FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. G-YOUTH TECHNOLOGIES (SHENZHEN) CO., LTD/
  3. 2A7H7-SONIC-1200

2A7H7-SONIC-1200Portable Power Station Sonic

G-YOUTH TECHNOLOGIES (SHENZHEN) CO., LTD
Portable Power Station Sonic - FCC ID 2A7H7-SONIC-1200 - G-YOUTH TECHNOLOGIES (SHENZHEN) CO., LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Mar 04, 2023
Application Purpose
Original Equipment
Date of Application
Mar 04, 2023
Equipment Note
Portable Power Station Sonic
Frequency Range
0.11500000 - 0.20500000
Company
G-YOUTH TECHNOLOGIES (SHENZHEN) CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

FCCID:2A7H7-SONIC-1200 External

ID Label/Location Info

Model:Sonic1200WCapacity:37V,27Ah,999Wh ACInput:100-120V~,60Hz,rated1000W PVInput:10-24V11AMax,200WMax USB-AOutput(*2):5V3A/9V2.6A/12V2A(24WMax) USB-COutput(*2):5V3A/9V3A/12V3A/15V3A/20V5A(100WMax) ACOutput(*2):120V,50Hz,rated1200W(PureSineWave) Carport(*1):12V10AMaxLEDlights:3.2W Wirelesscharging(*1):15WMax ChargingTemperature:32~104°F(0~40°C) DischargingTemperature:14~104°F(-10~40°C) mm*mm Madeinchina WARNING Donotoverchargetheinternalbattery.SeeInstructionManual. Donotsmoke,strikeamatch,orcauseasparkinthevicinityofthe powerpack. Onlychargetheinternalbatteryinawellventilatedarea. CAUTION RiskofElectricShock.Connectonlytoproperlygroundedoutlets. RiskofInjuryToPersons.Donotusethisproductifthepowercordorthe batterycablesaredamagedinanyway. Thisdeviceisnotintendedforuseinacommercialrepairfacility. AVERTISSEMENT Nepassurchargerlabatterieinterne.Consulterlemanueld'utilisation. Ilnefautpasfumer,allumeruneallumetteouproduiredesétincellesà proximitédublocd'alimentation. Chargerlabatterieuniquementdansunendroitbienaéré. MISEENGARDE Risquededéchargeélectrique.Brancherl'unitéuniquementàdesprises decourantcorrectementmisesàlamasse. Risquedeblessureauxpersonnes.Nepasutiliserceproduitsilecordon d'alimentationoulescâblesdebatteriesontendommagésdequelque façon. Ledispositifn'estpasdestinéàêtreutilisédansunatelierderéparation commercial. PortablePowerStationSonic FCCID:2A7H7-SONIC-1200 Label location Label size (mm)

Internal Photos

FCCID:2A7H7-SONIC-1200 Internal

RF Exposure Info

TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 1 of 7 RFExposureEvaluation FCCID:2A7H7-SONIC-1200 MeasuringStandard FCCPart1(1.1310)andPart2(2.1091) KDB680106D01RFExposureWirelessChargingBaseAppv03 TestConfiguration ThetestdistanceofPositionEonthefrontsideis20cm,thetestdistanceofPositionA,B,C,Dis15cmusing theequipmentlistabovefordeterminingcompliancewiththeMPErequirementsofFCCPart1.1310. TheRFpowerdensitywasmeasuredatUndermaximumloadtest. ThetestdistanceofPositionEonthefrontsideis20cm,thetestdistanceofPositionA,B,C,Dis15cm,the fieldprobeswerepositionedatthelocationwherethereismaximumfieldstrength.ThemaximumE-fieldand H-fieldisreportedbelow. Thisdeviceusesawirelesschargingcircuitforpowertransferoperatingatthefrequencyof115KHz-205kHz. Thus,the300kHzlimitswereused:E-fieldLimit=614(V/m);H-fieldlimit=1.63(A/m). TESTSetup TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 2 of 7 TESTLimits MeasuringDeviceandTestEquipment DescriptionManufacturerModelS/N Cal.Until ProbeFHP (1Hz-400KHz) NardaSafetyTest SolutionsGmbH EHP-50F J-0015 Nov.01,2023 PHONE1HUAWEIP40N/AN/A TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 3 of 7 TESTMODE MODETESTMODEDESCRIPTION 1Wirelesschargingmode(Fullload) 2Wirelesschargingmode(Halfload) 3Wirelesschargingmode(Nullload) Note:TheMode1wastheworstcaseandonlythedataoftheworstcaserecordinthisreport. TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 4 of 7 TESTRESULT PassedNotApplicable EUTPortablePowerStationModelName.:Sonic1200W Pressure:1012hPaTestDate:2023-02-16 TestVoltage:Output:15W(Max)TestMode:Mode1(worsecase) E-FieldStrengthat15cmsurroundingtheEUTand20cmabovethetopsurfaceoftheEUT EUTSide Frequency Range (KHz) Probe A (V/m) Probe B (V/m) Probe C (V/m) Probe D (V/m) Probe E (V/m) Limits (V/m) 50%Limit (V/m) Fullload115~2050.880.870.900.912.99 614307 Halfload115~2050.820.810.840.852.93 Nullload115~2050.750.740.770.782.86 H-FieldStrengthat15cmsurroundingtheEUTand20cmabovethetopsurfaceoftheEUT EUTSide Frequency Range (KHz) Probe A (A/m) Probe B (A/m) Probe C (A/m) Probe D (A/m) Probe E (A/m) Limits (A/m) 50%Limit (A/m) Fullload115~2050.430.420.460.450.75 1.630.815Halfload115~2050.400.390.430.420.72 Nullload115~2050.390.380.420.410.71 Remark:ThedevicemeetsthemobileRFexposurelimitata15cmseparationdistanceasspecified in§2.1091oftheFCCRules. Note:OnlytheMode1worstcasemodesisrecordedinthereport. TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 5 of 7 PHOTOGRAPHSOFTESTSETUP PositionE PositionA TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 6 of 7 PositionB PositionC TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 7 of 7 PositionD **********************THEEND**********************

Test Report

ReportNo.:KS2212S5873E TRFNo.FCCPart15C_R2 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]: www.gdksign.com Page 1 of 31 1 TESTREPORT ReportNo...........................................:KS2212S5873E FCCID..................................................: 2A7H7-SONIC-1200 Applicant..............................................: G-YouthTECHNOLOGIES(Shenzhen)CO.LTD Address. ................................................ :6thFloor,BlockA,HainaBaichuanHeadquartersBuilding,No.6 BaoxingRoad,Xing'anStreet,Bao'anDistrict,Shenzhen Manufacturer........................................: G-YouthTECHNOLOGIES(Shenzhen)CO.LTD Address.................................................: 6thFloor,BlockA,HainaBaichuanHeadquartersBuilding,No.6 BaoxingRoad,Xing'anStreet,Bao'anDistrict,Shenzhen ProductName. .................................... :PortablePowerStationSonic TradeMark. ........................................... : Model/Typereference. ........................ :Sonic1200W Standard. ............................................. : FCCRulesandRegulationsPart15SubpartC(Section15.209), ANSIC63.10:2013 Dateofreceiptoftestsample. ........... : December21,2022 Dateoftesting......................................:December21,2022toFebruary17,2023 Dateofissue.........................................:February17,2023 TestResult. ......................................... :Pass Preparedby: (PrintedName+Signature) PaiZheng Approvedby: (PrintedName+Signature) SkyDong TestingLaboratoryName ................ :KSIGN(Guangdong)TestingCo.,Ltd. Address ................................................. : WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,Jiujiu IndustrialPark,Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen, Guangdong,China Thistestreportmaybeduplicatedcompletelyforlegalusewiththeapprovaloftheapplicant.Itshouldnot bereproducedexceptinfull,withoutthewrittenapprovalofourlaboratory.Theclientshouldnotuseitto claimproductendorsementbyKSIGN.Thetestresultsinthereportonlyapplytothetestedsample.The testreportshallbeinvalidwithoutallthesignaturesoftestingengineers,reviewerandapprover. AnyobjectionsmustberaisedtoKSIGNwithin15dayssincethedatewhenthereportisreceived.Itwillnot betakenintoconsiderationbeyondthislimit.Thetestreportmerelycorrespondtothetestsample. ReportNo.:KS2212S5873E TRFNo.FCCPart15C_R2 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]: www.gdksign.com Page 2 of 31 2 Contents 1TESTSUMMARY..............................................................................................................................................3 1.1TestStandards................................................................................................................................................3 1.2ReportVersion................................................................................................................................................3 1.3Summaryofmeasurementresults..................................................................................................................4 1.4Statementofthemeasurementuncertainty...................................................................................................4 1.5Modifications...................................................................................................................................................4 1.6Addressofthetestlaboratory.........................................................................................................................5 1.7Environmentalconditions................................................................................................................................5 2GENERALINFORMATION...............................................................................................................................6 2.1ProductDescription........................................................................................................................................6 2.2Descriptionofthetestmode...........................................................................................................................7 2.3SpecialAccessories........................................................................................................................................7 2.4EquipmentsUsedduringtheTest..................................................................................................................8 3.TESTCONDITIONSANDRESULTS...............................................................................................................9 3.1ACPowerConductedEmission.....................................................................................................................9 3.2RadiatedEmission........................................................................................................................................12 3.3AntennaRequirement...................................................................................................................................20 4.TESTSETUPPHOTOSOFTHEEUT...........................................................................................................21 5.PHOTOSOFTHEEUT..................................................................................................................................23 ReportNo.:KS2212S5873E TRFNo.FCCPart15C_R2 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]: www.gdksign.com Page 3 of 31 3 1TESTSUMMARY 1.1TestStandards Thetestswereperformedaccordingtofollowingstandards: FCCRulesandRegulationsPart15SubpartC(Sectio…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2A7H7-SONIC-1200 RadiatedMeasurement(Below30MHz) RadiatedMeasurement(Above30MHz) ConductedEmission

Contact Information

Applicant

Yuying Liang
[email protected]15574950869Fax: 15574950869

Technical Contact

G-Youth TECHNOLOGIES (Shenzhen) CO.LTD
[email protected]

China

Test Firm

KSIGN (Guangdong) Testing Co., Ltd.Neil Wan
[email protected]+(86) 0755-2985 2678

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.115 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from G-YOUTH TECHNOLOGIES (SHENZHEN) CO., LTD

iFory LeapBuds E, TWS Earphones - FCC ID 2A7H7-GY1025 - G-YOUTH TECHNOLOGIES (SHENZHEN) CO., LTD
2A7H7-GY1025

iFory LeapBuds E, TWS Earphones

Nov 08, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter