 RuiBin.Zhou 品质经理 QualityManager 李崇瑞 ChongRui.Li 技术总监 TechnicalDirector 张磊 Lei.Zhang 日期 Date 2026-03-14 深圳市大显科技有限公司 ShenzhenDaxianTechnologyCo.,Ltd. 深圳市龙岗区布吉镇吉华路513号上水径村(国防培训基地 对面)达成工业园综合楼7楼 TEL:0755-28576002 FAX:0755-84276383 上海分部:上海市张江高科技园区集成电路产业区龙东大道 3000号8号楼201室 TEL:021-61630552 FAX:755-84276383 BujiTown,LonggangDistrict,Shenzhen,ChinaJihuaRoad513, ShangshuijingVillage(oppositethenationaldefense trainingbase)DachengIndustrialPark,Building7。 TEL:0755-28576002 FAX:0755-84276383 Room201,Building8,LongDongRoad3000#,SemiconductorIndustry Park,ZhangJiangHitechZone,ShangHai TEL:021-61630552 FAX:755-84276383 客户确认: Customerconfirmation: 装配是否符合贵司要求:□OK□NG Whethertheassemblymeetsyourcompany'srequirements:□OK□NG ConfidentialInformation www.Topant.com.cn Confidentialityrequirements ShenzhenDaxianTechnologyCo.,Ltd.alreadypossessestheinformationprovidedbytheproprietarytechnology,which shouldbestrictlyconfidentialandnotallowedtobedisclosedtoanypersonorcompanywithoutthepriorwrittenconsentof ShenzhenDaxianTechnologyCo.,Ltd Page2 变更履历 Revisionhistory 版本号 Versionnumber 变更内容 Changecontent 变更理由 Reasonforchange 发起变更方 Originating Party 日期 Date 修改人 Modifiedby A1.0 创建 found 2026-01-05 A2.0 更新 modify 增加天线电性能数据 AdditionofAntenna Electrical PerformanceData DX2026-03-02 A3.0 更新 modify 已增天线cable线的实 测插入损耗 Measuredinsertion lossoftheantenna cable DX2026-03-14 ConfidentialInformation www.Topant.com.cn Confidentialityrequirements ShenzhenDaxianTechnologyCo.,Ltd.alreadypossessestheinformationprovidedbytheproprietarytechnology,which shouldbestrictlyconfidentialandnotallowedtobedisclosedtoanypersonorcompanywithoutthepriorwrittenconsentof ShenzhenDaxianTechnologyCo.,Ltd Page3 索引 Indexes 一、项目说明ProjectDescription...................................................................................................................4 二、868MHz天线antenna............................................................................................................4 1、规格specifications.................................................................................................4 1.1电气规格标准Electricalspecificationsandstandards........................................................5 1.1.1电性能指标Electricalperformanceindex................................................................5 1.1.2天线位置图片Antennapositionpicture...................................................................5 1.2结构规格标准Structuralspecificationsandstandards....................................................5 1.2.1天线组成Antennacomposition.............................................................................5 2、测试环境testingenvironment............................................................................................6 3、测试test.....................................................................................................................7 3.1驻波(VSWR)的测试Testofstandingwave(VSWR)........................................................7 3.1.1测试连接Testconnection.......................................................................................7 3.2 效率、功率( TRP )、灵敏度( TIS )的测试 Testingofefficiency,power(TRP),sensitivity(TIS)..................7 3.2.1测试的场地Testsite..............................................................................................7 3.2.2测试的仪表TestedInstruments..............................................................................7 3.2.3测试数据testdata..................................................................................................7 4、VSWR参数图Parameterdiagram......................................................................................................8 5、无源场型图Passivefieldpatterndiagram............................................................................................9 6、结论conclusion........................................................................................................................................9 三、工程图scheduledrawing.............................................................................................10 ConfidentialInformation www.Topant.com.cn Confidentialityrequirements ShenzhenDaxianTechnologyCo.,Ltd.alreadypossessestheinformationprovidedbytheproprietarytechnology,which shouldbestrictlyconfidentialandnotallowedtobedisclosedtoanypersonorcompanywithoutthepriorwrittenconsentof ShenzhenDaxianTechnologyCo.,Ltd Page4 一项目说明ProjectDescription 客户名: CustomerName: 通力 Tonly 整机类型: Typeofcomplete machine: 天线频段: Antennaband Robot : 860MHz~930MHz 天线形式: Antennaform: FPC+同轴线+线材海绵 FPC+coaxialline+wiresponge FPC+同轴线 FPC+CoaxialCable 馈电形式: Feedform: 焊接 weld 硬件版本: Hardwareversion: / 二868MHz天线组件Antennaassembly 1规格specifications 本报告主要提供A45项目天线的各项电气和结构性能参数的测试状况。下图为大显设计的天 线图片。 Thisreportmainlyprovidesthetestingstatusofvariouselectricalandstructuralperformance parametersoftheantennafortheA45project.Thefollowingimageshowsanantennawithalarge displaydesign. 天线外观图 antennaappearingdiagram ConfidentialInformation www.Topant.com.cn Confidentialityrequirements ShenzhenDaxianTechnologyCo.,Ltd.alreadypossessestheinformationprovidedbytheproprietarytechnology,which shouldbestrictlyconfidentialandnotallowedtobedisclosedtoanypersonorcompanywithoutthepriorwrittenconsentof ShenzhenDaxianTechnologyCo.,Ltd Page5 1.1电气规格标准Electricalspecificationsandstandards 1.1.1电性能指标Electricalperformanceindex 天线工作频段在860MHz~930MHz。下表是大显设计和量产天线的电性能的指标. Theoperatingfrequencybandoftheantennaisbetween860and930MHz.Thefollowingtableshows theelectricalperformanceindicatorsoflargedisplaydesignandmassproductionantennas. FrequencyRangeFrequency(MHz)VSWR 868MHzAntenna860~930≤2 1.1.2天线位置图片Antennapositionpicture …

Text truncated - open the document above for the full version.

Test Report

Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE26030329-2E14 TRF No.: RT-4-E-02-029 FCC ID Report-Lora Ver.1.1 Page 1 of 97 RADIO TEST REPORT Applicant : Tonly Technology Co., Ltd. Address of Applicant : Section 37, Zhongkai High-tech Development Zone, Huizhou City, Guangdong Province, P.R. China Manufacturer : Tonly Technology Co., Ltd. Address of Manufacturer : Section 37, Zhongkai High-tech Development Zone, Huizhou City, Guangdong Province, P.R. China Equipment under Test : BDX Character Robot Model No. : BDX-PROD-01 FCC ID : ZVAOH000037 IC : 9976A-OH000037 Test Standard(s) : FCC Rules and Regulations Part 15 Subpart C, ANSI C63.10-2020, RSS-247 Issue 4 July 24, 2025, RSS-Gen Issue 5, Apr. 2018, Amendment 2 (February 2021), ANSI C63.10-2020+Cor.1-2023+C63.10a- 2024+Errata to C63.10a-2024 Report No. : DDT-RE26030329-2E14 Issue Date : 2026/04/24 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE26030329-2E14 TRF No.: RT-4-E-02-029 FCC ID Report-Lora Ver.1.1 Page 2 of 97 Table of Contents 1Summary of test results ......................................................................................................7 2General test information .....................................................................................................8 2.1.Description of EUT .............................................................................................................8 2.2.Accessories of EUT ............................................................................................................9 2.3.Assistant equipment used for test ......................................................................................9 2.4.Block diagram of EUT configuration for test .......................................................................9 2.5.Decision of final test mode .................................................................................................9 2.6.Deviations of test standard ...............................................................................................10 2.7.Test environment conditions.............................................................................................10 2.8.Test laboratory..................................................................................................................10 2.9.Measurement uncertainty .................................................................................................11 3Equipment Used During Conductive Test ........................................................................12 4.20 dB Bandwidth ..............................................................................................................13 4.1.Block diagram of test setup ..............................................................................................13 4.2.Limits ................................................................................................................................13 4.3.Test procedure .................................................................................................................13 4.4.Test result .........................................................................................................................14 4.5.Test graphs.......................................................................................................................15 5.6 dB Bandwidth ................................................................................................................18 5.1.Block diagram of test setup ..............................................................................................18 5.2.Limits ................................................................................................................................18 5.3.Test procedure .................................................................................................................18 5.4.Test result .........................................................................................................................19 5.5.Test graphs.......................................................................................................................20 6.99% Bandwidth.................................................................................................................23 6.1.Block diagram of test setup ..............................................................................................23 6.2.Limits ................................................................................................................................23 6.3.Test procedure .................................................................................................................23 6.4.Test result .........................................................................................................................24 6.5.Test graphs.......................................................................................................................25 7.Maximum Peak Output Power ..........................................................................................31 7.1.Block diagram of test setup ..............................................................................................31 7.2.Limits ................................................................................................................................31 7.3.Test procedure .................................................................................................................31 7.4.Test result .........................................................................................................................32 7.5.Test graphs.......................................................................................................................33 8.Power Spectral Density …

Text truncated - open the document above for the full version.

Test Report

Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE26030329-2E14 RT-4-E-02-029 FCC ID Report-Lora Ver.1.1 Page 51 of 97 11.4. Test result Test Engineer:NATest Site:RF Test System 5# Ambient Condition: 24.3-27.2°C,39.2-44.2%RH Test Date:2026.4.8 Test Power Supply:DC 5V from PCSample Number:DDT-Q26030329 Test ModeAntenna Frequency [MHz] BurstWidth [ms] TotalHops [Num] Result[s]Limit[s]Verdict Lora Hybrid SF7 Ant1Hop108.85 3 0.762≤0.4PASS Lora Hybrid SF9 Ant1Hop357.54710.358≤0.4PASS Lora Hybrid SF10 Ant1Hop329.94210.330≤0.4PASS Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE26030329-2E14 RT-4-E-02-029 FCC ID Report-Lora Ver.1.1 Page 52 of 97 11.5. Test graphs Lora Hybrid SF7_Hop Lora Hybrid SF9_Hop Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE26030329-2E14 RT-4-E-02-029 FCC ID Report-Lora Ver.1.1 Page 53 of 97 Lora Hybrid SF10_Hop Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE26030329-2E14 RT-4-E-02-029 FCC ID Report-Lora Ver.1.1 Page 54 of 97 12. Radiated Emission 12.1. Test equipment EquipmentManufacturerModel No.Serial No.Cal Due To High pass filterMicro-TronicsHPM50102DDT-ZC005612027/02/27 RF cable Zhongke Junchuang Z805UF-NJ-NJ- 10M DDT-ZC055912026/10/10 RF cable Zhongke Junchuang Z805UF-NJ-NJ- 3M DDT-ZC055902026/10/10 RF cable Zhongke Junchuang JCTB510-NJW- NJW-0.6M DDT-ZC045952026/10/10 RF cable Zhongke Junchuang JCT40P-2.92J- 2.92J-1M DDT-ZC038022026/10/10 RF cable Yuhu Technology ZT26S-SMAJ- SMAJ-1M DDT-ZC020372026/10/10 RF cable Zhongke Junchuang JCT40P-2.92J- 2.92J-5M DDT-ZC038002026/10/10 Radiation disturbance fully automated test software TonscendJS32-REDDT-ZC02739/ Pre-amplifierSONOMA310NDDT-ZC019692026/07/06 Pre-amplifierCOM-POWERPAM-840ADDT-ZC016932027/03/05 Pre-amplifierCOM-POWERPAM-118ADDT-ZC012932026/08/10 EMI TEST RECEIVERR&SESU26DDT-ZC019092027/02/27 Micro-Tronics filtersREBESBRM50702DDT-ZC03242/ High pass filterMicro-TronicsHPM50108DDT-ZC005602027/02/27 High Pass filterXi'an XingboXBLBQ-GTA67DDT-ZC021792027/02/27 Micro-Tronics filtersREBESBRM50716DDT-ZC03240/ Broad-Band Horn Antenna SchwarzbeckBBHA 9170DDT-ZC005062027/03/04 Trilog Broadband Antenna SchwarzbeckVULB 9163DDT-ZC020502026/07/25 Hochgewinn- Hornantenne SCHWARZBEC K BBHA 9120 DDDT-ZC021292026/08/11 Active Loop AntennaSchwarzbeckFMZB1519DDT-ZC005242026/08/18 PSA Series Spectrum Analyzer AgilentE4447ADDT-ZC005172027/02/27 Band Reject Filter Group TonscendJS0806-FDDT-ZC05733/ Hochgewinn- Hornantenne SCHWARZBEC K BBHA 9120 DDDT-ZC059222027/01/06 Broadband PreamplifierHPXBP-01G-18GDDT-ZC059232027/01/06 Pre-amplifierCOM-POWERPAM-840ADDT-ZC016932027/03/05 Broad-Band Horn Antenna SchwarzbeckBBHA 9170DDT-ZC005062027/03/04 Signal &Spectrum analyzer R&SFSV40-NDDT-ZC049792026/07/04 SPECTRUM ANALYZER R&SFSU26DDT-ZC002362026/07/06 Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE26030329-2E14 RT-4-E-02-029 FCC ID Report-Lora Ver.1.1 Page 55 of 97 12.2. Block diagram of test setup ANTENNA ELEVATION VARIES FROM1TO4METERS 3m EUTand SupportSystem Turntable 1.5m(L)*1.0m(W)*0.8m(H) Semi-anechoicChamber EMI TestReceiverPC System Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE26030329-2E14 RT-4-E-02-029 FCC ID Report-Lora Ver.1.1 Page 56 of 97 12.3. Limits (1) FCC 15.205 Restricted frequency band MHzMHzMHzGHz 0.090-0.11016.42-16.423399.9-4104.5-5.15 1 0.495-0.50516.69475-16.69525608-6145.35-5.46 2.1735-2.190516.80425-16.80475960-12407.25-7.75 4.125-4.12825.5-25.671300-14278.025-8.5 4.1772&4.1777537.5-38.251435-1626.59.0-9.2 4.2072&4.2077573-74.61645.5-1646.59.3-9.5 6.215-6.21874.8-75.21660-171010.6-12.7 6.26775-6.26825108-121.941718.8-1722.213.25-13.4 6.31175-6.31225123-1382200-230014.47-14.5 8.291-8.294149.9-150.052310-239015.35-16.2 8.362-8.366156.52475-156.525252483.5-250017.7-21.4 8.37625-8.38675156.7-156.92690-290022.01-23.12 8.41425-8.41475162.0125-167.173260-326723.6-24.0 12.29-12.293167.72-173.23332-333931.2-31.8 12.51975-12.52025240-2853345.8-335836.43-36.5 12.57675-12.57725322-335.43600-4400( 2 ) 13.36-13.41 1Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz 2Above 38.6 RSS-Gen section 8.10 Restricted frequency bands* ANTENNA ELEVATION VARIES FROM1TO4METERS 3m EUTand SupportSystem Turntable 1.5m(L)*1.0m(W)*1.5m(H) Semi-anechoicChamber EMI TestReceiver PC System Pre-Amplifier Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE26030329-2E14 RT-4-E-02-029 FCC ID Report-Lora Ver.1.1 Page 57 of 97 MHzMHzMHzGHz 0.090-0.11012.51975-12.52025240-2853.5-4.4 0.495-0.50512.57675-12.57725322-335.44.5-5.15 2.1735-2.190513.36-13.41399.9-4105.35-5.46 3.020-3.02616.42-16.423608-6147.25-7.75 4.125-4.12816.69475-16.69525960-14278.025-8.5 4.1772&4.1777516.80425-16.804751435-1626.59.0-9.2 4.2072&4.2077525.5-25.671645.5-1646.59.3-9.5 5.677-5.68337.5-38.251660-171010.6-12.7 6.215-6.21873-74.61718.8-1722.213.25-13.4 6.26775-6.2682574.8-75.22200-230014.47-14.5 6.31175-6.31225108-1382310-239015.35-16.2 8.291-8.294149.9-150.052483.5-250017.7-21.4 8.362-8.366156.52475-156.525252655-290022.01-23.12 8.37625-8.38675156.7-156.93260-326723.6-24.0 8.41425-8.41475162.0125-167.173332-333931.2-31.8 12.29-12.293167.72-173.23345.8-335836.43-36.5 Above 38.6 * Certain frequency bands listed in table and in bands above 38.6 GHz are designated for licence- exempt applications. These frequency bands and the requirements that apply to related devices are set out in the 200 and 300 series of RSSs. (2) FCC 15.209 Limit & RSS-Gen section 8.9 Limit FREQUENCYDISTANCEFIELD STRENGTHS LIMIT MHzMetersuV/mdBuV/m 0.009 ~ 0.4903002400/F(kHz)67.6-20log(F) 0.490 ~ 1.7053024000/F(kHz)87.6-20log(F) 1.705 ~ 30.0303029.54 30~88310040.0 88~216315043.5 216~960320046.0 960~1000350054.0 Above 10003 74.0 dBuV/m(Peak) 54.0 dBuV/m(Average) Note: (1) The emission limits shown in the above table are based on measurements employing a CISPR QP detector except for the frequency bands 9 - 90 kHz, 110 - 490 kHz and above 1000 MHz, radiated emissions limits in these three ba…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Xinyuan Chen(Compliance Director)
[email protected]Fax: 86-752-2625162

Technical Contact

TONLY ACOUSTIC, INC.Yufeng Zhou
[email protected]

1313 N Grand Ave Ste 193 · Walnut, 91789 · United States

Test Firm

Guangdong Dongdian Testing Service Co., Ltd.Mr. Jamy Yu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C903.9 MHz - 905.3 MHz6.85 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter, except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device is approved with two certified unlicensed transmitters (FCC ID: PD9AX210NG and FCC ID: 2AQ33-DWM1001)

Other Applications from Tonly Technology Co., Ltd.

ZVAOH000038

LoRa Backpack

Apr 28, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
ZVAYY7870E

WIRELESS SPEAKER

Apr 01, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
ZVAYY7871E

WIRELESS SPEAKER

Mar 31, 2026

Equipment Class

DTS - Digital Transmission System
2.1 Soundbar System - FCC ID ZVASB000027 - Tonly Technology Co., Ltd.
ZVASB000027

2.1 Soundbar System

Nov 06, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless Device - FCC ID ZVAASWK002 - Tonly Technology Co., Ltd.
ZVAASWK002

Wireless Device

Dec 22, 2022

Equipment Class

DTS - Digital Transmission System