2A5UQ-SCDUAccess Control System

Armatura LLC
Access Control System - FCC ID 2A5UQ-SCDU - Armatura LLC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 03, 2023
Application Purpose
Original Equipment
Date of Application
Apr 03, 2023
Equipment Note
Access Control System
Frequency Range
2422.00000000 - 2452.00000000
Company
Armatura LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

8VHU 0DQXDO $UPDWXUD +RUL]RQ &RQWUROOHU ,3%DVHG %LRPHWULF 'RRU 8QLW $SSOLFDEOH 0RGHOV $+6& $+'86HULHV $+(% 6HULHV 'DWH )HEUXDU\  9HUVLRQ  $UPDWXUD +RUL]RQ &RQWUROOHU8VHU 0DQXDO &RS\ULJKW ‹  $50$785$ //& $OO ULJKWV UHVHUYHG 3DJH_, &RS\ULJKW ‹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‹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‹  $50$785$ //& $OO ULJKWV UHVHUYHG 3DJH_,,, 7DEOH RI &RQWHQWV  6DIHW\ ,QVWUXFWLRQV  ,PSRUWDQW 6HFXULW\ ,QVWUXFWLRQV...................................................................................................................... 1  ,QVWDOODWLRQ ,QVWUXFWLRQV.......................................................................................................................................2  2YHUYLHZ  ,QWURGXFWLRQ...............................................................................................................................................................4  )HDWXUHV...................…

Text truncated - open the document above for the full version.

Attestation Statements

Applicant Declaration QSF27-14-04 Rev 1.0 Rev. Feb 6, 2023Page 1 of 1 Original Issue: Jan. 4, 2021 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Armatura LLC Address 190 Bluegrass Valley Parkway Alpharetta Georgia 30005 United States Grantee Code 2A5UQ FCC ID 2A5UQ-SCDU Authorized Contact Name Simon Zhang Contact Email [email protected] Contact Phone 470-816-1970 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO 17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicantshallmake provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicantshall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs:https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs:https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100:https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Link to the Covered List:Covered List [Armatura LLC] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [Armatura LLC] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered list, established pursuant to §1.50002, as an entity producing “covered” equipment. Applicant Signature: Date:2023-02-14 Print Name: Simon Zhang Title: Product Manager *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

Attestation Statements

Armatur aLLC 2.911 (d)(7)USAAgentv1.2 Section2.911(d)(7)USAAgentforServiceofPr ocess Companyname:ArmaturaLLC Address:190BluegrassValleyParkwayAlpharettaGeorgia30005UnitedStates ProductName:AccessControlSystem FCCID:2A5UQ-SCDU 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[Armatura LLC](“ the applicant”) designate[Armatura LLC] NOTE1 for thepurposeofaccepting serviceofprocesson behalfof the applicant. Applicantconsent:WeAcknowledgeourconsenttoacc eptserviceofprocessintheUnited Statesformattersrelatedtotheapplicableequipment,andatthephysicalU.S.addressand emailaddressofthedesignatedagentandacknowledgeouracceptanceofourobligationto maintainanage ntforserviceofprocessintheUnitedStatesfornolessthanoneyearafter eitherthegranteehaspermanentlyterminatedallmarketingandimportationoftheapplicable equipmentwithintheU.S.,ortheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. Agentobligation:WeAcknowledgeourobligationtoacceptserviceofprocessintheUnited StatesformattersrelatedtotheapplicableequipmentatourphysicalU.S.addressandemail addressforn olessthanoneyearaftereitherthegranteehaspermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofany Commission-relatedadministrativeorjudicialproc eedinginvolvingtheequipment,whichever islater. USAAgent Companyname:ArmaturaLLC Address:190Bluegras sValleyParkway AlpharettaGeorgia30005UnitedStates FRN: 0032138596 ContactName:Simon Zhang TelephoneNo:470-816-1970 Email: [email protected] Applicant Companyname:ArmaturaLLC Address:190BluegrassValleyParkway Alp harettaGeorgia30005UnitedStates FCCID:2A5UQ-SCDU ContactName:SimonZhang TelephoneNo:470-816-1970 Email:[email protected] Signature: Title:ProductManager Signature: Title:ProductManager Date:2023-02-14Date:2023-02-14 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. ArmaturaLLC 2.911(d)(7)USAAgentv1.2 Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Cover Letter(s)

ArmaturaLLC Date:2023/01/03 TO:FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 Regarding:FCCID:2A5UQ-SCDU Towhomitmayconcern: We,theundersigned,herebyauthorizeComplianceCertificationServices(Kunshan)Inctoactonour behalfinallmannersrelatingtoapplicationforequipmentauthorizationwithrespecttotheFCCIDabove, includingsigningofalldocumentsrelatingtothesematters.Anyandallactscarriedoutbytheagenton ourbehalfshallhavethesameeffectasactsofourown. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits,thatincludes FCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21U.S.C.853(a). Whereouragentsignstheapplicationforcertificationonourbehalf,Iacknowledgethatallresponsibility forcomplyingwiththetermsandconditionsforCertification,asspecifiedbySGSNorthAmerica,Inc.,still resideswithArmaturaLLC. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. PrintName:SimonZhangTitle:ProductManager Signature: OnbehalfofCompany:ArmaturaLLC Telephone:470-816-1970 E-mail:[email protected]

Cover Letter(s)

ArmaturaLLC TO:FederalCommunicationCommission Equipmen tAuthorizationBr anch 7435OaklandMillsRoad Columbia,MID21046 Regarding:ConfidentialityRequestregardingapplicationforFCCID:2A5UQ-SCDU LO NGTERMCONFIDENTIALITY Pursuant to47CFRSection0.459and0.457ofthecommission’sru les,theapplicantherebyrequest con fidenti altreatmentofthedocumentslistedbelow,associatedwiththecertificationapplication referencedabove. Schematic(s) Block Diagrams OperationalDescriptions Software security description Thedocumentsabovecontainproprietaryinformationnotreleasedtothepublic.Publicdisclosureofthis informationmayproveharmfultothebusinessoftheapplicant. SHORTTERMCONFIDENTIALITY Additional ly,theapplican trequeststhefollowingdocumentsbeheldconfidentialuntilthedeviceis marketedor180daysfromthegrantdate,whi cheverisless.Ifthedeviceismarketedwithinconfidential period,th eapplicantwillnotifytheTCBperFCCKDB726920D01ConfidentialityRequestProcedures. ExternalPhotos InternalPhotos Test SetupPhotos Usermanual(s) Sincerely, PrintName:SimonZhangTitle:ProductManager Signature: OnbehalfofCompany:ArmaturaLLC Telephone:470-816-1970 E-mail:[email protected]

External Photos

Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A02 Rev.A/0 Page: 1 of 6 Appendix External Photos for FYCR2212000525AT FCC ID: 2A5UQ-SCDU Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A02 Rev.A/0 Page: 2 of 6 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A02 Rev.A/0 Page: 3 of 6 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A02 Rev.A/0 Page: 4 of 6 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A02 Rev.A/0 Page: 5 of 6 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A02 Rev.A/0 Page: 6 of 6

ID Label/Location Info

Location

Internal Photos

Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 1 of 11 Appendix Internal Photos for FYCR2212000525AT FCC ID: 2A5UQ-SCDU Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 2 of 11 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 3 of 11 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 4 of 11 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 5 of 11 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 6 of 11 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 7 of 11 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 8 of 11 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 9 of 11 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 10 of 11 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 11 of 11 - End of the Appendix -

RF Exposure Info

Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221200052505 Page: 1 of 15 Winkey Wang EMC Technical Manager RF EXPOSURE EVALUATION REPORT Application No.: FYCR2212000525AT Applicant: Armatura LLC Address of Applicant: 190 Bluegrass Valley Parkway Alpharetta, GA 30005, USA Manufacturer: Armatura LLC Address of Manufacturer: 190 Bluegrass Valley Parkway Alpharetta, GA 30005, USA Factory: Armatura Tech Co., Ltd Address of Factory: 999/120-121 Moo 15 Bangsaothong, Samutprakarn 10570, Thailand Equipment Under Test (EUT): EUT Name: Access Control System Model No.: AHSC-1000, AHDU-1160, AHDU-1260, AHDU-1460   Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. Trade Mark: FCC ID: 2A5UQ-SCDU Standard(s) : FCC Rules 47 CFR §2.1091 KDB 447498 D04 interim General RF Exposure Guidance v01 Date of Receipt: 2022-12-27 Date of Evaluation: 2023-01-09 to 2023-02-27 Date of Issue: 2023-03-02 Evaluation Result: Pass* * In the configuration evaluated, the EUT complied with the standards specified above. Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221200052505 Page: 2 of 15 Revision Record Version Chapter Date Modifier Remark 01 2023-03-02 Original Authorized for issue by: Tree Zhan/Project Engineer Winkey Wang/Reviewer Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221200052505 Page: 3 of 15 2 Contents Page 1 Cover Page ......................................................................................................................................... 1 2 Contents ............................................................................................................................................. 3 3 General Information............................................................................................................................ 4 3.1 General Description of E.U.T. ....................................................................................................... 4 3.2 Details of E.U.T. ........................................................................................................................... 4 3.3 Separation Distance ..................................................................................................................... 6 3.4 Test Location ............................................................................................................................... 7 3.5 Test Facility .................................................................................................................................. 7 3.6 Deviation from Standards ............................................................................................................. 7 3.7 Abnormalities from Standard Conditions ....................................................................................... 7 4 FCC Radiofrequency radiation exposure limits ................................................................................ 8 4.1 Blanket 1 mW Blanket Exemption ................................................................................................. 8 4.2 MPE-based Exemption ................................................................................................................. 8 4.3 SAR-based Exemption ................................................................................................................. 9 5 Measurement and Calculation ..........................................................................................................12 5.1 Maximum transmit power ............................................................................................................12 5.2 RF Exposure Calculation .............................................................................................................14 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221200052505 Page: 4 of 15 3 General Information 3.1 General Description of E.U.T. Product Type: Portable device Mobile device Fixed device 3.2 Details of E.U.T. Power Supply: Powered by PoE or internal switching power Internal switching power information: Input: 100-240V AC 50/60 Hz Output: DC 12V For BLE: Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: V5.2 LE Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: Dipole Antenna Antenna Gain: 4.25dBi For 2.4G Wi-Fi: Operation Frequency: 802.11b/g/n(HT20): 2412MHz to 2462MHz 802.11n(HT40): 2422MHz to 2452MHz Modulation Type: 802.11b: DSSS (CCK, DQPSK, DBPSK) 802.11g/n: OFDM (64QAM, 16QAM, QPSK, BPSK) Number of Channels: 802.11b/g/n(HT20):11;802.11n(HT40):7 Channel Spacing: 5MHz Antenna Type: Dipole Antenna Antenna Gain: Antenna1&2: 4.25dBi Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221200052505 Page: 5 of 15 For 5G Wi-Fi: Operation Frequency (20MHz): U-NII-1: 5180MHz-5240MHz U-NII-2A: 5260MHz-5320MHz U-NII-2C: 5500MHz-5700MHz U-NII-3: 5745MHz -5825MHz Operation Frequency (40MHz): U-NII-1: 5190MHz-5230MHz U-NII-2A: 5270MHz-5310MHz U-NII-2C: 5510MHz-5670MHz U-NII-3: 5755MHz -5795MHz Operation Frequency (80MHz): U-NII-1: 5210MHz U-NII-2A: 5290MHz U-NII-2C: 5530MHz, 5610MHz U-NII-3: 5775MHz Channel number (20MHz): U-NII-1: 4, U-NII-2A: 4, U-NII-2C: 11, U-NII-3: 5 Channel number (40MHz): U-NII-1: 2, U-NII-2A: 2, U-NII-2C: 5, U-NII-3: 2 Channel number (80MHz): U-NII-1: 1, U-NII-2A: 1, U-NII-2C: 2, U-NII-3: 1 Modulation Type: 802.11a: OFDM (64QAM, 16QAM, QPSK, BPSK) 802.11n: OFDM (BPSK, QPSK, 16QAM, 64QAM) 802.11ac: OFDM (BPSK, QPSK, 16QAM, 64QAM, 256QAM) Channel Spacing: 802.11a/n(HT20)/ac(HT20): 20MHz 802.11n(HT40)/ac(HT40): 40MHz 802.11ac(HT80): 80MHz DFS Function: Slave without Radar de…

Text truncated - open the document above for the full version.

Test Report

Dongguan YB Electronic Co.,LTD Room 101,Building 2,No.9,Xinfa Road,Lin Village,Tangxia Town,Dongguan,Guangdong Tel:+86-769-81777126 Website:www.ubuant.com 承 认 书 SPECIFICATION FOR APPROVAL 客 户 名 称 CUSTOMER NAME: 产 品 名 称 PRODUCT NAME: 2.4/5G Antenna 客 户 料 号 CUSTOMER P/N: 优比电子料号 UB P/N: UB02S58B5D901A REV: A MANUFACTURER SIGNATURE CUSTOMER SIGNATURE CHECKED BY: Victor APPROVED BY: DATE: 2021/5/31 Dongguan YB Electronic Co.,LTD Room 101,Building 2,No.9,Xinfa Road,Lin Village,Tangxia Town,Dongguan,Guangdong Tel:+86-769-81777126 We bsite:www.ubuant.com 1.规格 表 Electrical Specification: 产品主要技术参数 Technical specification 主要技术指标 technical index Main technical specifications 频率范围 frequency domain (MHZ) 2400~2500/ 5150~5850 Frequency Range (MHZ) 2400~2500/ 5150~ 5850 特性阻抗 c haracteristic impedance (Ω) 50 I mpedance(Ω) 50 峰值增益 p eak gain (dBi) 2.4G: 4.25 U-NII-1: 4.12 U-NII-2A: 4.08 U-NII-2C: 4.21 U-NII-3: 4.23 P eak Gain(dBi) 2.4G: 4.25 U-NII-1: 4.12 U-NII-2A: 4.08 U-NII-2C: 4.21 U-NII-3: 4.23 输出电压 驻 波比 VSWR ≤2 V SWR ≤2 极化方式 polarization 线极化 linear polarization Polarization Linear 连接方式 connection type SMA Antenna Type Dipole 物理 性能 Physical Properties Physical Properties 天线本体材料 TPE Antenna Base TPE Dongguan YB Electronic Co.,LTD Room 101,Building 2,No.9,Xinfa Road,Lin Village,Tangxia Town,Dongguan,Guangdong Tel:+86-769-81777126 Website:www.ubuant.com 工作温度 -20°C~ +50°C Operating Temp -20°C~+50°C 保存温度 -20°C~+50°C Storage Temp -20°C~+50°C Dongguan YB Electronic Co.,LTD Room 101,Building 2,No.9,Xinfa Road,Lin Village,Tangxia Town,Dongguan,Guangdong Tel:+86-769-81777126 Website:www.ubuant.com 3.测试报告 Test report 3.1 :网络分析仪测试报告 Network analyzer test report 3.2 :2D、3D Raditation Pattern(整机数据 complete machine data) 3.2.1 效率及增益 Efficiency post gain Frequency (MHz) Efficiency (%) Peak Gain / dB 2 400 63.17 4.25 2450 54.47 3.63 2500 58.26 4.04 5150 51.2 4.12 5350 50.99 4.08 5550 55.3 4.21 5750 54.15 4.23 5850 52.18 4.19 Dongguan YB Electronic Co.,LTD Room 101,Building 2,No.9,Xinfa Road,Lin Village,Tangxia Town,Dongguan,Guangdong Tel:+86-769-81777126 We bsite:www.ubuant.com 240 0MHz 5 150MHz 5 750MHz Dongguan YB Electronic Co.,LTD Room 101,Bui lding 2,No.9,Xinfa Road,Lin Village,Tangxia Town,Dongguan,Guangdong Tel:+86-769-81777126 Websit e:www.ubuant.com 3.3 天线尺寸 Antenna Size

Test Report

Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221200052502 Page: 1 of 63 Winkey Wang EMC Technical Manager TEST REPORT Application No.: FYCR2212000525AT Applicant: Armatura LLC Address of Applicant: 190 Bluegrass Valley Parkway Alpharetta, GA 30005, USA Manufacturer: Armatura LLC Address of Manufacturer: 190 Bluegrass Valley Parkway Alpharetta, GA 30005, USA Factory: Armatura Tech Co., Ltd Address of Factory: 999/120-121 Moo 15 Bangsaothong, Samutprakarn 10570, Thailand Equipment Under Test (EUT): EUT Name: Access Control System Model No.: AHSC-1000, AHDU-1160, AHDU-1260, AHDU-1460 ♣ ♣ Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. Trade Mark: FCC ID: 2A5UQ-SCDU Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2022-12-27 Date of Test: 2023-01-09 to 2023-02-27 Date of Issue: 2023-03-02 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221200052502 Page: 2 of 63 Revision Record Version Chapter Date Modifier Remark 01 2023-03-02 Original Authorized for issue by: Tree Zhan/Project Engineer Winkey Wang/Reviewer Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221200052502 Page: 3 of 63 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Conducted Peak Output Power ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Declaration of EUT Family Grouping: Model No.: AHSC-1000, AHDU-1160, AHDU-1260, AHDU-1460 Only the model AHSC-1000 was tested, since according to the declaration from the applicant, the electrical circuit design, PCB layout, components used and internal wiring and functions were identical for the above models, with only difference on model No.. Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221200052502 Page: 4 of 63 3 Contents Page 1 COVER PAGE ..................................................................................................................................... 1 2 TEST SUMMARY ................................................................................................................................. 3 3 CONTENTS ......................................................................................................................................... 4 4 GENERAL INFORMATION .................................................................................................................. 6 4.1 DETAILS OF E.U.T. ......................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 6 4.4 TEST LOCATION ............................................................................................................................. 7 4.5 TEST FACILITY ............................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ......................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................. 7 5 EQUIPMENT LIST ............................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................11 6.1 ANTENNA REQUIREMENT ................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 6.1.2 Conclusion .....................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Simon Zhang(Product Manager)
[email protected]470-816-1970Fax: N/A

Technical Contact

Compliance Certification Services (Kunshan) IncWinkey Wang
[email protected]+8613510914121

Fuyong Lab Xinlong Techno Park Fengtang Road · Shenzhen · China

Non-Technical Contact

Compliance Certification Services (Kunshan) IncWinkey Wang
[email protected]+8613510914121

Test Firm

Compliance Certification Services (Kunshan) IncLina Ye
[email protected]8613798526121

Technical Specifications

#Rule PartsFrequency RangePower Output
315C2.42 GHz - 2.45 GHz35.20 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20MHz, 40MHz bandwidth modes.

Other Applications from Armatura LLC

2A5UQ-FT10

Smart Access Control Terminal

Jul 17, 2024

Equipment Class

DTS - Digital Transmission System
2A5UQ-VG10

Smart Reader

Feb 04, 2024

Equipment Class

DTS - Digital Transmission System
Smart Access Control Terminal - FCC ID 2A5UQ-OMNIAC20W - Armatura LLC
2A5UQ-OMNIAC20W

Smart Access Control Terminal

Jul 11, 2023

Equipment Class

DTS - Digital Transmission System
Smart Reader - FCC ID 2A5UQ-EP30CF - Armatura LLC
2A5UQ-EP30CF

Smart Reader

Apr 23, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter