Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Rev 1/26/2023 CLEANLIFE ENERGY LLC Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 01-23-2026 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2A2YF-CL-1G5 CLEANLIFE ENERGY LLC (“the applicant”) certifies that, as of the date of the filing of the application, we designate ourselves as the U.S. agent for service of process. Designated U.S. Agent Information: FRN: 0031297955 Name: CLEANLIFE ENERGY LLC Address: 7620 Hub Parkway Valley View Ohio, 44125 USA Contact Person: Danny DiCioccio Tel.: 1-800-316-2532 Email: [email protected] Sincerely, CLEANLIFE ENERGY LLC Danny DiCioccio [Applicant signature] 01/26/2026
CLEANLIFE ENERGY LLC 01-23-2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2A2YF-CL-1G5 CLEANLIFE ENERGY LLC (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) Danny DiCioccio 01/26/2026 CLEANLIFE ENERGY LLC 01-23-2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2A2YF-CL-1G5 CLEANLIFE ENERGY LLC (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) Danny DiCioccio 01/26/2026
CLEANLIFE ENERGY LLC Date: Jan. 23, 2026 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2A2YF-CL-1G5 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Long-term confidentiality: Schematics Block Diagram Operational Description Schematics.pdf Block Diagram.pdf Operational Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, CLEANLIFE ENERGY LLC Signature Danny DiCioccio / Product Development Manager Typed name and Title 01/26/2026
CLEANLIFE ENERGY LLC FCC ID: 2A2YF-CL-1G5 POWER OF ATTORNEY Date: Jan. 23, 2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Testing Group Co., Ltd. (Deval Qin) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Testing Group Co., Ltd. (Deval Qin) on our behalf shall have the same effect as acts of our own. This authorization expires on Dec. 31, 2026. Sincerely, CLEANLIFE ENERGY LLC Signature Danny DiCioccio / Product Development Manager Typed name and Title 01/26/2026
CLEANLIFE ENERGY LLC FCC ID: 2A2YF-CL-1G5 Date: 1/26/26 Subject: authorization for adding family models To whom it May concern, Statement We confirm the product Wireless Kinetic Switch with models CL-1G5 and CL-1G2 are same in the Schematic, PCB layout, Operation description, BOM and Antenna. Only the model names and button quantity are different. Yours sincerely, [signature] Danny DiCioccio Product Development Manager CLEANLIFE ENERGY LLC 01/26/2026
Appendix-CL-1G5-Photos Page 3 of 8 2. Photographs –Constructional Details 2.1. EUT – External View Model CL-1G5 FCC ID: 2A2YF-CL-1G5 Appendix-CL-1G5-Photos Page 4 of 8 Appendix-CL-1G5-Photos Page 5 of 8
5 6 7 8 F 9 78 A 9 D C B E F 1 2 E D C B A 1 2 3 4 3456 广东易百珑智能科技有限公司 A 2024XXXX 技术要求: U5 Plastic 陈萍 正面 背面侧面 2026/02/05 1.镭雕字印清晰,不断线、拖笔画不得有重线,杂点等缺陷。 2.字体:标题ManropeLight,字体大小5.5号 内容ManropeExtraLight,字体大小5号, 行间距105%,字符间距0%,注意间距。 正面ManropeLight,字体大小8号 3.认证标志尺寸:英文CE/ROHS标志高度5mm,垃圾桶标志高度7mm。 4.镭雕:紫外镭雕 5.尺寸公差±0.3mm Wireless Kinetic Switch Model: CL-1G5 Part #: CL- FCC ID: 2A2YF-CL-1G5 Frequency: RF 433MHz Power Supply: Self-powered
Appendix-CL-1G5-Photos Page 6 of 8 2.2. EUT – Internal View Model CL-1G5 FCC ID: 2A2YF-CL-1G5 ANT Appendix-CL-1G5-Photos Page 7 of 8 Appendix-CL-1G5-Photos Page 8 of 8 ======End======
Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 9 TEST REPORT Referen ce No. .................... : WTD26D01018415W002 FCC ID ................................ : 2A2YF-CL-1G5 Applicant ............................ : CLEANLIFE ENERGY LLC Address .............................. : 7620 Hub Parkway Valley View Ohio, 44125 USA Manufacturer .................... : Guang Dong Ebelong Intelligent Technology Co., Ltd Address .............................. : 3th&4th Floor, Block 2, Hengmingzhu Technology lndustrial Park, Xingqiao Tongfuyu Industrial District, Gonghe community, Shajing Product ............................... : Wireless Kinetic Switch Model(s). ............................ : CL-1G5, CL-1G2 Standards........................... : FCC 47CFR Part 2 Subpart J Section 2.1091 Date of Receipt Sample .... : 2026-01-22 Date of Test ....................... : 2026-01-23 to 2026-02-03 Date of Issue ...................... : 2026-02-06 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: Estel Qian / Project Engineer Deval Qin / Designated Reviewer Reference No.: WTD26D01018415W002 Page 2 of 9 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2. Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2. CONTENTS ............................................................................................................................................... 2 3. REVISION HISTORY ................................................................................................................................. 3 4. GENERAL INFORMATION ....................................................................................................................... 4 4.1. GENERAL DESCRIPTION OF E.U.T.................................................................................................... 4 4.2. DETAILS OF E.U.T. ......................................................................................................................... 4 4.3. TEST FACILITY ................................................................................................................................ 4 4.4. SUBCONTRACTED ........................................................................................................................... 5 4.5. ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................ 5 5. TEST SUMMARY ...................................................................................................................................... 6 6. RF EXPOSURE ......................................................................................................................................... 7 6.1. REQUIREMENTS .............................................................................................................................. 7 6.2. THE PROCEDURES / LIMIT ................................................................................................................ 7 6.3. MPE CALCULATION METHOD........................................................................................................... 8 6.4. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ................................................................... 8 Reference No.: WTD26D01018415W002 Page 3 of 9 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 3. Revision History Test Report No. Date of Receipt Sample Date of Test Date of Issue Purpose CommentApproved WTD26D01018415W002 2026-01-22 2026-01-23 to 2026-02-03 2026-02-06Original - Valid Reference No.: WTD26D01018415W002 Page 4 of 9 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 4. General Information 4.1. General Description of E.U.T. Product Name: Wireless Kinetic Switch Model No.: CL-1G5, CL-1G2 Model Description: Only the model names and button quantity are different. The model CL-1G5 was tested in this report. Test Sample No.: 1-1/1 Hardware Version: 1.0 Software Version: 1.0 4.2. Details of E.U.T. Frequency Range: 433.301MHz Type of Modulation: FSK The Lowest Oscillator: XTAL: 26MHz Antenna installation: Internal Antenna Antenna Gain -1.70dBi Note: #: The antenna gain is provided by the applicant, and the applicant should be responsible for its authenticity, WALTEK lab has not verified the authenticity of its information. Ratings: Self-powered 4.3. Test Facility The test facility has a test site registered with the following organizations: ISED CAB identifier: CN0013. Test Firm Registration No.: 7760A. Waltek Testing Group Co., Ltd. Has been registered and fully described in a report filed with the Industry Canada. The acceptance letter from the Industry Canada is maintained in our files. Registration number 7760A, October 15, 2016. FCC Designation No.: CN1201. Test Firm Registration No.: 523476. Waltek Testing Group Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration number 523476, September 10, 2019. Reference No.: WTD26D01018415W002 Page 5 of 9 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 4.4. Subcontracted Whether parts of tests for the product have been subcontracted to other labs: Yes No If Yes, list the related test items and lab information: Test Lab: N/A Lab address: N/A Test items: N/A 4.5. Abnormalities fr…
Text truncated - open the document above for the full version.
ANTENNA SPECIFICATION Summary ITEM ANT SPEC Model Name ANT_U5 Polarization Horizontal and Vertical Azimuth Beam Pattern Omni‐directional Impedance 50 Ohm Antenna Length 173mm Manufacture Dongguan Kengjin Hardware Products Co., Ltd. Manufacturer's address No. 99-1, Yanggonglang Road, Qiaotou Town, Dongguan City, Guangdong Province Gain value : channel/MHz 433 434 435 gain/dbi‐1.70‐1.85‐1.90 efficiency/% 39.5 40.0 39.7 Antenna size :Length 173mm, diameter 0.8mm \ Antenna pattern
Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 18 TEST REPORT Reference No..................... : WTD26D01018415W001 FCC ID ................................ : 2A2YF-CL-1G5 Applicant ........................... : CLEANLIFE ENERGY LLC Address ............................. : 7620 Hub Parkway Valley View Ohio, 44125 USA Manufacturer .................... : Guang Dong Ebelong Intelligent Technology Co., Ltd Address ............................. : 3th&4th Floor, Block 2, Hengmingzhu Technology lndustrial Park, Xingqiao Tongfuyu Industrial District, Gonghe community, Shajing Street, Baoan, Shenzhen, China. Product .............................. : Wireless Kinetic Switch Model(s). ............................ : CL-1G5, CL-1G2 Standards .......................... : FCC 47CFR Part 15 Subpart C Section 15.231 Date of Receipt Sample .... : 2026-01-22 Date of Test ....................... : 2026-01-23 to 2026-02-03 Date of Issue ..................... : 2026-02-06 Test Result ........................ : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: Estel Qian / Project Engineer Deval Qin /Designated Reviewer Reference No.: WTD26D01018415W001 Page 2 of 18 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 CONTENTS ............................................................................................................................................... 2 3 REVISION HISTORY ................................................................................................................................. 3 4 GENERAL INFORMATION ....................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF E.U.T.................................................................................................... 4 4.2 DETAILS OF E.U.T. ......................................................................................................................... 4 4.3 TEST MODE .................................................................................................................................... 4 5 EQUIPMENT USED DURING TEST ......................................................................................................... 5 5.1 EQUIPMENTS LIST ........................................................................................................................... 5 5.2 MEASUREMENT UNCERTAINTY ......................................................................................................... 6 5.3 TEST EQUIPMENT CALIBRATION ....................................................................................................... 6 5.4 TEST FACILITY ................................................................................................................................ 6 5.5 SUBCONTRACTED ........................................................................................................................... 6 6 TEST SUMMARY ...................................................................................................................................... 7 7 RADIATED SPURIOUS EMISSIONS ....................................................................................................... 8 7.1 EUT OPERATION ............................................................................................................................ 8 7.2 TEST SETUP ................................................................................................................................... 9 7.3 SPECTRUM ANALYZER SETUP ........................................................................................................ 10 7.4 TEST PROCEDURE ........................................................................................................................ 11 7.5 SUMMARY OF TEST RESULTS ........................................................................................................ 11 8 PERIODIC OPERATION ......................................................................................................................... 13 9 EMISSION BANDWIDTH ........................................................................................................................ 16 9.1 TEST PROCEDURE ........................................................................................................................ 16 9.2 TEST RESULT ............................................................................................................................... 16 10 ANTENNA REQUIREMENT ................................................................................................................... 18 11 RF EXPOSURE ....................................................................................................................................... 18 12 PHOTOGRAPHS –TEST SETUP AND EUT .......................................................................................... 18 Reference No.: WTD26D01018415W001 Page 3 of 18 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 3 Revision History Test Report No. Date of Receipt Sample Date of Test Date of Issue Purpose CommentApproved WTD26D01018415W001 2026-01-22 2026-01-23 to 2026-02-03 2026-02-06Original - Valid Reference No.: WTD26D01018415W001 Page 4 of 18 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn…
Text truncated - open the document above for the full version.
Appendix-CL-1G5-Photos Page 1 of 8 1. Test Setup photos Model CL-1G5 FCC ID: 2A2YF-CL-1G5 1.1 Photograph – Radiated Emissions For 9kHz-30MHz Test Site 2# For 30MHz-1000MHz Test Site 2# Appendix-CL-1G5-Photos Page 2 of 8 For Above 1GHz Test Site 1#
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.301 MHz - 433.301 MHz | - |

Electronic Lock
Equipment Class
DTS - Digital Transmission System
Wireless Kinetic Switch
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
USB SMART BEACON TAPE LIGHT
Equipment Class
DTS - Digital Transmission System