
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CQ60-3-SET-V2_SG_OTP_033023_tk.indd 1-3CQ60-3-SET-V2_SG_OTP_033023_tk.indd 1-330/03/2023 18:4530/03/2023 18:45 CQ60-3-SET-V2_SG_OTP_033023_tk.indd 4-6CQ60-3-SET-V2_SG_OTP_033023_tk.indd 4-630/03/2023 18:4530/03/2023 18:45
RJBrandsLLC 021423-17rev4 CertificationApplicationAttestationStatements Date:July17,2023 AmericanCertificationBody,Inc. 313ParkAvenue Suite300 FallsChurch,VA22046 ToWhomItMayConcern: Statementfor47CFRsection2.911(d)(5)(i) RJBrandsLLCcertifiesthatasofthedateoftheapplicationtheequipmentforwhichauthorization issoughtisnotâcoveredâequipment 1 prohibitedfromreceivinganequipmentauthorizationpursuant tosection2.903oftheFCCrules. Iftheequipmentforwhichtheapplicantseeksauthorizationisproducedbyanyoftheentities identifiedonthecurrentCoveredList,includingaffiliatesorsubsidiariesofthenamedcompanies,the applicantmustincludeanexplanationonwhytheequipmentisnotâcoveredâequipment. AdditionalExplanation:<N/A> Statementfor47CFRsection2.911(d)(5)(ii) RJBrandsLLC(âtheapplicantâ)certifiesthat,asofthedateofthefilingofthisapplication,the applicantâ-is/â-isnot identifiedontheCoveredListasanentityproducingâcoveredâequipment. Thankyou, By:____ThomasTinelli__ (Signature 2 )(Printname) Title: _____ R egulatory M anager________ Company:_RJBrandsLLC_Telephone:(845)218-8701_______ 1 -TheCommissionâsCoveredListispublishedbythePublicSafetyandHomelandSecurityBureauandpostedontheCommissionâswebsite.This CoveredList,whichisperiodicallyupdated,identifiesparticularequipment,producedbyparticularentities,thatconstitutesâcoveredâequipment. https://www.fcc.gov/supplychain/coveredlist. 2 -Lettersshouldbeplacedonappropriateletterhead.
RJBrandsLLC TO:AmericanCertificationBody,Inc. 313ParkAvenue Suite300 FallsChurch,VA22046 ATTENTION:FCCCertificationâSection2.911(d)(7)Information ThisletteristoconfirmthattheApplicantwillalsoserveastheU.S.AgentforServiceof Processasrequiredby47CFR2.911(d)(7).TheApplicantacknowledgesthatthey mustmaintainanagentfornolessthanoneyearafterterminatingallmarketingand importationORtheconclusionofanyCommission-relatedproceedinginvolvingthe equipment.TheApplicantfurtheracknowledgestheirresponsibilitytoinformtheFCC whenevertheDesignatedU.S.Agentinformationchanges. Applicant Companyname:RJBrandsLLC FRN#:0031299548 GranteeCode:2A2YP ContactName:ThomasTinelli StreetAddress:200PerformanceDrive,Mahwah,NJ07495USA City/Province/Zip:Mahwah/NewJersey/07430 TelephoneNo:(845)218-8701 Email:[email protected] ApplicantSignature 1 : Date:7/14/23 Signedby(PrintedName/Title):ThomasTinelli/RegulatoryManager 1 - Lettersmustbeplacedonappropriateletterhead.
RJBrandsLLC 030122-15 AuthoritytoActasAgent Date:July17,2023 AmericanCertificationBody,Inc. 313ParkAvenue Suite300 FallsChurch,VA22046 ToWhomItMayConcern: IntertekTestingServicesShanghai 1 isauthorizedtoactonourbehalf,untilotherwisenotified,for applicationstoAmericanCertificationBody,Inc.(ACB). Wecertifythatwearenotsubjecttodenialoffederalbenefits,thatincludesFCCbenefits,pursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.862.Further,noparty,asdefinedin47 CFR1.2002(b),totheapplicationissubjecttodenialoffederalbenefits,thatincludesFCCbenefits. WealsodeclarethattheinformationprovidedtotheFCCistrueandcorrecttothebestofour knowledge(47CFR2.911(d))andwehavebeeninformedofthegranteeresponsibilities(47CFR 2.909)withregardtocertifiedequipment. Thankyou, AgencyAgreementExpirationDate:_____2024/7/12_____ By:ThomasTinelli_ (Signature 2 )(Printname) Title:____RegulatoryManager______ Onbehalfof:RJBrandsLLC_ (CompanyName) Telephone:_(845)218-8701_ 1 -Ifagroupâentityâisdesignatedastheauthorizedagent,theletterofauthorizationmustidentifythoseindividualswithinthegroup whoareauthorizedtotakeactionontheapplication;oralternativelyastatementmustbeprovidedindicatingthatastheauthorized agent,anyindividualwithinthegroupâentityâisauthorizedtoactonbehalfoftheapplicant/granteeandtakeactiononthe application.See https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=33316. 2 -MustbesignedbyapplicantcontactgivenforapplicantontheFCCsite,orbytheauthorizedagentifanappropriateauthorizedagent letterhasbeenprovided.Lettersshouldbeplacedonappropriateletterhead.
RJBrandsLLC 030122-15 RequestforConfidentiality Date:July17,2023 Subject:ConfidentialityRequestfor:_____FCCID:2A2YP-CQ60QPROBE PursuanttoFCC47CFR0.457(d)and0.459andICRSP-100,Section12.4,theapplicantrequeststhatapartofthe subjectFCCapplicationbeheldconfidential. TypeofConfidentialityRequestedExhibit âShortTermâPermanentBlockDiagrams âShortTermExternalPhotos âShortTermâPermanent* 1 InternalPhotos âShortTermâPermanentOperationDescription/TheoryofOperation âShortTermâPermanentPartsList&Placement/BOM âShortTermâPermanentTune-UpProcedure âShortTermâPermanentSchematics âShortTermTestSetupPhotos âShortTermâPermanent* 3 UserâsManual __RJBrandsLLC_hasspentsubstantialeffortindevelopingthisproductanditisoneofthefirstofitskindin industry.Havingthesubjectinformationeasilyavailableto"competition"wouldnegatetheadvantagetheyhave achievedbydevelopingthisproduct.Notprotectingthedetailsofthedesignwillresultinfinancialhardship. PermanentConfidentiality: Theapplicantrequeststheexhibitslistedaboveaspermanentlyconfidentialbepermanentlywithheldfrompublic reviewduetomaterialsthatcontaintradesecretsandproprietaryinformationnotcustomarilyreleasedtothepublic. Short-TermConfidentiality: Theapplicantrequeststheexhibitsselectedaboveasshorttermconfidentialbewithheldfrompublicviewfora periodof___(specifynumberofdaysnottoexceed180) 2 ___daysfromthedateoftheGrantofEquipment Authorizationandpriortomarketing.Thisistoavoidprematurereleaseofsensitiveinformationpriortomarketing orreleaseoftheproducttothepublic.ApplicantisalsoawarethattheyareresponsibletonotifyACBintheevent informationregardingtheproductortheproductismadeavailabletothepublicbeforetherequestedperiodhas expired.ACBwillthenreleasethedocumentslistedaboveforpublicdisclosurepursuanttoFCCPublicNoticeDA 04-1705. NOTEforIndustryCanadaApplications: ICcurrentlyonlydistinguishesPermanentConfidentialityexhibitsasshownabove.ShortTermconfidentialityisnot consideredapplicabletoICapplications. Sincerely, By:______ThomasTinelli_ (Signature/Title 3 )(Printname) 1 -Theasteriskeditems(*)requirefurtherinformationtobeprovidedtoACBbeforepermanentconfidentialitywillbeextendedtothese exhibits.PleaserefertoFCCKDB726920andthespecificDocumentlinkforD01foundat: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731andreviewsectionII,3)regardingspecific informationthatmustaccompanytheserequests. 2 -Pleaserefertohttps://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdfforcompletedetails. 3 -MustbesignedbyapplicantcontactgivenforapplicantontheFCCsite,orbytheauthorizedagentifanappropriateauthorizedagent letterhasbeenprovided.Lettersshouldbeplacedonappropriateletterhead.
DECLARATION We,RJBrandsLLCdeclare Ourcompanyâsproject Model:CQ60-QPR-01/CQ60-QPR-02/CQ60-QPR-03 aresame, Exceptdifferentofdecalnumber/colorontheceramichandle Theabove-mentionedstatementsofourcompanyaretotallytrue.Iffalse, wewillbearcorrespondingliability. Date:July13,2023 --------------------------- ThomasTinelli RJBrandsLLC Tel:(845)218-8701 Email:[email protected] Smart Thermometer CHEF PROBE
Page 1 of 4 External Photos Page 2 of 4 CQ60-QPR-01 Page 3 of 4 CQ60-QPR-02 Page 4 of 4 CQ60-QPR-03 *************************************** END ***************************************
Step 1: Step 2: Step 3:
Step 1: Step 2: Step 3:
Step 1: Step 2: Step 3:
Page 1 of 8 Internal Photos Page 2 of 8 CQ60-QPR-01 Page 3 of 8 Page 4 of 8 CQ60-QPR-02 Page 5 of 8 Page 6 of 8 CQ60-QPR-03 Page 7 of 8 Page 8 of 8 *************************************** END ***************************************
RJ Brands LLC MPE ASSESSMENT REPORT Report Type: FCC Part §2.1091, §2.1093 and §1.1307(b) assessment report Model: CQ60-QPR-01,CQ60-QPR-02,CQ60-QPR-03 REPORT NUMBER: 230302238SHA-002 ISSUE DATE: July 13, 2023 DOCUMENT CONTROL NUMBER: TTRFFCCMPE-01_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRFFCCMPE-01_V1© 2018 Intertek Page 2 of 8 Report no.: 230302238SHA-002 Applicant: RJ Brands LLC 200 Performance Drive,Mahwah,NJ 07495 USA Manufacturer: RJ Brands LLC 200 Performance Drive,Mahwah,NJ 07495 USA Manufacturer Site: Chefman Smart Tech (Hangzhou) Co., Ltd Dalu Industrial Park, Hangzhou City, Zhejiang Province Product Name: Smart Thermometer CHEF PROBE Type/Model: CQ60-QPR-01,CQ60-QPR-02,CQ60-QPR-03 FCC ID: 2A2YP-CQ60QPROBE SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: KDB447498 D01 General RF Exposure Guidance v06 FCC Part2.1091, FCC Part2.1093 FCC Part1.1307(b) PREPARED BY: REVIEWED BY: Project Engineer Dylan Tang Reviewer Wakeyou Wang Report No.: 230302238SHA-002 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 3 of 8 Revision History Report No. Version Description Issued Date 230302238SHA-002 Rev. 01 Initial issue of report July 13, 2023 Report No.: 230302238SHA-002 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 4 of 8 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test (EUT) Product name: Smart Thermometer CHEF PROBE Type/Model: CQ60-QPR-01, CQ60-QPR-02, CQ60-QPR-03 Description of EUT: The EUT is Smart Thermometer CHEF PROBE, it supports Bluetooth function. The differences between CQ60-QPR-01 CQ60-QPR-02 and CQ60-QPR-03 is that the decal number/color on the ceramic handle. the models PCB layout and circuit design is the same. so choose CQ60- QPR-01 to test as representative. Rating: DC 3V, 0.03A Category of EUT: Class B EUT type: Table top Floor standing Product Marketing Name: CQ60-QPR-01, CQ60-QPR-02, CQ60-QPR-03 HVIN: CQ60-QPR-01, CQ60-QPR-02, CQ60-QPR-03 Software Version: V2.0.0 Hardware Version: B Serial numbers: 0230708-12-001(for radiation sample), 0230708-12-002(for conduction sample) Sample received date: March 25, 2023 Date of test: March 25, 2023~ July 6, 2023 1.2 Technical Specification Frequency Range: 2402-2480MHz Support Standards: IEEE 802.15.1 Type of Modulation: GFSK Channel Number: 3 Data Rate: 1Mbps Antenna Information: -13.71dBi, Metal antenna Report No.: 230302238SHA-002 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 5 of 8 1.3 Description of Test Facility Name: Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Telephone: 86 21 61278200 Telefax: 86 21 54262353 The test facility is recognized, certified, or accredited by these organizations: CNAS Accreditation Lab Registration No. CNAS L0139 FCC Accredited Lab Designation Number: CN0175 IC Registration Lab CAB identifier.: CN0014 VCCI Registration Lab Registration No.: R-14243, G-10845, C-14723, T-12252 A2LA Accreditation Lab Certificate Number: 3309.02 Report No.: 230302238SHA-002 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 6 of 8 2 MPE Assessment Test result: Pass 2.1 MPE Assessment Limit Mobile device exposure for standalone operations: Frequency range E-field strength (V/m) H-field strength (A/m) B-field (uT) Equivalent plane wave power density S eq (W/m 2 ) 0-1 Hz - 3,2 Ă 10 4 4 Ă 10 4 - 1-8 Hz 10 000 3,2 Ă 10 4 /f 2 4 Ă 10 4 /f 2 - 8-25 Hz 10 000 4 000/f 5 000/f - 0,025-0,8 kHz 250/f 4/f 5/f - 0,8-3 kHz 250/f 5 6,25 - 3-150 kHz 87 5 6,25 - 0,15-1 MHz 87 0,73/f 0,92/f - 1-10 MHz 87/f 1/2 0,73/f 0,92/f - 10-400 MHz 28 0,073 0,092 2 400-2 000 MHz 1,375 f 1/2 0,0037 f 1/2 0,0046 f 1/2 f/200 2-300 GHz 61 0,16 0,20 10 Mobile device exposure for simultaneous transmission operations: the sum of the MPE ratios for all simultaneously transmitting antennas incorporated in a host device is †1.0 Report No.: 230302238SHA-002 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 7 of 8 2.2 Assessment Results Power density (S) is calculated according to the formula: S = PG / (4ÏRÂČ) Where S = power density in mW/cmÂČ P = Radiated transmit power in mW G = numeric gain of transmit antenna R = distance (cm) As we can see from the test report: 230302238SHA-001. The calculations in the table below use the highest gain of antenna for client EUT. These calculations represent worst case in terms of the exposure levels. The calculations in the table below use the highest gain of antenna for client EUT. These calculations represent worst case in terms of the exposure levels. Frequency band Power Antenna Gain R S Limits (MHz) dBm mW dBi (Numeric) (cm) (mW/cm2) (mW/cm2) 2402 â 2480 -10.6 0.087 -13.71 0.043 20 0.000007 1 Note: 1 mW/cm2 from 1.310 Table 1. Report No.: 230302238SHA-002 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 8 of 8 Appendix I Definition below must be outlined in the User Manual: To satisfy FCC RF exposure requirements, a separaâŠ
Text truncated - open the document above for the full version.
Smart Thermometer CHEF PROBE Antenna Test Report ANT Property BLE Antenna Type Input impedance Frequency Band Peak Gain Metal Antenna 50Ω 2.4~2.5GHz -13.71dBi ANT Efficiency Type Type Frequency (MHz) Efficiency(%) Gain(dB) 2402 2426 2480 1.24642 1.0343 1.11017 -14.055 -13.9293 -13.7096 ANT Directivity Pattern âąAntenna 3D @2402MHz ANT Directivity Pattern âąAntenna 3D @2426MHz ANT Directivity Pattern âąAntenna 3D @2480MHz Manufacturer RJ Brands LLC 200 Performance Drive,Mahwah,NJ07495 USA
Page 1 of 21 Appendix A: DTS Bandwidth Test Result Test Mode Antenna Frequency [MHz] DTS BW [MHz] FL[MHz] FH[MHz] Limit [MHz] Verdict BLE_1M Ant1 2402 0.704 2401.632 2402.336 0.5 PASS 2426 0.724 2425.612 2426.336 0.5 PASS 2480 0.704 2479.612 2480.316 0.5 PASS Page 2 of 21 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2426 Page 3 of 21 BLE_1M_Ant1_2480 Page 4 of 21 Appendix B: Occupied Channel Bandwidth Test Result Test Mode Antenna Frequency [MHz] OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0876 2401.4446 2402.5322 --- --- 2426 1.0763 2425.4394 2426.5157 --- --- 2480 1.0641 2479.4476 2480.5117 --- --- Page 5 of 21 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2426 Page 6 of 21 BLE_1M_Ant1_2480 Page 7 of 21 Appendix C: Maximum conducted output power Test Result Peak Test Mode Antenna Frequency [MHz] Conducted Peak Powert[dBm] EIRP [dBm] Conducted Limit[dBm] Verdict BLE_1M Ant1 2402 -14.96 -28.67 â€30 PASS 2426 -12.16 -25.87 â€30 PASS 2480 -10.60 -24.31 â€30 PASS Test Graphs Peak BLE_1M_Ant1_2402 BLE_1M_Ant1_2426 Page 8 of 21 BLE_1M_Ant1_2480 Page 9 of 21 Appendix D: Maximum power spectral density Test Result Test Mode Antenna Frequency[MHz] Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -32.30 â€8.00 PASS 2426 -29.77 â€8.00 PASS 2480 -28.34 â€8.00 PASS Page 10 of 21 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2426 Page 11 of 21 BLE_1M_Ant1_2480 Page 12 of 21 Appendix E: Band edge measurements Test Result Test Mode Antenna ChName Frequency [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict BLE_1M Ant1 Low 2402 -16.66 -58.58 â€-36.66 PASS High 2480 -12.16 -57.52 â€-32.16 PASS Page 13 of 21 Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 Page 14 of 21 Appendix F: Conducted Spurious Emission Test Result Test Mode Antenna Frequency [MHz] FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference -15.81 -15.81 --- PASS 30~1000 -15.81 -58.63 â€-35.81 PASS 1000~26500 -15.81 -51.4 â€-35.81 PASS 2426 Reference -13.08 -13.08 --- PASS 30~1000 -13.08 -51.91 â€-33.08 PASS 1000~26500 -13.08 -51.7 â€-33.08 PASS 2480 Reference -11.54 -11.54 --- PASS 30~1000 -11.54 -52.05 â€-31.54 PASS 1000~26500 -11.54 -51.31 â€-31.54 PASS Page 15 of 21 Test Graphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 Page 16 of 21 BLE_1M_Ant1_2402_1000~26500 BLE_1M_Ant1_2426_0~Reference Page 17 of 21 BLE_1M_Ant1_2426_30~1000 BLE_1M_Ant1_2426_1000~26500 BLE_1M_Ant1_2480_0~Reference Page 18 of 21 BLE_1M_Ant1_2480_30~1000 BLE_1M_Ant1_2480_1000~26500 Page 19 of 21 Appendix G: Duty Cycle Test Result Test Mode Antenna Frequency [MHz] ON Time [ms] Period [ms] Duty Cycle [%] Duty Cycle Factor[dB] BLE_1M Ant1 2402 10.42 10.51 99.14 0.04 2426 10.42 10.50 99.24 0.03 2480 10.42 10.50 99.24 0.03 Page 20 of 21 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2426 Page 21 of 21 BLE_1M_Ant1_2480
RJ Brands LLC RF TEST REPORT Report Type: FCC Part 15.247 & ISED RSS-247 RF report Model: CQ60-QPR-01,CQ60-QPR-02,CQ60-QPR-03 REPORT NUMBER: 230302238SHA-001 ISSUE DATE: July 13, 2023 DOCUMENT CONTROL NUMBER: TTRF15.247-02_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.247-02_V1 © 2018 Intertek Page 2 of 28 Report no.:230302238SHA-001 Applicant: RJ Brands LLC 200 Performance Drive,Mahwah,NJ 07495 USA Manufacturer: RJ Brands LLC 200 Performance Drive,Mahwah,NJ 07495 USA Manufacturer Site: Chefman Smart Tech (Hangzhou) Co., Ltd Dalu Industrial Park, Hangzhou City, Zhejiang Province Product Name: Smart Thermometer CHEF PROBE Type/Model: CQ60-QPR-01,CQ60-QPR-02,CQ60-QPR-03 FCC ID: 2A2YP-CQ60QPROBE IC: 27740-CQ60QPROBE SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2021): Radio Frequency Devices (Subpart C) ANSI C63.10 (2020): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-247 Issue 2 (February 2017): Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices RSS-Gen Issue 5 (February 2021) Amendment 2: General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Project Engineer Dylan Tang Reviewer Wakeyou Wang Report No.:230302238SHA-001 TEST REPORT TTRF15.247-02_V1 © 2018 Intertek Page 3 of 28 Content REVISION HISTORY................................................................................................................................................ 5 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 6 1 GENERAL INFORMATION ............................................................................................................................. 7 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 7 1.2 TECHNICAL SPECIFICATION .................................................................................................................................... 7 1.3 DESCRIPTION OF TEST FACILITY .............................................................................................................................. 8 2 TEST SPECIFICATIONS ................................................................................................................................... 9 2.1 STANDARDS OR SPECIFICATION ............................................................................................................................... 9 2.2 MODE OF OPERATION DURING THE TEST ................................................................................................................... 9 2.3 TEST SOFTWARE LIST .......................................................................................................................................... 10 2.4 TEST PERIPHERALS LIST ....................................................................................................................................... 10 2.5 TEST ENVIRONMENT CONDITION: .......................................................................................................................... 10 2.6 INSTRUMENT LIST .............................................................................................................................................. 11 2.7 MEASUREMENT UNCERTAINTY ............................................................................................................................. 12 3 MINIMUM 6DB BANDWIDTH ..................................................................................................................... 13 3.1 LIMIT .............................................................................................................................................................. 13 3.2 MEASUREMENT PROCEDURE ............................................................................................................................... 13 3.3 TEST CONFIGURATION ........................................................................................................................................ 13 3.4 TEST RESULTS OF MINIMUM 6DB BANDWIDTH ....................................................................................................... 13 4 MAXIMUM CONDUCTED OUTPUT POWER AND E.I.R.P. ............................................................................. 14 4.1 LIMIT .............................................................................................................................................................. 14 4.2 MEASUREMENT PROCEDURE ............................................................................................................................... 14 4.3 TEST CONFIGURATION .........âŠ
Text truncated - open the document above for the full version.
Page 1 of 3 Test Setup Page 2 of 3 1. Radiated Emission Below 1GHz Above 1GHz Page 3 of 3 2. Conducted RF Test
Building No.86, 1198 Qinzhou Road(North) · Shanghai · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 87.10 ”W |

CQ60-PR-01,CQ60-PR-02,CQ60-PR-03, CQ60-PR-04,CQ60-PR-05
Equipment Class
DTS - Digital Transmission System