FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TSI Incorporated/
  3. 2A22JOTSTATION

2A22JOTSTATIONTSI OmniTrak Smart Station

TSI Incorporated
TSI OmniTrak Smart Station - FCC ID 2A22JOTSTATION - TSI Incorporated
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 10, 2023
Application Purpose
Original Equipment
Date of Application
Jul 10, 2023
Equipment Note
TSI OmniTrak Smart Station
Frequency Range
2412.00000000 - 2462.00000000
Company
TSI Incorporated
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Smart Station Model 7590 What’s Included in the Box ▪ Device ▪ USB-C Cable Operation Instructions 1. Power On: On the right side of the Smart Station, hold circle power button down for 3 seconds. 2. PowerOff: On the right side of the Smart Station, hold circle power button down for 2 seconds. Two options then pop-up on the screen to either Power Off or Restart. 3. Charging: Plug USB-C cable into bottom of device and then into power source 4. Connecting to a Module: Power on module by holding down the circle on the left for 1 second. A blue LED light will start to blink indicating Bluetooth® is on. - The module will appear in the list on the Smart Station. If not, hit Refresh. - Press desired module on screen to connect to Smart Station. A green check mark indicates a successful connection. - Press Done Now you’re ready to take measurements. The OmniTrak™ Smart Station can be used in conjunction with any OmniTrak™ Module to provide immediate feedback as to the conditions in the immediate area. Take measurements, create reports, and analyze data provided to help improve conditions. This instrument is a handheld device, not to be worn on the body, or near an individual’s head. Dispose of battery in accordance with local rules and regulations. Smart Station Model 7590 SpecificationsSpecifications AC and DC Power Requirements AC/DC Power SupplyAC/DC Power Supply 100 to 240 VAC, 100 to 240 VAC, 50/60 Hz, 0.3A50/60 Hz, 0.3A Device Input PowerDevice Input Power 5 VDC,10W 5 VDC,10W 2A, 10W2A, 10W Environmental/Installation Requirements Maximum AltitudeMaximum Altitude3000 meters (10,000 feet)3000 meters (10,000 feet) Pollution DegreePollution Degree22 Installation CategoryInstallation CategoryII Operating TemperatureOperating Temperature5°C to 40°C5°C to 40°C Storage TemperatureStorage Temperature-20°C to 60°C-20°C to 60°C HumidityHumidity 0% - 95% 0% - 95% (non-condensing)(non-condensing) Compliance FCC ID: 2A22JOTSTATIONFCC ID: 2A22JOTSTATIONIC ID: 28101-OTSTATIONIC ID: 28101-OTSTATION This device complies with part 15 of the FCC Rules. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 1. This device may not cause harmful interference. 2. This device must accept any interference 2. This device must accept any interference received, including interference that may received, including interference that may cause undesired operation.cause undesired operation. Per FCC 15.21 Changes or modifications not expressly Per FCC 15.21 Changes or modifications not expressly approved by TSI will void the product warranty and may approved by TSI will void the product warranty and may void the user’s authority to operate the equipment.void the user’s authority to operate the equipment. This device contains license-exempt transmitter(s)/This device contains license-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science receiver(s) that comply with Innovation, Science and Economic Development Canada’s license- and Economic Development Canada’s license- exempt RSS(s). Operation is subject to the exempt RSS(s). Operation is subject to the following two conditions:following two conditions: 1. This device may not cause interference.1. This device may not cause interference. 2. This device must accept any interference, including 2. This device must accept any interference, including interference that may cause undesired operation interference that may cause undesired operation of the device.of the device. Le présent appareil est conforme aux CNR d’Industrie Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux de licence. L’exploitation est autorisée aux deux conditions suivantes: conditions suivantes: 1. l’appareil ne doit pas produire de brouillage, et 1. l’appareil ne doit pas produire de brouillage, et 2. l’utilisateur de l’appareil doit accepter tout brouillage 2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.susceptible d’en compromettre le fonctionnement. To satisfy RF exposure requirements, this device and its To satisfy RF exposure requirements, this device and its antenna may be operated near a persons body and the antenna may be operated near a persons body and the extremities, but must be operated with a separation distance extremities, but must be operated with a separation distance of at least 20 cm from all person’s head.of at least 20 cm from all person’s head. Pour satisfaire aux exigences d’exposition RF, cet appareil Pour satisfaire aux exigences d’exposition RF, cet appareil et son antenne peuvent être utilisés à proximité du corps et et son antenne peuvent être utilisés à proximité du corps et des extrémités d’une personne, mais doivent être utilisés des extrémités d’une personne, mais doivent être utilisés avec une distance de séparation d’au moins 20 cm de avec une distance de séparation d’au moins 20 cm de la tête de toute personne. la tête de toute personne. 4420176118 TSI Incorporated - Visit our website www.tsi.com for more information. USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99 Germany Tel: +49 241 523030 India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388 Printed in U.S.A.P/N 5003016 Rev B ©2023 TSI Incorporated Specifications are subject to change without notice. Wi-Fi is a registered trademark of Wi-Fi Alliance®. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. TSI, and the TSI logo are registered trademarks of TSI Incorporated in the United States and may be protected under other country’s trademark registrat…

Text truncated - open the document above for the full version.

External Photos

7590-00 External Photos

ID Label/Location Info

7590-00 Label and Location

Internal Photos

7590-00 Internal Photos

RF Exposure Info

APPENDIX A: SAR TEST PLOTS A1 ELEMENT DUT: 2A22JOTSTATION/28101- OTSTATION; Type: Portable Handset; Serial: 00070 Communication System: UID:10415 - AAA, WLAN; MAIA: Y; Frequency: 2437.0 MHz Medium: 2450 Head; Medium parameters used: f = 2437.0 MHz; cond = 1.81 S/m; perm = 39.0; density = 1000 kg/m3 Phantom Section: Flat; Space: 0.00 mm Test Date: 03/28/2023; Ambient Temp: 20.5°C; Tissue Temp: 20.9°C Probe: EX3DV4 - SN7570; ConvF:(7.55,7.55,7.55); Calibrated: 2023-01-11 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1558; Calibrated: 2023-01-17 Phantom: Twin-SAM V8.0; Serial: 2060 Measurement SW: DASY Module SAR V16.2.0.1425 Mode: IEEE 802.11b, 22 MHz Bandwidth, Body SAR, Left Edge, Ch. 6, 1 Mbps Area Scan (40.0 x 220.0): Measurement grid: dx=5.0 mm, dy=10.0 mm Zoom Scan (30.0 x 30.0 x 30.0): Measurement grid: dx=5.0 mm, dy=5.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Reference Value = 0.22 W/kg; Power Drift = 0.02 dB Peak SAR (extrapolated) = 0.435 W/kg SAR(1 g) = 0.211 W/kg; SAR(10 g) = 0.105 W/kg Smallest distance from peaks to all points 3 dB below is 11.5 mm Ratio of SAR at M2 to SAR at M1 = 78.0 % A2 ELEMENT DUT: 2A22JOTSTATION/28101- OTSTATION; Type: Portable Handset; Serial: 00070 Communication System: UID:10670 - AAA, Bluetooth; MAIA: Y; Frequency: 2480.0 MHz Medium: 2450 Head; Medium parameters used: f = 2480.0 MHz; cond = 1.85 S/m; perm = 38.8; density = 1000 kg/m3 Phantom Section: Flat; Space: 0.00 mm Test Date: 04/05/2023; Ambient Temp: 22.9°C; Tissue Temp: 22.4°C Probe: EX3DV4 - SN7570; ConvF:(7.55,7.55,7.55); Calibrated: 2023-01-11 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1558; Calibrated: 2023-01-17 Phantom: Twin-SAM V8.0; Serial: 2060 Measurement SW: DASY Module SAR V16.2.0.1425 Mode: Bluetooth Low Energy, Body SAR, Ch. 39, 1Mbps, Left Edge Area Scan (70.0 x 220.0): Measurement grid: dx=5.0 mm, dy=10.0 mm Zoom Scan (30.0 x 30.0 x 30.0): Measurement grid: dx=5.0 mm, dy=5.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Reference Value = 0.00 W/kg; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.004 W/kg SAR(1 g) = 0.000 W/kg; SAR(10 g) = 0.000 W/kg Smallest distance from peaks to all points 3 dB below is 2.0 mm Ratio of SAR at M2 to SAR at M1 = 65.6 %

RF Exposure Info

APPENDIX B: SAR DIPOLE VERIFICATION PLOTS B1 ELEMENT DUT: Dipole 2450.0 MHz; Type: D2450V2 - SN981 Communication System: UID: 0, CW; Frequency: 2450.0 MHz Medium: 2450 Head; Medium parameters used: f = 2450.0 MHz; cond = 1.82 S/m; perm = 39.0; density = 1000 kg/m3 Phantom Section: Flat; Space: 10 mm Test Date: 03/28/2023; Ambient Temp: 20.5°C; Tissue Temp: 20.9°C Probe: EX3DV4 - SN7570; ConvF:(7.55,7.55,7.55); Calibrated: 2023-01-11 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1558; Calibrated: 2023-01-17 Phantom: Twin-SAM V8.0; Serial: 2060 Measurement SW: DASY Module SAR V16.2.0.1425 2450 MHz System Verification at 20 dBm (100 mW) Area Scan (40.0 x 80.0): Measurement grid: dx=10.0 mm, dy=10.0 mm Zoom Scan (30.0 x 30.0 x 30.0): Measurement grid: dx=5.0 mm, dy=5.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Peak SAR (extrapolated) = 10.3 W/kg SAR(1 g) = 5.06 W/kg; SAR(10 g) = 2.36 W/kg Deviation (1 g) = -6.12 %; Deviation (10 g) = -7.09%; B2 ELEMENT DUT: Dipole 2450.0 MHz; Type: D2450V2 - SN981 Communication System: UID: 0, CW; Frequency: 2450.0 MHz Medium: 2450 Head; Medium parameters used: f = 2450.0 MHz; cond = 1.83 S/m; perm = 38.8; density = 1000 kg/m3 Phantom Section: Flat; Space: 10 mm Test Date: 04/05/2023; Ambient Temp: 22.9°C; Tissue Temp: 22.4°C Probe: EX3DV4 - SN7570; ConvF:(7.55,7.55,7.55); Calibrated: 2023-01-11 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1558; Calibrated: 2023-01-17 Phantom: Twin-SAM V8.0; Serial: 2060 Measurement SW: DASY Module SAR V16.2.0.1425 2450 MHz System Verification at 20 dBm (100 mW) Area Scan (40.0 x 80.0): Measurement grid: dx=10.0 mm, dy=10.0 mm Zoom Scan (30.0 x 30.0 x 30.0): Measurement grid: dx=5.0 mm, dy=5.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Peak SAR (extrapolated) = 10.2 W/kg SAR(1 g) = 4.95 W/kg; SAR(10 g) = 2.31 W/kg Deviation (1 g) = -8.16%; Deviation (10 g) = -9.06%;

RF Exposure Info

APPENDIX C: PROBE AND DIPOLE CALIBRATION CERTIFICATES Object: Date Issued: Page 1 of 4 D2450V2 – SN: 981 11/24/2022 Certification of Calibration Object D2450V2 – SN: 981 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extension Calibration date: 11/24/2022 Description: SAR Validation Dipole at 2450 MHz. Calibration Equipment used: Measurement Uncertainty = ±23% (k=2) Name Function Signature Calibrated By: Tho Tong Test Engineer Approved By: Kaitlin O’Keefe Senior Technical Manager Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Agilent N5182A MXG Vector Signal Generator 1/12/2022 Annual 1/12/2023 MY47420837 Amplifier Research 15S1G6 Amplifier CBT N/A CBT 343971 Anritsu MA2411B Pulse Power Sensor 3/28/2022 Annual 3/28/2023 1339007 Anritsu MA2411B Pulse Power Sensor 3/2/2022 Annual 3/2/2023 1126066 Anritsu ML2496A Power Meter 3/31/2022 Annual 3/31/2023 1138001 Anritsu ML2496A Power Meter 3/17/2022 Annual 3/17/2023 941001 Control Company 4040 Therm./ Clock/ Humidity Monitor 3/12/2021 Biennial 3/12/2023 210202100 Control Company 4352 Ultra Long Stem Thermometer 1/21/2022 Annual 1/21/2023 160508097 Control Company 4352 Long Stem Thermometer 9/10/2021 Biennial 9/10/2023 210774678 Mini-Circuits BW-N20W5+ DC to 18 GHz Precision Fixed 20 dB Attenuator CBT N/A CBT N/A Mini-Circuits NLP-2950+ Low Pass Filter DC to 2700 MHz CBT N/A CBT N/A Narda 4772-3 Attenuator (3dB) CBT N/A CBT 9406 Pasternack PE5011-1 Torque Wrench 12/21/2021 Biennial 12/21/2023 82475 Mini-Circuits ZHDC-16-63-S+ Coupler CBT N/A CBT N/A Rohde & Schwarz ZNLE6 Vector Network Analyzer 10/21/2022 Annual 10/21/2023 101307 SPEAG DAK-3.5 Dielectric Assessment Kit 5/12/2022 Annual 5/12/2023 1070 Keysight Technologies 85033E Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) 6/21/2022 Annual 6/21/2023 MY53402352 SPEAG EX3DV4 SAR Probe 2/21/2022 Annual 2/21/2023 7488 SPEAG DAE4 Dasy Data Acquisition Electronics 2/23/2022 Annual 2/23/2023 1415 SPEAG EX3DV4 SAR Probe 6/16/2022 Annual 6/16/2023 7409 SPEAG DAE4 Dasy Data Acquisition Electronics 6/14/2022 Annual 6/14/2023 1334 ELEMENT MATERIALS TECHNOLOGY (formerly PCTEST) 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.element.com Object: Date Issued: Page 2 of 4 D2450V2 – SN: 981 11/24/2022 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements: 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ω from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 2-year calibration period from the calibration date: Calibration Date Extension Date Certificate Electrical Delay (ns) Certificate SAR Target Head (1g) W/kg @ 20.0 dBm Measured Head SAR (1g) W/kg @ 20.0 dBm Deviation 1g (%) Certificate SAR Target Head (10g) W/kg @ 20.0 dBm Measured Head SAR (10g) W/kg @ 20.0 dBm Deviation 10g (%) Certificate Impedance Head (Ohm) Real Measured Impedance Head (Ohm) Real Difference (Ohm) Real Certificate Impedance Head (Ohm) Imaginary Measured Impedance Head (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Head (dB) Measured Return Loss Head (dB) Deviation (%) PASS/FAIL 11/25/2021 11/24/2022 1.163 5.39 5.22 -3.15% 2.54 2.43 -4.33% 53.8 51.4 2.4 5.8 4.1 1.7 -23.6 -27.4 -16.00% PASS Calibration Date Extension Date Certificate Electrical Delay (ns) Certificate SAR Target Body (1g) W/kg @ 20.0 dBm Measured Body SAR (1g) W/kg @ 20.0 dBm Deviation 1g (%) Certificate SAR Target Body (10g) W/kg @ 20.0 dBm Measured Body SAR (10g) W/kg @ 20.0 dBm Deviation 10g (%) Certificate Impedance Body (Ohm) Real Measured Impedance Body (Ohm) Real Difference (Ohm) Real Certificate Impedance Body (Ohm) Imaginary Measured Impedance Body (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Body (dB) Measured Return Loss Body (dB) Deviation (%) PASS/FAIL 11/25/2021 11/24/2022 1.163 5.03 4.88 -2.98% 2.37 2.27 -4.22% 50.4 47.9 2.5 8.5 4.6 3.9 -21.5 -25.7 -19.70% PASS Object: Date Issued: Page 3 of 4 D2450V2 – SN: 981 11/24/2022 Impedance & Return-Loss Measurement Plot for Head TSL Object: Date Issued: Page 4 of 4 D2450V2 – SN: 981 11/24/2022 Impedance & Return-Loss Measurement Plot for Body TSL

RF Exposure Info

FCC ID: IC: 2A22JOTSTATION 28101- OTSTATION SAR EVALUATION REPORT Approved by: Technical Manager DUT Type/Apparatus/Device: Portable Handheld Device APPENDIX D: Page 1 of 2 APPENDIX D: SAR TISSUE SPECIFICATIONS Measurement Procedure for Tissue verification: 1) The network analyzer and probe system was configured and calibrated. 2) The probe was immersed in the tissue. The tissue was placed in a nonmetallic container. Trapped air bubbles beneath the flange were minimized by placing the probe at a slight angle. 3) The complex admittance with respect to the probe aperture was measured 4) The complex relative permittivity ε ’ can be calculated from the below equation (Pournaropoulos and Misra): where Y is the admittance of the probe in contact with the sample, the primed and unprimed coordinates refer to source and observation points, respectively, ,  is the angular frequency, and . Figure D-1 Note: Liquid recipes are proprietary SPEAG. Since the composition is approximate to the actual liquids utilized, the manufacturer tissue-equivalent liquid data sheets are provided below.         b a b a rr ddd r rj ab j Y      0 2/1 0 ' 0 2 0 )(exp cos ln 2     cos2 222 r 1j FCC ID: IC: 2A22JOTSTATION 28101- OTSTATION SAR EVALUATION REPORT Approved by: Technical Manager DUT Type/Apparatus/Device: Portable Handheld Device APPENDIX D: Page 2 of 2 Figure D-2 600 – 6000 MHz Head Tissue Equivalent Matter

RF Exposure Info

FCC ID: IC: 2A22JOTSTATION 28101- OTSTATION SAR EVALUATION REPORT Approved by: Technical Manager DUT Type/Apparatus/Device: Portable Handheld Device APPENDIX F: Page 1 of 4 APPENDIX F: DUT ANTENNA DIAGRAM & SAR TEST SETUP PHOTOGRAPHS FCC ID: IC: 2A22JOTSTATION 28101- OTSTATION SAR EVALUATION REPORT Approved by: Technical Manager DUT Type/Apparatus/Device: Portable Handheld Device APPENDIX F: Page 2 of 4 Note: Exact antenna dimensions and separation distances are shown in the Technical Descriptions . Figure F-1 DUT Antenna Locations FCC ID: IC: 2A22JOTSTATION 28101- OTSTATION SAR EVALUATION REPORT Approved by: Technical Manager DUT Type/Apparatus/Device: Portable Handheld Device APPENDIX F: Page 3 of 4 SAR Test Setup Photo 1 – Back Side at 0mm SAR Test Setup Photo 2 – Front Side at 0mm FCC ID: IC: 2A22JOTSTATION 28101- OTSTATION SAR EVALUATION REPORT Approved by: Technical Manager DUT Type/Apparatus/Device: Portable Handheld Device APPENDIX F: Page 4 of 4 SAR Test Setup Photo 3 – Top Edge at 0mm SAR Test Setup Photo 4 – Left Edge at 0mm

RF Exposure Info

FCC ID: IC: 2A22JOTSTATION 28101- OTSTATION SAR EVALUATION REPORT Approved by: Technical Manager DUT Type/Apparatus/Device: Portable Handheld Device APPENDIX E: Page 1 of 1 APPENDIX E: SAR SYSTEM VALIDATION Per FCC KDB Publication 865664 D02v01r02, SAR system validation status should be documented to confirm measurement accuracy. The SAR systems (including SAR probes, system components and software versions) used for this device were validated against its performance specifications prior to the SAR measurements. Reference dipoles were used with the required tissue- equivalent media for system validation, according to the procedures outlined in FCC KDB Publication 865664 D01v01r04 and IEEE 1528-2013. Since SAR probe calibrations are frequency dependent, each probe calibration point was validated at a frequency within the valid frequency range of the probe calibration point, using the system that normally operates with the probe for routine SAR measurements and according to the required tissue-equivalent media. A tabulated summary of the system validation status including the validation date(s), measurement frequencies, SAR probes and tissue dielectric parameters has been included. Table E-1 SAR System Validation Summary NOTE: The probes have been calibrated for both CW and modulated signals. Modulations in the table above represent test configurations for which the measurement system has been validated per FCC KDB Publication 865664 D01v01r04 for scenarios when CW probe calibrations are used with other signal types. SAR systems were validated for modulated signals with a periodic duty cycle, such as GMSK, or with a high peak to average ratio (>5 dB), such as OFDM according to FCC KDB Publication 865664 D01v01r04. SENSITIVIT Y PROBE LINEARITY PROBE ISOTROPY MOD. TYPE DUTY FACTOR PAR O245002/08/2023757015582450Head1.83938.743PASSPASSPASSOFDM/TDDPASSPASS Perm. (εr) CW VALIDATIONMOD. VALIDATION Cond. (σ) SAR System Freq. (MHz) Da te Probe SN DAEProbe Ca l Point

RF Exposure Info

FCC ID: 2A22JOTSTATION IC: 28101- OTSTATION SAR EVALUATION REPORT Approved by: Technical Manager Document S/N: 1M2303240040-01-R2.2A22J DUT Type/Apparatus/Device: Portable Handheld Device Page 1 of 31 REV 22.0 03/30/2022 Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from Element. If you have any questions or have an enquiry about obtaining additional rights to this report or assembly of contents thereof, please contact [email protected]. Applicant Name: Date of Testing: TSI Incorporated 03/28/23 – 04/05/23 500 Cardigan Road Test Site/Location: Shoreview, Minnesota 55126 USA Element Washington DC LLC, Columbia, MD, USA Lab Code: 2451B Document Serial No.: 1M2303240040-01-R2.2A22J FCC ID: IC: 2A22JOTSTATION 28101- OTSTATION APPLICANT: TSI INCORPORATED DUT Type/Apparatus/Device: Portable Handheld Device Application Type: Certification FCC Rule Part(s): IC Specification(s): Additional Standard(s) Radio Equipment Type(s): CFR §2.1093 RSS-102 Issue 5 (March 2015), Health Canada Safety Code 6 IEC/IEEE 62209-1528:2020 Bluetooth, and Wi-Fi Device Model(s)/HVIN: TSI SMART STATION Note: This revised Test Report (S/N: 1M2303240040-01-R2.2A22J) supersedes and replaces the previously issued test report on the same subject device for the same type of testing as indicated. Please discard or destroy the previously issued test report(s) and dispose of it accordingly. This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE C95.1-1992 and has been tested in accordance with the measurement procedures specified in Section 1.9 of this report; for North American frequency bands only. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Test results reported herein relate only to the item(s) tested. The SAR Tick is an initiative of the Mobile & Wireless Forum (MWF). While a product may be considered eligible, use of the SAR Tick logo requires an agreement with the MWF. Further details can be obtained by emailing: [email protected]. 1g Body (W/kg) 10g Extremity (W/kg) DTS2.4 GHz WLAN2412 - 2462 MHz0.320.16 DSS/DTSBluetooth Low Energy2402 - 2480 MHz< 0.1< 0.1 0.360.17 Equipment Class Simultaneous SAR per KDB 690783 D01v01r03: Band & ModeTx Frequency SAR ELEMENT Washington DC LLC (formerly PCTEST) 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.element.com SAR EVALUATION REPORT FCC ID: 2A22JOTSTATION IC: 28101- OTSTATION SAR EVALUATION REPORT Approved by: Technical Manager Document S/N: 1M2303240040-01-R2.2A22J DUT Type/Apparatus/Device: Portable Handheld Device Page 2 of 31 REV 22.0 03/30/2022 Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from Element. If you have any questions or have an enquiry about obtaining additional rights to this report or assembly of contents thereof, please contact [email protected]. T A B L E O F C O N T E N T S 1 DEVICE UNDER TEST .................................................................................................................................3 2 INTRODUCTION ...........................................................................................................................................7 3 SAR MEASUREMENT SETUP .....................................................................................................................8 4 DOSIMETRIC ASSESSMENT ................................................................................................................... 10 5 DASY E-FIELD PROBE SYSTEM.............................................................................................................. 11 6 TEST CONFIGURATION POSITIONS....................................................................................................... 12 7 RF EXPOSURE LIMITS ............................................................................................................................. 13 8 MEASUREMENT PROCEDURES ............................................................................................................. 14 9 RF CONDUCTED POWERS ...................................................................................................................... 16 10 SYSTEM VERIFICATION ........................................................................................................................... 19 11 SAR DATA SUMMARY .............................................................................................................................. 21 12 FCC MULTI-TX AND ANTENNA SAR CONSIDERATIONS ...................................................................... 23 13 SAR MEASUREMENT VARIABILITY ........................................................................................................ 25 14 EQUIPMENT LIST ...................................................................................................................................... 26 15 MEASUREMENT UNCERTAINTIES.......................................................................................................... 27 16 CONCLUSION ............................................................................................................................................ 29 17 REFERENCES ..................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

This report must not be used to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This Report shall not be reproduced, except in full without written approval of the laboratory. TSI, Incorporated TSI Inc. OmniTrak FCC 15.207:2023, FCC 15.247:2023 RSS-247 Issue 2:2017, RSS-Gen Issue 5:2018+A1:2019+A2:2021 Bluetooth Radio Report: TSIN0196.3 Rev. 1, Issue Date: June 29, 2023 TABLE OF CONTENTS 2023.04.17 Section Page Number Certificate of Test ............................................................................................ 3 Revision History .............................................................................................. 5 Accreditations .................................................................................................. 6 Facilities .......................................................................................................... 7 Measurement Uncertainty ............................................................................... 8 Test Setup Block Diagrams ............................................................................. 9 Product Description ......................................................................................... 12 Power Settings and Antenna Information ........................................................ 13 Configurations ................................................................................................. 14 Modifications ................................................................................................... 16 Powerline Conducted Emissions ..................................................................... 17 Duty Cycle ....................................................................................................... 22 DTS Bandwidth (6 dB) .................................................................................... 36 Occupied Bandwidth (99%) ............................................................................. 44 Output Power .................................................................................................. 52 Equivalent Isotropic Radiated Power (EIRP) ................................................... 60 Power Spectral Density ................................................................................... 68 Band Edge Compliance .................................................................................. 76 Spurious Conducted Emissions ...................................................................... 82 Spurious Radiated Emissions ......................................................................... 102 End of Report .................................................................................................. 110 Report No. TSIN0196.3 Rev 12/110 CERTIFICATE OF TEST 2022.04.01 Product compliance is the responsibility of the client; therefore, the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. This report reflects only those tests from the referenced standards shown in the certificate of test. It does not include inspection or verification of labels, identification, marking or user information. As indicated in the Statement of Work sent with the quotation, Element’s standard process is to always use the latest published version of the test methods even when earlier versions are cited in the test specification. Issuance of a purchase order was de facto acceptance of this approach. Otherwise, the client would have advised Element in writing of the specific version of the test methods they wanted applied to the subject testing. Last Date of Test: May 25, 2023 TSI, Incorporated EUT: TSI Inc. OmniTrak Radio Equipment Testing Standards Specification Method FCC 15.207:2023 ANSI C63.10:2013, FCC KDB 558074 v05r02:2019 FCC 15.247:2023 RSS-247 Issue 2:2017 RSS-Gen Issue 5:2018+A1:2019+A2:2021 Results Test Description Result FCC Section(s) RSS Section(s) ANSI C63.10 Section(s) Comments Powerline Conducted Emissions Pass 15.207 RSS-Gen 8.8 6.2 Duty Cycle Pass KDB 558074 - 6.0 RSS-Gen 3.2 11.6 DTS Bandwidth (6 dB) Pass 15.247(a)(2), KDB 558074 - 8.2 RSS-247 5.2(a) 11.8.2 Occupied Bandwidth (99%) Pass KDB 558074 - 2.1 RSS-Gen 6.7 6.9.3 Output Power Pass 15.247(b)(3), KDB 558074 - 8.3.1 RSS-247 5.4(d, f), RSS- Gen 6.12 11.9.1.1 Equivalent Isotropic Radiated Power Pass 15.247(b)(3), KDB 558074 - 8.3.1 RSS-247 5.4(d, f), RSS- Gen…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Daniel Happe(General Counsel, Secretary and VP - Export/Import)
[email protected]6514903882Fax: 6517655202

Test Firm

Element Materials Technology Minneapolis - BrooklyRenee Walker
[email protected]503 844 4066

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz17.00 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. The SAR of the DTS equipment has been evaluated in conjunction with the grantee radio equipment family of products, TSI OmniTrak Modules. The highest reported SAR for body-worn accessory, extremity (hand), and simultaneous transmission exposure conditions are 0.32 W/kg, 0.16 W/kg, and 0.36 W/kg, respectively.

Other Applications from TSI Incorporated

7591-01, 7591-02, 7591-04 - FCC ID 2A22JOTMODULES - TSI Incorporated
2A22JOTMODULES

7591-01, 7591-02, 7591-04

Jul 13, 2023

Equipment Class

DTS - Digital Transmission System