FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Jenmart Industrial (HK) Co., Limited/
  3. 2A38H-M038CA

2A38H-M038CAHi-fi micro system

Jenmart Industrial (HK) Co., Limited
Hi-fi micro system - FCC ID 2A38H-M038CA - Jenmart Industrial (HK) Co., Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 27, 2025
Application Purpose
Original Equipment
Equipment Note
Hi-fi micro system
Frequency Range
2402.00000000 - 2480.00000000
Company
Jenmart Industrial (HK) Co., Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Hi-fi micro system Model number: M038CA WARNING TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT USE THIS PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADE TERMINALS CAN BE FULLY INSERTED TO PREVENT ANY EXPOSURE. TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. The Caution Marking is located at the bottom enclosure of the product. IMPORTANT SAFETY INSTRUCTIONS 1.Read these instructions carefully. 2.Keep these instructions in a safe place. 3.Heed all warnings. 4.Follow all instructions. 5.Do not use this product near water. 6.Cleaning: Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Clean only with a dry cloth. 7.Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8.Do not place this product on an unstable cart, stand, tripod, bracket, or table. The product may fall, causing serious injury to a child or adult and serious damage to the product. Use only with a cart, stand, tripod, bracket, or table recommended by the manufacturer, or sold with the product. Any mounting of the product should follow the manufacturer’s instructions, and should use a mounting accessory recommended by the manufacturer. A product and cart combination should be moved with care-quick stops, excessive force and uneven surfaces may cause the product and cart combination to overturn. 9.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatuses (including amplifiers) that produce heat. 10.If the provided plug does not fit into your outlet, consult an electrician for replacement of the outlet. 11.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the product. 12.Only use attachments/accessories specified by the manufacturer. 13.Unplug this product during lightening storms or when unused for a long periods of time. 14.Refer all servicing to qualified service personnel. Servicing is required when the product has been damaged in any way, such as the power-supply cord or the plug is damaged, liquid has been spilled or objects have fallen into the product, the product has been exposed to rain or moisture, does not operate normally, or has been dropped. 15.This product shall not be exposed to dripping or splashing water and that no object filled with liquids such as vases shall be placed on the product. 16.Do not overload the wall outlet. Use power source only as indicated. 17.Use replacement part as specified by the manufacturer. 18.Upon completion of any service or repairs to this product, ask the service technician to perform safety checks. 19.Power Sources: This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your product dealer or local power company. For products intended to operate from battery power, or other sources, refer to the operating instructions. 20.Object and Liquid Entry: Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product. 21.This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instructions concerning the use of the product by a person responsible for their safety. 22.Damage Requiring Service: Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: a)When the power-supply cord or plug is damaged, b)If liquid has been spilled, or objects have fallen into the product, c)If the product has been exposed to rain or water, d)If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to its normal operation. e)If the product has been dropped or damaged in any way, and f)When the product exhibits a distinct change in performance - this indicates a need for service. AC Power Adapter • Use only the AC power adapter supplied with the product. • If the housing of the AC power adapter or the connection cable is damaged, the adapter must be disposed of and replaced with a new AC power adapter of the same type. SAVE THESE INSTRUCTIONS CAUTION Follow the advice below for safe operations. ON PROTECTION AGAINST LASER ENERGY EXPOSURE •As the laser beam used in this compact disc player is harmful to the eyes, do not attempt to disassemble the casing. •Stop operation immediately if any liquid or solid object should fall into the cabinet. •Do not touch the lens or poke at it. If you do, you may damage the lens and the player may not operate properly. •Do not put anything in the safety slot. If you do, the laser diode will be ON when the CD door is still open. •If the unit is not to be used for a long period of time, make sure that all power sources are disconnected from the unit. Remove all batteries from the battery compartment. •This unit employs a laser. The use of controls or adjustment or performance of procedures other than those specified here may result in exposure to hazardous radiation. Should any trouble occur, remove the power source and refer servicing to qualified personnel. WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interfe…

Text truncated - open the document above for the full version.

Attestation Statements

Attestation Statements Date: 2025-10-21 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for(FCC ID: 2A38H-M038CA) Jenmart Industrial (HK) Co., Limited , the undersigned, hereby authorize Molo Import Export LLC to act as our designated agent for service of process, Jenmart Industrial (HK) Co., Limited accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Molo Import Export LLC accepts the responsibility to act as designated agent for service of process. Applicant Information: Company name: Jenmart Industrial (HK) Co., Limited Contact Name: Blake Li Address: Units A&B, 15/F, Neich Tower, 128 Gloucester Road, Wanchai, Hong Kong Telephone No: +86-769 28633568 Email: [email protected] FRN: 0031825169 Signature: Blake Li Agent Information: Company Name: Molo Import Export LLC Address: 2334 Crystal Mile CT, Toms River, NJ, 08755, USA FRN: 0033490996 Contact Name: Sam Weiss Telephone No: 514-858-9595 Email: [email protected] Signature: Sam Weiss

Cover Letter(s)

Jenmart Industrial (HK) Co., Limited Declaration Letter of Model Difference Date: 2025-10-21 FCC ID: 2A38H-M038CA Tested Model Number: M038CA Adding Model Number(s): M038CAXX, PRCDT594B All Adding Model Number(s) is/are same electrically identical as Tested Model Number. Only model name and color are different. Yours Sincerely, Applicant: Jenmart Industrial (HK) Co., Limited Address: Units A&B, 15/F, Neich Tower, 128 Gloucester Road, Wanchai, Hong Kong Contact Person: Blake Li Tel.: 86-769-28633568 Email: [email protected] Sincerely, Signature:

Cover Letter(s)

Product specification Quick Reference Date Antenna module on the system board Frequenc Range 2400 ~ 2500MHz Ant. Port Input Pwr. (dBm) 0 (Typ. BT class 2 output power) Tot. Rad. Pwr. (dBm) -1.2 (Input pwr – loss pwr) Peak EIRP(dBm) 1.2 Directivity (dBi) 1 (all direction antenna) Efficiency (dB) 6 0.2 % Gain (dBi) 1.2 (Avg Gain XY-plane) Maximum Power (dBm) 1.7 (XY-plane) Minimum Power (dBm) -4(XY-plane) Avg. Power (dBm) -0.5(XY-plane) Input Impendence(ohm) 50 Polarization Type V ertical & Horizontal V . S .W . R < 1.4 All the technical data and information contained herein are subject to change without prior notice Antenna Layout & module on the system board Antenna Gain Gain Table Unit in dBi @2.44GHz XY-plane XZ-plane YZ-plane Efficiency Peak Avg. Peak Avg. Peak Avg. Module Board 1.2 -0.5 1.9 -3.6 1.1 -3.0 6 0.2 % 1.2 1.9 ( Manufacturer: Rich Glory Electronics Co.,Ltd. Address: No.10Xiling Road, Fengcheng Street, Xinfeng County, Shaoguan City, GuangDong Province, China 5mm 10mm Antenna Type: PCB Antenna Retum Loss The Environment of Antenna Radiation Pattem 3D radiation pattern diagram XY-plane XZ-plane YZ-plane

External Photos

Page 1 of 9 Report No.: LGT25J004 Appendix - External Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 9 Report No.: LGT25J004 Appendix - External Photographs of EUT Constructional Details Photo 3 Photo 4 Page 3 of 9 Report No.: LGT25J004 Appendix - External Photographs of EUT Constructional Details Photo 5 Photo 6 Page 4 of 9 Report No.: LGT25J004 Appendix - External Photographs of EUT Constructional Details Photo 7 Photo 8 Page 5 of 9 Report No.: LGT25J004 Appendix - External Photographs of EUT Constructional Details Photo 9 Photo 10 Page 6 of 9 Report No.: LGT25J004 Appendix - External Photographs of EUT Constructional Details Photo 11 Photo 12 Page 7 of 9 Report No.: LGT25J004 Appendix - External Photographs of EUT Constructional Details Photo 13 Photo 14 Page 8 of 9 Report No.: LGT25J004 Appendix - External Photographs of EUT Constructional Details Photo 15 Photo 16 Page 9 of 9 Report No.: LGT25J004 Appendix - External Photographs of EUT Constructional Details Photo 17

ID Label/Location Info

BRAND M038CA 4. Remote Control Label Cool grey 6C Cool grey 6C White black 2523

Internal Photos

Page 1 of 8 Report No.: LGT25J004 Appendix - Internal Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 8 Report No.: LGT25J004 Appendix - Internal Photographs of EUT Constructional Details Photo 3 Photo 4 ANT Page 3 of 8 Report No.: LGT25J004 Appendix - Internal Photographs of EUT Constructional Details Photo 5 Photo 6 Page 4 of 8 Report No.: LGT25J004 Appendix - Internal Photographs of EUT Constructional Details Photo 7 Photo 8 Page 5 of 8 Report No.: LGT25J004 Appendix - Internal Photographs of EUT Constructional Details Photo 9 Photo 10 Page 6 of 8 Report No.: LGT25J004 Appendix - Internal Photographs of EUT Constructional Details Photo 11 Photo 12 Page 7 of 8 Report No.: LGT25J004 Appendix - Internal Photographs of EUT Constructional Details Photo 13 Photo 14 Page 8 of 8 Report No.: LGT25J004 Appendix - Internal Photographs of EUT Constructional Details Photo 15

RF Exposure Info

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 8 EMF TEST REPORT Product Name: Hi-fi micro system Model Number: M038CA, M038CAXX(Where XX denote any printable characters in the ASClI Standard Character Table to represent variances in cosmetics or buyers), PRCDT594B FCC ID: 2A38H-M038CA Issued For : Jenmart Industrial (HK) Co., Limited Units A&B, 15/F, Neich Tower, 128 Gloucester Road, Wanchai, Hong Kong Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT25J004HA01 Sample Received Date: Oct. 09, 2025 Date of Test: Oct. 09, 2025 ~ Oct. 20, 2025 Date of Issue: Oct. 21, 2025 Report No.: LGT25J004HA01 Page 2 of 8 TEST REPORT CERTIFICATION Applicant: Jenmart Industrial (HK) Co., Limited Address: Units A&B, 15/F, Neich Tower, 128 Gloucester Road, Wanchai, Hong Kong Manufacturer: Rich Glory Electronics Co.,Ltd. Address: No.10Xiling Road, Fengcheng Street, Xinfeng County, Shaoguan City, GuangDong Province, China Factory 1: Rich Glory Electronics Co.,Ltd. Address 1: No.10Xiling Road, Fengcheng Street, Xinfeng County, Shaoguan City, GuangDong Province, China Factory 2: Dongguan City Wangniudun Yinghui Electronics Factory Address 2: Chijiaoluduan Zhenzhong Road,Wangniudun Town,Dongguan City, China Product Name: Hi-fi micro system Trademark: Borne, Brand Model Number: M038CA, M038CAXX(Where XX denote any printable characters in the ASClI Standard Character Table to represent variances in cosmetics or buyers), PRCDT594B Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47 CFR §2.1091 KDB 447498 D01 General RF Exposure Guidance v06 PASS Prepared by: Approved by: Zane Shan Vita Li Engineer Technical Director Report No.: LGT25J004HA01 Page 3 of 8 TABLE OF CONTENTS 1 . GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST LABORATORY 5 2 . FCC 47CFR §2.1091 REQUIREMENT 6 2.1 TEST STANDARDS 6 2.2 LIMIT 6 2.3 EUT OPERATION CONDITION 7 2.4 CLASSIFICATION 7 2.5 TEST RESULT 8 Report No.: LGT25J004HA01 Page 4 of 8 Revision History Rev. Issue Date Revisions 00 Oct. 21, 2025 Initial Issue Report No.: LGT25J004HA01 Page 5 of 8 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name: Hi-fi micro system Test Model Number: M038CA Series Number: M038CAXX(Where XX denote any printable characters in the ASClI Standard Character Table to represent variances in cosmetics or buyers), PRCDT594B Model Difference: M038CAXX compared with the main model, only different colors, PRCDT594B compared with main model only named differently Frequency Bands: Bluetooth 2402-2480MHz Rating: Input: 9V,1.0A AC/DC power adapter. output:2 x 2.5W Battery: 3.0V (1.5V AAA*2) Test voltage: AC 120V/60Hz for adapter Battery: 3.0V Hardware Version: REV:01 Software Version: V06 1.2 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 Report No.: LGT25J004HA01 Page 6 of 8 2. FCC 47CFR §2.1091 REQUIREMENT 2.1 TEST STANDARDS The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 2.2 LIMIT According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of the human exposure to radio-frequency (RF) radiation as specified in 1.1307 (b) Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm²) Limits for Occupational / controlled Exposures 0.3-3.0 614 1.63 *(100) 3.0-30 1842/f 4.89/f *(900/f 2 ) 30-300 61.4 0.163 1.0 300 - 1500 -- -- F/300 1500 – 100000 -- -- 5.0 Limits for General population / Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) 1.34-30 824/f 2.19/f *(180/f 2 ) 30-300 27.5 0.073 0.2 300 - 1500 -- -- F/1500 1500 – 100000 -- -- 1.0 F= Frequency in MHz * = Plane-wave equivalent power density. Friss Formula Friss Transmission Formula: Pd = (Pout * G) / (4*pi*r²) Where Pd = power density in mW/cm² Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = Distance between observation point and the center of radiator in cm If we know the maximum gain of the antenna and the total output power to the antenna, through calculation, we will know MPE value at distance 20cm. Report No.: LGT25J004HA01 Page 7 of 8 2.3 EUT OPERATION CONDITION EUT was enabled to transmit and receive at lowest, middle and highest channels. 2.4 CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. Warning statement to the user for keeping at least 20cm or more separation distance from the antenna should be included in the User manual. So, this device is classified as Mobile device. Report No.:…

Text truncated - open the document above for the full version.

Test Report

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 53 RF TEST REPORT Product Name: Hi-fi micro system Model Number: M038CA, M038CAXX(Where XX denote any printable characters in the ASClI Standard Character Table to represent variances in cosmetics or buyers), PRCDT594B FCC ID: 2A38H-M038CA Issued For : Jenmart Industrial (HK) Co., Limited Units A&B, 15/F, Neich Tower, 128 Gloucester Road, Wanchai, Hong Kong Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT25J004RF02 Sample Received Date: Oct. 09, 2025 Date of Test: Oct. 09, 2025 ~ Oct. 20, 2025 Date of Issue: Oct. 21, 2025 Report No.: LGT25J004RF02 Page 2 of 53 TEST REPORT CERTIFICATION Applicant: Jenmart Industrial (HK) Co., Limited Address: Units A&B, 15/F, Neich Tower, 128 Gloucester Road, Wanchai, Hong Kong Manufacturer: Rich Glory Electronics Co.,Ltd. Address: No.10Xiling Road, Fengcheng Street, Xinfeng County, Shaoguan City, GuangDong Province, China Factory 1: Rich Glory Electronics Co.,Ltd. Address 1: No.10Xiling Road, Fengcheng Street, Xinfeng County, Shaoguan City, GuangDong Province, China Factory 2: Dongguan City Wangniudun Yinghui Electronics Factory Address 2: Chijiaoluduan Zhenzhong Road,Wangniudun Town,Dongguan City, China Product Name: Hi-fi micro system Trademark: Borne, Brand Model Number: M038CA, M038CAXX(Where XX denote any printable characters in the ASClI Standard Character Table to represent variances in cosmetics or buyers), PRCDT594B Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Part 15.247, Subpart C ANSI C63.10-2020 PASS Prepared by: Approved by: Zane Shan Vita Li Engineer Technical Director Report No.: LGT25J004RF02 Page 3 of 53 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST LABORATORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 TEST SOFTWARE AND POWER LEVEL 9 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 10 2.5 EQUIPMENTS LIST 11 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 TEST PROCEDURE 14 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULTS 15 4. RADIATED EMISSION MEASUREMENT 17 4.1 RADIATED EMISSION LIMITS 17 4.2 TEST PROCEDURE 19 4.3 TEST SETUP 19 4.4 EUT OPERATING CONDITIONS 20 4.5 FIELD STRENGTH CALCULATION 20 4.6 TEST RESULTS (BAND EDGE REQUIREMENTS) 25 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 27 5.1 LIMIT 27 5.2 TEST PROCEDURE 27 5.3 TEST SETUP 27 5.4 EUT OPERATION CONDITIONS 27 5.5 TEST RESULTS 27 6. POWER SPECTRAL DENSITY TEST 28 6.1 LIMIT 28 6.2 TEST PROCEDURE 28 6.3 TEST SETUP 28 6.4 EUT OPERATION CONDITIONS 28 Report No.: LGT25J004RF02 Page 4 of 53 6.5 TEST RESULTS 28 7. BANDWIDTH TEST 29 7.1 LIMIT 29 7.2 TEST PROCEDURE 29 7.3 TEST SETUP 29 7.4 EUT OPERATION CONDITIONS 29 7.5 TEST RESULTS 29 8. PEAK OUTPUT POWER TEST 30 8.1 LIMIT 30 8.2 TEST PROCEDURE 30 8.3 TEST SETUP 30 8.4 EUT OPERATION CONDITIONS 30 8.5 TEST RESULTS 30 9. ANTENNA REQUIREMENT 31 9.1 STANDARD REQUIREMENT 31 9.2 EUT ANTENNA 31 APPENDIX I - TEST RESULTS 32 1. DUTY CYCLE 32 2. BANDWIDTH 35 3. MAXIMUM CONDUCTED OUTPUT POWER 40 4. MAXIMUM POWER SPECTRAL DENSITY 43 5. UNWANTED EMISSIONS IN NON-RESTRICTED FREQUENCY BANDS 46 APPENDIX II - MEASUREMENT PHOTOS 53 Report No.: LGT25J004RF02 Page 5 of 53 Revision History Rev. Issue Date Revisions 00 Oct. 21, 2025 Initial Issue Report No.: LGT25J004RF02 Page 6 of 53 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 Part 15.247 Meas Guidance v05r02. FCC Part 15.247, Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted Band Edge Emission PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Report No.: LGT25J004RF02 Page 7 of 53 1.1 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Occupied Channel Bandwidth ±0.46% 2 RF Output Power, Conducted ±0.71dB 3 Power Spectral Density, Conducted ±1.57dB 4 Unwanted Emission, Conducted ±0.63dB 5 Conducted emission ±2.80dB 6 All Emissions, Radiated (0.009-30MHz) ±2.16dB 7 All Emissions, Radiated (30MHz-1GHz) ±4.61dB 8 All Emissions, Radiated (1GHz-18GHz) ±5.49dB 9 Temperature ±0.5°C 10 Humidity ±2% 11 Duty Cycle ±2.3% Note: The measurement uncertainty is not included in the test result. Report No.: LGT25J004RF02 Page 8 of 53 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name: Hi-fi micro system Test Model Number: M038CA Series Number: M038CAXX(Where XX denote any printable characters in the …

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 Report No.: LGT25J004 Appendix - Test Setup photos Set-up for Radiated Spurious Emission, Below 1GHz Set-up for Radiated Spurious Emission, Above 1GHz Page 2 of 2 Report No.: LGT25J004 Set-up for Conducted Emission Set-up for Radio Spectrum

Contact Information

Applicant

Blake Li
[email protected]Fax: +86-769 28633568

Test Firm

Shenzhen LGT Test Service Co., Ltd.Wen Wen
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.71 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Jenmart Industrial (HK) Co., Limited

Personal CD/MP3 Player with FM PLL Radio - FCC ID 2A38HSB3706 - Jenmart Industrial (HK) Co., Limited
2A38HSB3706

Personal CD/MP3 Player with FM PLL Radio

Sep 15, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
PERSONAL BLUTOOTH CD PLAYER WITH FM RADIO - FCC ID 2A38HCD60RBTEB - Jenmart Industrial (HK) Co., Limited
2A38HCD60RBTEB

PERSONAL BLUTOOTH CD PLAYER WITH FM RADIO

Aug 19, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter