Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shenzhen Digitizing Fluid Technology Co., Ltd Date:2023-09-15 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: Request of Confidentiality for FCC ID: 2A26IDFT-SD101 To Whom it may concern: Pursuant to sections 0.457 and 0.459 of Commissionβs Rules (CFR 47), and Section 552(b)(4) of the Freedom of Information Act, Shenzhen Digitizing Fluid Technology Co., Ltd hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA04-1705. This provision will give Shenzhen Digitizing Fluid Technology Co., Ltd temporary confidentiality of commercially sensitive information prior to product release. The requested Permanent and Short-Term Confidential exhibits are listed as follows: PERMANENT AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description PERMANENT 1 Block Diagram 2 Operational Description 3 Schematics 4 Tune-up Tolerance Procedure SHORT-TERM 5 External Photos 6 Internal Photos 7 Test-Setup Photos 8 User Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Signatory: Contact name: Ti Peng Title: CEO Tel: 18250870990 Email: [email protected] Company name: Shenzhen Digitizing Fluid Technology Co., Ltd
FCC ID: 2A26IDFT-SD101 External Photos 1. EUT front view 2. EUT rear view 3. EUT left side view 4. EUT right side view 5. EUT top view 6. EUT bottom view 7. EUT bottom view
1γLabel 2γlocation(on the back)
FCC ID: 2A26IDFT-SD101 Internal Photos 1. EUT uncover view 2. Antenna view Bluetooth/2.4G WIFI Antenna
MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23060377S01 Annex C Plots of System Performance Check Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2023.8.19 System Check_2450MHz_Head Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: HSL_2450 Medium parameters used: f = 2450 MHz; Ο = 1.828 S/m; Ξ΅ r = 38.811; Ο = 1000 kg/m 3 Ambient TemperatureοΌ23.2 Β°C; Liquid TemperatureοΌ22.1 Β°C DASY5 Configuration: - Probe: EX3DV4 - SN3809; ConvF(7.42, 7.42, 7.42) @ 2450 MHz; Calibrated: 2022.12.10 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE3 Sn373; Calibrated: 2022.12.28 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) CW2450/Area Scan (81x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 14.4 W/kg CW2450/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 96.37 V/m; Power Drift = 0.08 dB Peak SAR (extrapolated) = 27.5 W/kg SAR(1 g) = 12.32 W/kg; SAR(10 g) = 5.74 W/kg Maximum value of SAR (measured) = 13.9 W/kg 0 dB = 13.9 W/kg = 11.43 dBW/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23060377S01
MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23060377S01 Annex D Plots of Maximum SAR Test Results Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2023.8.19 WLAN2.4GHz_802.11b 1Mbps_Front Side_0mm_Ch1 Communication System: UID 0, WLAN 2.4GHz 802.11b (0); Frequency: 2412 MHz;Duty Cycle: 1:1 Medium: HSL_2450 Medium parameters used: f = 2412 MHz; Ο = 1.756 S/m; Ξ΅ r = 38.722; Ο = 1000 kg/m 3 Ambient TemperatureοΌ23.2 Β°C; Liquid TemperatureοΌ22.1 Β°C DASY5 Configuration: - Probe: EX3DV4 - SN3809; ConvF(7.42, 7.42, 7.42) @ 2412 MHz; Calibrated: 2022.12.10 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE3 Sn373; Calibrated: 2022.12.28 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Ch1/Area Scan (81x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 2.12 W/kg Ch1/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 1.653 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 3.31 W/kg SAR(1 g) = 1.23 W/kg; SAR(10 g) = 0.428 W/kg Maximum value of SAR (measured) = 2.14 W/kg 0 dB = 2.14 W/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23060377S01 Date: 2023.8.19 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Bluetooth_BLE_Front Side_0mm_Ch0 Communication System: UID 0, Bluetooth (0); Frequency: 2402 MHz;Duty Cycle: 1:0.992 Medium: HSL_2450 Medium parameters used: f = 2402 MHz; Ο = 1.742 S/m; Ξ΅ r = 38.782; Ο = 1000 kg/m 3 Ambient TemperatureοΌ23.2 Β°C; Liquid TemperatureοΌ22.1 Β°C DASY5 Configuration: - Probe: EX3DV4 - SN3809; ConvF(7.42, 7.42, 7.42) @ 2402 MHz; Calibrated: 2022.12.10 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE3 Sn373; Calibrated: 2022.12.28 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Ch0/Area Scan (81x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 0.217 W/kg Ch0/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 0.311 W/kg SAR(1 g) = 0.122 W/kg; SAR(10 g) = 0.043 W/kg Maximum value of SAR (measured) = 0.210 W/kg 0 dB = 0.210 W/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23060377S01
MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23060377S01 Annex E Conducted Power Note: Conducted power unit: dBm The target power was recorded in the manufacture document. 2.4GHz WLAN ANT 1 CH 1241213.8614.5020.00 CH 7244210.9011.5020.00 CH 1324726.377.0030.00 CH 1241213.0013.5042.0099.53 CH 7244213.3514.0040.0099.64 CH 13247211.0211.5040.0099.64 CH 1241212.5613.0042.0099.61 CH 7244212.7513.5038.0099.41 CH 13247210.1211.0040.0099.61 GMSKTune-up Limit Duty Cycle % CH 0024024.545.0084.00 CH 1924402.783.5083.60 CH 3924802.843.5083.60 888 Duty Cycle % 100.00 LE Power Setting Frequency (MHz) Channel Average power (dBm) Mode 2.4GHz WLAN ANT 1 ModePower Setting 802.11b 1Mbps 802.11g 6Mbps 802.11n-HT20 MCS0 Channel Average power (dBm) Tune-Up Limit Frequency (MHz) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23060377S01
MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23060377S01 Annex F DASY Calibration Certificate
Annual validation for test lab. Appendix Annual validation for Test Lab. General calibration information Date 2022.12.15 Test Laboratory ShenZhen Morlab Communications Technology Co., Ltd. Antenna serial No. D2450V2-SN: 805 Antenna Parameters with Head TSL Impedance, transformed to feed point 50.661Ξ©-5.59jΞ© Return Loss -23.203dB General Antenna Parameters and Design Electrical Delay (one direction) 1.276 ns After long term use with 100W radiated powerοΌonly a slight warming of the dipole near the feed point can be measured The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC-signals. On some of the dipoles, small end caps are added to the dipole arms in order to improve matching when loaded according to the position as explained in the "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still according to the Standard No excessive force must be applied to the dipole armοΌ because they might bend or the soldered connections near the feed point may be damaged . Annual validation for test lab. Annual validation for test lab. Appendix Impedance Measurement Plot for Head TSL
NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23060377S01 Page 1 of 39 TEST REPORT APPLICANT : Shenzhen Digitizing Fluid Technology Co., Ltd. PRODUCT NAME : DiFluid Omni MODEL NAME : DFT-SD101 BRAND NAME : DiFluid FCC ID : 2A26IDFT-SD101 STANDARD(S) : FCC 47 CFR Part 2(2.1093) IEEE 1528-2013 RECEIPT DATE : 2023-07-06 TEST DATE : 2023-08-19 ISSUE DATE : 2023-09-18 Edited by : Xie Yiyun (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23060377S01 Page 2 of 39 DIRECTORY 1. SAR Results Summary ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 5 2. Technical Information ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 6 2.1. Applicant and Manufacturer Information βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 6 2.2. Equipment under Test (EUT) Description ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 6 2.3. Environment of Test Site/Conditions βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 7 3. Specific Absorption Rate (SAR) βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 8 3.1. Introductionββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 8 3.2. SAR Definition βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 8 4. RF Exposure Limits βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 9 4.1. Uncontrolled Environment βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 9 4.2. Controlled Environment βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 9 5. Applied Reference Documents ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 10 6. SAR Measurement System βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 11 6.1. E-Field Probe βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 12 6.2. Data Acquisition Electronics (DAE) ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 13 6.3. Robot ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 13 6.4. Measurement Server βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 14 6.5. Light Beam Unit βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 14 6.6. Phantom βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 14 6.7. Device Holder ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 15 6.8. Data Storage and Evaluation βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 16 6.9. Test Equipment List ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 18 7. Tissue Simulating Liquids ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 19 8. SAR System Verification βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 21 8.1. Purpose of System Performance check ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 21 8.2. System Setup βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 21 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23060377S01 Page 3 of 39 8.3. Validation Results βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 22 9. EUT Testing Position βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 25 9.1. Body-worn Configurations ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 25 9.2. Hotspot Mode Exposure Position Conditions ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 25 10. Measurement Procedures βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 27 10.1. Spatial Peak SAR Evaluation βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 27 10.2. Power Reference Measurement ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 28 10.3. Area Scan Procedures ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ¦
Text truncated - open the document above for the full version.
Shenzhen Shuodian Electronic Technology Co.,Ltd Shenzhen Shuodian Electronic Technology Co.,Ltd Page number 1-12 SPECIFICATION for SD101-C/FPC 倩线 2.4G倩线 Customer No. Product No. SD101-C/FPC 倩线 2.4G倩线 AuthorοΌζΎε°ε€ ReviewοΌζζ Release DateοΌ 2023.06.21 ShenZhen Shuodian Electronic Technology Co., Ltd 508 West, building 64, Jinlong Industrial City, majialong, Nanshan District, Shenzhen E-mailοΌ[email protected] Tel: 0755-86006322 Fax: 0755-86006323 Shenzhen Shuodian Electronic Technology Co.,Ltd Date:2014-6-30 Page number 2-8 Shenzhen Shuodian Electronic Technology Co.,Ltd Shenzhen Shuodian Electronic Technology Co.,Ltd Page number 2-12 Contents SPECIFICATION .................................................................................................................... 1 SHENZHEN SHUODIAN ELECTRONIC TECHNOLOGY CO., LTD ........................................ 1 CONTENTS ............................................................................................................................. 2 2.GENERAL ........................................................................................................................ 3 3.GENERAL PRODUCT SPECIFICATIONS ................................................................. 3 4.SPECIFICATION DETIALS ............................................................................................. 4 4.1 MECHANICAL PROPERTIES ............................................................................................... 4 4.2 ELECTRIC PERFORMANCE ............................................................................................. 6 5.PRODUCT PACKAGING ............................................................................................. 9 6.DOCUMENT RESUME ................................................................................................ 9 Shenzhen Shuodian Electronic Technology Co.,Ltd Date:2014-6-30 Page number 4-8 Shenzhen Shuodian Electronic Technology Co.,Ltd Shenzhen Shuodian Electronic Technology Co.,Ltd Page number 4-12 2.General 2.1 Scope of application SD101-C/FPC 倩线 2.4G倩线 2.2 Operating temperature range Temperature range of this product: -20 ~ +65 Β°C 2.3 Storage temperature range: This product is stored at - 30 ~ + 75 Β°C 3.General product specifications NO. ITEMS DETAILS 1 Type SD101-C/FPC 倩线 2.4G倩线 2 Operating Frequency Band 2400-2500MHz 3 VSWR οΌ2.0 5 Radiation Efficiency β₯50% 6 Impedance 50Ξ© 7 Antenna Type Dipole Array 8 Antenna composition FPC Shenzhen Shuodian Electronic Technology Co.,Ltd Date:2014-6-30 Page number 5-8 Shenzhen Shuodian Electronic Technology Co.,Ltd Shenzhen Shuodian Electronic Technology Co.,Ltd Page number 5-12 4.Specification Detials 4.1 Mechanical Properties 4.11 Product CompositionοΌ No. Material Size (MM) 1 FPC 27.48*26.23 2 Coxial Line Γ1.13 55MM Black 4.12 Apperance Good appearance without scars γdirtsγprotuberances, etc. 4.13 Antenna Picture and Structure Dimension Refer to product drawings: Shenzhen Shuodian Electronic Technology Co.,Ltd Date:2014-6-30 Page number 6-8 Shenzhen Shuodian Electronic Technology Co.,Ltd Shenzhen Shuodian Electronic Technology Co.,Ltd Page number 6-12 Product drawingsοΌ Shenzhen Shuodian Electronic Technology Co.,Ltd Date:2014-6-30 Page number 7-8 Shenzhen Shuodian Electronic Technology Co.,Ltd Shenzhen Shuodian Electronic Technology Co.,Ltd Page number 7-12 4.2 Electric Performance 4.21 Test condition EnvironmentοΌ TemperatureοΌ 10Β°Cββ+30Β°C HumidityοΌ β€80%οΌ+40Β°CοΌ AtmospherοΌ 750mmkgΒ±30mmkg EquipmentοΌ Network Analyzer: Agilent E8358A Anechior Chamber: ETS 4.22 Test Data for Electrical Performance: 4.22.1 S11 of the Antenna: Marker 2400MHz 2450MHz 2500MHz Returnloss -15.5 -18.9 -18.7 VSWR 1.4 1.2 1.2 Shenzhen Shuodian Electronic Technology Co.,Ltd Date:2014-6-30 Page number 8-8 Shenzhen Shuodian Electronic Technology Co.,Ltd Shenzhen Shuodian Electronic Technology Co.,Ltd Page number 8-12 4.22.2倩线ηε’ηζηεθΎε°ζΉεεΎοΌ ι’ηοΌMhzοΌ 2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500 Gain(dBi) 1.02 1.12 1.15 1.21 1.17 1.26 1.49 1.64 1.62 1.56 1.47 Efficenc(%) 39.62 40.10 40.11 40.31 40.32 40.42 40.70 41.62 41.18 40.85 40.63 Shenzhen Shuodian Electronic Technology Co.,Ltd Date:2014-6-30 Page number 9-8 Shenzhen Shuodian Electronic Technology Co.,Ltd Shenzhen Shuodian Electronic Technology Co.,Ltd Page number 9-12 Radiation pattern: frequency 2450MHz Shenzhen Shuodian Electronic Technology Co.,Ltd Date:2014-6-30 Page number 10-8 Shenzhen Shuodian Electronic Technology Co.,Ltd Shenzhen Shuodian Electronic Technology Co.,Ltd Page number 10-12 5.Product Packaging Manner of packing: Packed in self sealed bags, 200 pcs each. 6.Document Resume Document No. Release Date 2023/6/21 Author Hungjie Review WH Revised History Date Version Revised Record 2023/6/21 1.00 New Project
NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 56 REPORT No.οΌSZ23060377W01 TEST REPORT APPLICANT : Shenzhen Digitizing Fluid Technology Co., Ltd. PRODUCT NAME : DiFluid Omni MODEL NAME : DFT-SD101 BRAND NAME : DiFluid FCC ID : 2A26IDFT-SD101 STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2023-07-06 TEST DATE : 2023-07-17 to 2023-08-25 ISSUE DATE : 2023-09-19 Edited by: Su Xiaoxian (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 56 REPORT No.οΌSZ23060377W01 DIRECTORY 1. Summary of Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 4 1.1. Testing Applied Standards κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.2. Test Equipment List κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 6 1.3. Measurement Uncertainty κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 1.4. Testing Laboratory κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 2. General Description κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.1. Information of Applicant and Manufacturer κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.2. Information of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.3. Channel List of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 2.4. Test Configuration of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 2.5. Test Conditions κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 2.6. Test Setup Layout Diagram κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 3. Test Results κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 14 3.1. Antenna Requirement κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 14 3.2. Duty Cycle of Test Signal κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 3.3. Maximum Peak Conducted Output Power κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 3.4. Maximum Average Conducted Output Power κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 17 3.5. 6 dB Bandwidth κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 18 3.6. Conducted Spurious Emissions and Band Edge κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 19 3.7. Power Spectral Density κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 20 3.8. Conducted Emission κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 21 3.9. Restricted Frequency Bands κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 22 3.10. Radiated Emission κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 23 Annex A Test Data and Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 25 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 56 REPORT No.οΌSZ23060377W01 Change History Version Date Reason for change 1.0 2023-09-19 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 56 REPORT No.οΌSZ23060377W01 1. Summary of Test Result No. Section Description Test Date Test EngineerResult Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A PASS No deviation 2 N/A Duty Cycle of Test Signal Jul. 19, 2023 Zhong Yanshan PASS No deviation 3 15.247(b) Maximum Peak Conducted Output Power Jul. 19, 2023 Zhong Yanshan PASS No deviation 4 15.247(b) Maximum Average Conducted Output Power Jul. 19, 2023 Zhong Yanshan PASS No deviation 5 15.247(a) Bandwidth Jul. 19, 2023 Zhong Yanshan PASS No deviation 6 15.247(d) Conducted Spurious Emission and Band Edge Jul. 19, 2023 Zhong Yanshan PASS No deviation 7 15.247(e) Power Spectral Density Jul. 19, 2023 Zhong Yanshan PASS No deviation 8 15.207 Conducted Emission Jul. 24, 2023 Fan Zehang PASS No deviation 9 15.247(d) Restricted Frequency Bands Aug. 25, 2023 Yang Lian PASS No deviation 10 15.209, 15.247(d) Radiated Emission Aug. 04, 2023 Gao Jianrou PASS No deviation Note 1: Measurements to demonstrate compliance with the conducted limits are not required for devices which only employ battery power for operation and which do not operate from the AC power lines or contain provisions for operation while connected to the AC power lines. Note 2: The tests were performed according to the method of measurements prescribed in ANSIC63.10-2013 and KDB558074 D01 v05rβ¦
Text truncated - open the document above for the full version.
NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 93 REPORT No.οΌSZ23060377W02 TEST REPORT APPLICANT : Shenzhen Digitizing Fluid Technology Co., Ltd. PRODUCT NAME : DiFluid Omni MODEL NAME : DFT-SD101 BRAND NAME : DiFluid FCC ID : 2A26IDFT-SD101 STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2023-07-06 TEST DATE : 2023-07-17 to 2023-08-25 ISSUE DATE : 2023-09-19 Edited by: Su Xiaoxian (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 93 REPORT No.οΌSZ23060377W02 DIRECTORY 1. Summary of Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 4 1.1. Testing Applied Standards κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.2. Test Equipment List κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 6 1.3. Measurement Uncertainty κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 1.4. Testing Laboratory κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 2. General Description κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.1. Information of Applicant and Manufacturer κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.2. Information of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.3. Channel List of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 2.4. Test Configuration of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 2.5. Test Conditions κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 2.6. Test Setup Layout Diagram κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 12 3. Test Results κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 3.1. Antenna Requirement κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 3.2. Duty Cycle of Test Signal κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 3.3. Maximum Peak and Average Conducted Output Power κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 17 3.4. 6 dB Bandwidth κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 18 3.5. Conducted Spurious Emissions and Band Edge κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 19 3.6. Power Spectral Density κκκκκκκκκκκκκκκκκκκκκκβ¦
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.47 GHz | 523.60 mW |
DiFluid Omix
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
DiFluid R2 Extract with BLE
Equipment Class
DTS - Digital Transmission System