15301-ML002 REV04 ECN 6055 15301 BETMAKERS SST: KIOSK with BNA ENCLOSURE, WALL MOUNT or PEDESTAL USER SERVICE MANUAL Kiosk with BNA Enclosure Kiosk with Wall Mount Kiosk with Pedestal 15301-ML002 REV04 ECN 6055 Page 2 Version History Dec. 2021 V 0.1 Release Version ISSUE NUMBER DATE ECN COMMENTS APPROVED 01 01-12-2021 5789 INITIAL RELEASE L..DICKSON 02 07-03-2022 5896 ADDITION OF FCC NOTATION. ADDITION OF 400W TO POWER SUPPLY (2.1.3 Electrical). L.DICKSON 03 24-08-2022 6045 UPDATE TO MANUAL DUE TO TIMCO FCC FEEDBACK L.DICKSON 04 29-08-2022 6055 UPDATE TO MANUAL DUE TO TIMCO FCC FEEDBACK. MINOR UPDATE TO CHAPTER 3 & 9 STEP DETAILS & IMAGES. L.DICKSON 15301-ML002 REV04 ECN 6055 Page 3 Who Should Use This Manual This guide is intended for those responsible for the installation and use of the Kiosk. It contains information on: • Installation and set-up instructions • Operational requirements • Kiosk Hardware Component Overview Notices 4 1. Safety Information 4 Danger Notices 5 Caution Notices 6 Electronic Emission & Safety Notices 6 Electrostatic Discharge (ESD) 6 2. Product Description 7 2.1 Physical Specifications ,Operating Environment 7 2.1.1 Mechanical 7 2.1.2 Environmental 7 2.1.3 Electrical 7 2.1.4 Communications 7 2.2 Power Connection / Cable Access 8 3. Replacing the Printer Module 9 4. Replacing the MSR Module 11 5. Replacing the BNA Cash Box Module (BNA Enclosure) 13 6. Replacing the BNA Cash Box Module (Wall Mount) 15 7. Replacing the BNA Cash Box Module (Pedestal) 17 8. Removing the BNA Bill Validation Module 18 9. Replacing the Power Supply 19 10. Replacing the Proximity Sensor 22 11. Replacing the NFC Reader 23 12. Replacing the LCD Screen 24 Contents 15301-ML002 REV04 ECN 6055 Page 4 Notices Note: For any safety-related incident that occurs related to this machine, the field personnel involved must immediately follow regular Safety Incident Reporting and contact the following department: Neo Products Pty Ltd. 62-66 Pacific Drive Keysborough, VIC 3173 Phone (03) 9701 1511 The System Services Representative (SSR) should check the following: 1. Ensure that the Kiosk is plugged into a properly grounded outlet. 2. Ensure that the ground wires are properly secured at each end and not pinched. Neo Products believes the information provided below is accurate, but except the extent required by law, makes no commitment, affirmation, or certification with respect to any of the information. Rather, Neo Products provides all such information “AS IS”, without any express or implied warranty of any kind. Neo Products reserves the right to make improvements and/or changes in the product and/or programme described in this publication without advance notice if Neo Products believes it is appropriate to do so. Changes will be incorporated in new editions of the publication and replaces all previous releases. Neo Products may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Any references in this information to non-Neo Products Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this product and use of those Web sites is at your own risk. SAVE THESE INSTRUCTIONS Read the following information before operating the equipment. Definitions of Hazard Levels: The word DANGER indicates the presence of a hazard that has the potential of causing death or serious personal injury. The word CAUTION indicates the presence of a hazard that has the potential of causing moderate or minor personal injury. Chapter 1 - Safety Information – READ THIS FIRST 15301-ML002 REV04 ECN 6055 Page 5 Danger Notices DANGER: To prevent a possible shock from touching two surfaces with different protective ground (earth), use one hand, when possible, to connect or disconnect signal cables. DANGER: Overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions. To avoid these hazards, ensure that your system electrical requirements do not exceed branch circuit protection requirements. Refer to the information that is provided with your device or the power rating label for electrical specifications. DANGER: An electrical outlet that is not correctly wired could place hazardous voltage on the metal parts of the system or the devices that attach to the system. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock. DANGER: When working on or around the system, observe the following precautions: Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: • If Neo Products supplied a power cord, connect power to this unit only with the Neo Products provided power cord. Do not use the Neo Products provided power cord for any other product. • Do not open or service any power supply assembly. • Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. • The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. • Connect all power cords to a properly wired and grounded electrical outlet. Ensure that the outlet supplies proper voltage and phase rotation according to the system rating plate. • Connect any equipment that will be attached to this product to properly wired outlets. • When possible, use one hand only to connect or disconnect signal cables. • Never turn ON any equipment when there is evidence of fire, water, or structural damage. • Sharp edges, corners and joints may be present in and around the system. Use care when handling equipment to avoid cuts, scrapes and pinching. • Route all cords away from sharp edges, corners and points, moving parts and heated surfaces, to prevent damage to the cable insulation. Never ro…
Text truncated - open the document above for the full version.
Rev 11/20/07 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: (2A3TL-15301). Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematics Block Diagrams Operational description (theory of operation) 15301 Schem1-3 15301 BlkDia 15301-OpDes The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below for 180 days: Exhibit Type File Name External photos Test set-up photos Internal photos User Manual 15301 ExtPho5,6,9,10 15301 Tsup_Rev3 15301 IntPho & 15301 IntPho1-6 & 15301 IntPho PCB1-6 15301 UserMan1-5 Sincerely, Mike Mitchell CHIEF OPERATING OFFICER
Label location (LH Side of device)
NeoProducts Pty Ltd ACN 007 152 374 ABN 76 007 152 374, 62-66 Pacific Drive, Keysborough, Vic, 3173 Telephone 03 9701 1511 www.neoproductsgroup.com Page 1 of 1 15301 – Betline SST NeoProducts - RF Exposure FCC ID#: 2A3TL-15301
The results detailed in this test report relate only to the specific sample/s tested. It is the Manufacturer’s responsibility to ensure that all production units are manufactured with equivalent EMC characteristics. This report is not to be reproduced except in full, without written approval from Compliance Engineering Pty Ltd. NEO Products PTY LTD Betline SST Model No: 15301-GA0X EMC Compliance Test Report CFR 47, Chapter 1, Subpart A, Part 15, Subpart B (class A limits) Report Number: CE3338Rev1 August 2022 90 Indian Drive Keysborough VIC 3173 Australia Telephone: + 61 3 9763 3079 Email: [email protected] Web: www.compeng.com.au ABN: 56 101 639 588 Compliance Engineering Test Report CE3338Rev1, August 2022 Page 2 of 18 This test report is not to be reproduced except in full, without written approval from Compliance Engi neering Pty Ltd. 90 Indian Drive, Keysborough, Victoria 3173. Australia Telephone: +61 3 9763 3079 Email: [email protected] Web: www.compeng.com.au COMPLIANCE CERTIFICATE Client Contact: NEO Products PTY LTD Mike Mitchell Telephone: 97011511 Email: [email protected] Device: Betline SST Model No: 15301-GA0X) FCC ID No: 2A3TL-15301 Reference Standard: CFR 47 - Telecommunication Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart B Unintentional Radiators Test Method: ANSI C63.4-2014: American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the range of 9 kHz to 40 GHz. Summary Result: Radiated RF emission measurements (Class A) Complied Mains Terminal RF emissions (Class A) Complied Test Date: 3 rd and 4 th March 2022 Tests Performed by: Mohamed Elmi Compliance Engineering Pty Ltd 90 Indian Drive, Keysborough Victoria, Australia 3173 Telephone: +61 3 9763 3079 Email: [email protected] The Betline SST (Model No: 15301-GA0X) Complies with radiated and conducted RF emission requirements detailed in CFR 47, Chapter 1, Subpart A, Part 15, Subpart B (class A limits). 26 th August 2022 Prepared By: Mohamed Elmi Test Engineer Compliance Engineering Pty Ltd Approved By: Andrew Burden Technical Manager Compliance Engineering Pty Ltd Date Compliance Engineering Test Report CE3338Rev1, August 2022 Page 3 of 18 This test report is not to be reproduced except in full, without written approval from Compliance Engi neering Pty Ltd. 90 Indian Drive, Keysborough, Victoria 3173. Australia Telephone: +61 3 9763 3079 Email: [email protected] Web: www.compeng.com.au Revision History Revision Issue Date Remarks Revised by 1 04-03-2022 Initial release 2 26-08-2022 FCC ID included GM Compliance Engineering Test Report CE3338Rev1, August 2022 Page 4 of 18 This test report is not to be reproduced except in full, without written approval from Compliance Engi neering Pty Ltd. 90 Indian Drive, Keysborough, Victoria 3173. Australia Telephone: +61 3 9763 3079 Email: [email protected] Web: www.compeng.com.au EMC Compliance Test Report 1. INTRODUCTION Electromagnetic compatibility (EMC) measurements were performed on the Betline SST (Model No: 15301-GA0X) in accordance with the requirements detailed in CFR 47, Chapter 1, Subpart A, Part 15, Subpart B (Class A limits). 2. RESULTS SUMMARY CFR 47, Chapter 1, Subpart A, Part 15, Subpart B FCC Rule Description Class Result Remark 15.107 AC conducted emissions A Pass 1.4 dB under Class A limit @ 13.5 MHz 15.109 Radiated emissions A Pass 4.8 dB under Class A limit @ 30.2 MHz 3. TEST SAMPLE Equipment Under Test (Information supplied by client): Product Name Betline SST Model Number: 15301-GA0X where x is any number. Brand Name(s) - Serial Number: 15301-GA002-00 Hardware Version: - NFC FCC ID No: PD9AX201D2 Wifi FCC ID No: 2AJYU-8PYA007 4G Modem FCC ID No: V5MACR1252 Software/Firmware Version: - Equipment type: The equipment is used in sports venues and racecourses and comprises of touch screen, thermal printer, a document imager, a note accepter, barcode scanner, NFC, magstripe reader, low power PC, WIFI and a 4G modem. Main test frequencies: F LOW 30 MHz F HIGH 13 GHz Power Supply V NOM : V MIN : V MAX : 115 VAC, 60 Hz Compliance Engineering Test Report CE3338Rev1, August 2022 Page 5 of 18 This test report is not to be reproduced except in full, without written approval from Compliance Engi neering Pty Ltd. 90 Indian Drive, Keysborough, Victoria 3173. Australia Telephone: +61 3 9763 3079 Email: [email protected] Web: www.compeng.com.au 4. CONFIGURATION Measurements were performed on the Betline SST (Model No: 15301-GA0X) while powered from 115VAC, 60Hz To exercises the sample to its fully operational mode two different software installed into the equipment was run during the test: SporTech Diagnostic software: This software serves to exercise the Betslip mark scanner peripheral by simulating a slip load, slip read, and slip eject. BurninTest software: The BurnIn test simulates a betting operation and exercises the Printer peripheral continuously. Ethernet port was exercised during the measurements by playing a YouTube video stream to make sure it is connected to the network. 5. MODIFICATIONS No modifications were performed on the above sample by Compliance Engineering Pty Ltd. 6. STANDARD DEVIATIONS No deviation from the standard were performed by Compliance Engineering Pty Ltd. 7. TEST FACILITY All measurements were performed inside Compliance Engineering’s, 3m Semi-Anechoic (iOATS) and/or shielded enclosures located at 90 Indian Drive, Keysborough, Victoria, Australia. A2LA (ISO 17025-2017) – Certificate No: 2829.01 Compliance Engineering Pty Ltd, is accredited to ISO 17025-2017 by American Association for Laboratory Accreditation (A2LA) which is an ILAC member and has mutual recognition agreements with the National Voluntary Laboratory Accreditation Program (NVLAP) All tests within this report have been conducted in accordance with Compliance Engineering’s scope of A2LA accreditation. The current…
Text truncated - open the document above for the full version.
Betline SST - test set-up photos: Betline SST - test set-up photos: Betline SST - test set-up photos:
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Betline TOT
Equipment Class
JAD - Part 15 Class A Digital Device
Betline TSST The equipment is used in sports venues and racecourses and comprises of 2 touch screens, thermal printer, a document imager, a note accepter, barcode scanner, NFC, magstripe eader, low power PC, WIFI and a 4G modem
Equipment Class
JAD - Part 15 Class A Digital Device