Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions: (1)this device may not cause harmful interference,and (2)this device must accept any interference received, including interference that may cause undesired operation. Note:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates,uses,and can radiate radio frequency energy,and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However,there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. The device can use as portable without any restriction.
DongguanYuaochenTechnologyCo.,Ltd Room801,Building2,No.23,DalingshanSection,GuanchangRoad,Dalingshan Town,DongguanCity,GuangdongProvince FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 DateďźJuly17,2026 U.S.AgentDesignation {DongguanYuaochenTechnologyCo.,Ltd}acknowledgestheirconsentforthefollowingcontactlocatedinthe UnitedStatestoactastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCC ID:2A7A8-X20): NameandcompanyofU.S.agent:BridgeportAdvisoryLLC PhysicalU.S.addressofagent:3330W38THPL,CHICAGO,IL60632,UnitedStates FRNofU.S.agent:0037566148 EmailaddressofU.S.agent:[email protected] ContactNO.:(708)680-6688 BridgeportAdvisoryLLCacknowledgestheirobligationtoacceptserviceofprocessonbehalfof{Dongguan YuaochenTechnologyCo.,Ltd}. {DongguanYuaochenTechnologyCo.,Ltd}withtheFRN[0 3 2 5 127 90 ] acceptsitsobligationtomaintainan agentforserviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheveris later. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature CarrieChen Manager DongguanYuaochenTechnologyCo.,Ltd Signature MrYongLiu ManagingMember BridgeportAdvisoryLLC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5 0
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commissionâs Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2A7A8-X20 X20, X19 We, Applicant Company Name: Dongguan Yuaochen Technology Co., Ltd Address: Room 801, Building 2, No. 23, Dalingshan Section, Guanchang Road, Dalingshan Town, Dongguan City, Guangdong Province, China Phone: +86-755-26648642 certify that the equipment for which authorization is sought is not âcoveredâ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing âcoveredâ equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-07-17 Signature Date Name / Title: Carrie Chen / Manager Company: Dongguan Yuaochen Technology Co., Ltd Address: Room 801, Building 2, No. 23, Dalingshan Section, Guanchang Road, Dalingshan Town, Dongguan City, Guangdong Province, China Phone: +86-755-26648642 Fax: N/A E-Mail: [email protected]
Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2A7A8-X20 X20, X19 Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen Huaxia Testing Technology Co., Ltd Contact Name: Yoyo Zhou Address: 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Phone: +86-755-26648642 Email: [email protected] Signature: Date: 2026-07-22
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commissionâs Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2A7A8-X20 X20, X19 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: ⢠the Operational Description ⢠the Block Diagram ⢠the Schematics ⢠the Part List ⢠the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-07-17 Signature Date Name / Title: Carrie Chen / Manager Company: Dongguan Yuaochen Technology Co., Ltd Address: Room 801, Building 2, No. 23, Dalingshan Section, Guanchang Road, Dalingshan Town, Dongguan City, Guangdong Province, China Phone: +86-755-26648642 Fax: N/A E-Mail: [email protected]
Page 1 of 1 Rev.2.0 Dongguan Yuaochen Technology Co., Ltd WIFI Channel 12 and 13 Declaration Letter We declare the equipment identified below with regards to Channel 12 and 13 capabilities for FCC ID: 2A7A8-X20 Declaration Product hardware does not have the capability to operate on Channel 12 and 13. Product hardware has the capability to operate on Channel 12 and 13. However, these two channels will be disabled via software and will not be accessible to user. Product hardware has the capability to operate on Channel 12 and 13. However, all the operated channels canât be changed in the RF parameter via software. All channels have complied with all of the requirements sets out in FCC Part 15.247. Product hardware has the capability to operate on WiFi Channel 12 and 13, and meets the requirements of KDB 594280 D01 v02r01. Please note: 1.) By default, this device operates in a mode that is compliant with the U.S. requirements. 2.) This device will also use supplemental information such as geo- location data to determine that it is operating outside the U.S., if necessary, to change its power. Such supplemental data will be derived from the following: Global Navigation Satellite System (GNSS)7 sensors in the device Mobile Country Code (MCC),8 or MCC with a Mobile Network code (MNC), received from a CMRS9 carrier and received directly by a receiver on the device Country information derived from multiple adjacent access points (for example using IEEE Std 802.11d provisions) may be permitted on case-by-case basis Other suitable geo-location data based on IP addresses or other reliable source. Name / Title: Carrie Chen / Manager Signature: Phone: +86-755-26648642 Email: [email protected] Date: 2026-07-17
DongguanYuaochenTechnologyCo.,Ltd ModelConfirmationLetter We,DongguanYuaochenTechnologyCo.,Ltdcertifytheproduct: Actioncamera ModelNo.:X20,X19 FCCID:2A7A8-X20 Theirelectricalcircuitdesign,layout,componentsusedandinternalwiringareidentical, Onlytheappearanceweredifferent. Signiture: GranteeContact:CarrieChen CompanyName:DongguanYuaochenTechnologyCo.,Ltd Date:July17,2026
ReportNo.:CQASZ20260601264E Photographs-EUTConstructionalDetails FCC ID: 2A7A8-X20 ReportNo.:CQASZ20260601264E ReportNo.:CQASZ20260601264E ReportNo.:CQASZ20260601264E ReportNo.:CQASZ20260601264E
ReportNo.:CQASZ20260601264E Photographs-EUTConstructionalDetails FCC ID: 2A7A8-X20 ReportNo.:CQASZ20260601264E Antenna
SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,PeopleâsRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 TESTREPORT Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlytothe sample(s)tested.WithoutwrittenapprovalofCQA,thisreportcanâtbereproducedexceptinfull. ReportNo.: CQASZ20260601264E-02 Applicant:DongguanYuaochenTechnologyCo.,Ltd AddressofApplicant:Room801,Building2,No.23,DalingshanSection,GuanchangRoad, DalingshanTown,DongguanCity,GuangdongProvince EquipmentUnderTest(EUT): EUTName:Actioncamera ModelNo.:X20,X19 TestModelNo.:X20 BrandName:N/A FCCID: 2A7A8-X20 Standards: 47CFRPart1.1307 47CFRPart1.1310 KDB447498D01GeneralRFExposureGuidancev06 DateofReceipt:2026-06-18 DateofTest: 2026-06-18to2026-07-16 DateofIssue: 2026-07-22 TestResult:PASS TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260601264E-02 Page: 2 of 6 1.Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260601264E-02Rev.01 Initialreport 2026-07-22 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260601264E-02 Page: 3 of 6 2.Contents 1.VERSION....................................................................................................................................................................................2 2.CONTENTS................................................................................................................................................................................3 3.GENERALINFORMATION....................................................................................................................................................4 4.CLIENTINFORMATION........................................................................................................................................................4 5.GENERALDESCRIPTIONOFEUT......................................................................................................................................4 6.GENERALDESCRIPTIONOF2.4GWIFICLASSIC.........................................................................................................4 RFEXPOSUREEVALUATION..................................................................................................................................................5 RFEXPOSURECOMPLIANCEREQUIREMENT.............................................................................................................................5 StandardRequirement........................................................................................................................................................5 Limits......................................................................................................................................................................................5 EUTRFExposure................................................................................................................................................................6 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260601264E-02 Page: 4 of 6 3.GeneralInformation 4.ClientInformation Applicant: DongguanYuaochenTechnologyCo.,Ltd AddressofApplicant: Room801,Building2,No.23,DalingshanSection,GuanchangRoad, DalingshanTown,DongguanCity,GuangdongProvince Manufacturer: DongguanYuaochenTechnologyCo.,Ltd AddressofManufacturer: Room801,Building2,No.23,DalingshanSection,GuanchangRoad, DalingshanTown,DongguanCity,GuangdongProvince Factory: DongguanYuaochenTechnologyCo.,Ltd AddressofFactory: Room801,Building2,No.23,DalingshanSection,GuanchangRoad, DalingshanTown,DongguanCity,GuangdongProvince 5.GeneralDescriptionofEUT ProductName: Actioncamera ModelNo.: X20,X19 TestModelNo.: X20 TradeMark: N/A SoftwareVersion: V1.0 HardwareVersion: V1.0 PowerSupply: Li-ionbatteryDC3.7V1000mAh,ChargebyDC5Vforadapter SimultaneousTransmissionSimultaneousTXissupportedandevaluatedinthisreport. SimultaneousTXisnotsupported. 6.GeneralDescriptionof2.4GWIFIClassic OperationFrequency: 2412MHz~2462MHz TypeofModulation: IEEEfor802.11b:DSSS(CCK,DQPSK,DBPSK) NumberofChannel: IEEE802.11b:11Channels ChannelSeparation: 5MHz TransferRate: IEEEfor802.11b:1Mbps/2Mbps/5.5Mbps/11Mbps SampleType: MobilePortable AntennaType:PCBantenna AntennaGain:0.41dBi SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260601264E-02 Page: 5 of 6 RFExposureEvaluation RFExposureComplianceRequirement StandardRequirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06 4.3.1.StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1- gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARExclusionThresholdcondition,listedbelow,issatisfied. Limits The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparation distancesâ¤50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]¡[âf(GHz)]â¤3.0for1-gSARandâ¤7.5for10-gextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation17 Theresultisroundedtoonedecimalplaceforcomparison Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceisâ¤50mm andfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmisappliedtodetermineSARtestexclusion SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260601264E-02 Page: 6 of 6 EUTRFExposure 1)For2.4GWIFI MeasurementData Worstcase: 802.11b TestChannel AV OutputPower (dBm) Tuneuptolerance (dBm) Maximumtune-upPower (dBm)(mW) Lowest(2412MHz) 2.19 2.5Âą1 3.5 2.24 Middle(2437MHz) 2âŚ
Text truncated - open the document above for the full version.
2.4G Hz Antenna Specifications 1 Model: 2.4GHz PCB ANT Dongguan Yuaochen Technology Co., Ltd Address: Room 801, Building 2, No. 23, Dalingshan Section, Guanchang Road, Dalingshan Town, Dongguan City, Guangdong Province, China Test system 2 Antenna size 3 Efficiency & Gain 4 5 6
CQASZ20260601264E-01 AppendixA:DTSBandwidth TestResult TestModeFrequency[MHz] DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11B 241212.162405.922418.080.5PASS 243712.282430.842443.120.5PASS 246212.722455.482468.200.5PASS TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 AppendixB:OccupiedChannelBandwidth TestResult TestMode Channel Frequency[MHz] OCB [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11B 241215.3052404.36762419.6723------ 243715.1452429.40762444.5524------ 246215.1852454.36762469.5524------ TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 AppendixC:Maximumconductedoutputpower TestResultAverage Test Mode Frequency[M Hz] Result[dBm]Limit[dBm]Verdict 11B 24122.19â¤30.00PASS 24372.20â¤30.00PASS 24621.70â¤30.00PASS TestGraphsAverage 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 AppendixD:Maximumpowerspectraldensity TestResult TestModeFrequency[MHz]Result[dBm/3-100kHz]Limit[dBm/3kHz]Verdict 11B 2412-20.93â¤8.00PASS 2437-20.77â¤8.00PASS 2462-20.94â¤8.00PASS TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 AppendixE:Bandedgemeasurements TestResult TestModeChNameFrequency[MHz]RefLevel[dBm]Result[dBm]Limit[dBm]Verdict 11B Low2412-8.79-43.76â¤-38.79PASS High2462-9.38-42.74â¤-39.38PASS TestGraphs 11B_Ant1_Low_2412 11B_Ant1_High_2462 AppendixF:ConductedSpuriousEmission TestResult TestModeFrequency[MHz] FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11B 2412 Reference-10.55-10.55---PASS 30~1000-10.55-51.59â¤-40.55PASS 1000~26500-10.55-48.43â¤-40.55PASS 2437 Reference-9.96-9.96---PASS 30~1000-9.96-50.56â¤-39.96PASS 1000~26500-9.96-47.7â¤-39.96PASS 2462 Reference-9.90-9.90---PASS 30~1000-9.90-51.66â¤-39.9PASS 1000~26500-9.90-48.16â¤-39.9PASS TestGraphs 11B_Ant1_2412_0~Reference 11B_Ant1_2412_30~1000 11B_Ant1_2412_1000~26500 11B_Ant1_2437_0~Reference 11B_Ant1_2437_30~1000 11B_Ant1_2437_1000~26500 11B_Ant1_2462_0~Reference 11B_Ant1_2462_30~1000 11B_Ant1_2462_1000~26500 AppendixG:DutyCycle TestResult TestModeFrequency[MHz] Transmission Duration[ms] Transmission Period[ms] DutyCycle [%] 11B 24120.991.0198.02 24370.991.0099.00 24620.981.0098.00 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462
SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,PeopleâsRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 TESTREPORT Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcanâtbereproducedexceptinfull. ReportNo.:CQASZ20260601264E-01 Applicant:DongguanYuaochenTechnologyCo.,Ltd AddressofApplicant:Room801,Building2,No.23,DalingshanSection,GuanchangRoad,Dalingshan Town,DongguanCity,GuangdongProvince EquipmentUnderTest(EUT): Product:Actioncamera ModelNo.:X20,X19 TestModelNo.:X20 BrandName:N/A FCCID:2A7A8-X20 Standards:47CFRPart15,SubpartC KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10:2020 DateofReceipt:2026-06-18 DateofTest: 2026-06-18to2026-07-16 DateofIssue:2026-07-22 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove . TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260601264E-01 Page:2of34 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260601264E-01Rev.01 Initialreport 2026-07-22 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260601264E-01 Page:3of34 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement47CFRPart15.203N/APASS ACPowerLine Conducted Emission 47CFRPart15.207 ANSI C63.10-2020+Cor.1- 2023+C63.10a-2024+Erratato C63.10a-2024 PASS ConductedPeak& AverageOutputPower 47CFRPart15.247 ANSI C63.10-2020+Cor.1- 2023+C63.10a-2024+Erratato C63.10a-2024 PASS 6dBOccupied Bandwidth 47CFRPart15.247 ANSI C63.10-2020+Cor.1- 2023+C63.10a-2024+Erratato C63.10a-2024 PASS PowerSpectralDensity47CFRPart15.247 ANSI C63.10-2020+Cor.1- 2023+C63.10a-2024+Erratato C63.10a-2024 PASS Band-edgeforRF ConductedEmissions 47CFRPart15.247 ANSI C63.10-2020+Cor.1- 2023+C63.10a-2024+Erratato C63.10a-2024 PASS RFConductedSpurious Emissions 47CFRPart15.247 ANSI C63.10-2020+Cor.1- 2023+C63.10a-2024+Erratato C63.10a-2024 PASS RadiatedSpurious Emissions 47CFRPart15.209 ANSI C63.10-2020+Cor.1- 2023+C63.10a-2024+Erratato C63.10a-2024 PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart 15.205/15.209 ANSI C63.10-2020+Cor.1- 2023+C63.10a-2024+Erratato C63.10a-2024 PASS Remark: Thetestedsample(s)andthesampleinformationareprovidedbytheclient. Tx:InthiswholereportTx(ortx)meansTransmitter. Rx:InthiswholereportRx(orrx)meansReceiver. RF:InthiswholereportRFmeansRadiatedFrequency. CH:InthiswholereportCHmeanschannel. Volt:InthiswholereportVoltmeansVoltage. Temp:InthiswholereportTempmeansTemperature. Humid:InthiswholereportHumidmeanshumidity. Press:InthiswholereportPressmeansPressure. N/A:Inthiswholereportnotapplication SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260601264E-01 Page:4of34 3Contents Page 1VERSION......................................................................................................................................................................2 2TESTSUMMARY........................................................................................................................................................3 3CONTENTS..................................................................................................................................................................4 4GENERALINFORMATION.......................................................................................................................................5 4.1CLIENTINFORMATION.............................................................................................................................................5 4.2GENERALDESCRIPTIONOFEUT..........................................................................................................................5 4.3PRODUCTSPECIFICATIONSUBJECTIVETOTHISSTANDARD................................................................................5 4.4TESTENVIRONMENTANDMODE...........................................................................................................................7 4.5DESCRIPTIONOFSUPPORTUNITS........................................................................................................................8 4.6TESTLOCATION......................................................................................................................................................8 4.7TESTFACILITY........................................................................................................................................................8 4.8TESTCONFIGURATION............................................................................................................................................8 4.9STATEMENTOFTHEMEASUREMENTUNCERTAINTY.............................................................................................9 4.10DEVIATIONFROMSTANDARDS............................................................................................................................9 4.11ABNORMALITIESFROMSTANDARDCONDITIONS................................................................................................9 4.12OTHERINFORMATIONREQUESTEDBYTHECUSTOMER....................................................................................9 4.13EQUIPMENTLIST................................................................................................................................................10 5TESTRESULTSANDMEASUREMENTDATA..................................................................................................11 5.1ANTENNAREQUIREMENT.....................................................................................................................................11 5.2CONDUCTEDEMISSIONS...........................âŚ
Text truncated - open the document above for the full version.
ReportNo.:CQASZ20260601264E 1Photographs-EUTTestSetup 1.1RadiatedSpuriousEmission 9kHz~30MHz: 30MHz~1GHz: FCC ID: 2A7A8-X20 ReportNo.:CQASZ20260601264E Above1GHz: 1.2 ConductedEmission ReportNo.:CQASZ20260601264E 1.3 RFConductedmeasurement
3330 W 38TH PL, CHICAGO, ¡ Illinois, 60632 ¡ United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 1.70 mW |
Smart Visual Doorbell
Equipment Class
DTS - Digital Transmission System
Smart camera
Equipment Class
DTS - Digital Transmission System