FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. HONGKONG ZHINYU TECHNOLOGY CO., LIMITED/
  3. 2A598-F168

2A598-F168Fitness Tracker

HONGKONG ZHINYU TECHNOLOGY CO., LIMITED
Fitness Tracker - FCC ID 2A598-F168 - HONGKONG ZHINYU TECHNOLOGY CO., LIMITED
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 07, 2023
Application Purpose
Original Equipment
Date of Application
Nov 07, 2023
Equipment Note
Fitness Tracker
Frequency Range
2402.00000000 - 2480.00000000
Company
HONGKONG ZHINYU TECHNOLOGY CO., LIMITED
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

 Heart rate and Blood Oxygen sensor Charging USB port Home Screen Heart Rate Mode Today’s Data Important Safety Instructions The device contains electrical equipment that may cause injury if not used properly. For example, prolonged contact may contribute to skin allergies for some users. To reduce irritation, please read the safety guidelines on the following pages to ensure proper use and care. s Do not expose your device to liquid, moisture, humidity or rain while charging; do not charge your device when it is wet, as this may result in electrical shock and injury. s Consult your doctor before use if you have any preexisting conditions that might be affected by using this device. s Do not expose your device to extremely high or low temperatures. s Do not leave your device near open flames such as cooking stoves, candles, or fireplaces. s This product is NOT a toy - never allow children or pets to play with this product. Always store the product out of the reach of children. The devices themselves or the many small parts they contain may cause choking if ingested. s Never try to abuse, crush, open, repair or disassemble this device. Doing so will void the warranty and can result in a safety hazard. s If any parts of your product require replacement for any reason, including normal wear and tear or breakage, please contact us. s Do not use your device in a sauna or steam room. s Dispose of this device, the device’s battery and its package in accordance with local regulations. s Do not check any notifications, GPS, or any information on your device’s display while driving or in other situations where distractions could cause injury or hazard. Always be aware of your surroundings while exercising. Battery Warnings A lithium-ion battery is used in this device. If these guidelines are not followed, batteries may experience a shortened life span or may cause fire, chemical burn, electrolyte leakage, and/or injury. s Do NOT disassemble, modify, remanufacture, puncture or damage the device or batteries. s Do NOT remove or attempt to remove the non-user-replaceable battery. s Do NOT expose the device or batteries to fire, explosion, or other hazards. Health Warningss If you have a pacemaker or other internal electronic device, consult your physician before using a heart rate monitor. s The optical wrist heart rate monitor emits green light and flashes occasionally. Consult your physician if you have epilepsy or are sensitive to flashing lights. s Always consult your physician before beginning or modifying any exercise program. NOTE: This equipment has been tested and found to comply with the limits for Class B digital devices, in accordance with section 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:s2EORIENTORRELOCATETHERECEIVINGANTENNAs)NCREASETHESEPARATIONBETWEENTHEEQUIPMENTANDRECEIVERs#ONNECTTHEEQUIPMENTINTOANOUTLETONACIRCUITDIFFERENTF ROMTHATTOWHICHTHE receiver is connected. s#ONSULTTHEDEALERORANEXPERIENCEDRADIO46TECHNICIANFOR HELP Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and(2) this device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. FCC ID 2A598-F168 s The device, accessories, heart rate monitor, blood oxygen level measurement and related data are intended to be used only for recreational purposes and not for medical purposes and are not intended to diagnose, monitor, treat, cure, or prevent any disease or condition. s The heart rate and blood oxygen level readings are for reference only, and no responsibility is accepted for the consequences of any erroneous readings. s While the optical wrist heart rate monitor technology typically provides the best estimate of a user's heart rate, there are inherent limitations with the technology that may cause some of the heart rate readings to be inaccurate under certain circumstances, including the user's physical characteristics, fit of the device, and type and intensity of activity. s The device relies on sensors that track your movements and other metrics. The data and information provided by these devices are intended to be a close estimation of your activity and metrics tracked, but may not be completely accurate, including step, sleep, distance, heart rate, blood oxygen and calorie data. Some people with allergic skin may react when their skin is exp osed to materials used in watches for a long time. This may be cause d by allergies, environmental factors, prolonged exposure to irritan ts such as sweat and soap, or other factors. If you have known skin all ergies, please pay special attention when wearing the tracker. Please do not wear your tracker too tight.If your tracker gets wet (for example after sweating or showering), clean and dry it thoroughly before putting it back on your wrist.Make sure your skin is dry before you put your tracker back on.Prolonged…

Text truncated - open the document above for the full version.

Attestation Statements

C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: HONGKONG ZHINYU TECHNOLOGY CO., LIMITED FRN: 0032222242 Grantee code: 2A598 FCC ID: 2A598-F168 Contact Name: Jun Wang Address: FLAT/RM A 12/F ZJ 300, 300 LOCKHART ROAD, WAN CHAI, HONG KONG Telephone No: 17722458903 Fax No: Email: [email protected] i. [HONGKONG ZHINYU TECHNOLOGY CO., LIMITED] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [ HONGKONG ZHINYU TECHNOLOGY CO., LIMITED] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. HONGKONG ZHINYU TECHNOLOGY CO., LIMITED certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Date: 11.03.2023 Applicant’s Name: Jun Wang Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: HONGKONG ZHINYU TECHNOLOGY CO., LIMITED Address: FLAT/RM A 12/F ZJ 300, 300 LOCKHART ROAD, WAN CHAI, HONG KONG Product Name: Fitness Tracker Model Number: F168 FCC Identifier: 2A598-F168 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Jun Wang Date: 11/3/2023 Title: Manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.1 1/1 HONGKONG ZHINYU TECHNOLOGY CO., LIMITED Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 11/3/2023 Subject: Request for Confidentiality FCC ID: 2A598-F168 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Jun Wang Date: 11/3/2023 Title: Manager

External Photos

Page 1 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Photographs of the EUT (External Photos) Model: F168 Page 2 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 3 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 4 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected]

ID Label/Location Info

Label Model: F168 FCC ID: 2A598-F168 Location

Internal Photos

Page 1 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Photographs of the EUT (Internal Photos) Model: F168 Page 2 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 3 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 4 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] ANT Page 5 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 6 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected]

RF Exposure Info

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] RF EXPOSURE Test Report Report No.: MTi230822006-12E2 Date of issue: 2023-10-18 Applicant: HONGKONG ZHINYU TECHNOLOGY CO., LIMITED Product: Fitness Tracker Model(s): F168 FCC ID: 2A598-F168 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 6- Report No.: MTi230822006-12E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Instructions 1. The report shall not be partially reproduced without the written consent of the laboratory; 2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report. - Page 3 of 6- Report No.: MTi230822006-12E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Applicant: HONGKONG ZHINYU TECHNOLOGY CO., LIMITED Address: FLAT/RM A 12/F ZJ 300, 300 LOCKHART ROAD, WAN CHAI, HONG KONG Manufacturer: HONGKONG ZHINYU TECHNOLOGY CO., LIMITED Address: FLAT/RM A 12/F ZJ 300, 300 LOCKHART ROAD, WAN CHAI, HONG KONG Product description Product name: Fitness Tracker Trademark: Runlio, Enfit, LETSACTIV, Kummel, Stiive, LIVIKEY Model name: F168 Serial Model: N/A Standards: N/A Test method: KDB 447498 D01 v06 Date of Test Date of test: 2023-10-12 to 2023-10-18 Test result: Pass Test Engineer : (Maleah Deng) Reviewed By: : (Leon Chen) Approved By: : (Tom Xue) - Page 4 of 6- Report No.: MTi230822006-12E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Table of Contents 1. STANDALONE SAR TEST EXCLUSION CONSIDERATIONS ............................................................................................ 5 2. SAR TEST EXCLUCSION THRESHOLDS ........................................................................................................................ 6 - Page 5 of 6- Report No.: MTi230822006-12E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test separation distance defined in 4.1 f) is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander. To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified, typically in the SAR measurement or SAR analysis report, by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting are required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions. a) For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where  f (GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation  The result is rounded to one decimal place for comparison  The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. b) For 100 MHz to 6 GHz and test separation distances > 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following (also illustrated in Appendix B): 1) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)·(f(MHz)/150)]} mW, for 100 MHz to 1500 MHz 2) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)·10]} mW, for > 1500 MHz and ≤ 6 GHz …

Text truncated - open the document above for the full version.

Test Report

Antennatestreport 1.Antennasize Manufacturer:ShenzhenXingkedawireandcableCo.,LTD 2.Testsystem Thetestsystemisageneralstandardtestdarkroomsystem。Thetestbandsinclude800MHz-6GHz frequencies 。 Darkroomappearancedimensions6m*3m*3m 。 Darkroominteriorpicture : Tesenvironment Testtheschematicdiagram 3.Testdata Efficiencyandgain PassiveTestForWIFI2.4 FreqEffiEffiGainGainUHISDHISMaxMin Direct ivity Beamw idth AttHAttV (MHz)(%)(dB)(dBi)(dBd)(%)(%)(dB)(dB)(dBi)(3dB)(dB)(dB) 24005.04-12.98-9.18-11.332.6052.432-9.18-30.873.86049.7149.78 24104.12-13.85-10.25-12.42.1082.014-10.25-29.463.66049.1249.26 24203.22-14.92-11.24-13.391.6481.57-11.24-31.333.686049.0149.03 24304.53-13.44-9.93-12.082.2642.268-9.93-31.823.56049.4249.5 24403.66-14.37-10.61-12.761.8231.833-10.61-32.23.766049.9449.86 24505.32-12.74-8.94-11.092.6492.673-8.94-30.573.87549.4649.52 24603.43-14.65-10.7-12.851.7091.717-10.7-31.123.957549.3249.29 24704.34-13.62-9.8-11.952.1612.181-9.8-30.373.827549.4849.35 24803.34-14.76-10.9-13.051.6461.693-10.9-30.483.867550.1250 24904.61-13.36-9.25-11.42.2762.336-9.25-28.784.117549.449.15 25003.83-14.17-10.42-12.571.8521.975-10.42-29.483.757549.1649.04

Test Report

The test report is only used for customer scientific research, teaching, internal quality control and other purposes, and is for internal reference only. Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Report Report No.: MTi230822006-12E1 Date of issue: 2023-10-18 Applicant: HONGKONG ZHINYU TECHNOLOGY CO., LIMITED Product: Fitness Tracker Model(s): F168 FCC ID: 2A598-F168 Shenzhen Microtest Co., Ltd. http://www.mtitest.com Page 2 of 48 Report No.: MTi230822006-12E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Page 3 of 48 Report No.: MTi230822006-12E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Table of contents 1 General Description ......................................................................................................................... 5 1.1 Description of the EUT ............................................................................................................................... 5 1.2 Description of test modes .......................................................................................................................... 5 1.3 Environmental Conditions .......................................................................................................................... 7 1.4 Description of support units ....................................................................................................................... 7 1.5 Measurement uncertainty .......................................................................................................................... 7 2 Summary of Test Result .................................................................................................................. 8 3 Test Facilities and accreditations ................................................................................................... 9 3.1 Test laboratory ........................................................................................................................................... 9 4 List of test equipment .................................................................................................................... 10 5 Evaluation Results (Evaluation) .................................................................................................... 11 5.1 Antenna requirement ............................................................................................................................... 11 6 Radio Spectrum Matter Test Results (RF) .................................................................................... 12 6.1 Conducted Emission at AC power line .................................................................................................... 12 6.2 Occupied Bandwidth ................................................................................................................................ 15 6.3 Maximum Conducted Output Power ........................................................................................................ 16 6.4 Power Spectral Density ........................................................................................................................... 17 6.5 RF conducted spurious emissions and band edge measurement .......................................................... 18 6.6 Band edge emissions (Radiated) ............................................................................................................ 19 6.7 Radiated emissions (below 1GHz) .......................................................................................................... 24 6.8 Radiated emissions (above 1GHz) .......................................................................................................... 28 Photographs of the test setup ............................................................................................................. 35 Photographs of the EUT....................................................................................................................... 36 Appendix A: DTS Bandwidth ............................................................................................................... 37 Appendix B: Maximum conducted output power ............................................................................... 39 Appendix C: Maximum power spectral density .................................................................................. 41 Appendix D: Band edge measurements ............................................................................................. 43 Appendix E: Conducted Spurious Emission ...................................................................................... 44 Appendix F: Duty Cycle ....................................................................................................................... 47 Page 4 of 48 Report No.: MTi230822006-12E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe C…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Photographs of the test setup Model: F168 Radiated emissions (below 1GHz) Radiated emissions (above 1GHz) Page 2 of 2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Conducted Emission at AC power line

Contact Information

Applicant

Jun Wang(Manager)
[email protected]17722458903Fax: N/A

Technical Contact

Shenzhen Microtest Co., LtdLeon Chen
[email protected]86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Phoebe Cui
[email protected]0755 88850135 1393

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.10 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from HONGKONG ZHINYU TECHNOLOGY CO., LIMITED

Wireless TV Headphones - FCC ID 2A598-TH15 - HONGKONG ZHINYU TECHNOLOGY CO., LIMITED
2A598-TH15

Wireless TV Headphones

Apr 16, 2024

Equipment Class

DTS - Digital Transmission System