FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mulberry tech group LLC/
  3. 2A6B4-FIGHP15

2A6B4-FIGHP15Fixed wireless phone

Mulberry tech group LLC
Fixed wireless phone - FCC ID 2A6B4-FIGHP15 - Mulberry tech group LLC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 05, 2024
Application Purpose
Original Equipment
Date of Application
Aug 05, 2024
Equipment Note
Fixed wireless phone
Frequency Range
2412.00000000 - 2462.00000000
Company
Mulberry tech group LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Warning This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. Specific Absorption Rate (SAR) information: This Mulberry tech group LLC meets the government's requirements for exposure to radio waves. The and thorough evaluation of scientific studies.The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. FCC RF Exposure Information and Statement the SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types: Fixed wireless phone has also been tested against this SAR limit. This device was tested for typical body-worn operations with the back of the Fixed wireless phone kept 0mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain an 0mm separation distance between the user's body and the back of the Fixed wireless phone. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided.

Attestation Statements

MulberrytechgroupLLC FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 8/2/24 U.S.AgentDesignation MulberrytechgroupLLCacknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStatesto actastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID:2A6B4- FIGHP15): NameandcompanyofU.S.agent:MulberrytechgroupLLC PhysicalU.S.addressofagent:108Wallst,lakewood,NewJersey,08701,USA FRNofU.S.agent:0034614016 EmailaddressofU.S.agent:[email protected] MulberrytechgroupLLCacknowledgestheirobligationtoacceptserviceofprocessonbehalfofMulberrytech groupLLC. MulberrytechgroupLLCwiththeFRN0034614016acceptsitsobligationtomaintainanagentforserviceof processintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission- relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature Joasoussan CEO MulberrytechgroupLLC Signature Joasoussan CEO MulberrytechgroupLLC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Mulberry tech group LLC Address: 108 Wall st, lakewood, New Jersey 08701, United States Phone: +1-9177405447 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-08-02 Signature Date Name / Title: Joa Soussan / CEO Company: Mulberry tech group LLC Address: 108 Wall st, lakewood, New Jersey 08701, United States Phone: +1-9177405447 Fax: +1-9177405446 E-Mail: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2A6B4-FIGHP15 HP15 We, applicant Company Name: Mulberry tech group LLC Address: 108 Wall st, lakewood, New Jersey 08701, United States Phone: +1-9177405447 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-08-02 Signature Date Name / Title: Joa Soussan / CEO Company: Mulberry tech group LLC Address: 108 Wall st, lakewood, New Jersey 08701, United States Phone: +1-9177405447 Fax: +1-9177405446 E-Mail: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2A6B4-FIGHP15 HP15 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-08-02 Signature Date Name / Title: Joa Soussan / CEO Company: Mulberry tech group LLC Address: 108 Wall st, lakewood, New Jersey 08701, United States Phone: +1-9177405447 Fax: +1-9177405446 E-Mail: [email protected]

Cover Letter(s)

Page 1 of 1 Rev.2.0 Mulberry tech group LLC WIFI Channel 12 and 13 Declaration Letter We declare the equipment identified below with regards to Channel 12 and 13 capabilities for FCC ID: 2A6B4-FIGHP15 Declaration Product hardware does not have the capability to operate on Channel 12 and 13. Product hardware has the capability to operate on Channel 12 and 13. However, these two channels will be disabled via software and will not be accessible to user. Product hardware has the capability to operate on Channel 12 and 13. However, all the operated channels can’t be changed in the RF parameter via software. All channels have complied with all of the requirements sets out in FCC Part 15.247. Product hardware has the capability to operate on WiFi Channel 12 and 13, and meets the requirements of KDB 594280 D01 v02r01. Please note: 1.) By default, this device operates in a mode that is compliant with the U.S. requirements. 2.) This device will also use supplemental information such as geo- location data to determine that it is operating outside the U.S., if necessary, to change its power. Such supplemental data will be derived from the following: Global Navigation Satellite System (GNSS)7 sensors in the device Mobile Country Code (MCC),8 or MCC with a Mobile Network code (MNC), received from a CMRS9 carrier and received directly by a receiver on the device Country information derived from multiple adjacent access points (for example using IEEE Std 802.11d provisions) may be permitted on case-by-case basis Other suitable geo-location data based on IP addresses or other reliable source. Name / Title: Joa Soussan / CEO Signature: Phone: +1-9177405447 Email: [email protected] Date: 2024-08-02

External Photos

Page 1 of 5 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10

ID Label/Location Info

Page 1 of 1 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L: 5.5cm x W: 4.5cm) Label Location Fixed wireless phone Test Model: HP15 FCC ID: 2A6B4-FIGHP15

Internal Photos

Page 1 of 11 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 11 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 11 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 2G/3G/4G MAIN ANT Page 4 of 11 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 11 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 11 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 2G/3G/4G DIV ANT BT/WIFI ANT Page 7 of 11 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13 Fig. 14 Page 8 of 11 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 15 Fig. 16 Page 9 of 11 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 17 Fig. 18 Page 10 of 11 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 19 Fig. 20 Page 11 of 11 FCC ID: 2A6B4-FIGHP15 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 21 Fig. 22

RF Exposure Info

Page 1 of 10 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A Detailed System Check Results 1. System Performance Check System Performance Check 750 MHz Head System Performance Check 835 MHz Head System Performance Check 1750 MHz Head System Performance Check 1900 MHz Head System Performance Check 2450 MHz Head System Performance Check 2600 MHz Head System Performance Check 5250 MHz Head System Performance Check 5600 MHz Head System Performance Check 5750 MHz Head Page 2 of 10 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/17 Test Laboratory: LCS-SAR Lab System Check 750 MHz DUT: D750V2; Type: D750V2; Serial: 1191 Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1 Medium parameters used: f = 750 MHz; σ = 0.874 S/m; ε r = 41.685; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(9.66, 9.66, 9.66); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.58 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 55.41 V/m; Power Drift = -0.11 dB Peak SAR (extrapolated) = 3.14 W/kg SAR(1 g) = 2.20 W/kg; SAR(10 g) = 1.32 W/kg Maximum value of SAR (measured) = 2.66 W/kg 0 dB = 2.66 W/kg = 4.25 dBW/kg Page 3 of 10 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/19 Test Laboratory: LCS-SAR Lab System Check 835 MHz DUT: D835V2; Type: D835V2; Serial: 4d124 Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.911 S/m; ε r = 42.632; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(9.26, 9.26, 9.26); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 3.11 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 53.21 V/m; Power Drift = 0.19 dB Peak SAR (extrapolated) = 3.52 W/kg SAR(1 g) = 2.48 W/kg; SAR(10 g) = 1.69 W/kg Maximum value of SAR (measured) = 3.20 W/kg 0 dB = 3.20 W/kg = 5.05 dBW/kg Page 4 of 10 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/20 Test Laboratory: LCS-SAR Lab System Check 1750 MHz DUT: D1750V2; Type: D1750V2; Serial: 1035 Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1750 MHz; σ = 1.358 S/m; ε r = 40.642; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(8.16, 8.16, 8.16); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 13.3 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 82.65 V/m; Power Drift = 0.18 dB Peak SAR (extrapolated) = 16.2 W/kg SAR(1 g) = 9.08 W/kg; SAR(10 g) = 4.80 W/kg Maximum value of SAR (measured) = 12.6 W/kg 0 dB = 12.6 W/kg = 11.00 dBW/kg Page 5 of 10 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/22 Test Laboratory: LCS-SAR Lab System Check 1900 MHz DUT: D1900V2; Type: D1900V2; Serial: 5d055 Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1900 MHz; σ = 1.426 S/m; ε r = 39.475; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.85, 7.85, 7.85); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 13.9 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Mea…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 16 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix B Detailed Test Results 1. GSM GSM850 for Body GSM1900 for Body 2. WCDMA WCDMA Band II for Body WCDMA Band V for Body 3. LTE LTE Band 2 for Body LTE Band 5 for Body LTE Band 12 for Body LTE Band 13 for Body LTE Band 66 for Body LTE Band 71 for Body 4. WIFI WIFI 2.4GHz for Body WIFI 5.2GHz for Body WIFI 5.3GHz for Body WIFI 5.5GHz for Body WIFI 5.8GHz for Body Page 2 of 16 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/19 Test Laboratory: LCS-SAR Lab GSM 850 GPRS 3TS 190CH Rear side 0mm DUT: Fixed wireless phone ; Type: HP15; Serial: A240716045-1 Communication System: UID 0, GPRS (0); Frequency: 824.2 MHz;Duty Cycle: 1:2.77 Medium parameters used (interpolated): f = 824.2 MHz; σ = 0.927 S/m; ε r = 41.652; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(9.26, 9.26, 9.26); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (9x12x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.896 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 8.641 V/m; Power Drift = -0.13 dB Peak SAR (extrapolated) = 1.28 W/kg SAR(1 g) = 0.554 W/kg; SAR(10 g) = 0.287 W/kg Maximum value of SAR (measured) = 0.907 W/kg 0 dB = 0.907 W/kg = -0.42 dBW/kg Page 3 of 16 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/22 Test Laboratory: LCS-SAR Lab GSM 1900 GPRS 3TS 661CH Rear side 0mm DUT: Fixed wireless phone ; Type: HP15; Serial: A240716045-1 Communication System: UID 0, GPRS (0); Frequency: 1880 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1880 MHz; σ = 1.442 S/m; ε r = 39.674; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.85, 7.85, 7.85); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (9x12x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.801 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 9.774 V/m; Power Drift = -0.15 dB Peak SAR (extrapolated) = 1.22 W/kg SAR(1 g) = 0.488 W/kg; SAR(10 g) = 0.226 W/kg Maximum value of SAR (measured) = 0.760 W/kg 0 dB = 0.760 W/kg = -1.19 dBW/kg Page 4 of 16 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/22 Test Laboratory: LCS-SAR Lab WCDMA Band II RMC 9400CH Rear side 0mm DUT: Fixed wireless phone ; Type: HP15; Serial: A240716045-1 Communication System: UID 0, WCDMA (0); Frequency: 1880 MHz;Duty Cycle: 1:1 Medium parameters used (interpolated): f = 1880 MHz; σ = 1.455 S/m; ε r = 39.688; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.85, 7.85, 7.85); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (9x12x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.974 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 10.45 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 1.14 W/kg SAR(1 g) = 0.625 W/kg; SAR(10 g) = 0.277 W/kg Maximum value of SAR (measured) = 0.988 W/kg 0 dB = 0.988 W/kg = -0.05 dBW/kg Page 5 of 16 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/19 Test Laboratory: LCS-SAR Lab WCDMA Band V RMC 4182CH Rear side 0mm DUT: Fixed wireless phone ; Type: HP15; Serial: A240716045-1 Communication System: UID 0, WCDMA (0); Frequency: 836.4 MHz;Duty Cycle: 1:1 Medium parameters used (interpolated): f = 836.4 MHz; σ = 0.922 S/m; ε r = 41.754; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(9.26, 9.26, 9.26); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/U…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 58 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix C Calibration certificate 1. Dipole D750V3-SN 1191(2023-06-15) D835V2-SN 4d124(2023-10-24) D1750V2-SN 1035(2023-06-12) D1900V2-SN 5d055 (2023-10-20) D2450V2-SN 808(2023-10-23) D2600V2-SN 1071(2023-06-20) D5GHzV2-SN 1046(2023-10-23) 2. DAE DAE3-SN 373(2024-01-03) 3. Probe EX3DV4-SN 3805(2023-11-23) Page 2 of 58 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 3 of 58 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 4 of 58 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 5 of 58 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 6 of 58 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 7 of 58 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 58 FCC ID: 2A6B4-FIGHP15 Report No.: LCSA07164058EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Joa soussan(CEO)
[email protected]9177405447Fax: 9177405446

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz38.60 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. The device supports both 20 MHz and 40 MHz bandwidth modes as described in this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. except in accordance with FCC multi-transmitter product procedures or as described in this filing. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions are 0.51 W/kg and 1.19 W/kg, respectively. Device is a client only device containing an 802.11b/g/n configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing.The device also contains Bluetooth, 5GHz WLAN and 2G/3G/4G transmitters.

Other Applications from Mulberry tech group LLC

mobile phone - FCC ID 2A6B4-FIGF31 - Mulberry tech group LLC
2A6B4-FIGF31

mobile phone

Jun 19, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Mobile Phone - FCC ID 2A6B4-FIGF45 - Mulberry tech group LLC
2A6B4-FIGF45

Mobile Phone

Jul 24, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Mobile Phone - FCC ID 2A6B4-FIGF52 - Mulberry tech group LLC
2A6B4-FIGF52

Mobile Phone

Dec 14, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter