FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mulberry tech group LLC/
  3. 2A6B4-FIGF31

2A6B4-FIGF31mobile phone

Mulberry tech group LLC
mobile phone - FCC ID 2A6B4-FIGF31 - Mulberry tech group LLC
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jun 19, 2024
Application Purpose
Original Equipment
Date of Application
Jun 19, 2024
Equipment Note
mobile phone
Frequency Range
2402.00000000 - 2480.00000000
Company
Mulberry tech group LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

-1- F31 Android12istheOperatingSystemforyourSmartphoneF31. -2- INTRODUCTION ThanksforchoosingF31,DoubleSIMAndroid,4Gsmartphonebasedon1.3GHz QuadCoreProcessor.ThissmartphoneisrunningonAndroid12OS.Ifyou’dlikeyour phonetolivealongandfruitfullife,pleasereadthisguidecarefullyandkeepitforfuture reference.Youneverknowwhenyoumightneedit. Anddon’tworryifthepicturesweusetodemonstrateyourphone’sfunctionslookalittle differentfromwhatyouseeonitsscreen.It’sthefunctionsthatmatter. -3- 1Safety 1.1SafetyPrecautions Pleasereadthroughthefollowingbriefingscarefullyandactinaccordance withtheserules,soastopreventcausinganydangerorviolatinganylaw. SARValue  W/kg@1g(Head)W/kg@1g(Body) Usecellphonewhenthesignalstrengthisgood.Keepyourcallsshortorinsteaduse headsetorsendatextmessage.Thisadviceappliesespeciallytochildren, adolescentsandpregnantwomen. IfyouareusingaBluetoothheadsetdevice,pleasemakesureithasalowpower emitter. ROHSDeclaration DeclarationofConformitywiththerequirementsofthee-wasteManagementRules,2011 (adoptedbyNotificationS.O.1035(E)ofMinistryofEnvironmentandForests) TheProductisinconformitywiththerequirementsofRule13ofthee-wasteRules. Thecontentofhazardoussubstancewiththeexemptionoftheapplicationslistedin SCHEDULEIIofthee-wasteRules: a.Lead(Pb)–notover0.1%byweight; b.Cadmium(Cd)–notover0.01%byweight; c.Mercury(Hg)–notover0.1%byweight; d.Hexavalentchromium(Cr6+)–notover0.1%byweight; e.Polybrominatedbiphenyls(PBBs)–notover0.1%byweight; f.Polybrominateddiphenylethers(PBDEs)–notover0.1%byweight. 1.2Usingyourphonesafely OnTheRoad Usingaphonewhiledrivingisillegalinmanycountries.Pleasefollowlocallawsanddrive safelyatalltimes. NearSensitiveElectronics Don’tuseyourphonenearsensitiveelectronicequipment–particularlymedicaldevices suchaspacemakers–asitcouldcausethemtomalfunction.Itcanalsointerferewiththe operationoffiredetectorsandotherautomatic-controlequipment. -4- Formoreinformationabouthowyourphoneaffectspacemakersorotherelectronic equipment,pleasecontactthemanufactureroryourlocaldistributor. YourphonemaycauseinterferencewhenusednearTVs,radiosorautomatedoffice equipment. WhileFlying Yourphonecancauseinterferencewithaircraftequipment.Soit’sessentialyoufollow airlineregulations.Andifairlinepersonnelaskyoutoswitchoffyourphone,ordisableits wirelessfunctions,pleasedoastheysay. InHospital Yourphonemayinterferewiththenormaloperationofmedicalequipment.Followall hospitalregulationsandturnitoffwhenyou’reaskedtobypostedwarningsormedical staff. AtaPetrolStation Don’tuseyourphoneatpetrolstations.Infact,it’salwaysbesttoswitchoffwhenever you’renearfuels,chemicalsorexplosives. AroundWater Keepyourphoneawayfromwater(oranyotherliquid).It’snotawaterproofmodel. MakingRepairs Nevertakeyourphoneapart.Pleaseleavethattotheprofessionals.Unauthorisedrepairs couldbreakthetermsofyourwarranty. BrokenAntenna Don’tuseyourphoneiftheantennaisdamaged,asitcouldcauseinjury. AroundChildren Keepyourmobileoutofchildren’sreach.Itshouldneverbeusedasatoyanditmightnot -5- begoodfortheirhealth. OriginalAccessories Onlyusetheoriginalaccessoriessuppliedwithyourphoneorthoseapprovedbythe manufacturer.Usingunapprovedaccessoriesmayaffectperformance,makethewarranty void,breaknationalregulationsontheuseofmobilephones,orevencauseinjury. NearExplosives Turnoffyourphoneinornearareaswhereexplosivematerialsareused.Alwaysobey locallawsandturnoffyourphonewhenrequested. EmergencyCalls Tomakeanemergencycallyourphonemustbeturnedonandinanareawherethere’s networkcoverage.Dialthenationalemergencynumberandpress‘send’.Explainexactly whereyouareanddon’thangupuntilhelphasarrived. WorkingTemperature Theworkingtemperatureforthephoneisbetween0Degreeand40DegreeCelcius. Pleasedon’tusethephoneoutsidetherange.Usingthephoneundertoohighortoolow temperaturemightcauseproblems. Atveryhighvolume,prolongedlisteningtoamobilephonecandamage yourhearing. -6- 2UnderstandingyourPhone 2.1YourPhone 2.2DescriptionIcons KeysFunctions -7- Hangup Pressthisbuttontoreturnhomefromanyapplicationorinterface. Whenthescreenisoff,shortpressittoturnonthescreen,short pressittoturnoffthescreenwhenonthehomepage. Youcanpressittorejectthecallorhangupduringanincomingcall orcall. Longpressittoopenthephone’smenu,thenyoucouldchooseto restartphoneorturnoffthephone. Menu Insomeapplicationinterfaces,youcanclickonittobringupthe applicationmenu. Intheapplicationinterfacethatsupportsthemouse,youcancontrol whethertousethemousefunctionbylongpressingit, providedthatyouhaveenabledthemousefunctionofthe applicationinSettings->System->Mousecontrol. Inthethird-partyapplicationinterface,andthemousemodeisused, youcanswitchbetweenthemousemodeorthewheel modebypressingit. -8- Back Pressittoreturntothepreviousinterface,ortoclosedialog box,options,menunotificationpanelorthekeypad. Dial Pressthisbuttontocalllogfromanyapplicationorinterface. Afterenteringthenumberonthedialpad,clickonittocallthis number. Up Whenusingmousemode,youcanmovethemousepositionby short-pressingitorlong-pressingit. Whenthemousemodeisturnedoff,youcanmovethecursor positionbyshort-pressingitorlong-pressingit. Down Whenusingmousemode,youcanmovethemousepositionby short-pressingitorlong-pressingit. Whenthemousemodeisturnedoff,youcanmovethecursor positionbyshort-pressingitorlong-pressingit. Whenonthehomepage,youcanbringupthenotificationbarby longpressingit. Left Whenusingmousemode,youcanmovethemousepositionby short-pressingitorlong-pressingit. -9- Whenthemousemodeisturnedoff,youcanmovethecursor positionbyshort-pressingitorlong-pressingit. Right Whenusingmousemode,youcanmovethemousepositionby short-pressingitorlong-pressingit. Whenthemousemodeisturnedoff,youcanmovethecursor positionbyshort-pressingitorlong-pressingit. OK Thecursorselectsthemenuorthemouseselectsthemenu,you canclickoktoconfirm.Whentheconfirmationmenuisnot displayed,youcanalsoclickoktoconfirm. Numeric keyboard (0~9,*,#) Youcanentercharactersthroughthenumerickeyboardinthe editinginterfaceorthedialinterface. Youcanquicklyenterthedialpadthroughthenumerickeyboardon thehomepage. Somecharacter…

Text truncated - open the document above for the full version.

Attestation Statements

MulberrytechgroupLLC FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 6/18/24 U.S.AgentDesignation MulberrytechgroupLLCacknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStatesto actastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID:2A6B4- FIGF31): NameandcompanyofU.S.agent:MulberrytechgroupLLC PhysicalU.S.addressofagent:108Wallst,lakewood,NewJersey,08701,USA FRNofU.S.agent:0032238578 EmailaddressofU.S.agent:[email protected] MulberrytechgroupLLCacknowledgestheirobligationtoacceptserviceofprocessonbehalfofMulberrytech groupLLC. MulberrytechgroupLLCwiththeFRN0032238578acceptsitsobligationtomaintainanagentforserviceof processintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission- relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature Joasoussan CEO MulberrytechgroupLLC Signature Joasoussan CEO MulberrytechgroupLLC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Mulberry tech group LLC Address: 108 Wall st, lakewood, New Jersey 08701, United States Phone: +1-9177405447 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-06-17 Printed Name of Signee / Title: Joa Soussan / CEO Company: Mulberry tech group LLC Address: 108 Wall st, lakewood, New Jersey 08701, United States Phone: +1-9177405447 Fax: +1-9177405446 Email: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2A6B4-FIGF31 F31 We, applicant Company Name: Mulberry tech group LLC Address: 108 Wall st, lakewood, New Jersey 08701, United States Phone: +1-9177405447 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-06-17 Printed Name of Signee / Title: Joa Soussan / CEO Company: Mulberry tech group LLC Address: 108 Wall st, lakewood, New Jersey 08701, United States Phone: +1-9177405447 Fax: +1-9177405446 Email: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2A6B4-FIGF31 F31 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Tolerance The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-06-17 Printed Name of Signee / Title: Joa Soussan / CEO Company: Mulberry tech group LLC Address: 108 Wall st, lakewood, New Jersey 08701, United States Phone: +1-9177405447 Fax: +1-9177405446 Email: [email protected]

External Photos

Page1of4FCCID:2A6B4-FIGF31 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2A6B4-FIGF31 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2A6B4-FIGF31 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2A6B4-FIGF31 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8

ID Label/Location Info

Page1of1FCCID:2A6B4-FIGF31 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L3.0cmxW1.5cm) LabelLocation mobilephone Model:F31 FCCID:2A6B4-FIGF31

Internal Photos

Page1of3FCCID:2A6B4-FIGF31 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 LTEDiversityAntenna Bluetooth/WIFIAntenna GSM/WCDMA/LTEAntenna Page2of3FCCID:2A6B4-FIGF31 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2A6B4-FIGF31 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5

RF Exposure Info

Page 1 of 8 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A Detailed System Check Results 1. System Performance Check System Performance Check 750 MHz Head System Performance Check 835 MHz Head System Performance Check 1750 MHz Head System Performance Check 1900 MHz Head System Performance Check 2450 MHz Head System Performance Check 5250 MHz Head System Performance Check 5750 MHz Head Page 2 of 8 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/6/4 Test Laboratory: LCS-SAR Lab System Check_750Mhz DUT: D750V3; Type: D750V3; Serial: 1191 Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1 Medium parameters used: f = 750 MHz; σ = 0.877 S/m; ε r = 42.685; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration: • Probe: EX3DV4 - SN3805; ConvF(9.66, 9.66, 9.66); Calibrated: 2023/11/23; • Sensor-Surface: 2mm (Mechanical Surface Detection) • Electronics: DAE3 Sn373; Calibrated: 2024/1/3 • Phantom: SAM v5.0; Type: SAM; Serial: 1850 • DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (9x9x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.54 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 55.73 V/m; Power Drift = -0.17 dB Peak SAR (extrapolated) = 3.32 W/kg SAR(1 g) = 2.11 W/kg; SAR(10 g) = 1.37 W/kg Maximum value of SAR (measured) = 2.66 W/kg 0 dB = 2.66 W/kg = 4.25 dBW/kg Page 3 of 8 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/6/5 Test Laboratory: LCS-SAR Lab System Check_835Mhz DUT: D835V2; Type: D835V2; Serial: 4d124 Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.874 S/m; ε r = 40.754; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration: • Probe: EX3DV4 - SN3805; ConvF(9.26, 9.26, 9.26); Calibrated: 2023/11/23; • Sensor-Surface: 2mm (Mechanical Surface Detection) • Electronics: DAE3 Sn373; Calibrated: 2024/1/3 • Phantom: SAM v5.0; Type: SAM; Serial: 1850 • DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (5x18x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 3.11 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 54.23 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 3.65 W/kg SAR(1 g) = 2.34 W/kg; SAR(10 g) = 1.56 W/kg Maximum value of SAR (measured) = 3.19 W/kg 0 dB = 3.19 W/kg = 5.04 dBW/kg Page 4 of 8 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/6/6 Test Laboratory: LCS-SAR Lab System Check_1750Mhz DUT: D1750V2; Type: D1750V2; Serial: 1035 Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1750 MHz; σ = 1.371 S/m; ε r = 40.436; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration: • Probe: EX3DV4 - SN3805; ConvF(8.16, 8.16, 8.16); Calibrated: 2023/11/23; • Sensor-Surface: 2mm (Mechanical Surface Detection) • Electronics: DAE3 Sn373; Calibrated: 2024/1/3 • Phantom: SAM v5.0; Type: SAM; Serial: 1850 • DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 11.2 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 82.77 V/m; Power Drift = -0.12 dB Peak SAR (extrapolated) = 16.7 W/kg SAR(1 g) = 9.02 W/kg; SAR(10 g) = 4.74 W/kg Maximum value of SAR (measured) = 12.9 W/kg 0 dB = 12.9 W/kg = 11.11 dBW/kg Page 5 of 8 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/6/7 Test Laboratory: LCS-SAR Lab System Check_1900Mhz DUT: D1900V2; Type: D1900V2; Serial: 5d055 Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1900 MHz; σ = 1.354 S/m; ε r = 40.245; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration: • Probe: EX3DV4 - SN3805; ConvF(7.85, 7.85, 7.85); Calibrated: 2023/11/23; • Sensor-Surface: 2mm (Mechanical Surface Detection) • Electronics: DAE3 Sn373; Calibrated: 2024/1/3 • Phantom: SAM v5.0; Type: SAM; Serial: 1850 • DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 12.5 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 90.87 V/m; Power Drift = -0.19 dB Peak …

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 27 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix B Detailed Test Results 1. GSM GSM850 for Head& Body GSM1900 for Head& Body 2. WCDMA WCDMA Band II for Head& Body WCDMA Band V for Head& Body 3. LTE LTE Band 2 for Head& Body LTE Band 5 for Head& Body LTE Band 12 for Head& Body LTE Band 13 for Head& Body LTE Band 66 for Head& Body LTE Band 71 for Head& Body 4. WIFI WIFI 2.4GHz for Head& Body WIFI 5.2GHz for Head& Body WIFI 5.8GHz for Head& Body Page 2 of 27 FCC ID: XXX-YYY Report No.: LCSA05214038EB Date: 2024/6/5 Test Laboratory: LCS-SAR Lab GSM 850 190CH Left Cheek DUT: mobile phone; Type: F31; Serial: A240521043-1 Communication System: UID 0, GSM (0); Frequency: 836.6 MHz;Duty Cycle: 1:1 Medium parameters used: f = 836.6 MHz; σ = 0.922 S/m; ε r = 41.785; ρ = 1000 kg/m 3 Phantom section: Left Section DASY Configuration: • Probe: EX3DV4 - SN3805; ConvF(9.26, 9.26, 9.26); Calibrated: 2023/11/23; • Sensor-Surface: 2mm (Mechanical Surface Detection) • Electronics: DAE3 Sn373; Calibrated: 2024/1/3 • Phantom: SAM v5.0; Type: SAM; Serial: 1850 • DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (8x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.238 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.574 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 0.275 W/kg SAR(1 g) = 0.202 W/kg; SAR(10 g) = 0.132 W/kg Maximum value of SAR (measured) = 0.242 W/kg 0 dB = 0.242 W/kg = -6.16 dBW/kg Page 3 of 27 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/6/5 Test Laboratory: LCS-SAR Lab GSM 850 GPRS 3TX 190CH Rear side 10mm DUT: mobile phone; Type: F31 Serial: A240521043-1 Communication System: UID 0, GPRS (0); Frequency: 836.6 MHz;Duty Cycle: 1: 2.77 Medium parameters used: f = 836.6 MHz; σ = 0.922 S/m; ε r = 41.785; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration: • Probe: EX3DV4 - SN3805; ConvF(9.26, 9.26, 9.26); Calibrated: 2023/11/23; • Sensor-Surface: 2mm (Mechanical Surface Detection) • Electronics: DAE3 Sn373; Calibrated: 2024/1/3 • Phantom: SAM v5.0; Type: SAM; Serial: 1850 • DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (8x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.436 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 19.52 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 0.478 W/kg SAR(1 g) = 0.308 W/kg; SAR(10 g) = 0.167 W/kg Maximum value of SAR (measured) = 0.444 W/kg 0 dB = 0.444 W/kg = -3.53 dBW/kg Page 4 of 27 FCC ID: XXX-YYY Report No.: LCSA05214038EB Date: 2024/6/7 Test Laboratory: LCS-SAR Lab GSM 1900 661CH Left Cheek DUT: mobile phone; Type: F31 Serial: A240521043-1 Communication System: UID 0, GSM (0); Frequency: 1880 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1880 MHz; σ = 1.433 S/m; ε r = 40.254; ρ = 1000 kg/m 3 Phantom section: Left Section DASY Configuration: • Probe: EX3DV4 - SN3805; ConvF(7.85, 7.85, 7.85); Calibrated: 2023/11/23; • Sensor-Surface: 2mm (Mechanical Surface Detection) • Electronics: DAE3 Sn373; Calibrated: 2024/1/3 • Phantom: SAM v5.0; Type: SAM; Serial: 1850 • DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (8x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.079 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.774 V/m; Power Drift =0.09 dB Peak SAR (extrapolated) = 0.089 W/kg SAR(1 g) = 0.079 W/kg; SAR(10 g) = 0.036 W/kg Maximum value of SAR (measured) = 0.082 W/kg 0 dB = 0.082 W/kg = -10.86 dBW/kg Page 5 of 27 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/6/7 Test Laboratory: LCS-SAR Lab GSM 1900 GPRS 3TX 661CH Rear side 10mm DUT: mobile phone; Type: F31 Serial: A240521043-1 Communication System: UID 0, GPRS (0); Frequency: 1880 MHz;Duty Cycle: 1:2.77 Medium parameters used: f = 1880 MHz; σ = 1.433 S/m; ε r = 40.254; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration: • Probe: EX3DV4 - SN3805; ConvF(7.85, 7.85, 7.85); Calibrated: 2023/11/23; • Sensor-Surface: 2mm (Mechanical Surface Detection) • Electronics: DAE3 Sn373; Calibrated: 2024/1/3 • Phantom: SAM v5.0; Type: SAM; Serial: 1850 • DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (8x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.265 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 11.75 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 0.283 W/kg SAR(1 g) = 0.164 W/kg; SAR(10 g) = 0.096 W/kg Maximum value of SAR (measured) = 0.277 W/kg 0 dB = 0.277 W/kg = -5.58 dBW/kg Page 6 of 27 FCC ID: XXX-YYY Report No.: LCSA05214038EB Date: 2024/6/7 Test Laboratory: LCS-SAR Lab WCDMA Band II RMC 9538CH Left Cheek DUT: mobile phone; Type: F31 Serial: A240521043-1 Communication System: UID 0, WCDMA (0); Frequency: 1907…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix C Calibration certificate 1. Dipole D750V3-SN 1191(2023-06-15) D835V2-SN 4d124(2023-10-24) D1750V2-SN 1035(2023-06-12) D1900V2-SN 5d055 (2023-10-20) D2450V2-SN 808(2023-10-23) D5GHzV2-SN 1046(2023-10-23) 2. DAE DAE3-SN 373(2024-1-3) 3. Probe EX3DV4-SN 3805(2023-11-23) Page 2 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 3 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 4 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 5 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 6 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 7 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 9 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 10 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 11 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 12 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 13 of 52 FCC ID: 2A6B4-FIGF31 Report No.: LCSA05214038EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-825…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Joa soussan(CEO)
[email protected]9177405447Fax: 9177405446

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 10 mm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The device also contains BLE, 2.4GHz WLAN, 5GHz WLAN and 2G/3G/4G transmitters.

Other Applications from Mulberry tech group LLC

Fixed wireless phone - FCC ID 2A6B4-FIGHP15 - Mulberry tech group LLC
2A6B4-FIGHP15

Fixed wireless phone

Aug 05, 2024

Equipment Class

DTS - Digital Transmission System
Mobile Phone - FCC ID 2A6B4-FIGF45 - Mulberry tech group LLC
2A6B4-FIGF45

Mobile Phone

Jul 24, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Mobile Phone - FCC ID 2A6B4-FIGF52 - Mulberry tech group LLC
2A6B4-FIGF52

Mobile Phone

Dec 14, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter