Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
制作工艺: 80g书写纸;骑马钉,黑白印刷 尺寸: 95*142mm 此页不印刷 User Manual Personal ECG Monitor User Manual Contents 1. Introduction ........................................................ 1 2. Warnings ............................................................ 1 3. Packing List ........................................................ 4 4. Guide to Parts ................................................... 5 5. Using the Device ............................................... 7 5.1. Charge and activate your device ........... 7 5.2. Download Livenpace App........................ 8 5.3. Record your ECG ....................................... 9 5.4. View ECG measurement results ........... 12 6. Maintenance ................................................... 14 7. Troubleshooting .............................................. 15 8. Specifications .................................................. 16 9. Symbols ............................................................ 18 10. FCC Statement .............................................. 19 1 1. Introduction It is intended to record and store electrocardiogram (ECG) rhythms, and transfer records to compatible mobile App for further research or analysis. It is not a medical device and should not be used for any medical purposes or any medical conditions. It is intended only for general wellness use. 2. Warnings The ECG results (including regular heartbeat) do not guarantee that you are free from an arrhythmia or other health conditions. You should notify your physician of possible changes of your health. Do not use the device to self-diagnose heart-related conditions. Consult with your physician before making any 2 medical decision, such as altering your use of any drug or treatment. Do not continue to use the device until further instructed by a physician if your skin is irritated or inflamed around the electrodes. The device makes no warranty for any erroneously collected data or information from misuse or malfunction as a result of abuse, accidents, alteration, negligence, or failure to maintain the products as instructed. The results made by this device are preliminary screening of cardiac conditions, not a complete diagnosis. All interpretations should be reviewed by a medical professional for clinical decision-making. The device has not been tested for and is not intended for pediatric use. Keep the device away from young children. Contents may be harmful if swallowed. 3 Do not take a recording while driving or during physical activity. Do not store in extremely hot, cold, humid, wet, or bright conditions. Do not take a recording if the electrodes are dirty. Clean them first. Do not immerse the device in or expose the device to excessive liquid. Do not drop or bump with excessive force. Do not expose to strong electromagnetic fields. Do not expose the device to a magnetic resonance (MR) environment. Do not use with a cardiac pacemaker, ICDs, or other implanted electronic devices. Do not use during cautery and external defibrillation procedures. 4 Do not place the electrodes in contact with other conductive parts including the earth. Do not use with unapproved accessories. The use of unapproved accessories or transducers and cables may result in electromagnetic emissions or decreased electromagnetic immunity of this device and result in improper operation. Do not use the device adjacent to or stacked with other equipment because it may result in improper operation. 3. Packing List Main Unit USB Cable 5 4. Guide to Parts Indicator Status Description / OFF Not activated Out of battery Display screen LED indicator Electrodes Charging port 6 Green light Flashing with the rhythm of the heartbeat Recording your ECG Flashing every 5 seconds Fully charged In standby mode Orange light On Charging Flashing every 5 seconds Low Battery Blue light On Connected to the App and ready to start recording Flashing with the rhythm of the heartbeat Connected to the App and recording your ECG 7 5. Using the Device 5.1 Charge and activate your device Connect the device with power adapter by the charging cable. Note: The power adapter is not included in the package. Compatible power adapter output: DC 5V, 1A Do not use the device while charging. 8 5.2 Download Livenpace App a) Download the Livenpace App from iOS App Store or Google Play Store. Or you can scan the QR code below. Note: Be sure to use a compatible iOS or Android device. iOS: iOS 10.0 or above Android: Android 7.0 or above b) Make sure Bluetooth is turned on in Settings of your smartphone or tablet. 9 c) Launch the Livenpace App and follow the instructions in the App to set up and pair your device. Note: For more information on how to use the software, visit the website https://livenpace.com/pages/support or scan the QR code below. 5.3 Record your ECG a) Choose one of the following methods for recording ECG: 10 Lead I Hold onto the device with both hands. Note: If the ECG quality is poor with Lead I, please try to use Lead II. Lead II Hold the right electrodes with the right hand, place the left electrodes on the left leg. Chest Lead Hold the right electrodes with the right hand, place the device on the chest (below the pectoral muscles). 11 Note: Please make sure that the “R” symbol is always on the right hand or chest. DO NOT use the electrodes on a portion of the body with too much body fat, body hair or very dry skin; otherwise, a successful recording may not be possible. b) Hold still for at least 30 seconds. Note: You can turn on/off the heartbeat sound of the device in the App. c) When the recording exceeds 5 minutes or the electrodes lose contact with your skin, the device will automatically stop recording with a long beep. 80 12 5.4 View ECG measurement results Upon completion of your ECG recording, the device will display the measurement results on the screen and the records will be synced to the App. Result Description Regular…
Text truncated - open the document above for the full version.
Shenzhen Livenpace Technology Co., Ltd. Agent Authorization Company:Shenzhen Livenpace Technology Co., Ltd. Address:4F,BLD 9,Baiwangxin Industrial Park,Songbai Road,Xili Street, Nanshan District, Shenzhen, China Product Name:Personal ECG Monitor Model Number(s):HHM3 Product Description:Personal ECG Monitor We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature:Date:2022.08.10 Name:Bing Wang Title:Manager Company:ShenzhenLivenpaceTechnologyCo., Ltd.
http://www.glead.com.cnhttp://zydq.en.alibaba.com JIAXINGGLEADELECTRONICSCO.,LTD -1- SPECIFICATION No.66ZhengyuanRoad,EconomicDevelopmentZone,Jiaxing,Zhejiang,China TEL : 0086-573-83651818FAX : 0086-573-83651858 Preparedby:Checkedby:Approvedby: FormedOnDocumentVersion (V2.0) PARTNO:LA52H2450-A36 CUSTOMERPARTNO: CUSTOMERAPPROVEDBY: APPROVEDDATE: http://www.glead.com.cnhttp://zydq.en.alibaba.com JIAXINGGLEADELECTRONICSCO.,LTD -2- Tableofcontents Versionrejiggertrackrecord ........................... 3 1.Introduction .................................................................. 4 2.PartNumber ..................................................................... 4 3.Dimensions .................................................................. 4 ~ 5 4.EvaluationBoardandMatchingCircuits .......................................... 5 5.ElectricalCharacteristics ......................................................... 6 6.Characteristiccurve .................................................................. 6 7.RadiationPattern .................................................................. 7 ~ 8 8.PostDependabilityTolerance ............................................. 9 9.DependabilityTest ......................................................... 9 ~ 10 10.ReflowSolderingStandardCondition .................................... 10 11.PackagingandDimensions ................................................... 11 http://www.glead.com.cnhttp://zydq.en.alibaba.com JIAXINGGLEADELECTRONICSCO.,LTD -3- Size:5.2×2.0×1.2 1.INTRODUCTION "GLEAD"MicrowaveMulti-LayerCeramicAntennaLAseriesaredesignedtobeused inWLAN 、 WiFi 、 Bluetooth 、 PHS 、 Multiple-bandMobilephoneantenna,FM,etcand compactsizeSMDchipdesign. 2.PartNumber LA52H2450–A36 3.Dimensions(Unit:mm) AntennaFrequency:2450MHz ViaDesignSeries Multi-layerAntenna ProductName:A36 http://www.glead.com.cnhttp://zydq.en.alibaba.com JIAXINGGLEADELECTRONICSCO.,LTD -4- EvaluationBoardandMatchingCircuits 5.ElectricalCharacteristics No. ItemSpecifications 5.1 CentralFrequency(Nomatching)2790MHz AfterMatching2450MHz 5.2BandWidth100MHztyp. 90 50 Unit:mm 4.3nH 1.5pF http://www.glead.com.cnhttp://zydq.en.alibaba.com JIAXINGGLEADELECTRONICSCO.,LTD -5- 6.Characteristiccurve 7.RadiationPattern&Efficiency 5.3PeakGain3.91dBi 5.4V.S.W.R≤2.0 5.5 Polarization Linear 5.6 AzimuthBeamwidth Omni-directional 5.7 Impedance阻抗 50Ω http://www.glead.com.cnhttp://zydq.en.alibaba.com JIAXINGGLEADELECTRONICSCO.,LTD -6- coordinates : X-ZPlane Y-ZPlane X-YPlane http://www.glead.com.cnhttp://zydq.en.alibaba.com JIAXINGGLEADELECTRONICSCO.,LTD -7- 3DRadiationPattern 8PostDependabilityTolerance Frequency (MHz) 240024502500 Avg.Gain (dBi) -0.75-0.79-0.88 PeckGain (dBi) 3.373.633.91 Efficiency (%) 70.271.171.2 http://www.glead.com.cnhttp://zydq.en.alibaba.com JIAXINGGLEADELECTRONICSCO.,LTD -8- PostDependabilityTolerance(Refertothetable) 9DependabilityTest Temperaturerange25±5°C RelativeHumidityrange55~75%RH OperatingTemperaturerange-40°C~+85°C 9.1 VibrationResist Thedeviceshouldsatisfytheelectricalcharacteristicsspecifiedinparagraph8.1~8.4afterapplied tothevibrationof10to55Hzwithamplitudeof1.5mmfor2hourseachinX,YandZdirections. 9.2 DropShock Thedeviceshouldsatisfytheelectricalcharacteristicsspecifiedinparagraph8.1~8.4afterdropping ontothehardwoodenboardfromtheheightof100cmfor3timeseachfacetofthe3dimensionsofthe device. 9.3 SolderHeatProof Thedeviceshouldbesatisfiedafterpreheatingat120°C~150°Cfor120secondsanddippingin solderingSnat255°C+10°Cfor5±0.5seconds,orelectriciron300°C-10°Cfor3±0.5seconds, withoutdamnify. 9.4AdhesiveStrengthofTermination Thedevicehavenoremarkabledamageorremovaloftheterminationafterhorizontalforceof 5N(≦0603);10N(>0603)with10±1seconds. 9.5 BendingResistTest WeldtheproducttothecenterpartofthePCBwiththethickness 1.6±0.2mmastheillustrationshows,andkeepexertingforce arrow-wardonitatspeedof:1mm/S,andholdfor5±1Satthe positionof1.5mmbendingdistance,sofar,anypeelingoffofthe productmetalcoatingshouldnotbedetected. 9.6 MoistureProof Thedeviceshouldsatisfytheelectricalcharacteristicsspecifiedinparagraph8.1~8.4afterexposedto thetemperature60±2°Candtherelativehumidity90~95%RHfor96hoursand1~2hoursrecoverytime No.Item PostDependabilityTolerance 8.1CentralFrequency±5MHz 8.2BandWidth±5MHz 8.3Gain±0.1dBi 8.4V.S.W.R(inBW)±0.1 http://www.glead.com.cnhttp://zydq.en.alibaba.com JIAXINGGLEADELECTRONICSCO.,LTD -9- undernormalcondition. 9.7HighTemperatureEndurance Thedeviceshouldsatisfytheelectricalcharacteristicsspecifiedinparagraph8.1~8.4afterexposedto temperature85±5°Cfor96±2hoursand1~2hoursrecoverytimeundernormaltemperature. 9.8LowTemperatureEndurance Thedeviceshouldalsosatisfytheelectricalcharacteristicsspecifiedinparagraph8.1~8.4after exposedtothetemperature-40°C±5°Cfor96±2hoursandto2hoursrecoverytimeundernormal temperature. 9.9 TemperatureCycleTest Thedeviceshouldalsosatisfytheelectricalcharacteristicsspecifiedinparagraph8.1~8.4after exposedtothelowtemperature-40°Candhightemperature+85°Cfor30±2mineachby5cyclesand1 to2hoursrecoverytimeundernormaltemperature. 10ReflowSolderingStandardCondition 11PackagingandDimensions 11 .1PlasticTape RemarksforPackage: Reservealengthof150~200mmforthetrailerofthecarrierand250~300mmfortheleaderofthe carrierandfurther250mmofcovertapeattheleadingpartofthecarrier. 11.2Reel(3000pcs/Reel) http://www.glead.com.cnhttp://zydq.en.alibaba.com JIAXINGGLEADELECTRONICSCO.,LTD -10- 11.3StoragePeriod Productshouldbeusedwithintwelvemonthsofreceipt. MSL1/StorageTemperatureRange:-40~85degreeC,Humidity:<85%RH
ShenzhenLivenpaceTechnologyCo., Ltd. Date: 2022.08.10 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject; Request for Confidentiality FCC ID: 2A728-0003 To WhomIt May Concern, Pursuantto the provisionsof the Commission’s rules Title 47 Sections§0.457 and §0.459,we are requestingthe Commissionto withholdthe followingattachment(s)as confidential documentsfrom public disclosureindefinitely. Thesedocumentscontaindetailedsystemand equipmentdescriptionsand are consideredas proprietaryinformationin operationof the equipment.The public disclosureof these documents might be harmfulto our companyand would give competitorsan unfair advantagein the market. SchematicDiagram Block Diagram Parts List OperationalDescription Tune-upProcedure In additionalto abovementioneddocuments,in order to complywith the marketingregulations in Title 47 CFR §2.803 and the importationrules in Title 47 CFR §2.1204,while ensuringthat businesssensitiveinformationremainsconfidentialuntil the actualmarketingof newly authorizeddevices,we requestShort Term Confidentialityof the followingattachment(s); ExternalPhotos Test Setup Photos InternalPhotos User Manual For 45 days, pursuantto PublicNoticeDA 04-1705. OR For 180 days pursuantto KDB 726920D01. It is our understandingthat all measurementtest reports,FCC ID label formatand correspondenceduringthe certificationreviewprocesscannotbe grantedas confidential documentsand this informationwill be availablefor public reviewonce the grant of equipment authorizationis issued. Sincerely, Signature: Name:Bing Wang Title: Manager
EUTPHOTOS(ExternalPhotos)
REV.A ART-210-05310-01 HHM3上壳(Livenpace)-已打标 HHM3上壳(Livenpace)-已打标 1 OF 1 NAMEDATE D ESIGN CHECKED APPROVED SCALE:1:1 SIZE: A4 TITLE: PART NO.: MATERIAL: PC+ABS UNIT:M M 3 214 5678 3 214 5678 B A C D E F G H B A C D E F G H REVDESCRIPTIONDESIGNDATEAPPROVED SHEET PROJECTION B SN ﹕ 2207480001 Not intended for infants weighing less than 10kg. Personal ECG Monitor Model: HHM3 Manufacture: Shenzhen Livenpace Technology Co., Ltd. Production Date: 2022.07 Made in China Internal Power: 3.7V/90mAh Li-ion rechargeable FCC ID: 2A728-0003 Input: DC 5 V , 1A
EUTPHOTO(InternalPhotos) ANT ※※※※※ENDOFREPORT※※※※※
FCCID:2A728-0003 RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1093 , UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. For100MHzto6GHzandtestseparationdistances≤50mm,the1-gand10-gSARtest exclusionthresholdsaredeterminedbythefollowing: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f (GHz) ]≤3.0for1-gSAR,and≤7.5for10-gextremitySAR,where f (GHz) istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultisroundedtoonedecimalplaceforcomparison Here, ForBluetooth Mode Max Power (dBm) Tune-up power (dBm) Max Power (mW) Frequency(MHz) Min. Distance (mm) Calc. thresholds limit BLE3.223 ± 12.51244050.7783.0 SoaSARtestisnotrequired
ProjectNo.:ZKT-220729L5315E Page 1 of 39 FCCTESTREPORT FCCID:2A728-0003 ReportNumber.....................................:ZKT-220729L5315E DateofTest ....................................................... : Jul.25,2022toAug.11,2022 Dateofissue ......................................... : Aug.11,2022 Totalnumberofpages..........................39 TestResult .......................................... : PASS TestingLaboratory. .............................. : ShenzhenZKTTechnologyCo.,Ltd. Address...............................................: 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname................................:ShenzhenLivenpaceTechnologyCo.,Ltd. Address ............................................... : 4F,BLD9,BaiwangxinIndustrialPark,SongbaiRoad,XiliStreet, NanshanDistrict,Shenzhen,China Manufacturer'sname.........................:ShenzhenLivenpaceTechnologyCo.,Ltd. Address...............................................: 4F,BLD9,BaiwangxinIndustrialPark,SongbaiRoad,XiliStreet, NanshanDistrict,Shenzhen,China Testspecification: Standard................................................:FCCCFRTitle47Part15SubpartCSection15.247 Testprocedure.....................................:KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10:2013 Testprocedure ..................................... :KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10:2013 Non-standardtestmethod................:N/A TestReportFormNo........................: TRF-EL-111_V0 TestReportForm(s)Originator.....: ZKTTesting MasterTRF ........................................ : Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname.......................................:PersonalECGMonitor Trademark...........................................: Model/Typereference.........................: HHM3 Ratings..................................................: Input:5V1AorDC3.7V,90mAh,0.333Whbybattery ProjectNo.:ZKT-220729L5315E Page 2 of 39 Testingprocedureandtestinglocation: TestingLaboratory.......................................:ShenzhenZKTTechnologyCo.,Ltd. Address............................................................:1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China JimLiu Testedby(name+signature).......................: TomZou Reviewer(name+signature).......................: LakeXie Approved(name+signature).......................: ProjectNo.:ZKT-220729L5315E Page 3 of 39 TableofContents Page 1.VERSION....................................................................................................................5 2.SUMMARYOFTESTRESULTS...............................................................................6 2.1TESTFACILITY.................................................................................................................7 2.2MEASUREMENTUNCERTAINTY....................................................................................7 3.GENERALINFORMATION........................................................................................8 3.1GENERALDESCRIPTIONOFEUT.................................................................................8 3.2DESCRIPTIONOFTESTMODES....................................................................................9 3.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED..............9 3.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)......................................10 3.5EQUIPMENTSLISTFORALLTESTITEMS.................................................................11 4.EMCEMISSIONTEST.............................................................................................12 4.1CONDUCTEDEMISSIONMEASUREMENT..................................................................12 4.1.1POWERLINECONDUCTEDEMISSIONLimits...................................................12 4.1.2TESTPROCEDURE...............................................................................................12 4.1.3DEVIATIONFROMTESTSTANDARD..................................................................12 4.1.4TESTSETUP...........................................................................................................13 4.1.5EUTOPERATINGCONDITIONS...........................................................................13 4.1.6TESTRESULTS......................................................................................................14 4.2RADIATEDEMISSIONMEASUREMENT......................................................................16 4.2.1RADIATEDEMISSIONLIMITS...............................................................................16 4.2.2TESTPROCEDURE...............................................................................................17 4.2.3DEVIATIONFROMTESTSTANDARD..................................................................17 4.2.4TESTSETUP...........................................................................................................17 4.2.5EUTOPERATINGCONDITIONS...........................................................................18 5.RADIATEDBANDEMISSIONMEASUREMENT.....................................................23 5.1TESTREQUIREMENT:..............................................................................................23 5.2TESTPROCEDURE..................................................................................................23 5.3DEVIATIONFROMTESTSTANDARD.....................................................................23 5.4TESTSETUP..............................................................................................................24 5.5EUTOPERATINGCONDITIONS.…
Text truncated - open the document above for the full version.
EUTTESTPHOTOS ※※※※※ENDOFREPORT※※※※※
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.09 mW |

Personal ECG Device
Equipment Class
DTS - Digital Transmission System
Personal ECG Tracker
Equipment Class
DTS - Digital Transmission System