FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Abbott Automation Solutions GmbH/
  3. 2A36T-GLP1

2A36T-GLP106Q28-81, 06Q28-91

Abbott Automation Solutions GmbH
06Q28-81,  06Q28-91 - FCC ID 2A36T-GLP1 - Abbott Automation Solutions GmbH
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Nov 21, 2022
Application Purpose
Original Equipment
Date of Application
Nov 21, 2022
Equipment Note
06Q28-81, 06Q28-91
Frequency Range
13.56000000 - 13.56000000
Company
Abbott Automation Solutions GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗
↗
↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗
↗

Operational Description

↗
↗
↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Sample Access Line (SAL) Interface Manual For use with the GLP systems Track Laboratory Automation System and the Sample Access Line 80003970-101 DRAFT Table of contents Read me first................................................................................................................5 General safety information...................................................................................................6 Section 1: Use or function............................................................................................7 Safety features......................................................................................................................8 Throughput...........................................................................................................................9 Bar code reader...................................................................................................................10 AccessPoints........................................................................................................................11 Software..............................................................................................................................12 Section 2: Installation procedures and special requirements......................................13 Transportation, installation, disassembly, and disposal.....................................................14 Sample Access Line installation requirements....................................................................15 Section 3: Principles of operation...............................................................................17 Section 4: Performance characteristics and specifications..........................................19 Section 5: Operating instructions................................................................................21 Section 6: Operational precautions and limitations....................................................23 Section 7: Hazards......................................................................................................25 Safety..................................................................................................................................26 Section 8: Service, maintenance, and diagnostics.......................................................27 Cleaning and maintenance..................................................................................................28 Maintenance checks.................................................................................................28 As-needed cleaning procedures...............................................................................29 Section 9: Troubleshooting.........................................................................................33 Unlock and lock the track hoods.........................................................................................34 Errors and troubleshooting.................................................................................................36 Error with pipetting..................................................................................................37 CAR with sample at AccessPoint, in traffic jam, or in long queue; sample matter has not been removed............................................................................37 CAR with sample does not move to the analyzer.....................................................37 Transport ceased on the track.................................................................................37 Appendix A: Alinity ci-series SAL.................................................................................39 Design and function............................................................................................................40 Operating element...................................................................................................42 Workflow..................................................................................................................42 Signal Lamp..............................................................................................................43 Technical data.....................................................................................................................45 Sample Access Line operation.............................................................................................46 Buttons.....................................................................................................................46 Start screen..............................................................................................................47 Power on the Sample Access Line............................................................................48 Sample Access Line (SAL) Interface Manual 80003970-101 DRAFT - 2022-MM-DD 3 Place the Sample Access Line online........................................................................49 Place the Sample Access Line offline........................................................................49 Pause the Sample Access Line..................................................................................50 Deactivate pause mode............................................................................................50 Restart the Sample Access Line................................................................................51 Main menu screen element descriptions.................................................................52 Login screen.............................................................................................................52 Access the Login screen...........................................................................................53 Information screen element descriptions................................................................54 Access the Information screen..........................................................…

Text truncated - open the document above for the full version.

ID Label/Location Info

SEE ELECTRONIC REVISION HISTORY REPORT SCALE SIZE DWG NO. REV. DO NOT SCALE DRAWING B SHEET 1 OF 1 1/1 ABBOTT DIAGNOSTIC DIVISIONABBOTT LABORATORIES1921 HURD DRIVE IRVING, TEXAS 75038, USA DWN BY: DATE: APPLIED FINISH: None THREADS CLASS 2A OR 2B REMOVE BURRS AND SHARP EDGES .02 MAX. UNLESS OTHERWISE SPECIFIED: DIMENSIONS IN INCHES TOLERANCES ANGULAR ± 2° 63 .XX ± .02 .XXX ± .010 CONFIDENTIAL INFORMATION CONTAINS TRADE SECRET AND/OR CONFIDENTIAL INFORMATION WHICH IS THE PROPERTY OF ABBOTT LABORATORIES. AS PROVIDED BY 21CFR 20.61, DO NOT DISCLOSE TO THE PUBLIC. TITLE: MATERIAL: 2 S. Goldston 07/14/22 NOTES: UNLESS OTHERWISE SPECIFIED PURCHASED LABEL 1. PRINT PER LABEL CONTENT SHOWN. 2 PRINTING SPECIFICATION: INK COLOR - BLACK BACKGROUND - WHITE MATERIAL - 2mil POLYESTER with 1 mil CLEAR OVERCOAT ADHESIVE - 1.8 mil #350 ACRYLIC LABEL SIZE - 2.0 x 1.0 ± .02 CORNER RADIUS - .05 ± .02 ROLL SIZE - 500, MAX INNER DIE CUT: 1.25 x 0.5 ± .02 4. DIE CUT TO LINER. PERFORATING LINER BETWEEN LABELS IS OPTIONAL. PART NUMBER TO BE PRINTED ON THE WASTE MATRIX. 5. LABEL MUST CONFORM TO UL 969 AND SHALL BE UL APPROVED MATERIAL WITH SUPPLIER NAME AND LABEL NAME OR DESIGNATION ON INSIDE OF ROLL CORE. 6. LABEL MUST BE PROCURED FROM UL AUTHORIZED SUPPLIER. 7. REFERENCE S14913. 8. THIS PART IS A U.L. CRITICAL PART. ANY CHANGES TO THIS PART MUST BE APPROVED BY EMC/SAFETY GROUP. 9. THIS PART/ASSEMBLY SHALL BE COMPLIANT PER THE LATEST REVISION OF ABBOTT SPECIFICATION S205053. 2 3 3 SHEET 1 OF 1 1/1 A LABEL, GLP1 FCC - IC ID 80004972-101 (80004972-101) FCC ID: 2A36T-GLP1 IC: 28384-GLP1 21.2 * 45.7 * Fonts: 1) Calibri 8 normal 2) Calibri 7 normal Material requirements: self-adhesive, abrasion-proof, temperature-resistant from -20 to +80°C / Materialanforderungen: Selbstklebend, abriebfest und temperaturbeständig von -20 bis +80°C *: Deviating dimensions require the consent of Abbott / *: Abweichende Maße bedürfen der Zustimmung durch Abbott 1 2 2 A B C D E F A B C D E 1234 4321 FF 0.00 g C Refer to protection notice ISO 16016Replaced by:Replacement for: Title General tolerances Material Scale Standard Cre. Drw. Surface finish DateSignature 1:1 Cre. Part Sheet Weight: 1 / 1 28.10.2020 DIN ISO 2768 - mK NameDateChangeRev. DIN ISO 1302 Article No. Component Label she Revision Appv`d Sale No. WREDEKX12.10.2022 12839 Sachsenkamp 5, 20097 Hamburg 20036519-101 SAL Alinity c End Section Data matrix code 06Q28-81 (20036519-101) (21) (11) (240) S11Cxxxxxx 06Q28-81 YYMMDD (12839 A) 21.2 * 45.7 * Fonts: 1) Calibri 8 normal 2) Calibri 7 normal Material requirements: self-adhesive, abrasion-proof, temperature-resistant from -20 to +80°C / Materialanforderungen: Selbstklebend, abriebfest und temperaturbeständig von -20 bis +80°C *: Deviating dimensions require the consent of Abbott / *: Abweichende Maße bedürfen der Zustimmung durch Abbott 1 2 2 A B C D E F A B C D E 1234 4321 FF 0.00 g C Refer to protection notice ISO 16016Replaced by:Replacement for: Title General tolerances Material Scale Standard Cre. Drw. Surface finish DateSignature 1:1 Cre. Part Sheet Weight: 1 / 1 28.10.2020 DIN ISO 2768 - mK NameDateChangeRev. DIN ISO 1302 Article No. Component Label she Revision Appv`d Sale No. WREDEKX12.10.2022 12840 Sachsenkamp 5, 20097 Hamburg 20036522-101 SAL Alinity i End Section Data matrix code 06Q28-91 (20036522-101) (21) (11) (240) S11Dxxxxxx 06Q28-91 YYMMDD (12840 A)

RF Exposure Info

This report must not be used to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This Report shall not be reproduced, except in full without written approval of the laboratory. Abbott Laboratories GLP12408 SAL Alinity C End Section GLP12409 SAL Alinity I End Section FCC 2.1091:2022 RFID Report: ABBO0080.3 Rev. 2, Issue Date: November 17, 2022 CERTIFICATE OF EVALUATION 2018-09-14 Product compliance is the responsibility of the client; therefore, the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. This report reflects only those tests from the referenced standards shown in the certificate of test. It does not include inspection or verification of labels, identification, marking or user information. As indicated in the Statement of Work sent with the quotation, Element’s standard process is to always use the latest published version of the test methods even when earlier versions are cited in the test specification. Issuance of a purchase order was de facto acceptance of this approach. Otherwise, the client would have advised Element in writing of the specific version of the test methods they wanted applied to the subject testing Last Date of Evaluation: November 17, 2022 Abbott Laboratories EUT: GLP12408 SAL Alinity C End Section GLP12409 SAL Alinity I End Section RF Exposure Evaluation Standards Specification Method FCC 2.1091:2022 FCC 447498 D01 General RF Exposure Guidance v06 Results Method Clause Description Applied Results Comments 7.1 Maximum Permissible Exposure Yes Pass N/A Deviations From Evaluation Standards None Approved By: Donald Facteau, Process Architect Report No. ABBO0080.3 Rev 22/12 REVISION HISTORY 2018.07.17 Revision Number Description Date (yyyy-mm-dd) Page Number 01 Removed Cross Switch 2 Radio 1 and Cross Switch 2 Radio 2. 2021-10-11 6 Updated RF Exposure Condition page and MPE values table to reflect 6 radios instead of 8. 2021-10-11 8, 11 02 Assessment redone to add in the second model variant. 2022-11-14 All Updated power and duty cycle information in the evaluation for the GLP12408 SAL Alinity C End Section. 2022-11-14 10 Report No. ABBO0080.3 Rev 23/12 ACCREDITATIONS AND AUTHORIZATIONS 2021.09.01 United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Each laboratory is accredited by A2LA to ISO / IEC 17025, and as a product certifier to ISO / IEC 17065 which allows Element to certify transmitters to FCC and IC specifications. Canada ISED - Recognized by Innovation, Science and Economic Development Canada as a Certification Body (CB) and as a CAB for the acceptance of test data. European Union European Commission – Recognized as an EU Notified Body validated for the EMCD and RED Directives. United Kingdom BEIS – Recognized by the UK as an Approved Body under the UK Radio Equipment and UK EMC Regulations. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea MSIT / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Israel MOC – Recognized by MOC as a CAB for the acceptance of test data. Hong Kong OFCA – Recognized by OFCA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. SCOPE For details on the Scopes of our Accreditations, please visit: California Minnesota Oregon Texas Washington Report No. ABBO0080.3 Rev 24/12 FACILITIES 2020.12.15 California Labs OC01-17 41 Tesla Irvine, CA 92618 (949) 861-8918 Minnesota Labs MN01-11 9349 W Broadway Ave. Brooklyn Park, MN 55445 (612)-638-5136 Oregon Labs EV01-12 6775 NE Evergreen Pkwy #400 Hillsboro, OR 97124 (503) 844-4066 Texas Labs TX01-09 3801 E Plano Pkwy Plano, TX 75074 (469) 304-5255 Washington Labs NC01-05 19201 120 th Ave NE Bothell, WA 98011 (425)984-6600 A2LA Lab Code: 3310.04 Lab Code: 3310.05 Lab Code: 3310.02 Lab Code: 3310.03 Lab Code: 3310.06 Innovation, Science and Economic Development Canada 2834B-1, 2834B-3 2834E-1, 2834E-3 2834D-1 2834G-1 2834F-1 BSMI SL2-IN-E-1154R SL2-IN-E-1152R SL2-IN-E-1017 SL2-IN-E-1158R SL2-IN-E-1153R VCCI A-0029 A-0109 A-0108 A-0201 A-0110 Recognized Phase I CAB for ISED, ACMA, BSMI, IDA, KCC/RRA, MIC, MOC, NCC, OFCA US0158 US0175 US0017 US0191 US0157 Report No. ABBO0080.3 Rev 25/12 PRODUCT DESCRIPTION 2018-07-17 Client and Equipment Under Evaluation Information Company Name: Abbott Laboratories Address: 6901 Preston Rd City, State, Zip: Plano, TX 75024 Evaluation Requested By: Don Mendell EUT: GLP12408 SAL Alinity C End Section GLP12409 SAL Alinity I End Section Date of Evaluation: 11/14/2022 Information Provided by the Party Requesting the Evaluation Functional Description of the Equipment: The GLP12408 SAL Alinity C End Section is used in conjunction with the GLP12409 SAL Alinity I End Section. The GLP12408 module contains one (1) access point (one (1) RFID reader), one (1) Convergent Switch (two (2) RFID readers), one (1) Cross Switch (two (2) RFID readers), one (1) Divergent Switch (one (1) RFID reader) The GLP12409 module contains one (1) access point (one (1) RFID reader), one (1) Convergent Switch (two (2) RFID readers), one (1) Cross Switch (two (2) RFID readers), one (1) Divergent Switch (one (1) RFID reader) The radios are momentarily triggered for 60ms and are considered standal…

Text truncated - open the document above for the full version.

Test Report

This report must not be used to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This Report shall not be reproduced, except in full without written approval of the laboratory. EAR-Controlled Data - This document contains technical data whose export and reexport/retransfer is subject to control by the U.S. Department of Commerce under the Export Administration Act and the Export Administration Regulations. The Department of Commerce’s prior written approval may be required for the export or re- export/retransfer of such technical data to any foreign person, foreign entity or foreign organization whether in the United States or abroad. Abbott Laboratories GLP12408 SAL Alinity C End Section GLP12409 SAL Alinity I End Section FCC 15.225:2022 13.56 MHz Report: ABBO0080.0 Rev. 5, Issue Date: November 17, 2022 CERTIFICATE OF TEST 2018-09-14 Product compliance is the responsibility of the client; therefore, the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. This report reflects only those tests from the referenced standards shown in the certificate of test. It does not include inspection or verification of labels, identification, marking or user information. As indicated in the Statement of Work sent with the quotation, Element’s standard process is to always use the latest published version of the test methods even when earlier versions are cited in the test specification. Issuance of a purchase order was de facto acceptance of this approach. Otherwise, the client would have advised Element in writing of the specific version of the test methods they wanted applied to the subject testing. Last Date of Test: October 20, 2022 Abbott Laboratories EUT: GLP12408 SAL Alinity C End Section GLP12409 SAL Alinity I End Section Radio Equipment Testing Standards Specification Method FCC 15.207:2022 ANSI C63.10:2013 FCC 15.225:2022 *Previous data has been reviewed to the latest standard and remains in compliance. Results Method Clause Test Description Applied Results Comments 6.2 Powerline Conducted Emissions Yes Pass 6.4 Field Strength of Fundamental Yes Pass 6.4 Field Strength of Spurious Emissions (Less Than 30 MHz) Yes Pass 6.5 Field Strength of Spurious Emissions (Greater Than 30 MHz) Yes Pass 6.8 Frequency Stability Yes Pass 6.9 Occupied Bandwidth Yes Pass Deviations From Test Standards None Approved By: Adam Bruno, Operations Manager Report No. ABBO0080 Rev 52/137 REVISION HISTORY 2018.07.17 Revision Number Description Date (yyyy-mm-dd) Page Number 01 Removed track radio data from Field Strength of Fundamental and added the “segment” cross switch 2021-09-02 69-90 Changed Powerline CE spec from Class A to FCC 15.209 and added the “segment cross switch 2021-09-02 19-68 02 Adjusted print area, Removed CrossSwitch 2 (Basic Kit) data from report. 2021-09-20 69-90 03 Combine both the “C” and “I” End Section variants into one report. 2022-06-23 Throughout report. Added configurations ABBO0182-1, ABBO0080-2 2022-06-23 N/A 04 Updated test dates 2022-10-21 2, 10, 18 Updated configurations 2022-10-21 12-17 Deleted photos in Powerline Conducted Emissions 2022-10-21 N/A Updated the power settings based on information provided by the customer 2022-10-21 11 Updated the diagram 2022-10-21 7-9 05 Updated configurations to only include ABBO0080-2 , ABBO0181-4, ABBO0182-4 2022-11-17 12-17 Updated configuration ABBO0080-2. 2022-11-17 12-13 Updated ABBO0181 data to reference configuration ABBO0181-4. 2022-11-17 44, 45, 47, 49, 51, 53, 55, 57, 59, 61, 63, 65, 67, 80, 81, 83, 85, 87, 89, 94, 95, 100, 101 Updated ABBO0182 data to reference configuration ABBO0182-4. 2022-11-17 19, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 69, 70, 72, 74, 76, 78, 91, 92, 97, 98 Corrected serial numbers in ABBO0181 and ABBO0182 data sheets. 2022-11-17 19-102 Report No. ABBO0080 Rev 53/137 ACCREDITATIONS AND AUTHORIZATIONS 2021.09.01 United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Each laboratory is accredited by A2LA to ISO / IEC 17025, and as a product certifier to ISO / IEC 17065 which allows Element to certify transmitters to FCC and IC specifications. Canada ISED - Recognized by Innovation, Science and Economic Development Canada as a Certification Body (CB) and as a CAB for the acceptance of test data. European Union European Commission – Recognized as an EU Notified Body validated for the EMCD and RED Directives. United Kingdom BEIS – Recognized by the UK as an Approved Body under the UK Radio Equipment and UK EMC Regulations. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea MSIT / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Israel MOC – Recognized by MOC as a CAB for the acceptance of test data. Hong Kong OFCA – Recognized by OFCA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. SCOPE For details on the Scopes of our Accreditations, please visit: California Minnesota Oregon Texas Washington Report No. ABBO0080 Rev 54/137 FACILITIES 2020.12.15 California Labs OC01-17 41 Tesla Irvine, CA 92618 (949) 861-8918 Minnesota Labs MN01-11 9349 W Broadway Ave. Brooklyn Park, MN 55445 (612)-638-5136 Oregon Labs EV01-12 6775 NE Ev…

Text truncated - open the document above for the full version.

Test Report

POWERLINE CONDUCTED EMISSIONS WTD.2022.02.22.0 EmiR5 2022.07.06.0 PSA-ESCI 2022.08.23.0 TEST DESCRIPTION The EUT will be powered either directly or indirectly from the AC power line. Therefore, conducted emissions measurements were made on the AC input of the EUT, or on the AC input of the device used to power the EUT. The EUT was transmitting at its maximum data rate. For each mode, the spectrum was scanned from 150 kHz to 30 MHz. The test setup and procedures were in accordance with ANSI C63.10. In the event that the operating frequency of 13.56 MHz is causing the product to fail the FCC 15.207 limits, the following guidance can be used: FCC KDB 174176 D01 AC Conducted FAQ v01r01, June 3, 2015 Section Q5: For a device with a permanent or detachable antenna operating at or below 30 MHz, the FCC will accept measurements performed with a suitable dummy load in lieu of the antenna under the following conditions: (1) perform the AC power-line conducted tests with the antenna connected to determine compliance with Section 15.207 limits outside the transmitter's fundamental emission band; (2) retest with a dummy load in lieu of the antenna to determine compliance with Section 15.207 limits within the transmitter's fundamental emission band. For a detachable antenna, remove the antenna and connect a suitable dummy load to the antenna connector. For a permanent antenna, remove the antenna and terminate the RF output with a dummy load or network which simulates the antenna in the fundamental frequency band. All measurements must be performed as specified in clause 6.2 of ANSI C63.10-2013. TEST EQUIPMENT Description Manufacturer Model ID Last Cal. Cal. Due LISN Solar Electronics 9252-50-R-24- BNC LJK 2022-08-08 2023-08-08 Power Source/Analyzer Hewlett Packard 6841A THC NCR NCR Receiver Rohde & Schwarz ESR7 ARI 2022-08-30 2023-08-30 Cable - Conducted Cable Assembly Northwest EMC TXA, HFC, TQU TXAA 2022-01-24 2023-01-24 MEASUREMENT UNCERTAINTY Description Expanded k=2 3.1 dB -3.1 dB CONFIGURATIONS INVESTIGATED ABBO0181-4 MODES INVESTIGATED Transmitting 13.56 MHz RFID Report No. ABBO0080 Rev 544/137 POWERLINE CONDUCTED EMISSIONS WTD.2022.02.22.0 EmiR5 2022.07.06.0 PSA-ESCI 2022.08.23.0 EUT: GLP12411 SAL Alinity i End Section Work Order: ABBO0181 Serial Number: SAL12409000010 Date: 2022-10-20 Customer: Abbott Laboratories Temperature: 19.7°C Attendees: Frank Sun Relative Humidity: 33.3% Customer Project: None Bar. Pressure (PMSL): 1018 mb Tested By: Jarrod Brenden Job Site: TX01 Power: 220VAC/60Hz Configuration: ABBO0181-4 TEST SPECIFICATIONS Specification: Method: FCC 15.207:2022 ANSI C63.10:2013 TEST PARAMETERS Run #: 17 Line: High Line Add. Ext. Attenuation (dB): 0 COMMENTS AccessPoint. PCB with single RFID radio. Radio ON. EUT OPERATING MODES Transmitting 13.56 MHz RFID DEVIATIONS FROM TEST STANDARD None 0 10 20 30 40 50 60 70 80 90 100 0.11.010.0100.0 dBuV MHz Quasi Peak Data -vs -Quasi Peak Limit 0 10 20 30 40 50 60 70 80 90 100 0.11.010.0100.0 dBuV MHz Average Data -vs -Average Limit Report No. ABBO0080 Rev 545/137 POWERLINE CONDUCTED EMISSIONS WTD.2022.02.22.0 EmiR5 2022.07.06.0 PSA-ESCI 2022.08.23.0 RESULTS - Run #17 Quasi Peak Data - vs - Quasi Peak Limit Average Data - vs - Average Limit Freq (MHz) Amp. (dBuV) Factor (dB) Adjusted (dBuV) Spec. Limit (dBuV) Margin (dB) Freq (MHz) Amp. (dBuV) Factor (dB) Adjusted (dBuV) Spec. Limit (dBuV) Margin (dB) 13.560 26.4 20.5 46.9 60.0 -13.1 13.560 25.7 20.5 46.2 50.0 -3.8 30.000 11.9 21.8 33.7 60.0 -26.3 30.000 11.6 21.8 33.4 50.0 -16.6 11.452 6.7 20.5 27.2 60.0 -32.8 0.770 0.2 20.2 20.4 46.0 -25.6 0.770 2.9 20.2 23.1 56.0 -32.9 0.670 0.1 20.2 20.3 46.0 -25.7 11.204 6.6 20.5 27.1 60.0 -32.9 11.820 2.9 20.5 23.4 50.0 -26.6 11.699 6.2 20.5 26.7 60.0 -33.3 11.204 2.8 20.5 23.3 50.0 -26.7 0.670 1.7 20.2 21.9 56.0 -34.1 0.247 1.6 20.6 22.2 51.9 -29.7 0.247 4.6 20.6 25.2 61.9 -36.7 17.702 -0.5 20.8 20.3 50.0 -29.7 16.740 2.3 20.8 23.1 60.0 -36.9 4.000 -4.2 20.2 16.0 46.0 -30.0 17.072 1.6 20.8 22.4 60.0 -37.6 3.442 -5.2 20.2 15.0 46.0 -31.0 4.000 -2.5 20.2 17.7 56.0 -38.3 0.950 -5.2 20.1 14.9 46.0 -31.1 4.931 -2.6 20.1 17.5 56.0 -38.5 16.740 -2.1 20.8 18.7 50.0 -31.3 0.950 -3.1 20.1 17.0 56.0 -39.0 2.810 -5.7 20.2 14.5 46.0 -31.5 3.280 -3.6 20.2 16.6 56.0 -39.4 1.516 -5.9 20.1 14.2 46.0 -31.8 21.788 -0.7 21.1 20.4 60.0 -39.6 21.788 -2.9 21.1 18.2 50.0 -31.8 1.516 -4.0 20.1 16.1 56.0 -39.9 2.353 -6.1 20.2 14.1 46.0 -31.9 2.681 -4.1 20.2 16.1 56.0 -39.9 1.268 -6.1 20.0 13.9 46.0 -32.1 1.270 -4.1 20.0 15.9 56.0 -40.1 1.810 -6.5 20.2 13.7 46.0 -32.3 2.236 -4.6 20.2 15.6 56.0 -40.4 0.490 -7.0 20.2 13.2 46.2 -33.0 1.860 -4.9 20.2 15.3 56.0 -40.7 5.350 -3.2 20.1 16.9 50.0 -33.1 5.350 -1.2 20.1 18.9 60.0 -41.1 8.000 -4.0 20.3 16.3 50.0 -33.7 0.566 -5.4 20.2 14.8 56.0 -41.2 7.070 -4.1 20.2 16.1 50.0 -33.9 8.000 -2.4 20.3 17.9 60.0 -42.1 0.410 -6.7 20.3 13.6 47.6 -34.0 0.413 -4.9 20.3 15.4 57.6 -42.2 5.138 -4.2 20.1 15.9 50.0 -34.1 7.208 -2.4 20.2 17.8 60.0 -42.2 0.330 -5.7 20.3 14.6 49.5 -34.9 CONCLUSION Pass Tested By Report No. ABBO0080 Rev 546/137 POWERLINE CONDUCTED EMISSIONS WTD.2022.02.22.0 EmiR5 2022.07.06.0 PSA-ESCI 2022.08.23.0 EUT: GLP12411 SAL Alinity i End Section Work Order: ABBO0181 Serial Number: SAL12409000010 Date: 2022-10-20 Customer: Abbott Laboratories Temperature: 19.7°C Attendees: Frank Sun Relative Humidity: 33.3% Customer Project: None Bar. Pressure (PMSL): 1018 mb Tested By: Jarrod Brenden Job Site: TX01 Power: 220VAC/60Hz Configuration: ABBO0181-4 TEST SPECIFICATIONS Specification: Method: FCC 15.207:2022 ANSI C63.10:2013 TEST PARAMETERS Run #: 18 Line: Neutral Add. Ext. Attenuation (dB): 0 COMMENTS AccessPoint. PCB with single RFID radio. Radio ON. EUT OPERATING MODES Transmitting 13.56 MHz RFID DEVIATIONS FROM TEST STANDARD None 0 10 20 30 40 50 60 70 80 90 100 0.11.010.0100.0 dBuV MHz Quasi Peak Data -vs -Quasi Peak Limit 0 10 20 30 40 50 60 70 80 90 100 0.11.010.0100.0 dBuV MHz Average Data -vs -Average Limit Report No. ABBO0080 Rev 54…

Text truncated - open the document above for the full version.

Test Report

EMC TEST EQUIPMENT ID MLT TBH XFZ DUI IPX TXJ AFN TEST DESCRIPTION ZPH-8-2-SCT/ACNCRNCR PS-400NCR ThermometerOmega Engineering, Inc.HH3112021-02-022024-02-02 CableUtiFlex Micro-CoaxUFD1150A-1-0720-2002002020-09-222021-09-22 NCR DescriptionManufacturerModelLast Cal.Cal. Due Chamber - Temperature/HumidityCincinnati Sub Zero (CSZ) Com-Power 2020-10-15 Testing was performed using the mode(s) of operation and configuration(s) noted within the report. The individuals and/or the organization requesting the test provided the modes, configurations and settings used to complete the evaluation. The actual test parameters are specified in the test data, this includes items such as investigated frequency range (scanned) and test levels. The testing methods and performance specifications, as well as the test site used for the evaluation are indicated in the test data. TransformerStaco Energy Products Co.3PN2520BNCRNCR Meter - MultimeterFluke77-IV2023-10-15 FREQUENCY STABILITY Analyzer - Spectrum AnalyzerKeysightN9010A2021-01-062022-01-06 XMit 2020.12.30.0 Probe - Near Field Set The spectrum analyzer is equipped with a precision frequency reference that exceeds the stability requirement of the EUT. Measurements were made on the single transmit frequency as called out on the data sheets. Testing was done while the EUT was continuously polling. The primary supply voltage was varied from 85 % to 115% of the nominal voltage while at ambient temperature. Using a temperature chamber, the transmit frequency was recorded at the extremes of the specified temperature range of -20 ° to +50° C and at 10°C intervals. The requirement of a frequency tolerance of ±0.01% is equivalent to 100 ppm The formula to check for compliance is: ppm = (Measured Frequency / Measured Nominal Frequency - 1) * 1,000,000 Report No. ABBO0080 Rev 5103/137 XMit 2020.12.30.0 TbtTx 2021.03.19.1XMit 2020.12.30.0 EUT:GLP12408 SAL Alinity C End SectionWork Order:ABBO0080 Serial Number:ENG02-APDate: Customer:Abbott LaboratoriesTemperature:25 °C Attendees:Don MendellHumidity:48.4% RH Project:NoneBarometric Pres.:1019 mbar Tested by:Mark BaytanPower:220VAC/60HzJob Site:TX05 TEST SPECIFICATIONSTest Method COMMENTS DEVIATIONS FROM TEST STANDARD Signature MeasuredAssignedErrorLimit Value (MHz)Value (MHz)(ppm)(ppm)Results Normal Voltage Mid Channel, 13.56 MHz13.5600493313.560049330100Pass Extreme Voltage +15% Mid Channel, 13.56 MHz13.5600326713.560049331.2100Pass Extreme Voltage -15% Mid Channel, 13.56 MHz13.5600336713.560049331.2100Pass Extreme Temperature +50°C Mid Channel, 13.56 MHz13.5599663313.560049336.1100Pass Extreme Te…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Birgit Nowak
[email protected]+49408090510Fax: +4940809051

Test Firm

Element Materials Technology Dallas - PlanoRenee Walker
[email protected]503 844 4066

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from Abbott Automation Solutions GmbH

06R27-21 - FCC ID 2A36T-SGI - Abbott Automation Solutions GmbH
2A36T-SGI

06R27-21

Apr 14, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
06Q09-91 - FCC ID 2A36T-RCP - Abbott Automation Solutions GmbH
2A36T-RCP

06Q09-91

Dec 21, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
06Q11-61 - FCC ID 2A36T-RMR - Abbott Automation Solutions GmbH
2A36T-RMR

06Q11-61

Dec 19, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
06Q01-51 - FCC ID 2A36T-TAC - Abbott Automation Solutions GmbH
2A36T-TAC

06Q01-51

Aug 30, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
06R21-11 - FCC ID 2A36T-GLP9 - Abbott Automation Solutions GmbH
2A36T-GLP9

06R21-11

Oct 05, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter