Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment
Guanyu(Dongguan)IntelligentTechnologyCo.,Ltd AgentAuthorization Company:Guanyu(Dongguan)IntelligentTechnologyCo.,Ltd Address:1001Room,No#3building,No#36Fuxingroad,Chang’an town,DongguanCity,GuangdongChina ProductName:WirelessCharger ModelNumber(s):GY-Z15,GY-Z15A,GY-Z15B,GY-Z15C,GY-Z15D ProductDescription:WirelessCharger WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:03/29/2022 Name: ManFangWu Title: Manager Company: Guanyu(Dongguan)IntelligentTechnologyCo.,Ltd
Guanyu(Dongguan)IntelligentTechnologyCo.,Ltd Office of EngineeringTechnology FederalCommunicationsCommission 7435 OaklandMills Road Columbia,MD 21046 USA Date: 03/29/2022 Subject;Requestfor Confidentiality FCC ID: 2A2NS-GY- Z15 To WhomIt May Concern, Pursuantto the provisionsof the Commission’s rules Title 47 Sections§0.457 and §0.459,we are requestingthe Commissionto withholdthe followingattachment(s)as confidential documentsfrom public disclosureindefinitely. Thesedocumentscontaindetailedsystemand equipmentdescriptionsand are consideredas proprietaryinformationin operationof the equipment.The public disclosureof these documents might be harmfulto our companyand would give competitorsan unfair advantagein the market. Schematic Diagram Block Diagram Operational Description Parts List Tune-up Procedure In additionalto abovementioneddocuments,in order to complywith the marketingregulations in Title 47 CFR §2.803 and the importationrules in Title 47 CFR §2.1204,while ensuringthat businesssensitiveinformationremainsconfidentialuntil the actualmarketingof newly authorizeddevices,we requestShort Term Confidentialityof the followingattachment(s); ExternalPhotos Test Setup Photos InternalPhotos User Manual For 45 days, pursuantto PublicNoticeDA 04-1705. OR For 180 days pursuantto KDB 726920D01. It is our understandingthat all measurementtest reports,FCC ID label formatand correspondenceduringthe certificationreviewprocesscannotbe grantedas confidential documentsand this informationwill be availablefor public reviewonce the grant of equipment authorizationis issued. Sincerely, Signature: Name:ManFangWu Title:Manager
Modeldifferencedeclarationletter DifferencesDescription WeGuanyu(Dongguan)IntelligentTechnologyCo.,Ltdstate: Product: WirelessCharger ModelName: GY-Z15,GY-Z15A,GY-Z15B,GY-Z15C,GY-Z15D Theaboveproductwithsamecircuit,PCBlayout,electricalparts,materialsand wiringstructures,Appearanceshape,thematerialsofdecorativeaccessoriesis same,onlydifferentcolor. Signatory Date:03-29-2022 <Signature> Name:ManFangWu Title:manager Company:Guanyu(Dongguan)IntelligentTechnologyCo.,Ltd Address:1001Room,No#3building,No#36Fuxingroad,Chang’antown,DongguanCity,Guangdong China
Page1of3ReportNo.:FCS202203104 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202203104 Photo3 Photo4 Page3of3ReportNo.:FCS202203104 Photo5 Photo6
LabelandLabelLocation FCCID:2A2NS-GY-Z15 L*W:20mm*17mm whitefontonaBlacklabel
Page1of3ReportNo.:FCS202203104 Internalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202203104 Photo3 Photo4 Page3of3ReportNo.:FCS202203104 Photo5 Photo6 ANT
Page1of5ReportNo.:FCS202203104W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RFExposureEvaluation 2A2NS-GY-Z15 1MeasuringStandard KDB680106D01RFExposureWirelessChargingAppsv03r01 2Requirements AccordingtoKDB680106clause5,b Inductivewirelesspowertransferapplicationsthatmeetallofthefollowingrequirementsareexcluded (1)Powertransferfrequencyislessthan1MHz. --Yes,thedeviceoperatedinthefrequencyrangefrom115KHzto205KHz (2)Outputpowerfromeachprimarycoilislessthanorequalto15watts. --Yes,themaximumoutputpoweroftheprimarycoilis15W (3)Thesystemmayconsistofmorethanonesourceprimarycoils,chargingoneormoreclients.If morethanoneprimarycoliispresent,thecoilpairymaybepoweredonatthesametime. --Yes,theproducthasapluralityofcoil,andsupportthesamecoilhair. (4)Clientdeviceisplaceddirectlyincontactwiththetransmitter. --Yes,Clientdeviceisplaceddirectlyincontactwiththetransmitter (5)Mobileexposureconditionsonly(portableexposureconditionsarenotcoveredbythisexclusion). --Yes (6)TheaggregateH-fieldstrengthsat15cmsurroundingthedeviceand20cmabovethetopsurface fromallsimultaneoustransmittingcoilsaredemonstratedtobelessthan50%oftheMPElimit. --Yes,theEUTfieldstrengthlevelare50%xMPElimit. 3Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhuman exposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Page2of5ReportNo.:FCS202203104W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 4TestSetup 5TestProcedure 1)TheRFexposuretestwasperformedinanechoicchamber. 2)Themeasurementprobewasplacedattestdistance(15cmfromallsidesand20cmfrom thetop)whichisbetweentheedgeofthechargerandthegeometriccenterofprobe. 3)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurement ofeachpoints(A,B,C,D,E)werecompleted 4)TheEUTwasmeasuredaccordingtothedictatesofKDB680106D01v03r01 Remark : TheEUT’stestpositionA,B,C,DandEisvalidfortheEandHfieldmeasurements Page3of5ReportNo.:FCS202203104W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 6Equipmentlist TestEquipmentManufacturerModelNo.SN.Last calibration Calibrated until Electricand Magnetic field probe-Analyzer NardaEHP-200AN03565Feb10,2022Feb09,2023 7Photo Page4of5ReportNo.:FCS202203104W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 8Testmode Mode1Earbuds(3W) Mode2Phone(5W) Mode3Phone(7.5W) Mode4Phone(10W) Mode5Phone(15W) Mode6Earbuds(3W)+Phone(5W) Mode7Earbuds(3W)+Phone(7.5W) Mode8Earbuds(3W)+Phone(10W) Mode9Earbuds(3W)+Phone(15W) 9Necessaryaccessories ItemEquipmentMfr/BrandModel/TypeNo.SerialNo.Note 1PhoneHWMate20N/A Thisphoneisfor testingonlyin report. 2EarbudsHWFreeBudsProN/A ThisEarbudsis fortestingonlyin report. 10TestResult E-FiledStrengthat15cmfromtheedgessurroundingtheEUT(V/m) Battery power Frequency Range(MHz) Test Position A Test Position B Test Position C Test Position D Limits (V/m) 1%0.115-0.2051.411.520.570.51614 50%0.115-0.2051.641.210.440.61614 95%0.115-0.2051.221.570.410.57614 Stand-by0.115-0.2051.351.240.560.51614 Page5of5ReportNo.:FCS202203104W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com E-FiledStrengthat20cmfromthetopoftheEUT(V/m) Battery power Frequency Range(MHz) Test PositionE Limits (V/m) 1%0.115-0.2051.22614 50%0.115-0.2051.31614 95%0.115-0.2051.41614 Stand-by0.115-0.2051.57614 H-FiledStrengthat15cmfromtheedgessurroundingtheEUT(A/m) Battery power Frequency Range(MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 1%0.115-0.2050.630.610.710.621.63 50%0.115-0.2050.630.630.670.551.63 95%0.115-0.2050.610.620.540.531.63 Stand-by0.115-0.2050.570.610.650.511.63 H-FiledStrengthat20cmfromthetopoftheEUT(A/m) Battery power Frequency Range(MHz) Test PositionE Limits (A/m) 1%0.115-0.2050.431.63 50%0.115-0.2050.341.63 95%0.115-0.2050.451.63 Stand-by0.115-0.2050.511.63 Testedby:Reviewedby: ※※※※※ENDOFTHEREPORT※※※※※
FCCTestReport ReportNo:FCS202203104W01 Issuedfor Applicant:Guanyu(Dongguan)IntelligentTechnologyCo.,Ltd Address: 1001Room,No#3building,No#36Fuxingroad, Chang’antown,DongguanCity,GuangdongChina ProductName:WirelessCharger BrandName:Guany ModelName:GY-Z15 SeriesModel: GY-Z15A、GY-Z15B、GY-Z15C、GY-Z15D FCCID:2A2NS-GY-Z15 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page2of24ReportNo.:FCS202203104W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:Guanyu(Dongguan)IntelligentTechnologyCo.,Ltd Address......................................: 1001Room,No#3building,No#36Fuxingroad,Chang’an town,DongguanCity,GuangdongChina Manufacture'sName ................ :Guanyu(Dongguan)IntelligentTechnologyCo.,Ltd Address......................................: 1001Room,No#3building,No#36Fuxingroad,Chang’an town,DongguanCity,GuangdongChina ProductDescription ProductName ........................... :WirelessCharger BrandName ............................. :Guany ModelName..............................:GY-Z15 SeriesModel..............................: GY-Z15A 、 GY-Z15B 、 GY-Z15C 、 GY-Z15D TestStandards..........................:FCCRulesandRegulationsPart15SubpartC,Section209 TestProcedure..........................:ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedFCS,thetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFCS,thisdocument maybealteredorrevisedbyFCS,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests . :15Mar.2022~25Mar.2022 DateofIssue ................................. :25Mar.2022 TestResult.....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (JackWang) Page3of24ReportNo.:FCS202203104W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................5 1.1TESTFACTORY................................................................................................................6 1.2MEASUREMENTUNCERTAINTY.....................................................................................6 2.GENERALINFORMATION.......................................................................................................7 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................7 2.2DESCRIPTIONOFTHETESTMODES............................................................................8 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS..................9 2.4EQUIPMENTSLIST.........................................................................................................10 3CONDUCTEDEMISSIONMEASUREMENT..........................................................................11 3.1LIMIT.................................................................................................................................11 3.2TESTPROCEDURE........................................................................................................11 3.3TESTSETUP...................................................................................................................12 3.4TESTRESULTS...............................................................................................................13 4.RADIATEDEMISSIONMEASUREMENT..............................................................................15 4.1LIMIT................................................................................................................................15 4.2TESTPROCEDURE........................................................................................................16 4.3TESTSETUP...................................................................................................................17 4.4TESTRESULTS...............................................................................................................18 5.20DBBANDWIDTHTEST.....................................................................................................22 5.1LIMIT................................................................................................................................22 5.2TESTPROCEDURE........................................................................................................22 5.3TESTSETUP...................................................................................................................22 5.4TESTRESULTS...............................................................................................................23 6.ANTENNAREQUIREMENT...................................................................................................24 6.1STANDARDREQUIREMENT..........................................................................................24 6.2EUTANTENNA................................................................................................................24 Page4of24ReportNo.:FCS202203104W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RevisionHistory Rev.IssueDateEffectPageContents 0025Mar.2022AllInitialIssue Page5of24ReportNo.:FCS202203104W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO…
Text truncated - open the document above for the full version.
Page1of2ReportNo.:FCS202203104 Blow1GHzforradiatedemissiontestsetup Page2of2ReportNo.:FCS202203104 Conductedemissiontestsetup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.115 MHz - 0.205 MHz | - |

3 IN 1 Speaker With Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
3 IN 1 Fast Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
4IN1 Multifunction Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
2 IN1 Magnetic Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
3-in-1 Fast Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz