Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Hardware installation Manual OpenVox Communication Co. Limited. URL: www.openvox.cn Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049 1 深圳开源通信有限公司 OpenVox-Best Cost Effective Asterisk Cards OpenVox V100 hardware installation Manual Written by: Carson Wang Date: 06/27/2011 Version:1.00 深圳开源通信有限公司 Hardware installation Manual OpenVox Communication Co. Limited. URL: www.openvox.cn Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049 2 OpenVox-Best Cost Effective Asterisk Cards OpenVox Communication Co. Ltd. Addr: F/3, Building 127, Jindi industrial zone, Futian district, Shenzhen, Guangdong, China 518048,China Tel:+86-755-83460576,Fax:+86-755-83460491 E-Mail:[email protected] [email protected] IM for Sales: [email protected] Business Hours: 9:30AM-17:30PM from Monday-Friday URL:openvox.com.cn Thank You for Choosing OpenVox Products! Hardware installation Manual OpenVox Communication Co. Limited. URL: www.openvox.cn Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049 3 Copyright Copyright© 2011 OpenVox Inc. All rights reserved. No part of this document may be reproduced without prior written permission. Confidentiality Information contained herein is of a highly sensitive nature and is confidential and proprietary to OpenVox Inc. No part may be distributed, reproduced or disclosed orally or in written form to any party other than the direct recipients without the express written consent of OpenVox Inc. Disclaimer OpenVox Inc. reserves the right to modify the design, characteristics, and products at any time without notification or obligation and shall not be held liable for any error or damage of any kind resulting from the use of this document. OpenVox has made every effort to ensure that the information contained in this document is accurate and complete; however, the contents of this document are subject to revision without notice. Contact OpenVox to ensure you have the latest revision of this document. Trademarks All other trademarks mentioned in this document are the property of their respective owners. EMC (pending) FCC Part 15 Class B EN55022 Class B EN55024 General Safety Instructions WARNING The computers that have V100 card installed must comply with the country specific safety regulations. WARNING Only service personnel should install V100 card. WARNING Before you install V100 card or remove the cover from your PC, Unplug the power cord from the computer. WARNING For avoiding personal injuries and damage to your computer,and Hardware installation Manual OpenVox Communication Co. Limited. URL: www.openvox.cn Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049 4 V100 card, make sure the card’bracket is secured to the PC’s Chassis ground by fastening the card with the screw. WARNING Electrical Surges,ESD are very destructive to the equipment. To avoid it,make sure there is a low impedance discharge path from your computer to Chassis ground. WARNING To reduce the risk of damage or injury,follow all steps or procedures as instructed. Release History Vesrsion Date Changes Editor 1.0O 06/27/2011 First preliminary release. Carson Wang FCC Caution Caution: The user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Hardware installation Manual OpenVox Communication Co. Limited. URL: www.openvox.cn Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049 5 Chapter 1 Overview Overview Because of its low bandwidth requirements, The voice data compression Codecs ,such as G.729,G.726,AMR,G.722,iLBC ,etc. are commonly used in VoIP applications.The G.711 Codecs is commonly used in legacy telephone network. For bridging TDM to VoIP connectivity ,it needs Codec transformation. Compared with transformation in software,The V100 ,Based Multicore-DSP ,can convert more sessions of transcoding,relieve the host CPU resources. The V100 card, are rated to handle up to 32,64,128,256,400 bi-directional Codec transformations, without additional licensing fees 1 for transcoding. The V100 card can be worked as PCI /PCIe Form Factors in one board . The V100 is suitable for nomal PCI/low profile PCI applications , and can provide PCI/PCIe/RJ45 media/control flow paths. These features can save the cost and support flexible applications. The V100 can be worked with Asterisk® and FreeSWITCH®. Feature • High density up to 30 to 400 Transcoding • No addionnal License Fee 1 • Small Size 2U Form Factor • PCI&PCIe interface in one board • Supports Low Profile PCI/PCIe • Multi Media/Control Flow Paths • Relieve Host CPU Load • Release API for Integration • OS : Linux and Windows • Integrates in Asterisk® and FreeSWITCH® • Support distributed or intergrated Application Codec Support • G.711 • GSM-FR • G.722 • GMS-EFR • G.722.1 • AMR • G.726 • AMR-WB (G.722.2) • G.729AB • iLBC 1 Except for AMR and ANR-WB Target Applications Hardware installation Manual OpenVox Communication Co. Limited. URL: www.openvox.cn Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049 6 •Hosted VoIP GateWay •Conferencing Server •IVR Server •Distributed Office PBX •Call Centers Chapter 2 Hardware Specification Dimensions •Includes Low Profile PCI Short Form Factor in 2U Chassis • 64.1x119..8mm (PCB) Interface •PCI :32bit/33MHz •PCIe: x1 •10/100/1000 BASE-T RJ45 Power Requirments •PCI: 2.5A @3.3V Or •PCIe: 0.3A @3.3V; 0.6A @12V Operating Temperature Range •0 – 50 °C Humidity •10 TO 90% NON-CONDENSING Hardware and Software Requirement •PC with PCI/PCIe Slot •Windows/Linux in Host Chapter 3 Hardware Architecture Hardware installation Manual OpenVox Communication Co. Limited. URL: www.openvox.cn Tel: +86-755-83535…
Text truncated - open the document above for the full version.
OpenVox Communication Co., Ltd. Authorization Letter Number: CF101 Version: V01 Date: 01-02-2010 We, (the approval holder) Company name OpenVox Communication Co., Ltd. Addresss F/3, Building No. 127, Jindi Industrial Zone, Futian District, City Shenzhen, Guangdong Country China declare that the following representative (agent): Name (person) Daniel Zhu Company name Anbotek Compliance Laboratory Limited Addresss 1/F, 1 /Build, SEC Industrial Park, No. 4 Qianhai Road, Nanshan District City Shenzhen Country China is hereby authorized to apply the following equipment for certification on our behalf: Product Description Transcoding Cards Type or Model(s) V100 Tradename or Brand(s) N.A. We also authorize Teleconformity (Mr. M. Koop, Rietven 31, 7534NH, The Netherlands) to apply and sign for this application. Attestation: City and Country: Date: Name: (this must be a person) Function: Signature: (or official company stamp) SHENZHEN, CHINA 2011-8-15 Carson Wang Deputy General Manager
[company header optional] FCC Confidentiality Request Number: CF303 Version: V01 Date: 01-02-2010 To the FCC and FCC TCB handling this application for certification Pursuant to 47 CFR Section 0.459(a) & (b), we, (the applicant / grantee) Company name OpenVox Communication Co., Ltd. Addresss F/3, Building No. 127, Jindi Industrial Zone, Futian District, City Shenzhen, Guangdong Country China request non-disclosure and confidential treatment for our certification under: Grantee Code Product Number FCC ID: ZXD V100 of the following materials submitted within this certification application: (please cross what is applicable, or add other documents) √ Schematics Diagrams √ Block Diagrams √ Circuit Description User Manual Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. We understand that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. Attestation: City and Country: Date: Name: (this must be a person) Function: Signature: (or official company stamp) SHENZHEN, CHINA 2011-8-15 Carson Wang Deputy General Manager
Page 27 o f 30 Anbotek Compliance Laboratory Limited Report No. 201108660F Figure 1 The EUT-Front View Figure 2 The EUT-Back View Page 28 o f 30 Anbotek Compliance Laboratory Limited Report No. 201108660F Figure 3 The EUT-Side View
The proposed Label Location on EUT Proposed FCC ID Label Location Proposed Label Location on EUT The EUT-Back View/Proposed FCC ID Label Location
FCC ID Label Sample for FCC ID: ZXDV100 FCC ID: ZXDV100
Page 28 o f 29 Anbotek Compliance Laboratory Limited Report No. 201108660F Figure 4 The EUT-Inside View Figure 5 Part of the EUT- Front View Figure 6 Page 29 o f 29 Anbotek Compliance Laboratory Limited Report No. 201108660F Part of the EUT- Back View
Page 1 o f 30 Anbotek Compliance Laboratory Limited Report No. 201108660F FCC PART 15B TEST REPORT On Behalf of OpenVox Communication Co., Ltd. Transcoding Cards Model No.: V100 Prepared for : OpenVox Communication Co., Ltd. Address : F/3, Building No. 127, Jindi Industrial Zone, Futian District, Shenzhen, Guangdong, China Prepared By : Anbotek Compliance Laboratory Limited Address : 1/F, 1/Build, SEC Industrial Park, No. 4 Qianhai Road, Nanshan District, Shenzhen, 518054, China Tel: (86) 755-26014771 Fax: (86) 755-26014772 Report Number : 201108660F Date of Test : Aug. 15~19, 2011 Date of Report : Aug. 22, 2011 Page 2 o f 30 Anbotek Compliance Laboratory Limited Report No. 201108660F TABLE OF CHONTENTS Description Page Test Report Verification 1. GENERAL INFORMATION ............................................................................................................... 4 1.1. Description of Device (EUT) ..........................................................................................................................4 1.2. Auxiliary Equipment Used during Test ..........................................................................................................5 1.3. Description of Test Facility.............................................................................................................................6 1.4. Measurement Uncertainty ...............................................................................................................................6 1.5. Test Summary .................................................................................................................................................6 2. POWER LINE CONDUCTED MEASUREMENT ............................................................................ 7 2.1. Test Equipment ...............................................................................................................................................7 2.2. Block Diagram of Test Setup ..........................................................................................................................7 2.3. Power Line Conducted Emission Measurement Limits (FCC Part 15 Subpart B Class B) ............................7 2.4. Configuration of EUT on Measurement..........................................................................................................8 2.5. Operating Condition of EUT...........................................................................................................................8 2.6. Test Procedure.................................................................................................................................................8 2.7. Power Line Conducted Emission Measurement Results.................................................................................8 3. RADIATED EMISSION MEASUREMENT..................................................................................... 13 3.1. Test Equipment .............................................................................................................................................13 3.2. Block Diagram of Test Setup ........................................................................................................................13 3.3. Radiated Emission Limit (Subpart B Class B) ..............................................................................................14 3.4. EUT Configuration on Measurement ............................................................................................................14 3.5. Operating Condition of EUT.........................................................................................................................14 3.6. Test Procedure...............................................................................................................................................14 3.7. Radiated Emission Measurement Results .....................................................................................................15 4. PHOTOGRAPH ................................................................................................................................... 24 4.1. Photo of Power Line Conducted Emission Test............................................................................................24 4.2. Photo of Radiated Emission Test ..................................................................................................................25 APPENDIX I (Photos of EUT) (4 Pages) Page 3 o f 30 Anbotek Compliance Laboratory Limited Report No. 201108660F TEST REPORT VERIFICATION Applicant : OpenVox Communication Co., Ltd. Manufacturer : OpenVox Communication Co., Ltd. EUT : Transcoding Cards Model No. : V100 Rating : DC 3.3V or DC 12V Trade Mark : N.A. Measurement Procedure Used: FCC Rules and Regulations Part 15 Subpart B 2010 & FCC / ANSI C63.4-2009 The device described above is tested by Anbotek Compliance Laboratory Limited To determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15 Subpart B Class B limits both radiated and conducted emissions. The measurement results are contained in this test report and Anbotek Compliance Laboratory Limited Is assumed full responsibility for the accuracy and completeness of these measurements. Also, this report shows that the Equipment Under Test (EUT) is to be technically compliant with the FCC requirements. This report applies to above tested sample only. This report shall not be reproduced in part without written approval of Anbotek Compliance Laboratory Limited Date of Test : Aug. 15~19, 2011 Prepared by : (Engineer/ Well Wang) Reviewer : (Project Manager/ Coco Xiang) Approved & Authorized Signer : (Manager/ Henry Yang) Page 4 o f 30 Anbotek Compliance Laboratory Limited Report No. 201108660F 1. GENERAL INFORMATION 1.1. Description of Device (EUT) Description : Transcoding Cards Model Number : V100 Test Power Suppl…
Text truncated - open the document above for the full version.
Page 24 o f 30 Anbotek Compliance Laboratory Limited Report No. 201108660F 4. PHOTOGRAPH 4.1. Photo of Power Line Conducted Emission Test Page 25 o f 30 Anbotek Compliance Laboratory Limited Report No. 201108660F 4.2. Photo of Radiated Emission Test
Rietven 31 · Enschede, Overyssel · Netherlands
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |
Digital Voice Board
Equipment Class
JBP - Part 15 Class B Computing Device PeripheralTranscoding Cards
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral