FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Finicare Co., Ltd./
  3. 2A3QXFCBP121

2A3QXFCBP121Upper Arm Electronic Blood Pressure Monitor with Bluetooth Low Energy

Shenzhen Finicare Co., Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 21, 2024
Application Purpose
Original Equipment
Date of Application
Jul 16, 2024
Equipment Note
Upper Arm Electronic Blood Pressure Monitor with Bluetooth Low Energy
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Finicare Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 31-05-2024 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2A3QXFCBP121 [Shenzhen Finicare Co., Ltd] certifies that, as of the date of the filing of the application, [CTI U.S. Inc] is our designated U.S. agent for service of process for the above referenced FCC ID. [GD Midea Air- Conditioning Equipment Co., Ltd.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. [CTI U.S. Inc] accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: FRN: 0033406968 Name: CTI U.S. Inc. Address: Suite 230, 1455 CTI U.S. Inc.Lincoln Parkway, Atlanta, GA, 30346Atlanta, Georgia, 30346, UNITED STATES Contact Person: robin.zhang Tel.: 248- 4613673 Email: [email protected] Sincerely, U.S. agent company name CTI U.S. Inc. U.S. agent company name signature Applicant name Shenzhen Finicare Co., Ltd Applicant printed name Chao Li Applicant signature

Attestation Statements

Date: 31-05-2024 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: 2A3QXFCBP121 Dear Sir or Madam, [Shenzhen Finicare Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, [Shenzhen Finicare Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. If you have any questions, please contact us. Sincerely, Company name: Shenzhen Finicare Co., Ltd Company Officer: Chao Li Telephone Number: 86-0755-23013503 Email: [email protected]

Cover Letter(s)

COMPANY LETTERHEAD Date (May 31, 2024) TUV SUD BABT UNLIMITED TCB Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom Confidentiality Request FCC ID: 2A3QXFCBP121 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (Shenzhen Finicare Co., Ltd) hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation] (Shenzhen Finicare Co., Ltd) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (180) days: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Chao Li Telephone Number: 86-0755-23013503 Fax Number: 86-0755-27574425 Email: [email protected]

Cover Letter(s)

Date (May 31, 2023) To: Federal Communications Commission 7435 Oakland Mills Road Columbia MD FCC ID: 2A3QXFCBP121 To Whom It May Concern: This letter is to ascertain that Shenzhen Finicare Co., Ltd Product name: Upper Arm Electronic Blood Pressure Monitor, Model: FC-BP130 has been the units used for conducting FCC compliance testing, the SDoC part will be tested by FCC recognized test lab. If you have any question or concerns, please contact us. Yours sincerely, Company Officer: Chao Li Telephone Number: 86-0755-23013503 Fax Number: 86-0755-27574425 Email: [email protected]

RF Exposure Info

Report Number: 68.930.22.0047.01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 RF exposure Estimation Introduction M/N: FC-BP121 (FCC ID: 2A3QXFCBP121) is a Upper Arm Electronic Blood Pressure Monitor, which supports 2.4GHz Bluetooth functions inside. 1. Limit and Guidelines on Exposure to Electromagnetic Fields According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 General RF Exposure Guidance v06, Mobile Portable RF Exposure, no SAR required if power is lower than the flowing threshold: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation25 • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 2. Calculation method [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 Conducted Power + tune up tolerance = 1.50661mW Distance = 5 mm f = 2.402 GHz [1.50661/5] * SQRT(2.402) =0.467 0.467 ≤ 3.0 Therefore, excluded from SAR testing. TUV SUD China, Shenzhen Branch Reviewed by: Prepared By: Trevor You / EMC Project Manager Ricky Yin / EMC Project Engineer Date: 2024-05-31 Date: 2024-05-31

Test Report

Report Number: 68.930.23.0009.01 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 38 FCC - TEST REPORT Report Number : 68.730.23.0009.01 Date of Issue: 2024-05-09 Model : FC-BP121 Product Type : Upper Arm Electronic Blood Pressure Monitor Applicant : Shenzhen Finicare Co., Ltd Address : 201, No.50, the 3rd Industrial Park, Houting Community, Shajing Street, Bao'an District, Shenzhen 518104 China Manufacturer : Shenzhen Finicare Co., Ltd Address : 201, No.50, the 3rd Industrial Park, Houting Community, Shajing Street, Bao'an District, Shenzhen 518104 China Factory : Shenzhen Finicare Co., Ltd Address : 201, No.50, the 3rd Industrial Park, Houting Community, Shajing Street, Bao'an District, Shenzhen 518104 China Test Result : ◼ Positive  Negative Total pages including Appendices : 38 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 68.930.23.0009.01 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 38 1 Table of Contents 1 Table of Contents .............................................................................................................................. 2 2 Details about the Test Laboratory ..................................................................................................... 3 3 Description of the Equipment Under Test .......................................................................................... 4 4 Summary of Test Standards .............................................................................................................. 5 5 Summary of Test Results .................................................................................................................. 6 6 General Remarks .............................................................................................................................. 7 7 Test Setups ....................................................................................................................................... 8 8 Systems Test Configuration ............................................................................................................ 10 9 Technical Requirement ................................................................................................................... 11 9.1 Conducted Emission ................................................................................................................ 11 9.2 Conducted Peak Output Power ................................................................................................ 14 9.3 Power Spectral Density ............................................................................................................ 17 9.4 6 dB Bandwidth ........................................................................................................................ 19 9.5 Spurious RF Conducted Emissions .......................................................................................... 21 9.6 Band Edge ............................................................................................................................... 26 9.7 Spurious Radiated Emissions for Transmitter .......................................................................... 29 10 Test Equipment List ..................................................................................................................... 36 11 System Measurement Uncertainty ............................................................................................... 38 Report Number: 68.930.23.0009.01 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 38 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District Shenzhen 518052 P.R. China Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 FCC Registration No.: 514049 FCC Designation Number: CN5009 Report Number: 68.930.23.0009.01 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 38 3 Description of the Equipment Under Test Product: Upper Arm Electronic Blood Pressure Monitor Model no.: FC-BP121 FCC ID: 2A3QXFCBP121 Options and accessories: N/A Rating: 6.0VDC (Supplied by 4x1.5V AAA batteries) or 5.0VDC, 1A (Supplied by Medical Adapter) RF Transmission Frequency: 2402MHz-2480MHz No. of Operated Channel: 40 Modulation: GFSK Antenna Type: PCB antenna Antenna 1 Gain: 0.2dBi Description of the EUT: The EUT is an Upper Arm Electronic Blood Pressure Monitor which supports BLE technology. NOTE 1: The above EUT’s information is declared by manufacturer. Please refer to the specifications or user’s manual for more detailed description. NOTE 2: The EUT has been tested under two input volta…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Chao Li
[email protected]0755-23013503Fax: 0755-23574425

Test Firm

TUV SUD Cert & Testing (China) Co., Ltd.Harry Zhou
[email protected]86 755 3332 3281

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.51 mW
Confidentiality
Long Term
Grant Notes
Power listed is peak conducted output power.

Other Applications from Shenzhen Finicare Co., Ltd.

Upper Arm Electronic Blood Pressure Monitor with Bluetooth Low Energy - FCC ID 2A3QXFCBP130 - Shenzhen Finicare Co., Ltd.
2A3QXFCBP130

Upper Arm Electronic Blood Pressure Monitor with Bluetooth Low Energy

Sep 25, 2023

Equipment Class

DTS - Digital Transmission System
Upper Arm Electronic Blood Pressure Monitor - FCC ID 2A3QXFCBP110 - Shenzhen Finicare Co., Ltd.
2A3QXFCBP110

Upper Arm Electronic Blood Pressure Monitor

Jun 08, 2022

Equipment Class

DTS - Digital Transmission System