User Guide TF-IFU-PF-v20230413 - Latest revision date: 2023-04-13 [email protected] Perifit Care+ - X6 Innovations 128 rue la Boetie, 75008 Paris, France PERIFIT CARE+ 1. Intended use, intended user description READ ALL INSTRUCTIONS BEFORE USE. Failure to follow the instructions and safety information can lead to injury or damage to the device. 1.1 Intended use Perifit Care+ is a wireless Kegel exerciser intended to increase precision, motivation and regularity of your pelvic floor workouts. Perifit Care+ is composed of a device and an app that form an interactive platform that will guide you through Kegel exercises. Perifit Care+ is intended for: encouraging regular pelvic floor exercises; strengthening of the pelvic floor muscles; rehabilitation and training of weak pelvic floor muscle; treatment of stress, urge and mixed urinary incontinence in women; improving sexual pleasure or function in women with existing pelvic floor dysfunction; improving pelvic floor function in the post-partum period, including improving strength, reducing dysfunction, reducing urinary incontinence and improving sexual function; improving mild to moderate prolapse symptoms. 1.2 Intended Users Perifit Care+ is intended for vaginal use by adults. The body of the probe is meant to be inserted into the user's vagina. The Perifit Care+ is intended for a single user only and is not to be shared. The PATIENT is an intended OPERATOR. 1.3 Description Perifit Care+ is a wireless Kegel exerciser intended to increasepre- cision, motivation and regularity of your pelvic floor workouts. - Do not use Perifit Care+ if some of its electronic parts are visible. - Do not use the Perifit Care+ if it feels hot to the touch or if the Perifit Care+ is overheating. - Do not use Perifit Care+ if you experience persistent pain when inserting or using Perifit Care+, even with water-based lubricant. In order to avoid muscle pain: - Do not use Perifit Care+ anally - Do not overtrain. Read Section 3.2 ("How often and for how long should I train?") for guidelines on training session duration. If you feel muscle soreness after using Perifit, please reduce the duration and frequency of your sessions. If the pain worsens or persists, please reach out to a qualified health professional for advice - Make sure you have inserted the Perifit Care+ correctly. Read Section 3.6 ("Using Perifit Care+") before beginning to train. In order to protect your device and reduce risk of explosions: - No modifications to the Perifit Care+ should be made. Do not take apart the Perifit Care+ nor use the Perifit Care+ if it has been re-assembled by any person other than a technician authorized by the manufacturer. Doing so may lead to injury - Do not boil, microwave, or clean Perifit Care+ in the dishwasher - Do not use Perifit Care+ in the bath or shower - Avoid extreme heat (above 40°C/104°F), extreme cold (below 0°C/32°F), or pressure outside of the range from 700 hPa to 1060 hPa. If you experience any of the symptoms mentioned above or have any questions, please reach out to support in the app by clicking on the "?" or via email to [email protected] 2.4 Symbol legend See symbol legend page 15. 3. Product Information 3.1 Your Device See diagram 16. Perifit Care+ contains a battery and is not chargeable. It allows for 5+ years of training. Please refer to the Warranty section of your User Guide for further information. Perifit Care+ is made from medical grade silicone. Battery voltage: 3V / Battery capacity: 220mAh. Perifit Care+ is composed of a device and an app that form an interactive platform that will guide you through Kegel exercises. It helps users to perform Kegel exercises that may improve bladder control, pelvic floor muscle strength and sexual pleasure. Perifit Care+ has three main functions: - It allows users to visualize their pelvic floor contractions on the screen of their smartphone through visual biofeedback. - It makes Kegel exercises fun and entertaining and helps keep track of the user’s progress - It provides training programs that facilitate effective pelvic floor muscle exercise by following the training principles of specificity and progression Perifit Care+ gamifies your Kegel routine and provides guidance for your workouts. It detects the force exerted by pelvic floor muscle contractions and allows the user to visualize this information in real time via smartphone. Using the device and corresponding app is like having a personalized coach giving the necessary motivation and live feedback to help you step up your pelvic floor workouts. 1.4 Benefits related to the use of Perifit Care+ The pelvic floor is composed of several layers of muscles which provide pelvic organ support; passage for the urinary, genital, and digestive tracts; ensure urinary and anal continence while also allowing voiding and defecation; and can accommodate sexual intercourse, pregnancy and delivery. Dysfunction of the pelvic floor may develop after specific events (such as weakness following pregnancy or delivery), or may be progressive and idiopathic in nature (such as the development of urinary incontinence with advancing age). Strengthening of the pelvic floor muscles through Kegel exercises is recommended as first-line conservative treatment for a variety of pelvic floor disorders. The Perifit Care+ is an adjunct to pelvic floor muscle training. Benefits related to pelvic floor muscle training include: - Improving overall pelvic floor muscle fitness (such as muscular strength and endurance); - Treatment or reduction in symptoms of stress, urge, and mixed urinary incontinence; - Improving sexual pleasure or function in women with existing pelvic floor dysfunction; - Improving pelvic floor function in the post-partum period, including improving strength, reducing dysfunction, reducing urinary incontinence, and improving sexual function; - Improving mild to moderate prolapse symptoms. 2. Safety Information Perifit Care+ is not intended to diagnose any medical …
Text truncated - open the document above for the full version.
X6 Innovations SAS The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 5/27/2023 U.S. Agent Designation [X6 Innovations SAS] acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: :2A338-X6002 ): Name of U.S. agent contact person: Tim Payne Company U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] Phone of U.S. agent: 708-571-3148 FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of [X6 Innovations SAS]. [X6 Innovations SAS] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). Sincerely, Signature David Thibault Hardware Manager X6 Innovations SAS Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7) - U, V03
Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: X6 Innovations SAS Address: 128 rue la Boetie 75008 Paris FRANCE Phone: 33625455078 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-04-28 Printed Name of Signee: David Thibault Company: X6 Innovations SAS Address: 128 rue la Boetie 75008 Paris FRANCE Phone: 33625455078 Fax: 33625455078 Email: [email protected]
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2A338-X6002 Perifit Care+ We, applicant Company Name: X6 Innovations SAS Address: 128 rue la Boetie 75008 Paris FRANCE Phone: 33625455078 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-04-28 Printed Name of Signee: David Thibault Company: X6 Innovations SAS Address: 128 rue la Boetie 75008 Paris FRANCE Phone: 33625455078 Fax: 33625455078 Email: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2A338-X6002 Perifit Care+ For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: the Operational Description the Block Diagram the Schematics The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-04-28 Printed Name of Signee: David Thibault Company: X6 Innovations SAS Address: 128 rue la Boetie 75008 Paris FRANCE Phone: 33625455078 Fax: 33625455078 Email: [email protected]
Page 1 of 3 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6
Page 1 of 1 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L: 2.0cm x w: 3.0cm) Label Location Wireless kegel exerciser Model: Perifit Care+ FCC ID:2A338-X6002 IC:28069-X6002
Page 1 of 4 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 BT ANT Page 2 of 4 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7
Page 1 of 3 FCC ID:2A338-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2A338-X6002 Product name : Wireless kegel exerciser Test Model : Perifit Care+ Power Supply : DC 3V By CR2032 Button Cell Hardware Version : v0.3 Software Version : 4.13.0 Bluetooth Frequency Range : 2402MHz~2480MHz Channel Number : 40 channels for Bluetooth V4.2(DTS) Channel Spacing : 2MHz for Bluetooth V4.2(DTS) Modulation Type : GFSK for Bluetooth V4.2(DTS) Bluetooth Version : V4.2 Antenna Description : Internal Antenna, 0.39dBi(Max.) Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device Page 2 of 3 FCC ID:2A338-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices Page 3 of 3 FCC ID:2A338-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. Conducted Power Results < BLE_1M > Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 0.41 19 2440 0.63 39 2480 0.34 5. Manufacturing Tolerance < BLE > GFSK (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 0 0 0 Tolerance ±(dB) 1.0 1.0 1.0 6. Evaluation Results 6.1 Standalone Evaluation Band/Mode Frequency (GHz) Antenna Distance (mm) RF output power SAR Test Exclu…
Text truncated - open the document above for the full version.
深圳勤新科技有限公司 Model/ Customer :Qinxin_V1_IPEX1_1.13_0.8PA-L70 Date:2023年04月15日 project leader: 黄文博(15981667202) Antenna Test Report 深圳勤新科技有限公司 •Antenna characteristics using ETS test system microwave chamber, microwave chamber size 7m x 4m x 3m, test frequency 700 MHz- - -6GHz. S11 test using Agilent E5071B network analyzer Testing environment Microwave room Agilent E5071B network analyzer 深圳勤新科技有限公司 ØAntenna Frequency range: ØBT 2.4G Specification 深圳勤新科技有限公司 Antenna passive data 深圳勤新科技有限公司 VSWR Radiation Pattern Phi 0 2D Phi 90 2D Theta 90 2D 深圳勤新科技有限公司 Antenna specifications
Page 1 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BLE (Conducted Measurement) Product Name: Wireless kegel exerciser Test Model: Perifit Care+ Environmental Conditions Temperature: 23.1 C Relative Humidity: 52.3% ATM Pressure: 100.0 kPa Test Engineer: Jack Cheng Supervised by: Ling Zhu Page 2 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 2402 Ant 0.7 >=0.5 Pass NVNT BLE 2440 Ant 0.693 >=0.5 Pass NVNT BLE 2480 Ant 0.699 >=0.5 Pass Page 3 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 2402MHz Ant -6dB Bandwidth NVNT BLE 2440MHz Ant Page 4 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 2480MHz Ant Page 5 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Occupied Channel Bandwidth Condition Mode Frequency (MHz) Antenna 99% OBW (MHz) NVNT BLE 2402 Ant 1.062 NVNT BLE 2440 Ant 1.067 NVNT BLE 2480 Ant 1.068 Page 6 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs OBW NVNT BLE 2402MHz Ant OBW NVNT BLE 2440MHz Ant Page 7 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity OBW NVNT BLE 2480MHz Ant Page 8 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT BLE 2402 Ant 0.41 30 Pass NVNT BLE 2440 Ant 0.63 30 Pass NVNT BLE 2480 Ant 0.34 30 Pass Page 9 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 2402MHz Ant Power NVNT BLE 2440MHz Ant Page 10 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 2480MHz Ant Page 11 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 2402 Ant -14.73 8 Pass NVNT BLE 2440 Ant -14.58 8 Pass NVNT BLE 2480 Ant -14.83 8 Pass Page 12 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 2402MHz Ant PSD NVNT BLE 2440MHz Ant Page 13 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT BLE 2480MHz Ant Page 14 of 24 FCC ID:2A338-X6002 IC:28069-X6002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park …
Text truncated - open the document above for the full version.
Page 1 of 32 FCC ID:2A338-X6002 Report No.: LCSA013123013EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For X6 Innovations SAS Wireless kegel exerciser Test Model: Perifit Care+ Prepared for : X6 Innovations SAS Address : 128 rue la Boetie 75008 Paris FRANCE Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : February 01, 2023 Number of tested samples : 2 Sample No. : A013123013-1, A013123013-2 Serial number : Prototype Date of Test : February 01, 2023 ~ February 07, 2023 Date of Report : February 09, 2023 Page 2 of 32 FCC ID:2A338-X6002 Report No.: LCSA013123013EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA013123013EA Date of Issue .................................. : February 09, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : X6 Innovations SAS Address .......................................... : 128 rue la Boetie 75008 Paris FRANCE Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No.................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. .......................... : Wireless kegel exerciser Trade Mark ..................................... : N/A Test Model ...................................... : Perifit Care+ Ratings ........................................... : DC 3V By CR2032 Button Cell Result ............................................ : Positive Compiled by: Supervised by: Approved by: Jack Liu/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 32 FCC ID:2A338-X6002 Report No.: LCSA013123013EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected]…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.20 mW |

Perifit Care+
Equipment Class
DTS - Digital Transmission System
Breast Pump
Equipment Class
DTS - Digital Transmission System