Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Gemini 2000 Ltd. GemTAG - x501 2 GemTAG - x501U Contactless Smart Card Reader Table of Contents 1.General Information .......................................................................................................... 3 Scope .............................................................................................................................. 3 General Description ......................................................................................................... 3 Features .......................................................................................................................... 5 2.Functional Units ................................................................................................................ 6 Gemini 2000 GemTAG - x501U contactless smart card reader parts .............................. 6 Power Supply .................................................................................................................. 6 Reader to Host interface pinout. ...................................................................................... 7 3.Electrical Characteristics ................................................................................................... 7 Operating Condition Range ............................................................................................. 7 Current Consumption ...................................................................................................... 8 Operating Distance .......................................................................................................... 8 Interface Characteristics .................................................................................................. 8 4.Operating Conditions and Standards ................................................................................ 9 FCC Compliance Statement ............................................................................................ 9 Compliance Information According to 46CFR 2.1077 .................................................... 10 CE Declaration of Conformity ........................................................................................ 10 Mechanical Specifications ............................................................................................. 11 Operating Standards ..................................................................................................... 12 6. Ordering and Contact Information .................................................................................. 13 1. General Information Gemini 2000 Ltd. GemTAG - x501 3 Scope This document describes the basic functionality and the electric specifications of the GemTAG - x501U reader. This contactless reader is designed for an easy reader adaptation to a PC to use this device for test and application purpose. General Description The Gemini 2000 reader GemTAG - x501U is contactless reader based on the CL RC632 reader IC. The CL RC632 is a member of the family of highly integrated reader ICs for contactless communications over frequency 13.56 MHz. All layers of ISO 14443A+B, ISO 15693 as well as MIFARE ® are supported. Gemini 2000 Ltd. GemTAG - x501 4 Picture 2 - x501U – OEM – top view Picture 3- x501U – OEM – bottom view Gemini 2000 Ltd. GemTAG - x501 5 Features Contactless smart card reader Based on CL RC632 reader IC Contactless operating frequency 13.56 MHz Supports MIFARE ® Dual Interface Card ICs and ISO 14443A part 1-4 Supports ISO 14443B - optional Supports MIFARE ® Classic crypto Supports ISO 15693 (optional) Supports Philips ICODE ® - 1 (optional) Typical Operating Distance: 60 – 80 mm CE and FCC compliant USB 1.1 interface Power supply via the USB (5 VDC) Watchdog timer 1 LED indicator (software controlled) In-system firmware upload Unique serial number on each device Supported on Windows 98 OSR2, ME, 2000, XP and Linux, Mac OS Supported cards - Mifare Classic, Mifare Ultralight, Mifare 4K, Mifare Pro and Pro X, JCOP 30, JCOP 31, DESFire and more. Gemini 2000 Ltd. GemTAG - x501 6 2. Functional Units Gemini 2000 GemTAG - x501U contactless smart card reader parts The Gemini 2000 GemTAG - x501U contactless smartcard reader is two PCB design – reader module and antenna. The unit uses USB cable to communicate to the host as well to supply the 5V DCC voltage. The device does not need external power supply. Power Supply The GemTAG - x501U reader is a bus powered 5V USB device. No external power supply needs to be connected to start the reader. Gemini 2000 Ltd. GemTAG - x501 7 Reader to Host interface pinout. This interface is indicated as CON1 on the PCB and is valid for GemTAG-x501U reader model. Pin assignment is described in Table 1. Table 1 – CON1 Pinout Pin number Function Description 1 GND Signal ground 2 NC 3 PRG Program device 4 D- USB D- line 5 D+ USB D+ line 6 Vcc Power supply Picture 4 - x501U – OEM connector pinout 3. Electrical Characteristics Operating Condition Range Relative humidity: up to 90% Symbo l Parameter Conditions Min Typ Max Unit T amb Ambient Temperature - -25 25 75 C VDD DC Supply Voltage DVSS = 0V 4.5 5 5.5 V Table 1 - Operating Condition Range Pin 6 Pin 4 Pin 1 Pin 3 Gemini 2000 Ltd. GemTAG - x501 8 Current Consumption Symbo l Parameter Conditions Min Typ Max Unit I DVDD Supply Current StandBy - 100 - mA Table 2 - Current Consumption Operating Distance Symbo l Parameter Conditions Min Typ Max Unit OD Operating Distance Measured from the reader surface - 0-80 - mm Table 3 - Operating Distance Interface Characteristics 3.4.1 USB Interface Symbo l Parameter Conditions Min Typ Max Unit USB - baud USB – baud rate Cable length max. 1.5 m - 12 - Mbaud Table 4 - USB 1.1 Interface Gemini 2000 Ltd. GemTAG - x501 9 4. Operating Conditions and Standards The GemTAG - x501U fulfills the following requirements for electromagnetic compatibility: FCC part 15 CE FCC Compliance Statement “This device complies with Part 15 …
Text truncated - open the document above for the full version.
GemTAG X501USB Operational Description Re: FCC ID registration GemTAG X501USB is a contactless reader operating at 13.56MHz as defined in the ISO14443 standard. X501USB communicates with ISO14443 contactless cards by means of electromagnetic coupling between the reader antenna and the card antenna for the purpose of energy and data transfer to the card as defined in ISO14443. The same antenna is used for receiving data from the card which then transfers data to the reader via modulating the electromagnetic field emitted by the reader according to ISO14443. X501USB employs a CLRC632 integrated circuit from NXP by the method of a directly matched antenna. The antenna itself comprises of copper traces on a PCB which is part of the reader construction. The baud rates, modulation and emitted power are in compliance with ISO14443 and according to CLRC632 manufacturer specifications. The peak transmitter power is 1 Watt, the antenna gain is 0 dB. The reader incorporates a MCU that is controlled by the host via a set of commands. The MCU controls the operation of the CLRC632 IC. The reader transmission is initiated by the host device and depending on the application the transmission might be either permanent or intermittent.
TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: GEMTAG x501 FCC ID: ZW2X501USB To: FCC Part 15.225: 2011 Subpart C Test Report Serial No: RFI-RPT-RP81486JD06A This Test Report Is Issued Under The Authority Of Chris Guy, Head of Global Approvals: Checked By: Ian Watch Signature: Date of Issue: 30 January 2012 This report is issued in Adobe Acrobat portable document format (PDF). It is only a valid copy of the report if it is being viewed in PDF format with the following security options not allowed: Changing the document, Selecting text and graphics, Adding or changing notes and form fields. This report may not be reproduced other than in full, except with the prior written approval of RFI Global Services Ltd. The results in this report apply only to the sample(s) tested. TEST REPORT SERIAL NO: RFI-RPT-RP81486JD06A VERSION 1.0 ISSUE DATE: 30 JANUARY 2012 Page 2 of 20 RFI Global Services Ltd This page has been left intentionally blank. TEST REPORT SERIAL NO: RFI-RPT-RP81486JD06A VERSION 1.0 ISSUE DATE: 30 JANUARY 2012 RFI Global Services Ltd Page 3 of 20 Table of Contents 1. Customer Information ................................................................................................................ 4 2. Summary of Testing ................................................................................................................... 5 2.1. General Information 5 2.2. Summary of Test Results 5 2.3. Methods and Procedures 5 2.4. Deviations from the Test Specification 5 3. Equipment Under Test (EUT) .................................................................................................... 6 3.1. Identification of Equipment Under Test (EUT) 6 3.2. Description of EUT 6 3.3. Modifications Incorporated in the EUT 6 3.4. Additional Information Related to Testing 6 3.5. Support Equipment 7 4. Operation and Monitoring of the EUT during Testing ............................................................. 8 4.1. Operating Modes 8 4.2. Configuration and Peripherals 8 5. Measurements, Examinations and Derived Results ................................................................ 9 5.1. General Comments 9 5.2. Test Results 10 5.2.1. Transmitter AC Conducted Spurious Emissions 10 5.2.2. Transmitter Fundamental Field Strength 13 5.2.3. Transmitter Radiated Spurious Emissions 14 5.2.4. Transmitter Band Edge Radiated Emissions 16 5.2.5. Transmitter 20 dB Bandwidth 17 5.2.6. Transmitter Frequency Stability (Temperature & Voltage Variation) 18 6. Measurement Uncertainty ........................................................................................................19 Appendix 1. Test Equipment Used ..............................................................................................20 TEST REPORT SERIAL NO: RFI-RPT-RP81486JD06A VERSION 1.0 ISSUE DATE: 30 JANUARY 2012 Page 4 of 20 RFI Global Services Ltd 1. Customer Information Company Name: Gemini 2000 Ltd. Address: Peartree Business Park Ferndown Industrial Park Wimborne Dorset BH21 7PT United Kingdom TEST REPORT SERIAL NO: RFI-RPT-RP81486JD06A VERSION 1.0 ISSUE DATE: 30 JANUARY 2012 RFI Global Services Ltd Page 5 of 20 2. Summary of Testing 2.1. General Information Specification Reference: 47CFR15.225 Specification Title: Code of Federal Regulations Volume 47 (Telecommunications) 2011: Part 15 Subpart C (Radio Frequency Devices) - Section 15.225 Specification Reference: 47CFR15.207 and 47CFR15.209 Specification Title: Code of Federal Regulations Volume 47 (Telecommunications) 2011: Part 15 Subpart C (Intentional Radiators) – Sections 15.207 and 15.209 Site Registration: 209735 Location of Testing: RFI Global Services Ltd, Wade Road, Basingstoke, Hampshire, RG24 8AH. Test Dates: 26 July 2011 to 18 January 2012 2.2. Summary of Test Results FCC Reference (47CFR) Measurement Result Part 15.207 Transmitter AC Conducted Emissions Part 15.225(a)(b)(c)(d) Transmitter Fundamental Field Strength Part 15.209(a)/15.225(d) Transmitter Radiated Emissions Part 15.209(a)/15.225(c)(d) Transmitter Band Edge Radiated Emissions Part 2.1049 Transmitter 20 dB Bandwidth Part 15.225(e) Transmitter Frequency Stability (Temperature & Voltage Variation) Key to Results = Complied = Did not comply 2.3. Methods and Procedures Reference: ANSI C63.4 (2009) Title: American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz Reference: ANSI C63.10 (2009) Title: American National Standard for Testing Unlicensed Wireless Devices 2.4. Deviations from the Test Specification For the measurements contained within this test report, there were no deviations from, additions to, or exclusions from the test specification identified above. TEST REPORT SERIAL NO: RFI-RPT-RP81486JD06A VERSION 1.0 ISSUE DATE: 30 JANUARY 2012 Page 6 of 20 RFI Global Services Ltd 3. Equipment Under Test (EUT) 3.1. Identification of Equipment Under Test (EUT) Brand Name: GEMTAG Model Name or Number: GEMTAG x501 Serial Numbers: 31015 (Radiated Sample) 30457 (AC conducted with 50Ω load fitted to antenna) Hardware Version Number: 3.1 Software Version Number: 3.3 FCC ID: ZW2X501USB 3.2. Description of EUT The equipment under test was a contactless smart card reader. 3.3. Modifications Incorporated in the EUT The following modifications were applied to the EUT during testing: The RFID antenna was disconnected and replaced with a 50Ω dummy load in order to comply with the requirements of the AC conducted emissions test in transmit mode. The standard antenna was connected for all other tests. 3.4. Additional Information Related to Testing Tested Technology: RFID Category of Equipment: Transceiver Channel Spacing: Single channel device Transmit Frequency Range: 13.56 MHz Power Supply Requirement: Nominal 5.0 VDC Minimum 4.25 VDC Maximum 5.75 VDC Tested Temperature Range: Minimum -20°C Maximum 50°C TEST REPORT SERIAL NO: RFI-RPT-RP81486JD06A VERSION 1.0 ISSUE DATE: 30 JANUARY 2012 RFI Global …
Text truncated - open the document above for the full version.
Peartree Business Centre, Cobham Road · Wimborne · United Kingdom
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |

GemTAG CX21
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter